Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    3 PHASE MONITORING RELAYS Search Results

    3 PHASE MONITORING RELAYS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    UHD508R/883C
    Rochester Electronics LLC UHD508 - Quad 2-Input NAND Power/Relay Driver. Dual marked (8550001CA) PDF Buy
    TB6586BFG
    Toshiba Electronic Devices & Storage Corporation Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave Datasheet
    TB62213AFG
    Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=3/Phase Interface Datasheet
    TB62261FTAG
    Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=1.5/Phase Interface Datasheet
    TB6562ANG
    Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=1.5/Phase Interface Datasheet

    3 PHASE MONITORING RELAYS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    K3YM400VSY20

    Abstract: 1000VA
    Contextual Info: K3YM400VSY20 Monitoring relays - KAPPA series Voltage monitoring in 3-phase- and 1-phase mains Multifunction Monitoring of phase failure and asymmetry Monitoring of phase sequence selectable Connection of neutral wire optional 2 change over contacts Plug-in housing


    Original
    K3YM400VSY20 400/230V K3YM400VSY20 1000VA PDF

    11-POL

    Abstract: 1000VA 230v 3 phase relay
    Contextual Info: K3PF400VSY02 Monitoring relays - KAPPA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Optional connection of neutral wire Supply voltage = measuring voltage 2 change over contacts Plug-in housing


    Original
    K3PF400VSY02 100ms 400/230V 11-POL 1000VA 230v 3 phase relay PDF

    E1PF400VSY01

    Abstract: phase failure phase sequence 1000VA three phase sequence
    Contextual Info: E1PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 1 change over contact Width 17.5mm Installation design


    Original
    100ms E1PF400VSY01 400/230V 340300A E1PF400VSY01 phase failure phase sequence 1000VA three phase sequence PDF

    1000VA

    Abstract: phase failure E3PF400VSY02 15 6KV
    Contextual Info: E3PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 2 change over contacts Width 35 mm Installation design


    Original
    100ms E3PF400VSY02 400/230V 1000VA phase failure E3PF400VSY02 15 6KV PDF

    G2PM400VSY10

    Abstract: G2PM115VSY10 G2PM230VSY10 1000VA SY10 phase failure relay 230v 3 phase relay
    Contextual Info: G2PM.SY10 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Supply voltage selectable via power modules


    Original
    G2PM400VSY10 G2PM115VSY10 G2PM230VSY10 1000VA SY10 phase failure relay 230v 3 phase relay PDF

    G4PM690VSYL20

    Abstract: G4PM500VSYL20 1000VA
    Contextual Info: G4PM.SYL20 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains for 500V resp. 690V Multifunction, fault latch Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire


    Original
    SYL20 G4PM690VSYL20 G4PM500VSYL20 103mm 1000VA PDF

    1000VA

    Abstract: relay 230v
    Contextual Info: G2PW.10 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Windowfunction Supply voltage selectable via power modules 1 change-over contact Width 22.5mm Industrial design Technical data 1. Functions Voltage monitoring in 3-phase mains monitoring the window between


    Original
    G2PW400V10 1000VA relay 230v PDF

    OF RELAY -5V, 230V INPUT

    Abstract: E3YF400V02 1000VA
    Contextual Info: E3YF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 2 change over contacts Width 35 mm Installation design Technical data 1. Functions Switching frequency: Undervoltage monitoring in 3-phase mains each phase against the neutral wire with fixed adjustable threshold and fixed adjustable hysteresis.


    Original
    200ms E3YF400V02 E3YF400VT02 400/230V OF RELAY -5V, 230V INPUT 1000VA PDF

    VDE0108

    Abstract: E1YU400V01 1000VA E1YF400V01
    Contextual Info: E1YF, E1YU Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions Undervoltage monitoring in 3-phase mains each phase against the neutral wire with fixed or variable threshold voltage US and fixed hysteresis.


