| 265gs | Data Sheet FieldIT SS/265GS/AS_4 2600T Series Pressure Transmitters Model 265GS Gauge Model 265AS Absolute standard overload Base accuracy : ±0.04% ■ Span limits – 0.2 to 60000kPa; 0.8inH2O to 8700psi – 0.3 to 3000kPa abs; 2.25mmHg to 435psia ■ Reliable sensing system coupled with very latest |
Original | ||||
| 262hs | FieldIT Data Sheet SS/262HS/NS_1 2600T Series Pressure Transmitters Model 262HS Gauge Model 262NS Absolute high overload maximum working pressure up to 65MPa, 9400psi ■ Base accuracy : ±0.15% ■ Span limits – 1.6 to 42000kPa; 6.4inH2O to 6090psi – 2.67 to 42000kPa abs; 20mmHg to 6090psia |
Original | ||||
| 2600t | Data Sheet 2600T Series Pressure Transmitters SS/268XR_8 Model 268DR Differential Models 268PR and 268HR Gauge Models 268VR and 268NR Absolute with remote seal(s) ■ TÜV SIL2 certified to IEC 61508 – the smart solution in Safety loop application ■ Best in Class Safety protection for your plants |
Original | ||||
| 264bs | FieldIT Data Sheet SS/264BS_8 2600T Series Pressure Transmitters Model 264BS Differential for high static maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.075% ■ Span limits – 0.2 to 2000kPa; 0.8inH2O to 290psi ■ Reliable sensing system coupled with very latest |
Original | ||||
| 2600t | Data Sheet 2600T Series Pressure Transmitters SS/264HS/NS_8 Model 264HS Gauge Model 264NS Absolute high overload overpressure up to 90MPa, 13050psi ■ Base accuracy : ±0.075% ■ Span limits – 0.27 to 60000kPa; 1.08inH2O to 8700psi – 1.1 to 16000kPa abs; 8mmHg to 2320psia |
Original | ||||
| 2600t | Data Sheet 2600T Series Pressure Transmitters SS/364DD_4 Model 364DD Differential/Gauge with flanged direct mount seal ■ Best in class total performance – long term stability of 0.15% for 10 years – base accuracy of 0.06% ■ The space saver – the solution for multiple installations in reduced |
Original | ||||
| 2600t | FieldIT Data Sheet SS/262XR_1 2600T Series Pressure Transmitters Model 262DR Differential Models 262PR and 262HR Gauge Models 262VR and 262NR Absolute with remote seal(s) ■ Base accuracy : ±0.15% ■ Span limits – 0.2 to 16000kPa; 0.8inH2O to 2320psi |
Original | ||||
| 2600t | FieldIT Data Sheet SS/264XS_2 2600T Series Pressure Transmitters Model 264DS Differential Model 264PS Gauge Model 264VS Absolute maximum working pressure up to 21MPa, 3045psi ■ Base accuracy : ±0.075% ■ Span limits – 0.14 to 16000kPa; 0.56inH2O to 2320psi |
Original | ||||
| 2600t | FieldIT Data Sheet SS/364XS_5 2600T Series Pressure Transmitters Model 364DS Differential Model 364PS Gauge maximum working pressure up to 20MPa, 2900psi ■ Best in class total performance – long term stability of 0.15% for 10 years – base accuracy of 0.06% |
Original | ||||
| 2600t | 2600T Series Pressure Transmitters Data Sheet SS/268XS_8 Model 268DS Differential Model 268PS Gauge Model 268VS Absolute maximum working pressure up to 21MPa, 3045psi ■ TÜV SIL2 certified to IEC 61508 – the smart solution in Safety loop application ■ Best in Class Safety protection for your plants |
Original | ||||
| 2600t | 2600T Series Pressure Transmitters Data Sheet SS/264XS_7 Model 264DS Differential Model 264PS Gauge Model 264VS Absolute maximum working pressure up to 21MPa, 3045psi ■ Base accuracy : ±0.075% ■ Span limits – 0.05 to 16000kPa; 0.2inH2O to 2320psi – 0.27 to 16000kPa abs; 2mmHg to 2320psia |
Original | ||||
