K3YM400VSY20
Abstract: 1000VA
Contextual Info: K3YM400VSY20 Monitoring relays - KAPPA series Voltage monitoring in 3-phase- and 1-phase mains Multifunction Monitoring of phase failure and asymmetry Monitoring of phase sequence selectable Connection of neutral wire optional 2 change over contacts Plug-in housing
|
Original
|
K3YM400VSY20
400/230V
K3YM400VSY20
1000VA
|
PDF
|
11-POL
Abstract: 1000VA 230v 3 phase relay
Contextual Info: K3PF400VSY02 Monitoring relays - KAPPA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Optional connection of neutral wire Supply voltage = measuring voltage 2 change over contacts Plug-in housing
|
Original
|
K3PF400VSY02
100ms
400/230V
11-POL
1000VA
230v 3 phase relay
|
PDF
|
E1PF400VSY01
Abstract: phase failure phase sequence 1000VA three phase sequence
Contextual Info: E1PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 1 change over contact Width 17.5mm Installation design
|
Original
|
100ms
E1PF400VSY01
400/230V
340300A
E1PF400VSY01
phase failure
phase sequence
1000VA
three phase sequence
|
PDF
|
1000VA
Abstract: phase failure E3PF400VSY02 15 6KV
Contextual Info: E3PF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 2 change over contacts Width 35 mm Installation design
|
Original
|
100ms
E3PF400VSY02
400/230V
1000VA
phase failure
E3PF400VSY02
15 6KV
|
PDF
|
G2PM400VSY10
Abstract: G2PM115VSY10 G2PM230VSY10 1000VA SY10 phase failure relay 230v 3 phase relay
Contextual Info: G2PM.SY10 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Supply voltage selectable via power modules
|
Original
|
G2PM400VSY10
G2PM115VSY10
G2PM230VSY10
1000VA
SY10
phase failure relay
230v 3 phase relay
|
PDF
|
G4PM690VSYL20
Abstract: G4PM500VSYL20 1000VA
Contextual Info: G4PM.SYL20 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains for 500V resp. 690V Multifunction, fault latch Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire
|
Original
|
SYL20
G4PM690VSYL20
G4PM500VSYL20
103mm
1000VA
|
PDF
|
1000VA
Abstract: relay 230v
Contextual Info: G2PW.10 Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Windowfunction Supply voltage selectable via power modules 1 change-over contact Width 22.5mm Industrial design Technical data 1. Functions Voltage monitoring in 3-phase mains monitoring the window between
|
Original
|
G2PW400V10
1000VA
relay 230v
|
PDF
|
OF RELAY -5V, 230V INPUT
Abstract: E3YF400V02 1000VA
Contextual Info: E3YF Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 2 change over contacts Width 35 mm Installation design Technical data 1. Functions Switching frequency: Undervoltage monitoring in 3-phase mains each phase against the neutral wire with fixed adjustable threshold and fixed adjustable hysteresis.
|
Original
|
200ms
E3YF400V02
E3YF400VT02
400/230V
OF RELAY -5V, 230V INPUT
1000VA
|
PDF
|
VDE0108
Abstract: E1YU400V01 1000VA E1YF400V01
Contextual Info: E1YF, E1YU Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions Undervoltage monitoring in 3-phase mains each phase against the neutral wire with fixed or variable threshold voltage US and fixed hysteresis.