    Original
    200ms E1YF400V01 E1YU400V01, E1YF400VT01 -400/230V VDE0108 340402A E1YU400V01 -400/230V VDE0108 E1YU400V01 1000VA PDF

    PPB01CM48

    Abstract: DPB01CM48 PB01CM48 DPB01CM48N PPB01 PPB01CM48N PB01CM23 PB01CM48W4 DPB01
    Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01 DPB01 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays • Detect when all 3 phases are present and have the correct phase sequence except for N versions


    Original
    DPB01, PPB01 DPB01 DPB01) PPB01CM48 DPB01CM48 PB01CM48 DPB01CM48N PPB01 PPB01CM48N PB01CM23 PB01CM48W4 DPB01 PDF

    DPC02

    Abstract: star delta wiring diagram power supply output 240 VAC
    Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Type DPC02 • TRMS 3-phase over and under voltage, over and under frequency, phase sequence and phase loss monitoring relay • Detect when all 3 phases are present and have the correct sequence


    Original
    DPC02 DPC02 star delta wiring diagram power supply output 240 VAC PDF

    DPC01DM69

    Abstract: DPC01 star delta wiring diagram 400HZ 400hz relay
    Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 DPC01 PPC01 • TRMS 3-phase over and under voltage, phase sequence, phase loss and asymmetry monitoring relay • Detect when all 3 phases are present and have the correct sequence


    Original
    DPC01, PPC01 DPC01 DPC01) PPC01) DPC01DM69 DPC01 star delta wiring diagram 400HZ 400hz relay PDF

    PPB01CM48

    Abstract: DPB01CM23 PPB01 DPB01CM48 star delta wiring diagram DPB01 phase failure relay 3 phase monitoring relays loss of neutral monitor marking L2 diode
    Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01 DPB01 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays • Detect when all 3 phases are present and have the correct phase sequence except for DPB01.N and


    Original
    DPB01, PPB01 DPB01 DPB01. PPB01. DPB01) PPB01) PPB01CM48 DPB01CM23 PPB01 DPB01CM48 star delta wiring diagram DPB01 phase failure relay 3 phase monitoring relays loss of neutral monitor marking L2 diode PDF

    DPB71

    Abstract: DPB71CM48 level alarm DPB71CM23
    Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Type DPB71 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relay • Detects when all 3 phases are present and have the correct phase sequence • Detects if all the 3-phase-phase or phase-neutral voltages are within the set limits


    Original
    DPB71 DPB71 DPB71CM48 level alarm DPB71CM23 PDF

    1000VA

    Abstract: E3YU400V02
    Contextual Info: E3YU400V02 Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = meased voltage 2 change over contacts Width 35 mm Installation design Technical data 1. Functions 7. Measuring circuit Undervoltage monitoring in 3-phase mains each phase against the neutral wire with adjustable threshold US and fixed adjustable hysteresis.


    Original
    E3YU400V02 200ms 400/230V 60-240V 1000VA E3YU400V02 PDF

    G2PM115VSY20

    Abstract: g2pm230vsy20 G2PM400VSY20 1000VA 24-240V SY20 n345 phase failure 3 phase monitoring relays
    Contextual Info: G2PM.SY20 24-240V Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Zoom voltage 24 to 240V AC/DC


    Original
    4-240V G2PM400VSY20 4-240V, 24VAC/DC G2PM115VSY20 g2pm230vsy20 1000VA 24-240V SY20 n345 phase failure 3 phase monitoring relays PDF

    MXP C 100 40 05

    Abstract: MXP A 100 49 10 MXP A 100 55 10 MXP A 100 40 05 MXP A 100 55 05 230v 3 phase relay MXP A 100 44 05 VDE0609-1 8A240VAC MCU10
    Contextual Info: Control & Monitoring Relays 3-Phase Monitoring Relay MXP-10 DESCRIPTION OPERATION A relay for monitoring a 3-phase AC power supply with or without Neutral. The relay monitors that all phases are available and in the correct phase sequence U,V,W , that none of the phases are


    Original
    MXP-10 115/3x230/3x400VAC) MXV-30 75kVAC EN60950) UL94V1. UL94V0. MXT-10 MXL-10 MXP C 100 40 05 MXP A 100 49 10 MXP A 100 55 10 MXP A 100 40 05 MXP A 100 55 05 230v 3 phase relay MXP A 100 44 05 VDE0609-1 8A240VAC MCU10 PDF

