Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    2 WIRE PT100 SENSOR Search Results

    2 WIRE PT100 SENSOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-5XRJ11PPXS-014
    Amphenol Cables on Demand Amphenol MP-5XRJ11PPXS-014 Flat Silver Satin Modular Crossed wiring Cable, RJ11 / RJ11 14ft PDF
    MP-64RJ4528GG-003
    Amphenol Cables on Demand Amphenol MP-64RJ4528GG-003 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - Green 3ft PDF
    MP-64RJ4528GK-014
    Amphenol Cables on Demand Amphenol MP-64RJ4528GK-014 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - Black 14ft PDF
    MP-64RJ4528GW-007
    Amphenol Cables on Demand Amphenol MP-64RJ4528GW-007 Slim Category-6 (Thin CAT6) UTP 28-AWG Network Patch Cable (550-MHz) with Snagless RJ45 Connectors - White 7ft PDF
    MP-6A28GNSBLK-007
    Amphenol Cables on Demand Amphenol MP-6A28GNSBLK-007 Slim Category-6a (Thin CAT6a) UTP 28-AWG Network Patch Cable (650-MHz) with Snagless RJ45 Connectors - Black 7ft PDF

    Documents mentioning 2 WIRE PT100 SENSOR

    Document Partial File Text Tags Type PDF
    pt100 sensors
    Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I
    Original PDF
    pt100 sensor
    Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I
    Original PDF
    pt100 sensors
    G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure detection Reinforced insulation of the input circuit Measured value transmitting via standard bus Modular monitoring system Width 22.5mm Industrial design Technical data
    Original PDF
    2 © Siemens AG 2015 Temperature Measurement 2/2
    2 © Siemens AG 2015 Temperature Measurement 2/2 2/7 2/11 2/18 2/25 2/31 2/38 2/45 Product overview Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system universal, HART
    Original PDF
    FlexTemp 2301 Temperature Transmitter 4…20 mA
    FlexTemp 2301 Temperature Transmitter 4…20 mA transmitter for Pt100 sensors 2-, 3- or 4-wire sensors Accuracy better than 0.25°C Sensor offset correction Automatic/configurable cable resistance compensation (2-wire) Sensor error detection 2-way configuration (Windows)
    Original PDF
    m1mpt100
    M1MPT100 24-240V Signal converters - M1 series Temperature transmitter for temperatures from -100 up to +700°C Multifunction Signal type and measuring range preselection via DIP-switch Approved for temperature sensors Pt100 and Pt1000 2-wire, 3-wire and 4-wire sensors
    Original PDF
    th300
    2 © Siemens AG 2013 Temperature Measurement 2/2 Product overview 2/124 2/7 2/11 2/18 2/25 2/31 2/38 2/45 2/57 2/62 2/70 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system
    Original PDF
    mtw 12
    Intelligent interface modules Temperature modules for PT 100 Sensors MTW 12,4 MTW 12,4 2- 3-wire 4-wire Circuit diagram Input E1 PT 100 Output ϑ U ϑ E2 Technical data Supply voltage range Supply current Cable resistance (without PT100) Output signals Tolerance
    Original PDF
    g2tmpt100l20
    G2TMPT100L20 Monitoring relays - GAMMA series Temperature monitoring via Pt100 sensors (2- and 3-wire connection) Multifunction Monitoring of short circuit or line break of sensor line Fault latch Supply voltage selectable via power modules 2 change-over contacts
    Original PDF
    ricos ricos Distributed I/O Modules PT/TC Modules
    ricos ricos Distributed I/O Modules PT/TC Modules 4 sensor inputs per module, self-setting to PT100/PT1000 sensors for 2-wire, 3-wire and 4-wire connection for thermocouples type J/K Dimensions (mm): W x H x D 69 x 92 x 51 Description Analog module 4 inputs PT 100/1000
    Original PDF
    g2tmpt100l20
    G2TMPT100L20 24-240V Monitoring relays - GAMMA series Temperature monitoring via Pt100 sensors (2- and 3-wire connection) Multifunction Monitoring of short circuit or line break of sensor line Fault latch Zoom voltage 24 to 240V AC/DC 2 change-over contacts
    Original PDF
    pt100 thermistor
    DTM 910 LCD Type Pt100 Temperature Indicator The DTM 910 will give an accurate direct temperature reading in either °C or °F from a 2, 3 or 4 wire Pt100 thermistor*. Simple single step calibration is achieved using a 20-turn potentiometer which allows sensitive adjustment. The meter is housed in a robust carrier which can be bolted in place or panel
    Original PDF
    Peltier-Controller • Output for Peltiermodules •
    Peltier-Controller • Output for Peltiermodules • pt100 / pt1000 or customized sensors, user programmable • 2-or 3 wire connection • PID-Controller, programmable • Supply voltage, optional with switch on or switch off function • Signal output, optional with alarm- or temperature
    Original PDF
    pt100
    CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features „„ Pt100 sensor element, 2- or 4-wire „„ Built in graphical display, ­CombiViewTM DFON optional „„ Head mounted 4…20 mA ­transmitter, FlexTop type 22xx „„ HART®, PA „„ ATEX
    Original PDF
    transmicor
    TRANSMICOR T231 SERIES RELATIVE HUMIDITY TRANSMITTER FOR WALL MOUNTING Main characteristics • Measuring range: 0… 100 %rh, -30…+70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Supply voltage: 9…33VDC
    Original PDF
    transmicor
    TRANSMICOR T232 series high temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0… 100 %rh, -30… +140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9…33VDC
    Original PDF
    transmicor
    TRANSMICOR T233 series low temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE PROBE Main characteristics • Measuring range: 0… 100 %rh, -30… +85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9… 33VDC
    Original PDF
    mcr-sl-pt100-sp
    Extract from the online catalog   MCR-SL-PT100-SP Order No.: 2814948 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2814948   MCR temperature relay, for Pt 100 in 2-wire system; input: -100 °C… +700 °C   Product notes WEEE/RoHS-compliant since:
    Original PDF
    transmicor
    TRANSMICOR T233 series high temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE PROBE Main characteristics • Measure range: 0… 100 %rh, -30…+140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9/33VDC
    Original PDF
    mcr-sl-pt100-sp
    Extract from the online catalog   MCR-SL-PT100-SP Order No.: 2814948 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2814948   MCR temperature relay, for Pt 100 in 2-wire system; input: -100 °C… +700 °C   Product notes WEEE/RoHS-compliant since:
    Original PDF
    q414
    ACTIONI/Q® Q414 & Q415 MODEL Protecting the Integrity of Industrial Process Signals RTD Input, Three-Wire Transmitter Provides Two DC Outputs in Proportion toTwo Pt100Ω RTD Temperature Inputs Benefits n Multi-Channel Design Provides Two (2) Threewire Transmitters in 1
    Original PDF
    transmicor
    TRANSMICOR T232 Series low temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0…100 %rh, -30… +85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4… 20mA (2 wire), Pt100 Ω 1/3 DIN • Power supply: 9… 33VDC
    Original PDF