Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    9001REGISTERED Search Results

    9001REGISTERED Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: TM MI - RAM Military COTS Ripple Attenuator Modules Features Reduces output PARD to <10 mV pp 93%-99% efficiency Full attenuation up to 20 A load Converter sense, trim, OV and OC retained Compatible with all MI-Series units from 5 to 50 Vdc output MIL-STD-810 environments


    Original
    mil-std-810 PDF

    Contextual Info: MI-200 Military High-Density DC-DC Converters 50 to 100W Product Highlights The MI Series is designed for Military applications and is based on Vicor‘s second generation family of zero-currentswitching, component level DC-DC converters. Operating at frequencies in


    Original
    mi-200tmmil-i-452089001-registeredmil-std-810+2trimming/program15mi-200 PDF

    MI-200

    Abstract: MI-J00
    Contextual Info: 12 MI-200 Military High Density DC-DC Converters 50 to 100 Watts Features • Inputs: 28 Vdc per MIL-STD-704D 155 Vdc per MIL-STD-1399A 270 Vdc per MIL-STD-704D ■ Any Output: 1 to 95 Vdc ■ Up to 23 Watts/cubic inch ■ MIL-STD-810 Environments ■ 80-90% Efficiency


    Original
    mi-200tmmil-std-704dmil-std-1399amil-std-810+3efficieil-std-1275ami-200mi-j00 PDF

    MI-J00

    Abstract: P4855-1
    Contextual Info: 12 MI-J00 Military DC-DC Converters 10 to 50 Watts Features • 28V& 270V MIL-STD-704D Inputs ■ 155V MIL-STD-1399A Input ■ Up to 23 Watts/cubic inch ■ 10, 25 and 50W Outputs ■ Environments to MIL-STD-810 ■ 80-90% Efficiency ■ Size: 2.28" x 2.4" x 0.5"


    Original
    mi-j00tmmil-std-704dmil-std-1399amil-std-810+5mi-j00mil-std-461mil-std-704amil-std-1275ap4855-1 PDF

    Contextual Info: MI - RAM TM Military Ripple Attenuator Modules Features Reduces output PARD to <10mV pp 93%-99% efficiency Full attenuation up to 20A load Converter sense, trim, OV and OC retained Compatible with all MI-Series units from 5 to 50Vdc output MIL-STD-810 environments


    Original
    50vdcmil-std-81020mhzpowe200 PDF

    Contextual Info: MI-200 TM Military COTS DC-DC Converters 50 to 100 W Features Inputs: 28 Vdc per MIL-STD-704D/E/F 155 Vdc per MIL-STD-1399A 270 Vdc per MIL-STD-704D/E/F Current limit Single output: 2 – 48 Vdc ZVS/ZCS power architecture Up to 23 W/in3 Low noise FM control


    Original
    mi-200mil-std-704d/e/fmil-std-1399amil-std-810 PDF

    P-4855-1A

    Contextual Info: TM MI-200 Military COTS DC-DC Converters 50 to 100 W Features Inputs: 28 Vdc per MIL-STD-704D/E/F 155 Vdc per MIL-STD-1399A 270 Vdc per MIL-STD-704D/E/F Current limit Single output: 2 – 48 Vdc ZVS/ZCS power architecture Up to 23 W/in3 Low noise FM control


    Original
    mi-200mil-std-704d/e/fmil-std-1399amil-std-810+1p-4855-1a PDF

    270vdc

    Contextual Info: MI-JOO TM M ilitary DC-DC Converters 10 to SOW Features Inputs: © 28VdC p e r MIL-STD-704D/E 155V dc p e r MIL-STD-1399A 270Vdc per MIL-STD-704D/E O R em ote sense © Current limit © Single o u tp u t: 2 - 48V dc © Up to 23W /ln3 © MIL-STD-810 environm ents


    OCR Scan
    28vdcmil-std-704d/emil-std-1399a270vdc+3mil-std-810p-4855-1ap-4855-1 PDF

