Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CAN404 Search Results

    CAN404 Datasheets (2)

    Analog Microelectronics
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    CAN404
    Analog Microelectronics Converter IC for Capacitive Signals Original PDF 44.01KB 8
    CAN404
    Analog Microelectronics Converter IC for Capacitive Signals with voltage output CAV404 Original PDF 78.2KB 6

    CAN404 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    CAV414

    Abstract: AM-422 nf schaltungen AM422 CAN404 namur output
    Contextual Info: Schnittstellen–ASICs für die kapazitive Meßtechnik CAN404 und CAV414 Der Druck ist neben der Temperatur eine der wichtigsten physikalischen Größen in der Prozeßmeßtechnik. Entsprechend groß ist die Vielfalt der verwendeten Sensorprinzipien. Neben den piezoresistiven Systemen findet man auch solche, die z.B. nach dem induktiven oder kapazitiven Prinzip


    Original
    can404cav414de/german/products/cav414am-422+3nf schaltungenam422namur output PDF

    namur output

    Abstract: R01 filters CAN404 SO20
    Contextual Info: Converter IC for Capacitive Signals CAN404 FEATURES GENERAL DESCRIPTION • Wide Supply Voltage Range: 5.18V • Wide Operating Temperature Range: –25°C.+85°C • High Detection Sensivity of Relative Capacitive Changes: 5% – 100% • Detection Frequency up to 2kHz


    Original
    can404namur outputr01 filtersso20 PDF

    CAN404

    Contextual Info: APPLICATION NOTE CAN404 Functional Description The functional description gives the necessary formulas to calculate the system. The formulas give a good approximation of the reality. Reference Oscillator: The reference oscillator works by charging and discharging the external oscillator capacitor COSC ,


    Original
    can404 PDF

    water level sensor schematic diagram

    Abstract: capacitive sensor for water level measurement schematic inductive sensor capacitive level sensor circuit drawing CAV414 capacitive level sensor circuit diagram water level sensor circuit schematic level water namur standard AM-422
    Contextual Info: Interface ICs for Capacitive Measurement Technology CAN404 and CAV414 Together with temperature, pressure is one of the most significant physical quantities in process measurement technology. Correspondingly, the range of sensor principles currently in use is large. In


    Original
    can404cav414water level sensor schematic diagramcapacitive sensor for water level measurement+7schematic inductive sensorcapacitive level sensor circuit drawingcapacitive level sensorcircuit diagram water level sensorcircuit schematic level waternamur standardam-422 PDF

    namur standard

    Abstract: namur output CAN404 SO20
    Contextual Info: Converter IC for Capacitive Signals CAN404 FEATURES GENERAL DESCRIPTION • Wide Supply Voltage Range: 5.18V • Wide Operating Temperature Range: –25°C.+85°C • High Detection Sensivity of Relative Capacitive Changes: 5% – 100% • Detection Frequency up to 2kHz


    Original
    can404namur standardnamur outputso20 PDF

    namur-ausgang

    Abstract: CAN404 namur output 20-Pin-DIL SO20 RCX2
    Contextual Info: Wandler–IC für kapazitive Signale CAN404 EIGENSCHAFTEN ALLGEMEINE BESCHREIBUNG • Großer Versorgungsspannungsbereich: 5.18V • Großer Temperaturbereich: –25°C.+85°C • Große Detektionsempfindlichkeit für relative Kapazitätsänderungen: 5% – 100%


    Original
    can404namur-ausgangnamur output20-pin-dil+2so20rcx2 PDF

    AM402

    Abstract: ANALOGE kor 2001 AM400 CAN404 CAV414
    Contextual Info: Signalauswerteschaltungen für Sensoren "Frame–ASICs*" oder die Modulare Signalauswertung Sensorsignale sind von Natur aus fehlerbehaftet und müssen mit geeigneten Methoden so korrigiert werden, daß bestimmte Fehlergrenzen eingehalten werden. Eine Methode ist, mit Hilfe von digitalen Komponenten das Sensorsignal zu kalibrieren und zu kompensieren. Auf dem Markt existieren eine Reihe von integrierten Lösungen, die eine solche elektronische Korrektur erlauben. Meist sind


    Original
    am400de/products/sheets/german/am400am402analoge+3kor 2001can404cav414 PDF

    Surround processor schematic

    Abstract: "Signal Conditioning" AM402 pressure sensor signal conditioning AM400 analog sensor CAN404 CAV414 monolithic amplifier MAR namur standard
    Contextual Info: Signal Conditioning Circuits for Sensors Frame ASICs* or Modular Signal Conditioning Sensor signals are, by their nature, not perfect and must be corrected with suitable techniques in such a way that target error levels are achieved. One method is to calibrate and compensate the sensor signal with aid of digital components. On the market, there are a few existing integrated solutions which allow such an electronic correction. But often these ICs are not flexible enough or simply not practical to use in


