C2007G
Abstract: DILM32
Contextual Info: Type: DILM32−XTEY20 RAC130 Article No.: 101447 Sales text Timer module,1−30s,star−delta Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net
|
Original
|
dilm32-xtey20rac1301-30sd-53115+3hpl-c2007gc2007gdilm32
|
PDF
|
DILM32-XTEE11
Abstract: moeller C2007G DILM32 101440
Contextual Info: Type: DILM32−XTEE11 RA24 Article No.: 101440 Sales text Timer module,0.1−100s,on−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net
|
Original
|
dilm32-xtee111-100sd-53115hpl-c2007g+5lm32-xtee11moellerc2007gdilm32101440
|
PDF
|
star-delta
Abstract: RAC240 C2007G DILM32 Moeller HPL-C2007G
Contextual Info: Type: DILM32−XTEY20 RAC240 Article No.: 101448 Sales text Timer module,1−30s,star−delta Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net
|
Original
|
dilm32-xtey20rac2401-30sd-53115+5hpl-c2007gstar-deltac2007gdilm32moeller
|
PDF
|
DILM7 moeller
Abstract: Moeller combined DILMP20 DILM32-XTED11-10 str z2062 timer data sheet C2007G DILM32
Contextual Info: Type: DILM32−XTED11−10 RA24 Article No.: 104943 Sales text Timer module,0.5−10s,off−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 24 V AC/DC For use with DILM7 – DILM32
|
Original
|
dilm32-xted11-105-10sdilm32dilmp20+8d-53115hpl-c2007gdilm7 moellermoellercombinedstr z2062timer data sheetc2007g
|
PDF
|
suppressor
Abstract: DILM150 contactor VOLTAGE SUPPRESSOR C2007G DILM115 DILM32 DILMP125
Contextual Info: Type: DILM32−XSPR48 Article No.: 281202 Sales text RC−suppressor f. DILM17.32 Ordering information Voltage For use with Us V 24 – 48 AC DILM17 – DILM32 DILMP32 DILMP45 Contact sequence Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
|
Original
|
dilm32-xspr48dilm17dilm32dilmp32+9dilmp45dilm115dilm150dilmp125d-53115suppressorcontactorvoltage suppressorc2007g
|
PDF
|
DILM32-XTEE11
Abstract: VDE 0660 star delta wiring DILM32-XTEY20 moeller VDE 0660 star delta timer moeller IEC 60947 VDE 0660 NFEN60947-2 star delta timer C2007G DILM32
Contextual Info: Type: DILM32−XTEY20 RAC240 Article No.: 101448 Sales text Timer module,1−30s,star−delta Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 200.240 V AC For use with DILM7 – DILM32
|
Original
|
dilm32-xtey20rac2401-30sdilm32+12dilmp20dilm32-xtee11/dilm32-xted11dc-13d-53115dilm32-xtee11vde 0660star delta wiringmoeller vde 0660star delta timer moelleriec 60947 vde 0660 nfen60947-2star delta timerc2007g
|
PDF
|
DILM32
Contextual Info: Type: DILM32−10 230V50HZ,240V60HZ Article No.: 277260 Ordering information Rated operational current AC−3 400 V Ie A 32 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 10 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
|
Original
|
dilm32-10230v50hz240v60hzdilm32-xhi+3d-53115hpl-c2005gb-intdilm32
|
PDF
|
ZB32-4
Abstract: DILM32 ZB32-XEZ
Contextual Info: Type: ZB32−4 Article No.: 278449 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
|
Original
|
zb32-4dilm17dilm25dilm32+7diulm17diulm25diulm32sdainlm30sdainlm45sdainlm55zb32-xez
|
PDF
|
ZB32-10
Abstract: ZB32-XEZ sdainlm30 DIULM25 DILM32 SDAINLM45 Class 10 thermal overload VDE 0106 moeller zb32
Contextual Info: Type: ZB32−10 Article No.: 278451 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