|
Original
|
200ms
E1YF400V01
E1YU400V01,
E1YF400VT01
-400/230V
VDE0108
340402A
E1YU400V01
-400/230V
VDE0108
E1YU400V01
1000VA
|
PDF
|
PPB01CM48
Abstract: DPB01CM48 PB01CM48 DPB01CM48N PPB01 PPB01CM48N PB01CM23 PB01CM48W4 DPB01
Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01 DPB01 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays • Detect when all 3 phases are present and have the correct phase sequence except for N versions
|
Original
|
DPB01,
PPB01
DPB01
DPB01)
PPB01CM48
DPB01CM48
PB01CM48
DPB01CM48N
PPB01
PPB01CM48N
PB01CM23
PB01CM48W4
DPB01
|
PDF
|
DPC02
Abstract: star delta wiring diagram power supply output 240 VAC
Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Type DPC02 • TRMS 3-phase over and under voltage, over and under frequency, phase sequence and phase loss monitoring relay • Detect when all 3 phases are present and have the correct sequence
|
Original
|
DPC02
DPC02
star delta wiring diagram
power supply output 240 VAC
|
PDF
|
DPC01DM69
Abstract: DPC01 star delta wiring diagram 400HZ 400hz relay
Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 DPC01 PPC01 • TRMS 3-phase over and under voltage, phase sequence, phase loss and asymmetry monitoring relay • Detect when all 3 phases are present and have the correct sequence
|
Original
|
DPC01,
PPC01
DPC01
DPC01)
PPC01)
DPC01DM69
DPC01
star delta wiring diagram
400HZ
400hz relay
|
PDF
|
PPB01CM48
Abstract: DPB01CM23 PPB01 DPB01CM48 star delta wiring diagram DPB01 phase failure relay 3 phase monitoring relays loss of neutral monitor marking L2 diode
Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01 DPB01 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays • Detect when all 3 phases are present and have the correct phase sequence except for DPB01.N and
|
Original
|
DPB01,
PPB01
DPB01
DPB01.
PPB01.
DPB01)
PPB01)
PPB01CM48
DPB01CM23
PPB01
DPB01CM48
star delta wiring diagram
DPB01
phase failure relay
3 phase monitoring relays
loss of neutral monitor
marking L2 diode
|
PDF
|
DPB71
Abstract: DPB71CM48 level alarm DPB71CM23
Contextual Info: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Type DPB71 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relay • Detects when all 3 phases are present and have the correct phase sequence • Detects if all the 3-phase-phase or phase-neutral voltages are within the set limits
|
Original
|
DPB71
DPB71
DPB71CM48
level alarm
DPB71CM23
|
PDF
|
|
|
1000VA
Abstract: E3YU400V02
Contextual Info: E3YU400V02 Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = meased voltage 2 change over contacts Width 35 mm Installation design Technical data 1. Functions 7. Measuring circuit Undervoltage monitoring in 3-phase mains each phase against the neutral wire with adjustable threshold US and fixed adjustable hysteresis.
|
Original
|
E3YU400V02
200ms
400/230V
60-240V
1000VA
E3YU400V02
|
PDF
|
G2PM115VSY20
Abstract: g2pm230vsy20 G2PM400VSY20 1000VA 24-240V SY20 n345 phase failure 3 phase monitoring relays
Contextual Info: G2PM.SY20 24-240V Monitoring relays - GAMMA series Voltage monitoring in 3-phase mains Multifunction Monitoring of phase sequence and phase failure Monitoring of asymmetry selectable Connection of neutral wire optional Detection of loss of neutral wire Zoom voltage 24 to 240V AC/DC
|
Original
|
4-240V
G2PM400VSY20
4-240V,
24VAC/DC
G2PM115VSY20
g2pm230vsy20
1000VA
24-240V
SY20
n345
phase failure
3 phase monitoring relays
|
PDF
|
MXP C 100 40 05
Abstract: MXP A 100 49 10 MXP A 100 55 10 MXP A 100 40 05 MXP A 100 55 05 230v 3 phase relay MXP A 100 44 05 VDE0609-1 8A240VAC MCU10
Contextual Info: Control & Monitoring Relays 3-Phase Monitoring Relay MXP-10 DESCRIPTION OPERATION A relay for monitoring a 3-phase AC power supply with or without Neutral. The relay monitors that all phases are available and in the correct phase sequence U,V,W , that none of the phases are
|
Original
|
MXP-10
115/3x230/3x400VAC)
MXV-30
75kVAC
EN60950)
UL94V1.
UL94V0.