    8551a

    Abstract: s9411 at38w MI-J00
    Contextual Info: VICOR MI-JOO Converter Selection Chart M I-JH Military D C-D C Converters 10 to 50 Watts 2 = Features 5 = 155V 1 0 0 - 210V 6 = 270V 1 2 5 - 4 0 0V 2 7 = 165V 1 0 0 - 310V • 28V& 270V MIL-STD-704D Inputs ■ 155V DOD-STD-1399A Input ■ U p to 23 W a tts/cu b ic inch


    OCR Scan
    mil-std-704ddod-std-1399amil-std-810mil-std-461+6mil-std-704amil-std-1275a8551as9411at38wmi-j00 PDF

    MI-200

    Contextual Info: MI-200 TM Military DC-DC Converters 50 to 100W Features Current limit Inputs: 28Vdc per MIL-STD-704D/E 155Vdc per MIL-STD-1399A 270Vdc per MIL-STD-704D/E OVP and thermal shutdown Single output: 2 – 48Vdc Power boosters for higher power outputs Up to 23W/in3


    Original
    mi-20028vdcmil-std-704d/e155vdc+4mil-std-1399a270vdc48vdcmil-std-810 PDF

    Contextual Info: TM MI - RAM Military Ripple Attenuator Modules Features Reduces output PARD to <10mV pp 93%-99% efficiency Full attenuation up to 20A load Converter sense, trim, OV and OC retained Compatible with all MI-Series units from 5 to 50Vdc output MIL-STD-810 environments


    Original
    50vdcmil-std-81020mhzvi-200/mi-200 PDF

    Contextual Info: MI-200 TM Military DC-DC Converters 50 to 100W Features Current limit Inputs: 28Vdc per MIL-STD-704D/E 155Vdc per DOD-STD-1399A 270Vdc per MIL-STD-704D/E OVP and thermal shutdown Single output: 1 – 95Vdc Power boosters for higher power outputs Up to 23W/in3


    Original
    mi-20028vdcmil-std-704d/e155vdc+4dod-std-1399a270vdc95vdcmil-std-810 PDF

    MI-J00

    Contextual Info: MI-J00 TM Military COTS DC-DC Converters 10 to 50 W Features Up to 90% efficiency Inputs: 28 Vdc per MIL-STD-704D/E/F 155 Vdc per MIL-STD-1399A 270 Vdc per MIL-STD-704D/E/F Remote sense Current limit ZVS/ZCS power architecture Single output: 2 – 48 Vdc Low noise FM control


    Original
    mi-j00mil-std-704d/e/fmil-std-1399amil-std-810 PDF

    MIL-STD-704A

    Contextual Info: MI - AIM TM Military Component Front End Modules Features MIL-STD-704A input transient protection Inputs: 115Vac; 60/400Hz Output power: 250W Compatible with MI-x7x family modules 95% efficiency MIL-STD-461D EMI compliance Size: 2.28" x 2.4" x 0.5" 57,9 x 61,0 x 12,7mm


    Original
    115vac60/400hzmil-std-704amil-std-461d+3mil-std-810ce102milstd-461d PDF

    MI-RAM-M1

    Contextual Info: All^ V fC Q fì MI-RAM Military Ripple Attenuator Modules Features • R educes O utput PARD to <10 mV p-p ■ C om patible w ith All MI Series U nits MI-RAM Specifications typical at T qp = 25°C, nominal line, 75% load unless otherwise specified PARAMETER


    OCR Scan
    mi-200mi-j00mi-ram-11mil-std-461+4mil-std-704ail-std-1275amil-std-810mi-ram-m1 PDF

    P4855-1

    Abstract: P-4855-1
    Contextual Info: M I - 2 ” M ilitary DC-DC Converters 50 to 100W Features o Current limit Inputs: 28Vdc per MIL-STD-704D/E 155Vdc per MIL-STD-1399A 270Vdc per MIL-STD-704D/E © OVP and thermal shutdown © Power boosters for higher power outputs © Single output: 2 - 48Vdc


    OCR Scan
    28vdcmil-std-704d/e155vdcmil-std-1399a+5270vdc48vdcmil-std-810p-4855-1p4855-1 PDF

