12V UPS BATTE Search Results
12V UPS BATTE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TA75W01FU | Toshiba Electronic Devices & Storage Corporation | Operational Amplifier, Bipolar (358) type Dual Op-Amp, 3V to 12V, SOT-505 | Datasheet | ||
| TA75S01F | Toshiba Electronic Devices & Storage Corporation | Operational Amplifier, Bipolar (358) type, 3V to 12V, SOT-25 | Datasheet | ||
| BATTERYBOOK | Texas Instruments | BATTERYBOOK |
|
||
| 10131125-Z0300YYLF | Amphenol Communications Solutions | 10131125-Z0300YYLF-POWER USB(12V) SINGLE | |||
| 10127528-Z0300YYLF | Amphenol Communications Solutions | 10127528-Z0300YYLF-PWRUSB(12V) DOUBLE ENDED |
Documents mentioning 12V UPS BATTE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| UB10.245 DC-UPS, DUAL OUTPUT 24V DC-UPS With an | UB10.245 DC-UPS, DUAL OUTPUT 24V DC-UPS With an Additional 12V Output for Various Applications Only One 12V Battery Required Stable Output Voltage in Buffer Mode Superior Battery Management for Longest Battery Life Comprehensive Diagnostic and Monitoring Functions |
Original | ||||
| UB10.241 24V, 10A, DC-UPS U–Series DC-UPS CONTROL | UB10.241 24V, 10A, DC-UPS U–Series DC-UPS CONTROL UNIT ■ Requires Only One 12V Battery for a 24V Output Stable Output Voltage in Buffer Mode Superior Battery Management for Longest Battery Life Comprehensive Diagnostic and Monitoring Functions |
Original | ||||
| ups12-140 | FEATURES UPS12-140 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 33 AH @ 20 HR RATE, 12V 137 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-310 | FEATURES UPS12-310 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 88 AH @ 20 HR RATE, 12V 329 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-475 | FEATURES UPS12-475 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 134 AH @ 20 HR RATE, 12V 475 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-270 | FEATURES UPS12-270 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 75 AH @ 20 HR RATE, 12V 282 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-200 | FEATURES UPS12-200 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 54 AH @ 20 HR RATE, 12V 203 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-370 | FEATURES UPS12-370 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 100 AH @ 20 HR RATE, 12V 390 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-170 | UPS12-170 FEATURES VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 50 AH @ 20 HR RATE, 12V 170 WATTS/CELL @ 15 MIN RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-100 | FEATURES UPS12-100 VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 26 AH @ 20 HR RATE, 12V 91 WATTS/CELL @ 15 MIN. RATE · 10 Year design life @ 25°C (77°F) · Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to |
Original | ||||
| ups12-530 | UR N RE E CL RE T CY 41-7113UPS LEAD UPS12-530FR VALVE REGULATED LEAD ACID BATTERY FOR UPS STANDBY POWER APPLICATIONS 12V 145 AH @ 20 HR RATE, 12V 530 WATTS/CELL @ 15 MIN. RATE FEATURES • 10 Year design life @ 25°C (77°F) • Absorbent Glass Mat (AGM) technology |
Original | ||||
| mr12-540 | UR N RE CL RE T CY E 41-9012 LEAD MR12-540 VALVE REGULATED LEAD ACID BATTERY PREMIUM REPLACEMENT FOR MAXRATE 12-490 AND UPS12-530FR FOR UPS STANDBY POWER APPLICATIONS 12V 147 AH @ 20 HR RATE, 12V 537 WATTS/CELL @ 15 MIN. RATE FEATURES • 10 year design life @ 25˚C (77˚F) |
Original | ||||
| lnk520 | Design Example Report Title 4.8W Charger using LNK520P Specification Input: 85 – 265 VAC 50/60Hz Output: 12V / 400mA Application UPS Battery Charger Author Power Integrations Applications Department Document Number DER-56 Date April 20, 2005 Revision 1.0 |
Original | ||||
| UB10.241 DC-UPS CONTROL UNIT Requires Only One | UB10.241 DC-UPS CONTROL UNIT Requires Only One 12V Battery for a 24V Output Stable Output Voltage in Buffer Mode Superior Battery Management for Longest Battery Life Comprehensive Diagnostic and Monitoring Functions Replace Battery Signal Included Electronically Overload and Short Circuit Protected |
Original | ||||
|
|
||||||
| pic12c508-based | SIMPLECIRCUIT™ PIC12C508-Based Battery Monitor Author: 12V batteries are considered fully charged at 13.8 volts and fully exhausted at 10.8 volts. This 3 volt range is quite linear and can be used to predict the amount of time remaining for UPS backup. Dana Peterson |
Original | ||||
| ct24-12 | LEADER CT24-12LX [12V-24Ah] VA LV E R E G U L AT E D L E A D A C I D B AT T E R I E S - [ A G M ] DESCRIPTION The CT Leader range is designed for general purpose applications, such as UPS, alarm systems, telecom and technical utilities. With 10 years design life, the batteries comply to the international standards IEC896-2 |
Original | ||||
| ct17-12 | LEADER CT17-12LX [12V-17Ah] VA LV E R E G U L AT E D L E A D A C I D B AT T E R I E S - [ A G M ] DESCRIPTION The CT Leader range is designed for general purpose applications, such as UPS, alarm systems, telecom and technical utilities. With 10 years design life, the batteries comply to the international standards IEC896-2 |
Original | ||||
| ct8-12h | LEADER CT8-12H [12V-8Ah] VA LV E R E G U L AT E D L E A D A C I D B AT T E R I E S - [ A G M ] DESCRIPTION The CT Leader range is designed for general purpose applications, such as UPS, alarmsystem, telecom and technical utilities. The batteries comply to Eurobat guide Standard Commercial and have a design life of |
Original | ||||
| liebert | Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: RBC53 UPS Replacement Battery Cartridge Kit for select Tripp Lite, Best, Powerware, Liebert and other UPS Highlights Up to 30% longer runtime than basic replacements |
Original | ||||
| rbc54 | Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: RBC54 UPS Replacement Battery Cartridge Kit for select Tripp Lite, Best, Powerware, Liebert and other UPS Highlights Up to 30% longer runtime than basic replacements |