    Original
    am400de/products/sheets/english/am400surround processor schematicsignal conditioning+7am402pressure sensor signal conditioninganalog sensorcan404cav414monolithic amplifier marnamur standard PDF

    instrumentation amplifier for capacitive sensors

    Abstract: precision 4-20ma current source Voltage to Current Converter circuit 4-20mA Current to Voltage Converter 4-20mA Voltage to Current Converter 4-20mA ANALOG MICROELECTRONICS Voltage-to-Current Converter 4-20mA voltage to current converter 4 to 20ma circuit current to voltage converter namur driver
    Contextual Info: analog microelectronics PRODUCT GUIDE Standard ICs Sensor Transmitter ICs Amplifier and Protection ICs Voltage-to-Current Converter ICs Voltage-to-Voltage Converter ICs Converter ICs for Capacitive Signals Converter ICs for Single Ended Signals Special Protection Function ICs


    Original
    instrumentation amplifier for capacitive sensorsprecision 4-20ma current sourcevoltage to current converter circuit 4-20macurrent to voltage converter 4-20ma+6voltage to current converter 4-20maanalog microelectronicsvoltage-to-current converter 4-20mavoltage to current converter 4 to 20ma circuitcurrent to voltage converternamur driver PDF

    stromquelle

    Abstract: 4 bis 20 mA stromquelle AM417 AM432 dil16 0-10V 4.....20MA AM402 CAV424 AM400 SO16
    Contextual Info: analog microelectronics PRODUKTFÜHRER Standard-ICs Sensor-Transmitter-ICs Verstärker- und Schutz-ICs Spannungs-/Strom-Wandler-ICs Spannungs-/Spannungs-Wandler-ICs Wandler-ICs für kapazitive Signale Wandler-ICs für massebezogene Signale Spezielle Schutz- und Treiber-ICs


    Original
    am400am40oktober201108sstromquelle+84 bis 20 ma stromquelleam417am432dil160-10v 4.....20maam402cav424so16 PDF

    small capacitive oil level sensor

    Abstract: water level sensor schematic diagram moisture measurement capacitive sensor AM402 10-farad CAV424 PR1008 R01 filters AM337 AM401
    Contextual Info: Conversion of capacitive signals with the aid of IC CAV424 In order to condition signals from capacitive sensing elements used to measure moisture, acceleration, levels and angles, to date systems designers have had to rely primarily on discrete circuits or have customer-specific ICs CSICs developed. The many areas and applications


    Original
    cav424pr1007pr1008small capacitive oil level sensor+7water level sensor schematic diagrammoisture measurement capacitive sensoram40210-faradr01 filtersam337am401 PDF

    cav414

    Abstract: Surround processor schematic AM402 CAN404 "Signal Conditioning" AM400 analog sensor namur output
    Contextual Info: Signal Conditioning Circuits for Sensors Frame ASICs* or Modular Signal Conditioning Sensor signals are, by their nature, not perfect and must be corrected with suitable techniques in such a way that target error levels are achieved. One method is to calibrate and compensate the sensor signal with digital components. On the market,


    Original
    am400cav414surround processor schematicam402+4can404signal conditioninganalog sensornamur output PDF

    PR1008

    Abstract: AM402 digitale schaltungen AM400 AM401 AM411 AM417 AM427 CAN404 CAV414
    Contextual Info: Wandlung kapazitiver Signale mit Hilfe des ICs CAV424 Für die Signalauswertung von kapazitiven Meßzellen im Bereich der Feuchtemessung, der Füllstandsanzeige, der Beschleunigungs- und Winkelmessung mußten Entwickler bisher weitgehend auf diskrete Schaltungen zurückgreifen oder kundenspezifische ICs


    Original
    cav424pr1007pr1008am402+8digitale schaltungenam400am401am411am417am427can404cav414 PDF

    AM402

    Abstract: CAV414 attiny 85 pwm AM422 CAN404 adjustable zero span amplifier ic
    Contextual Info: Digital correction of capacitive signals with the aid of Frame ASIC CAV414 Measurements and readings are never completely accurate and must always be corrected using suitable methods in order to keep within the required error margins. One modern approach is to calibrate and compensate the measured sensor signal with the aid of correction algorithms implemented by a processor. There are integrated solutions currently


    Original
    cav414de/products/info/german/pr1007de/products/sheets/english/cav414de/products/sheets/german/appli414+6am402de/products/sheets/english/appli414attiny 85 pwmam422can404adjustable zero span amplifier ic PDF