| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| 73725-0010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 73725-1010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 72313-4010BPLF | Amphenol Communications Solutions | USB 2.0, Input Output Connector, Single Deck Receptacle, Type A, Through Hole, Right Angle, 4 Positions with Sensor Contact |
Documents mentioning 4-ELECTRODE GAS SENSOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| an-1798 | ANALOG edge SM Designing with Electro-chemical Sensors Application Note AN-1798 Muna Acosta, Applications Engineer As early as 1950, electro-chemical sensors were used for oxygen (gas) monitoring; however, with increasing concerns about personal safety, the demand for portable |
Original | ||||
| electrochemical | National Semiconductor Application Note 1798 Muna Acosta June 24, 2008 As early as 1950, electro-chemical sensors were used for oxygen (gas) monitoring; however, with increasing concerns about personal safety, the demand for portable electro-chemical sensors has dramatically increased. Today, electrochemical sensors are commonly used in portable equipment |
Original | ||||
| lmp91002 | LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91002 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output |
Original | ||||
| potentiostat | LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91002 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output |
Original | ||||
| lmp9100 | LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor |
Original | ||||
| LMP91000 Sensor AFE System: Configurable AFE | LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor |
Original | ||||
| lmp9100 | LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor |
Original | ||||
| LMP91000 Sensor AFE System: Configurable AFE | LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor |
Original | ||||
| mq-5 | HANWEI ELECTRONICS CO.,LTD TECHNICAL MQ-5 http://www.hwsensor.com DATA MQ-5 GAS SENSOR FEATURES * High sensitivity to LPG, natural gas , town gas * Small sensitivity to alcohol, smoke. * Fast response . * Stable and long life * Simple drive circuit APPLICATION |
Original | ||||
| mq-5 | HANWEI ELECTRONICS CO.,LTD TECHNICAL MQ-5 http://www.hwsensor.com DATA MQ-5 GAS SENSOR FEATURES * High sensitivity to LPG, natural gas , town gas * Small sensitivity to alcohol, smoke. * Fast response . * Stable and long life * Simple drive circuit APPLICATION |
Original | ||||
| HANWEI ELECTRONICS CO.,LTD MQ-5 | HANWEI ELECTRONICS CO.,LTD MQ-5 http://www.hwsensor.com TECHNICAL DATA MQ-5 GAS SENSOR FEATURES * High sensitivity to LPG, natural gas , town gas * Small sensitivity to alcohol, smoke. * Fast response . * Stable and long life * Simple drive circuit APPLICATION |
Original | ||||
| lmp91002 | LMP91002 www.ti.com SNIS163 – APRIL 2012 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End |
Original | ||||
| figaro | FIGARO PRODUCT INFORMATION TGS 4161 - for the detection of Carbon Dioxide Features: Applications: * High selectivity to CO2 * Compact size * Low dependency on humidity * Long life and low cost * Low power consumption * Indoor air quality control TGS4161 is a new solid electrolyte CO2 sensor which offers miniaturization and |
Original | ||||
| LMP91002 www.ti.com SNIS163A – APRIL 2012 – | LMP91002 www.ti.com SNIS163A – APRIL 2012 – REVISED MARCH 2013 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End |
Original | ||||
|
|
||||||
| lmp9100 | LMP91002 www.ti.com SNIS163A – APRIL 2012 – REVISED MARCH 2013 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End |
Original | ||||
| LMP91002 www.ti.com SNIS163A – APRIL 2012 – | LMP91002 www.ti.com SNIS163A – APRIL 2012 – REVISED MARCH 2013 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End |
Original | ||||
| sb-95 | for CARBON MONOXIDE AND METHANE DETECTION General The SB-95 is a tin dioxide semiconductor gas sensor which has an excellent performance in detecting both CO and methane selectively with single sensor element. This unique feature was realized by using a mini-bead type |
Original | ||||
| lmp9100 | LMP91000 www.ti.com SNAS506H – JANUARY 2011 – REVISED MARCH 2013 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES DESCRIPTION • The LMP91000 is a programmable Analog Front End |
Original | ||||
| lmp9100 | LMP91000 www.ti.com SNAS506G – JANUARY 2011 – REVISED FEBRUARY 2012 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES 1 • 23 • Typical Values, TA = 25°C |
Original | ||||
| LMP91000 www.ti.com SNAS506H – JANUARY 2011 – | LMP91000 www.ti.com SNAS506H – JANUARY 2011 – REVISED MARCH 2013 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES 1 • 23 • Typical Values, TA = 25°C |
Original | ||||
| LMP91000 www.ti.com SNAS506H – JANUARY 2011 – | LMP91000 www.ti.com SNAS506H – JANUARY 2011 – REVISED MARCH 2013 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES 1 • 23 • Typical Values, TA = 25°C |
Original | ||||
| mq-2 | HANWEI ELETRONICS CO.,LTD TECHNICAL MQ-2 DATA http://www.hwsensor.com MQ-2 GAS SENSOR FEATURES Wide detecting scope Fast response and High sensitivity Stable and long life Simple drive circuit APPLICATION They are used in gas leakage detecting equipments in family and industry, are suitable for detecting |
Original | ||||
| mq-131 | TECHNICAL DATA MQ-131 GAS SENSOR FEATURES Fast response and High sensitivity Stable and long life Simple drive circuit Wide detecting range APPLICATION They are used in air quality control equipments for buildings/offices, are suitable for detecting Of O3 . |
Original | ||||
| mq-2 | HANWEI ELETRONICS CO.,LTD TECHNICAL MQ-2 DATA http://www.hwsensor.com MQ-2 GAS SENSOR FEATURES Wide detecting scope Fast response and High sensitivity Stable and long life Simple drive circuit APPLICATION They are used in gas leakage detecting equipments in family and industry, are suitable for detecting |