    DPA53

    Abstract: 380 volt 50 hz
    Contextual Info: Monitoring Relays 3-Phase Sequence and Phase Loss Type DPA53 • 3-phase monitoring relay for phase sequence and phase loss • Detects when all phases are present and have the correct sequence • Knob-adjustable undevoltage detection • Measures own power supply


    Original
    DPA53 DPA53 380 volt 50 hz PDF

    TPW400VN4X

    Abstract: 230v 3 phase relay TPW115VN4X TPW230VN4X potential transformer 230v ac 270K-470K
    Contextual Info: TPW.N4X Monitoring relays – TREND series Industrial design Width 45mm Voltage monitoring in 3-phase mains 1 change over contact Technical data 1. Functions Voltage monitoring in 3-phase mains inside the window between Umin and Umax with adjustable thresholds and adjustable


    Original
    PDF

    230v 3 phase relay

    Abstract: phase failure TPF400VS4X asymmetry TPF400 1000VA TPF115VS4X TPF230VS4X
    Contextual Info: TPF.S4X Monitoring relays – TREND series Industrial design Width 45mm Voltage monitoring in 3-phase mains 1 change over contact Technical data 1. Functions Monitoring of phase sequence, phase failure and asymmetry with fixed asymmetry, connection of the neutral wire not


    Original
    PDF

    Monitors

    Abstract: DPA01DM48 PPA01CM44 DPA01CM44 DPA01CM60 3 phase monitoring relays DPA01CM69 PPA01DM48 RELAY
    Contextual Info: Monitoring Relays 3-Phase Sequence and Phase Loss Types DPA01, PPA01 • 3-phase monitoring relays for phase sequence and phase loss • Detect when all 3 phases are present and have the correct sequence • Measure on own power supply • Power supply range: 208 to 690 VAC +10 -15%


    Original
    DPA01, PPA01 DPA01) PPA01) DPA01 Monitors DPA01DM48 PPA01CM44 DPA01CM44 DPA01CM60 3 phase monitoring relays DPA01CM69 PPA01DM48 RELAY PDF

    DPB02CM48

    Abstract: PPB02CM48 voltage380 DPB02CM23 PPB02CM23
    Contextual Info: Monitoring Relays True RMS 3-Phase, Phase Sequence/Loss - Asymmetry Types DPB02, PPB02 DPB02 PPB02 • TRMS 3-phase phase sequence, phase loss and asymmetry monitoring relays • Detect when all 3 phases are present and have the correct sequence • Detect if asymmetry level is below the set value


    Original
    DPB02, PPB02 DPB02 DPB02) PPB02) DPB02 DPB02CM48 PPB02CM48 voltage380 DPB02CM23 PPB02CM23 PDF

    DPA51CM44

    Abstract: DPA51 3 PHASE MONITORING RELAY DPA51 DPA71DM48 DPA71DM23 12 Volt DPDT Relay small 12 Volt DPDT Relay
    Contextual Info: Monitoring Relays 3-Phase Sequence and Phase Loss Types DPA51, DPA71 • 3-phase monitoring relay for phase sequence and phase loss • Detects when all phases are present and have the correct sequence • Measures own power supply • Power supply range: 208 to 480 VAC ±15%


    Original
    DPA51, DPA71 DPA51) DPA71) DPA51 DPA51CM44 DPA51 3 PHASE MONITORING RELAY DPA51 DPA71DM48 DPA71DM23 12 Volt DPDT Relay small 12 Volt DPDT Relay PDF

    OPH3W

    Abstract: 1000VA 230v 3 phase relay
    Contextual Info: OPH3W Monitoring relays – OCTO series Installation design Width 35mm Voltage monitoring in 3-phase mains 2 change over contacts Technical data 1. Functions Electrical life: Voltage monitoring in 3-phase mains with adjustable threshold, adjustable tripping delay and asymmetry, connection of the neutral wire optional


    Original
    PDF