MXT-10
MXL-10
MXP C 100 40 05
MXP A 100 49 10
MXP A 100 55 10
MXP A 100 40 05
MXP A 100 55 05
230v 3 phase relay
MXP A 100 44 05
VDE0609-1
8A240VAC
MCU10
|
PDF
|
DPA53
Abstract: 380 volt 50 hz
Contextual Info: Monitoring Relays 3-Phase Sequence and Phase Loss Type DPA53 • 3-phase monitoring relay for phase sequence and phase loss • Detects when all phases are present and have the correct sequence • Knob-adjustable undevoltage detection • Measures own power supply
|
Original
|
DPA53
DPA53
380 volt 50 hz
|
PDF
|
TPW400VN4X
Abstract: 230v 3 phase relay TPW115VN4X TPW230VN4X potential transformer 230v ac 270K-470K
Contextual Info: TPW.N4X Monitoring relays – TREND series Industrial design Width 45mm Voltage monitoring in 3-phase mains 1 change over contact Technical data 1. Functions Voltage monitoring in 3-phase mains inside the window between Umin and Umax with adjustable thresholds and adjustable
|
Original
|
|
PDF
|
230v 3 phase relay
Abstract: phase failure TPF400VS4X asymmetry TPF400 1000VA TPF115VS4X TPF230VS4X
Contextual Info: TPF.S4X Monitoring relays – TREND series Industrial design Width 45mm Voltage monitoring in 3-phase mains 1 change over contact Technical data 1. Functions Monitoring of phase sequence, phase failure and asymmetry with fixed asymmetry, connection of the neutral wire not
|
Original
|
|
PDF
|
Monitors
Abstract: DPA01DM48 PPA01CM44 DPA01CM44 DPA01CM60 3 phase monitoring relays DPA01CM69 PPA01DM48 RELAY
Contextual Info: Monitoring Relays 3-Phase Sequence and Phase Loss Types DPA01, PPA01 • 3-phase monitoring relays for phase sequence and phase loss • Detect when all 3 phases are present and have the correct sequence • Measure on own power supply • Power supply range: 208 to 690 VAC +10 -15%
|
Original
|
DPA01,
PPA01
DPA01)
PPA01)
DPA01
Monitors
DPA01DM48
PPA01CM44
DPA01CM44
DPA01CM60
3 phase monitoring relays
DPA01CM69
PPA01DM48
RELAY
|
PDF
|
DPB02CM48
Abstract: PPB02CM48 voltage380 DPB02CM23 PPB02CM23
Contextual Info: Monitoring Relays True RMS 3-Phase, Phase Sequence/Loss - Asymmetry Types DPB02, PPB02 DPB02 PPB02 • TRMS 3-phase phase sequence, phase loss and asymmetry monitoring relays • Detect when all 3 phases are present and have the correct sequence • Detect if asymmetry level is below the set value
|
Original
|
DPB02,
PPB02
DPB02
DPB02)
PPB02)
DPB02
DPB02CM48
PPB02CM48
voltage380
DPB02CM23
PPB02CM23
|
PDF
|
DPA51CM44
Abstract: DPA51 3 PHASE MONITORING RELAY DPA51 DPA71DM48 DPA71DM23 12 Volt DPDT Relay small 12 Volt DPDT Relay
Contextual Info: Monitoring Relays 3-Phase Sequence and Phase Loss Types DPA51, DPA71 • 3-phase monitoring relay for phase sequence and phase loss • Detects when all phases are present and have the correct sequence • Measures own power supply • Power supply range: 208 to 480 VAC ±15%
|
Original
|
DPA51,
DPA71
DPA51)
DPA71)
DPA51
DPA51CM44
DPA51 3 PHASE MONITORING RELAY
DPA51
DPA71DM48
DPA71DM23
12 Volt DPDT Relay small
12 Volt DPDT Relay
|
PDF
|
OPH3W
Abstract: 1000VA 230v 3 phase relay
Contextual Info: OPH3W Monitoring relays – OCTO series Installation design Width 35mm Voltage monitoring in 3-phase mains 2 change over contacts Technical data 1. Functions Electrical life: Voltage monitoring in 3-phase mains with adjustable threshold, adjustable tripping delay and asymmetry, connection of the neutral wire optional
|
Original
|
|
PDF
|