1800VAC Search Results
1800VAC Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
FASTON
Abstract: FASTON connector faston 250 connector AMP Faston electromedical
|
OCR Scan |
250vac1800vac2500vacul94v2+5 | |
|
Contextual Info: PREM O FF Electrical schematics LINE RFI Power Line Filters General Purpose PE g H * Ô Cy^ Cx: General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: IVN->PE: 1800Vac 2s. L->N: 1700 Vdc 2s. General Purpose |
OCR Scan |
250vac1800vacff-10zff-20w+1 | |
|
Contextual Info: PREMO FTCV RFI Power Line Filters I EC Connector Filter Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. H ip ot test voltage: L/N->PE: 1800Vac 2s. 2500Vac for M version L->N: 1700 Vdc 2s. Application class: HPFAcc. T O D IN 40040 |
OCR Scan |
250vac1800vac2500vac | |
|
Contextual Info: PREM O FT A RFI Power Line Filters IEC Filter Small Size Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hi pot test voltage: L/N->PE: 1800Vac 2s. L->N: 1700 Vdc 2s. Application class: H PF Acc. T O DIN 40040 |
OCR Scan |
250vac1800vac100cal | |
SMM 201Contextual Info: PREM O PE RFI Power Line Filters General Purpose Electrical schem atics PE L1 General Specifications General Purpose Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N->PE: 1800Vac 2s. L->N: 1700 Vdc 2s. Application class: H PF Acc. T O DIN 40040 |
OCR Scan |
250vac1800vacpe-05v-e28mm700+1 | |
UL94V2
Abstract: FASTON connector 3z fuse electromedical AMP Faston
|
OCR Scan |
250vac1800vacul94v2faston connector+3 | |
Notebook lcd inverter schematic
Abstract: UI85 ferrite core transformer ratio 5 ferrite pot core Notebook lcd inverter lcd inverter SCHEMATIC TR02072402
|
Original |
10khz180uh750vac1800vac+8 | |
|
Contextual Info: PREMO FTN I EC Connector Filter Electrical schematics L1 w L{ u o “t Cx: _ F2 FTN-*M lu pi J" L1 L'/ Cx' = p e !v,= ^ _ 1 © i •/"a o i F2 General Specifications M axim um o p e ra tin g voltage: 250Vac. O p e ra tin g frequency: DC - 60Hz. Hi p o t te st voltage: L/N->PE: 1800Vac 2s. |
OCR Scan |
250vac1800vac | |
NF216
Abstract: 1dz 2 AMP Faston AWG18
|
OCR Scan |
250vac1800vacawg18ff-10z+5 | |
12V,1A Transformer specification
Abstract: J201
|
Original |
cint1275en/iec/ul60950standby10012v,1a transformer specification+1 | |
|
Contextual Info: PART MUST INSERT FULLY TO SURFACE A IN RECOMMENDED GRID .021 SQ . 10 .1 0 0 / . 1 30 * [.53] [2.54/3.30] (6H)(6M) rV 7DC 8□[ 9□[ IUo|_ I I * DIMENSION MAY BE EXCEEDED WITH SOLDER ONLY -A CCCI .500 MAX. [12.70] ]o4 >3 >2 ju I A kJAV .550 MAX. [1 3 .9 7 ] |
OCR Scan |
bt8921e205930 | |
EN60939-2Contextual Info: PREMO FE General Purpose Chassis mounting single stage filter. General purpose. Good attenuation in a wide frecuency range. Low leakage current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: D C - 60Hz. Hipot test voltage: |
OCR Scan |
250vac1800vacawg18fe-20z+5 | |
|
Contextual Info: PREMO PE RFI Power Line Filters General Purpose Electrical schematics PE CO T L1 L ENSOON-2 r ° - -o Q < O Cy: LU C x_ cy: 1^ i _ = PE-*-E2 -o L’ C y^: lu 0— T -• f ©fi J-CyI PE N N' L1 L o- - L’ T D i s C xT T T o- -o N ’ General Specifications |
OCR Scan |
250vac1800vacpe-05v-e2 | |
|
Contextual Info: PREMO FR-FRR RFI Power Line Filters General Purpose General Purpose Chassis m ounting filter fo r general purpose applications. Single stage filter. Low leakage current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. |
OCR Scan |
250vac1800vacawg18 | |
|
|
|||
faston
Abstract: FB-10Z FB-20W 1800VAC AMP Faston AWG18 FB2Z FB 2Z
|
OCR Scan |
250vac1800vaceh6d933awc18+8 | |
faston
Abstract: 10 amp smps AMP Faston AWG18 FC-6Z smps NF217
|
OCR Scan |
250vac1800vacawg18fc-10xrical+7 | |
FASTON
Abstract: AMP Faston FASTON screw AWG18
|
OCR Scan |
250vac1800vacawg18feh-10x+4 | |
faston
Abstract: AMP Faston AWG18 NF216 10 amp smps nf221
|
OCR Scan |
250vac1800vacawg18fl-10z+5 | |
|
Contextual Info: TO-220 Power Resistor-TR20 •Construction 1 Alumina Substrate 2 Resistor Layer ■Features 3 Lead 4 Molding ■Dimensions Type Weight g (1000pcs) TR20 1290 0.63 0.65" (16.00 16.52mm) -20 Watts at 25°C case temperature heat sink mounted -TO-220 style power package |
Original |
o-2201000pcstr100 | |
|
Contextual Info: TO-220 Power Resistor-TR30 •Construction 1 Alumina Substrate 2 Resistor Layer ■Features 3 Lead 4 Molding ■Dimensions Unit: mm Type Weight g (1000pcs) TR30 1155 -Gate Resistors in Power Supplies -Snubbers -Load and Dumping Resistors in CRT Monitors |
Original |
o-2201000pcs | |
|
Contextual Info: PCB Mount Filters F.AM.AV series High performance This range provides a high level of performance within compact metal enclosures for printed circuit board configurations. Specifically designed to protect against symmetric, assymetric, periodic and pulse shaped RFI. |
Original |
50/60hz2x25002x68002x1000 | |
2x062
Abstract: Faston 6.3x0,8 ZD 22 faidb2150zc 2x4700 F.AM.DI.3600.ZE 2X40 3600ZL 047 D 45 3600Z
|
Original |
2x062faston 6.3x0,8zd 22faidb2150zc+6 | |
military relay
Abstract: Airpax relay cross reference Airpax Airpax 203 Airpax motor circuit breaker airpax 203 family Airpax breakers LR26229
|
Original |
dc-50/60hz50/60hzmilitary relayairpax relay cross reference+6 | |
venturi
Abstract: MIL-R-39009
|
Original |
rmg50o-22050ppm/100ppm/+3 | |