PM9607AP Search Results
PM9607AP Datasheets (1)
Sames
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| PM9607AP | Sames | Energy Meter Evaluation Module | Original | 373.08KB | 16 |
Documents mentioning PM9607AP
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| pm9607ap | Application Note: Energy Meter Evaluation Module sames PM9607AP INTRODUCTION meter configurations possible with the SA9607M using the PM9607AP module. Note that the values of the current transformer’s resistor values need to change to make some of the rated conditions possible. This will be covered in the |
Original | ||||
| sa2005m | Pin Selectable Three Phase Power / Energy Metering IC for Stepper Motor / Impulse Counter Applications with Anti Tamper Features SA2005M FEATURES + Direct drive for + + + + electro-mechanical counters or stepper motors Selectable dividing ratios for different meter rated |
Original | ||||
| sa2005 | Evaluation Board for the SA2005F Energy Metering IC sames PM2005FPD FEATURES + Designed to be used as a fully functional Watt-Hour meter. + Better than Class 1 operation + On-board power supply + 3 Phase 4 Wire configuration + + On-board current transformers |
Original | ||||
| Single Phase Kilowatt-hour Metering IC for | Single Phase Kilowatt-hour Metering IC for Mechanical Display Applications Sames SA2002D FEATURES + Provides a single chip solution for energy meters having a + + + + + mechanical display + + + + No external crystal or resonator required Direct stepper motor / impulse counter drive |
Original | ||||
| sa2007p | Programmable Single Phase Energy Metering IC with Tamper Detection sames SA2007P FEATURES + Provides direct interface to mechanical counters + Calibration and setup stored on external EEPROM - no + + + + + + + + trimpots required Monitors both Live and Neutral for tamper detection |
Original | ||||
| sa2102d | Single Phase Kilowatt-hour Metering IC sames SA2102D FEATURES + Meets the IEC 61036 Specification requirements for Class + + + + + + 1 AC static watt-hour meters for active energy + + Less than 0.5% Error over a dynamic range of 1:1000 The motor drive outputs (MOP, MON) provide the average |
Original | ||||
| sa2007m | Evaluation Board for the SA2007M Energy Metering IC sames PM2007MSE FEATURES + Designed to be used as fully functional Watt-Hour meter. + + + + + + + Continuously measures both Live and Neutral for tamper detection. Accurately measures the energy consumption even |
Original | ||||
| Single Phase Power/Energy Metering IC with Tamper | Single Phase Power/Energy Metering IC with Tamper Detection sames SA9607M FEATURES + + + + + + Provides direct interface to mechanical counters Monitors Live and Neutral for tamper detection Performs bidirectional energy measurement Various setup modes selectable |
Original | ||||
| sa2007m | Single Phase Power/Energy Metering IC with Tamper Detection sames SA2007M FEATURES + Provides direct interface to mechanical counters + Monitors Live and Neutral for tamper detection + Performs bidirectional energy measurement + Various setup modes selectable |
Original | ||||
| sa2005f | Three Phase Bidirectional Power/Energy Metering IC with Instantaneous Pulse Output sames SA2005F FEATURES n n n n n n n n n Functionally compatible with the SA9105F with reduced external components Performs bidirectional one, two or three phase power and energy measurement |
Original | ||||
| sa9904 | Three Phase Power / Energy IC with SPI Interface sames SA9904A FEATURES + Bi-directional + + + + + active and reactive power/energy measurement RMS Voltage and frequency measurement Individual Phase information SPI communication bus Meets the IEC 521/1036 Specification requirements for |
Original | ||||
| sa2005p | Programmable Three Phase Power / Energy Metering IC for Stepper Motor / Impulse Counter Applications sames SA2005P FEATURES + Direct drive for + + + + electro-mechanical counters or stepper + motors Calibration and setup stored on external EEPROM - no trim-pots required |
Original | ||||
| sa2005p | Programmable Three Phase Power / Energy Metering IC for Stepper Motor / Impulse Counter Applications sames SA2005P FEATURES + Direct drive for + + + + electro-mechanical counters or stepper + motors Calibration and setup stored on external EEPROM - no trim-pots required |
Original | ||||
| sa2002e | Single Phase Uni-directional Power / Energy Metering IC with Instantaneous Pulse Output sames SA2002E + FEATURES + Functionally compatible with the SA9602E with reduced + + + + + external components + + Uni-directional power and energy measurement Meets the IEC 521/1036 Specification requirements for |
Original | ||||
|
|
||||||
| Single Phase Kilowatt-hour Metering IC sames | Single Phase Kilowatt-hour Metering IC sames SA2102D FEATURES + Meets the IEC 61036 Specification requirements for + + + + + + Class 1 AC static watt-hour meters for active energy + + Less than 0.5% Error over a dynamic range of 1:1000 The motor drive outputs (MOP, MON) provide the average |
Original | ||||
Single Phase Kilowatt-hour Metering IC for Mechanical Display Applications Sames SA2002D FEATURES + Provides a single chip solution for energy meters having a + + + + + mechanical display + + + + No external crystal or resonator required Direct stepper motor / impulse counter drive |
Original | |||||
| sa9904b | Evaluation Board for the SA9904B Energy Metering IC sames PM9904BPD FEATURES + Designed to + + + + be used together with accompanying software as fully functional three phase trivector meter. Better than class 1 operation. On board power supply. Two on-board LED’s for active and reactive pulse output. |
Original | ||||
| pm2002dp | Application Note: Energy Meter Evaluation Module sames PM2002DP INTRODUCTION CONNECTORS ON MODULE This application note describes the functionality of the SA2002D metering integrated circuit using the PM2002DP evaluation module. The PM2002DP module connects directly to live and neutral |
Original | ||||