| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| MCFG Series Transformer Specifications Secondary | MCFG Series Transformer Specifications Secondary Volts (V) Secondary Amps (A) 6 + 6 at 15VA 1.25 MCFG015/06 9 + 9 at 15VA 0.83 MCFG015/09 12 + 12 at 15VA 0.63 15 + 15 at 15VA 0.50 MCFG015/15 18 + 18 at 15VA 0.42 MCFG015/18 6 + 6 at 30VA 2.50 9 + 9 at 30VA |
Original | ||||
| DRG SERIES RING GENERATOR 3 0 VA k e y • f e a t | DRG SERIES RING GENERATOR 3 0 VA k e y • f e a t u r e s 30VA output power programmable frequency excellent efficiency low harmonic distortion • 6 sided shielding remote enable pin 500VDC isolation adjustable output voltage The DRG high power family of ring generators provide up to 30VA of output power at |
Original | ||||
| Transformers, Power Converters and UPS From Avel | Transformers, Power Converters and UPS From Avel Lindberg, Inc. http://www.avellindberg.com/transformers/d4000_range_specs.htm D4000 Standard Range Specifications - 30VA Load VA Secondary RMS V Secondary RMS Current Diameter mm Height mm Diameter Height Weight |
Original | ||||
| LAMINATED TRANSFORMERS Type UI39 / 21 - 30VA | LAMINATED TRANSFORMERS Type UI39 / 21 - 30VA AGENCY APPROVALS Primary (V) Secondary (V / mA) 2x115 2x115 1. UL 506, File E113449 V DE 3. EN61558 No-Load Voltage (V) Part Number Agency Approvals1 6/2500 / 6/2500 6.70/6.70 039-5302.0 1/3* 9/1666 / 9/1666 10.30/10.30 |
Original | ||||
| LAMINATED TRANSFORMERS Type UI39 / 21 - 30VA | LAMINATED TRANSFORMERS Type UI39 / 21 - 30VA AGENCY APPROVALS Primary (V) Secondary (V / mA) 2x115 2x115 1. UL 506, File E113449 V DE 3. EN61558 No-Load Voltage (V) Part Number Agency Approvals1 6/2500 / 6/2500 6.70/6.70 039-5302.0 1/3* 9/1666 / 9/1666 10.30/10.30 |
Original | ||||
| ui39 | LAMINATED TRANSFORMERS Type UI39 / 21 - 30VA AGENCY APPROVALS Primary (V) Secondary (V / mA) 2x115 2x115 1. UL 506, File E113449 V DE 3. EN61558 No-Load Voltage (V) Part Number Agency Approvals1 6/2500 / 6/2500 6.70/6.70 039-5302.0 1/3* 9/1666 / 9/1666 10.30/10.30 |
Original | ||||
| 44000 Series EI 66-23 (30VA) Sealed Power | 44000 Series EI 66-23 (30VA) Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216) |
Original | ||||
| Rating Output (V) Stock No. 15VA 6+6 9+ 9 12 + 12 | Rating Output (V) Stock No. 15VA 6+6 9+ 9 12 + 12 15 + 15 18 + 18 25 + 25 12000 12001 12002 12003 12004 12005 30VA 6+6 9+ 9 12 + 12 15 + 15 18 + 18 25 + 25 12010 12011 12012 12013 12014 12015 50VA 6+6 9+9 12 + 12 15 + 15 18 + 18 25 + 25 55 + 55 12020 12021 |
Original | ||||
| swg75 | PAGE 6 \ DC/DC CONVERTERS 3 Û. S o > o E O utput Power Series Page 10VA ; SWG10 ! 208 • 30VA SWG30 : 210 • 75VA SWG75 : 214 • 190 • AFC5 192 • 5 to 6W PM900 194 • 10 to 12W PM800 196 • N O M IN A L INPU T DC /D C 0.5 to 1W I PM600 |
OCR Scan | ||||
| swg30 | SWG30 SERIES DC/AC single output ring generator • Measuring just 4.00 x 4.00 x 0.63 inches, the SWG30 design maximizes efficiency, typically 80% at full load. Operating from any input voltage in the range 40 to 60VDC, the SWG30 features indefinite short circuit protection and |
Original | ||||
| SWG30 SERIES DC/AC single output ring generator • | SWG30 SERIES DC/AC single output ring generator • Measuring just 4.00 x 4.00 x 0.63 inches, the SWG30 design maximizes efficiency, typically 80% at full load. Operating from any input voltage in the range 40 to 60VDC, the SWG30 features indefinite short circuit protection and |
Original | ||||
| swg30 | V ARTESON T E C H N O L O B G I SWG30 SERIES E DC/AC single output ring generator S • M easuring ju s t 3.94 x 3.94 x 0.63 inches, th e SW G30 design m axim izes efficiency, typica lly 80% at full load. O perating from any input voltage in the |
OCR Scan | ||||
| ring generator | LOW COST 30 Watt Sine Wave Telephone Ring Generator 40REN@75Vrms to 100REN@45Vrms PDR-SIN30V48F25 PDR-SIN30V48F25 LOW COST 30 Watt Sine Wave Telephone Ring Generator FEATURES ! ! ! ! ! ! ! ! Supports 40 standard North American REN Overload control with constant output power |
Original | ||||
| swg75 | SWG75 SERIES DC/AC single output ring generator • Provides 75VA of ringer output power Typical efficiency 78% Short circuit protection Operating temperature up to 70°C Internal sine wave reference Remote ON/OFF control Opto-isolated cadencing ON/OFF control |
Original | ||||
|
|
||||||
| DRG Series of Telephone Ring Generators -48 VDC | DRG Series of Telephone Ring Generators -48 VDC Nominal Input Voltage 80% Minimum Efficiency Crystal Oscillator Time Base Sine Wave Output Low THD Fully Floating Output User Adjustable Output Voltage (optional) User Programmable Output Frequency (optional) |
OCR Scan | ||||
| bs7626 | W DATA SHEET Current Transformer 80 x 30, 1000A-2500A W SCHRACK-INFO • Passing bus bar primary Single-phase current transformer • Primary current 1000…2500A • Secondary current 5A W TECHNICAL DATA: REFERENCE STANDARDS EN60044-1, BS3938, BS7626 SPECIFICATIONS |
Original | ||||
| 30-40va | AHR Series 30-40VA Power Transformer PART NUMBERING SYSTEM AHR 40 309 FM QT XXXX Basic Series Designation VA Rating - See Below Primary and Secondary Voltages - See Below Mounting - See Below Termination - See Below Optional Customer Assign (XXXX) Part number ordering information. |
Original | ||||