505 TRANSFORMER Search Results
505 TRANSFORMER Result Highlights (1)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TUSS4440TRTJT | Texas Instruments | Transformer drive ultrasonic sensor IC with logarithmic amplifier |
|
|
Documents mentioning 505 TRANSFORMER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| smd transformer | 10/100 BASE-T PC CARD SMD TRANSFORMER MODULE ALAN-505 RoHS 12.7 x 7.1 x 1.98mm Compliant | | | | | | | | | | | | | | | STANDARD SPECIFICATIONS: Parameters Minimum Operating Temperature Typical Insertion Loss Maximum Units +70 °C 0.9 dB 16 Return Loss Cross Talk |
Original | ||||
| raica | Breaker-failure protection RAICA 1MRK 505 005-BEN Page 1 Issued October 1999 Changed since June 1999 Data subject to change without notice (SE980072) Features • Provides local back-up protection when the primary breaker fails to operate • Insensitive to current transformer saturation and transients |
Original | ||||
| reb 670 | Busbar differential protection IED REB 670 Buyer's Guide Pre-configured 1MRK 505 172-BEN Revision: A Issued: February 2007 Data subject to change without notice Page 1 Features • IED for differential protection of busbars, meshed corners and T-protection |
Original | ||||
| 3URWHFW,7 %UHDNHU SURWHFWLRQ DQG FRQWURO WHUPLQDO | 3URWHFW,7 %UHDNHU SURWHFWLRQ DQG FRQWURO WHUPLQDO IRU EUHDNHU V\VWHPV )HDWXUHV • Pre-configured protection terminal for costeffective engineering and commissioning • Ready to connect and commission for maximum cost saving benefit 1MRK 505 118-BEN |
Original | ||||
| Line differential protection IED RED 670 Buyer's | Line differential protection IED RED 670 Buyer's Guide Open Configuration 1MRK 505 137-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration |
Original | ||||
| radss | Busbar protection with auxiliary summation CT’s RADSS 1-phase 1MRK 505 009-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE980086) Features • Percentage restrained bus differential relay for phase and earth faults |
Original | ||||
| %UHDNHU SURWHFWLRQ WHUPLQDO 5(% 1MRK 505 | %UHDNHU SURWHFWLRQ WHUPLQDO 5(% 1MRK 505 093-BEN Page 1 Revision: Issued: March 2003 Data subject to change without notice )HDWXUHV • Open terminal with extensive configuration possibilities and expandable hardware design to meet specific user requirements |
Original | ||||
| 164-ben | Line differential protection IED RED 670 Buyer's Guide Pre-configured 1MRK 505 164-BEN Revision: G Issued: February 2007 Data subject to change without notice Page 1 Features • Four configuration alternatives for single- or multi-breaker arrangements available – ready to |
Original | ||||
| reb 551 | A l l l i REB 551 * 1.2 Breaker protection terminal ■ , 1MRK 505 001-BEN ■- Changed since October 1997 Data subject to change without notice ABB Network Partner (SE950214) Features • Breaker related protection and associated func tions in a numerical unit |
OCR Scan | ||||
| REB 103 and REB 101 1wirk 505 002-BEN Busbar | REB 103 and REB 101 1wirk 505 002-BEN Busbar protection Page 1 November 1995 Changed since March 1992 Replaces 1MDB05006-EN Data subject to change without notice ABB Network Partner (SE 90 00 20) Features • Based upon a previous design with long experience |
OCR Scan | ||||
| breaker failure relay | Breaker failure relay REB 010 1MRK 505 004-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970138) Features • Local redundant protection when the circuit breaker does not operate • The technique with microprocessors |
Original | ||||
| 187-bus | Line differential protection IED RED 670 Buyer's Guide Customized 1MRK 505 187-BUS Product version: 1.1 Revision: A Issued: November 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration |
Original | ||||
| 50msm16p | 50MIL SM16 PINS PACKAGE PHYSICAL DIMENSIONS All dimensions in inches (mm): .505 (12.83) .285 (7.24) MAX. MAX. .205 (5.21) MAX. .016 (0.41) TYP. .050 (1.27) .015 (0.38) TYP. TYP. .025 (0.64) TYP. .010 (0.25) TYP. .380 (9.65) .360 (9.14) 50MSM16P Rhombus Industries Inc. |
Original | ||||
| Bus differential relay using auxiliary summation | Bus differential relay using auxiliary summation CT’s REB 101 1-phase 1MRK 505 006-BEN Page 1 Issued: September 2006 Revision: C Data subject to change without notice (SE970178) Features • Percentage restrained differential relay for phase-to-phase and phase-to-earth faults |
Original | ||||
|
|
||||||
| radss | Busbar differential protection RADSS 3-phase 1MRK 505 008-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE 81 02 58) (SE 81 02 60) Features • Percentage restrained bus differential relay for phase and earth faults |
Original | ||||
| 3URWHFW,7 %UHDNHU SURWHFWLRQ DQG FRQWURO WHUPLQDO | 3URWHFW,7 %UHDNHU SURWHFWLRQ DQG FRQWURO WHUPLQDO 5(% & 1MRK 505 113-BEN Page 1 Revision: – Issued: October 2003 Data subject to change without notice )HDWXUHV • Pre-configured protection terminal for costeffective engineering and commissioning |
Original | ||||
| $XWRPDWLF 5HFORVLQJ 7HPLQDO ZLWK 6\QFKURFKHFN 5(% | $XWRPDWLF 5HFORVLQJ 7HPLQDO ZLWK 6\QFKURFKHFN 5(% & 1MRK 505 095-BEN Page 1 Revision: Issued: March 2003 Data subject to change without notice )HDWXUHV • Secondary system supervision - Fuse failure supervision (FUSE) • Control - Synchrocheck (SYN) |
Original | ||||
| *HQHUDO GLIIHUHQWLDO SURWHFWLRQ 5(' 1MRK | *HQHUDO GLIIHUHQWLDO SURWHFWLRQ 5(' 1MRK 505 031-BEN Page 1 Revision B Issued: November 2003 Data subject to change without notice Three-Phase Terminal )HDWXUHV Three One-Phase Terminals • High speed general differential protection. Minimal operating time around 10 ms |
Original | ||||
| 3URWHFW,7 %UHDNHU SURWHFWLRQ WHUPLQDO 5(% | 3URWHFW,7 %UHDNHU SURWHFWLRQ WHUPLQDO 5(% 1MRK 505 098-BEN Page 1 Revision: B Issued: November 2003 Data subject to change without notice )HDWXUHV • A terminal with extensive configuration possibilities and expandable hardware design to meet specific user requirements |
Original | ||||
| 5 4 3 2 1 +VDDIO_CLK U21 +3V +1.05V +3V_CLK L28 | 5 4 3 2 1 +VDDIO_CLK U21 +3V +1.05V +3V_CLK L28 C303 C293 C297 C299 C298 C285 4.7U/10V_8 4.7U/10V_8 .1u/16V_4.1u/16V_4.1u/16V_4.1u/16V_4 C302 .1u/16V_4 XTAL_OUT XTAL_IN R199 10 CLK_ICH_14M 33_4 Place the 33 ohm resistors close to the CK 505 C CPU_SEL CLK_SDATA |
Original | ||||