    P-4855-1A

    Abstract: MIL-STD-704D MI-200 zero-voltage-switch
    Contextual Info: MI-200 TM Military DC-DC Converters 50 to 100W Features Current limit Inputs: 28Vdc per MIL-STD-704D/E 155Vdc per DOD-STD-1399A 270Vdc per MIL-STD-704D/E OVP and thermal shutdown Single output: 1 – 95Vdc Power boosters for higher power outputs Up to 23W/in3


    Original
    mi-20028vdcmil-std-704d/e155vdc+7dod-std-1399a270vdc95vdcmil-std-810p-4855-1amil-std-704dzero-voltage-switch PDF

    MI-200

    Abstract: MI-J00
    Contextual Info: TM MI - RAM Military COTS Ripple Attenuator Modules Features Reduces output PARD to <10 mV pp 93%-99% efficiency Full attenuation up to 20 A load Converter sense, trim, OV and OC retained Compatible with all MI-Series units from 5 to 50 Vdc output MIL-STD-810 environments


    Original
    mil-std-810mi-200mi-j00 PDF

    MIL-STD-704A

    Abstract: CE102
    Contextual Info: MI - AIM TM Military COTS Component Front-end Modules Features MIL-STD-704A input transient protection Inputs: 115 Vac; 60/400 Hz Output power: 250 W 95% efficiency Compatible with MI-x7x family modules Operating temperature to 100°C Size: 2.28" x 2.4" x 0.5"


    Original
    mil-std-704amil-std-461d/emil-std-810ce102 PDF

    MI-J00

    Contextual Info: MI-J00 TM Military COTS DC-DC Converters 10 to 50 W Features Up to 90% efficiency Inputs: 28 Vdc per MIL-STD-704D/E 155 Vdc per MIL-STD-1399A 270 Vdc per MIL-STD-704D/E Remote sense Current limit ZVS/ZCS power architecture Single output: 2 – 48 Vdc Low noise FM control


    Original
    mi-j00mil-std-704d/emil-std-1399amil-std-810+2std-810855-1a PDF

    Contextual Info: TM MI - RAM Military Ripple Attenuator Modules Features Reduces output PARD to <10mV pp 93%-99% efficiency Full attenuation up to 20A load Converter sense, trim, OV and OC retained Compatible with all MI-Series units from 5 to 50Vdc output MIL-STD-810 environments


    Original
    50vdcmil-std-81020mhz PDF

    Contextual Info: MI - AIM TM Military COTS Component Front-end Modules Features MIL-STD-704A input transient protection Inputs: 115 Vac; 60/400 Hz Output power: 250 W 95% efficiency Compatible with MI-x7x family modules Operating temperature to 100°C Size: 2.28" x 2.4" x 0.5"


    Original
    mil-std-704amil-std-461dmil-std-810ce102+1milstd-461d PDF

    MI-J00

    Abstract: MIL-STD-810 altitude test MIL-STD-1399 MIL-STD-704D NAVMAT 4855 MIL-STD-704D. Input Transient
    Contextual Info: MI-J00 TM Military DC-DC Converters 10 to 50W Features Up to 90% efficiency Inputs: 28Vdc per MIL-STD-704D/E 155Vdc per MIL-STD-1399A 270Vdc per MIL-STD-704D/E Remote sense Current limit ZVS/ZCS power architecture Single output: 2 – 48Vdc Low noise FM control


    Original
    mi-j0028vdcmil-std-704d/e155vdc+9mil-std-1399a270vdc48vdcmil-std-810mil-std-810 altitude testmil-std-1399mil-std-704dnavmat 4855mil-std-704d. input transient PDF

    MI-200

    Contextual Info: MI-200 TM Military COTS DC-DC Converters 50 to 100 W Features Inputs: 28 Vdc per MIL-STD-704D/E 155 Vdc per MIL-STD-1399A 270 Vdc per MIL-STD-704D/E Current limit Single output: 2 – 48 Vdc ZVS/ZCS power architecture Up to 23 W/in3 Low noise FM control MIL-STD-810 environments


    Original
    mi-200mil-std-704d/emil-std-1399amil-std-810 PDF