|
Original
|
zb32-10dilm17dilm25dilm32+10diulm17diulm25diulm32sdainlm30sdainlm45sdainlm55zb32-xezclass 10 thermal overloadvde 0106moeller zb32
|
PDF
|
ZB32-32
Abstract: ZB32-XEZ DILM32 moeller IEC EN 60947 VDE 0660
Contextual Info: Type: ZB32−32 Article No.: 278454 Ordering information Overload release, min. – max. Ir A 24 – 32 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
|
Original
|
zb32-32dilm17dilm25dilm32+8diulm17diulm25diulm32sdainlm30sdainlm45sdainlm55zb32-xezmoeller iec en 60947 vde 0660
|
PDF
|
DILM32-XTEE11
Abstract: C2007G DILM32 D-53115
Contextual Info: Type: DILM32−XTEE11 RAC130 Article No.: 101441 Sales text Timer module,0.1−100s,on−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net
|
Original
|
dilm32-xtee11rac1301-100sd-53115+4hpl-c2007glm32-xtee11c2007gdilm32
|
PDF
|
moeller
Abstract: D-53115 catalog DILM7 moeller 100S combined str z2062 timer data sheet C2007G DILM32
Contextual Info: Type: DILM32−XTED11−100 RA24 Article No.: 104946 Sales text Timer module,5−100s,off−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 24 V AC/DC For use with DILM7 – DILM32
|
Original
|
dilm32-xted11-1005-100sdilm32dilmp20+10d-53115hpl-c2007gmoellercatalogdilm7 moeller100scombinedstr z2062timer data sheetc2007g
|
PDF
|
Moeller
Abstract: str z2062 timer data sheet C2007G DILM32 DILMP20 DILM32-XTED11-10
Contextual Info: Type: DILM32−XTED11−10 RAC130 Article No.: 104944 Sales text Timer module,0.5−10s,off−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 100 . 130 V AC For use with DILM7 – DILM32
|
Original
|
dilm32-xted11-10rac1305-10sdilm32+7dilmp20d-53115hpl-c2007gmoellerstr z2062timer data sheetc2007g
|
PDF
|
star delta timer moeller
Abstract: DILM32-XTEE11 star delta wiring VDE 0660 DILM7 moeller moeller VDE 0660 DILM32 DILM32-XTEY20 IEC 60947 VDE 0660 NFEN60947-2 C2007G
Contextual Info: Type: DILM32−XTEY20 RA24 Article No.: 101446 Sales text Timer module,1−30s,star−delta Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 24 V AC/DC For use with DILM7 – DILM32 DILMP20
|
Original
|
dilm32-xtey201-30sdilm32dilmp20+12dilm32-xtee11/dilm32-xted11dc-13d-53115hpl-c2007gstar delta timer moellerdilm32-xtee11star delta wiringvde 0660dilm7 moellermoeller vde 0660iec 60947 vde 0660 nfen60947-2c2007g
|
PDF
|
|
|
DILM7 moeller
Abstract: str z2062 Moeller C2007G DILM32 DILMP20
Contextual Info: Type: DILM32−XTED11−1 RAC130 Article No.: 105211 Sales text Timer module, 0.05−1s, off−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 100 . 130 V AC For use with DILM7 – DILM32
|
Original
|
dilm32-xted11-1rac13005-1sdilm32+7dilmp20d-53115hpl-c2007gdilm7 moellerstr z2062moellerc2007g
|
PDF
|
DILM32-XTED11-1
Abstract: C2007G DILM32 DILMP20
Contextual Info: Type: DILM32−XTED11−1 RA24 Article No.: 105210 Sales text Timer module, 0.05−1s, off−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 24 V AC/DC For use with DILM7 – DILM32
|
Original
|
dilm32-xted11-105-1sdilm32dilmp20+3d-53115hpl-c2007gc2007g
|
PDF
|
DILM32
Abstract: ZB32-XEZ
Contextual Info: Type: ZB32−1,6 Article No.: 278447 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
|
Original
|
zb32-1dilm17dilm25dilm32+7diulm17diulm25diulm32sdainlm30sdainlm45sdainlm55zb32-xez
|
PDF
|
ZB32-1
Abstract: DILM32 ZB32-XEZ
Contextual Info: Type: ZB32−1 Article No.: 278446 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
|
Original
|
zb32-1dilm17dilm25dilm32+7diulm17diulm25diulm32sdainlm30sdainlm45sdainlm55zb32-xez
|
PDF
|
DILM32-XTEE11
Abstract: M32-XTEY biestable DILM32-XTED11-10 relais electrique DILM32-XTE DILM32-XTEY20 DILM15 moeller DILM15 AWA2527-2320
Contextual Info: A 05/06 AWA2527-2320 Montageanweisung Installation Instructions Notice d’installation Istruzioni per il montaggio Instrucciones de montaje Инструкция по монтажу DILM32-XTE. Lebensgefahr durch elektrischen Strom! Nur Elektrofachkräfte und elektrotechnisch
|
Original
|
awa2527-2320dilm32-xtedilm32-xted11dilm32-xtee11+11dilm32-xtey20dilm32-xteplh-xtey20dilm32-xted11-1dilm32-xted11-10dilm32-xted11-100m32-xteybiestablerelais electriquedilm15 moellerdilm15
|
PDF
|
Moeller
Abstract: str z2062 DILM32 100S timer data sheet C2007G DILMP20 DILM32-XTED11-100
Contextual Info: Type: DILM32−XTED11−100 RAC130 Article No.: 104947 Sales text Timer module,5−100s,off−delayed Cannot be combined with front mounting auxiliary contact modules, inclusive suppressors Ordering information Description 100 . 130 V AC For use with DILM7 – DILM32
|
Original
|
dilm32-xted11-100rac1305-100sdilm32+8dilmp20d-53115hpl-c2007gmoellerstr z2062100stimer data sheetc2007g
|
PDF
|
DILMP125
Abstract: DILM17 Suppressor DILM150 contactor VOLTAGE SUPPRESSOR C2007G DILM115 DILM32 DILMP32
Contextual Info: Type: DILM32−XSPVL240 Article No.: 281223 Sales text Varistor−suppressor with LED f. DILM17. Ordering information Voltage For use with Us V 130 – 240 AC DILM17 – DILM32 DILMP32 DILMP45 Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
|
Original
|
dilm32-xspvl240dilm17dilm32dilmp32+9dilmp45dilm115dilm150dilmp125d-53115suppressorcontactorvoltage suppressorc2007g
|
PDF
|
DILM32-XSPR240
Abstract: contactor dilm150 VOLTAGE SUPPRESSOR C2007G DILM115 DILM32 DILMP125 XSPR240
Contextual Info: Type: DILM32−XSPR240 Article No.: 281203 Sales text RC−suppressor f. DILM17.32 Ordering information Voltage For use with Us V 110 – 240 AC DILM17 – DILM32 DILMP32 DILMP45 Contact sequence Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
|
Original
|
dilm32-xspr240dilm17dilm32dilmp32+9dilmp45dilm115dilm150dilmp125d-53115contactorvoltage suppressorc2007gxspr240
|
PDF
|
DILM32-10
Abstract: DILM32
Contextual Info: Type: DILM32−10 110V50HZ,120V60HZ Article No.: 277257 Ordering information Rated operational current AC−3 400 V Ie A 32 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 10 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
|
Original
|
dilm32-10110v50hz120v60hzd-53115+2hpl-c2005gb-intdilm32
|
PDF
|
ZB32-XEZ
Abstract: SDAINLM55 ZB32-16 DILM32 sdainlm30 500VIE
Contextual Info: Type: ZB32−16 Article No.: 278452 Ordering information Overload release, min. – max. Ir A 10 – 16 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
|
Original
|
zb32-16dilm17dilm25dilm32+8diulm17diulm25diulm32sdainlm30sdainlm45sdainlm55zb32-xez500vie
|
PDF
|