| 2600t | Data Sheet 2600T Series Pressure Transmitters SS/264XD_5 Model 264DD Differential/Gauge Model 264HD Gauge Model 264ND Absolute with flanged direct mount seal ■ Base accuracy : ±0.075% ■ Span limits – 0.54 to 16000kPa; 2.14inH2O to 2320psi – 1.1 to 16000kPa abs; 8mmHg to 2320psia |
Original | ||||
| 2600t | Operating instructions 2600T Series Pressure Transmitters Model 267C Model 269C Contents 1 1 Safety Page Safety… 2 General safety precautions and health protection… 2 |
Original | ||||
| 262gs | FieldIT Data Sheet SS/262GS/AS_1 2600T Series Pressure Transmitters Model 262GS Gauge Model 262AS Absolute standard overload maximum working pressure up to 90MPa, 13050psi ■ Base accuracy : ±0.15% ■ Span limits – 0.2 to 60000kPa; 0.8inH2O to 8700psi |
Original | ||||
|
|
||||||
| 2600t | FieldIT Data Sheet SS/264DH_5 2600T Series Pressure Transmitters Model 264DH Differential flange mounted maximum working pressure up to 5MPa, 725psi ■ Base accuracy : ±0.075% ■ Span limits – 0.27 to 2400kPa; 1.08inH2O to 348 psi ■ Reliable sensing system coupled with very latest |
Original | ||||
| 263ds | Data Sheet FieldIT SS/263DS_2 2600T Series Pressure Transmitters Model 263DS Differential selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.075% ■ Span limits – 0.05 to 10000kPa; 0.2inH2O to 1450psi ■ True draft range transmitter |
Original | ||||
| 2600t | Data Sheet 2600T Series Pressure Transmitters SS/264XR_8 Model 264DR Differential Models 264PR and 264HR Gauge Models 264VR and 264NR Absolute with remote seal(s) ■ Base accuracy : ±0.075% ■ Span limits – 0.2 to 60000kPa; 0.8inH2O to 8700psi – 0.54 to 16000kPa abs; 4mmHg to 2320psia |
Original | ||||
| 2600t | Data Sheet 2600T Series Pressure Transmitters SS/364GS/AS_1 Model 364GS Gauge Model 364AS Absolute standard overload ■ Best in class total performance – long term stability of 0.25% for 10 years – base accuracy of 0.06% ■ The space saver – the solution for multiple installations in reduced |
Original | ||||
| 2600t | Data Sheet FieldIT SS/265DS_3 2600T Series Pressure Transmitters Model 265DS Differential selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.04% ■ Span limits – 0.05 to 10000kPa; 0.2inH2O to 1450psi ■ True draft range and ultra performance transmitter |
Original | ||||
| 2600t | FieldIT Data Sheet SS/264HF/NF_3 2600T Series Pressure Transmitters Model 264HF Gauge (fast) Model 264NF Absolute (fast) high overload maximum working pressure up to 21MPa, 3045psi ■ Base accuracy : ±0.075% ■ Span limits – 0.65 to 160kPa; 6.4 to 642inH2O |
Original | ||||
| 269cs | Data Sheet FieldIT SS/269CS_4 2600T Series Pressure Transmitters Model 269CS Multivariable for mass flow selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.04% ■ Span limits – 0.05 to 2000kPa, 0.2inH2O to 290psi differential |
Original | ||||
| 264gs | FieldIT Data Sheet SS/264GS/AS_2 2600T Series Pressure Transmitters Model 264GS Gauge Model 264AS Absolute standard overload maximum working pressure up to 90MPa, 13050psi ■ Base accuracy : ±0.075% ■ Span limits – 0.2 to 60000kPa; 0.8inH2O to 8700psi |
Original | ||||
| 2600t | FieldIT Data Sheet SS/264BS_2 2600T Series Pressure Transmitters Model 264BS Differential for high static maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.075% ■ Span limits – 0.2 to 2000kPa; 0.8inH2O to 290psi ■ Reliable sensing system coupled with very latest |
Original | ||||
| 2600t | Data Sheet FieldIT SS/265JS_3 2600T Series Pressure Transmitters Model 265JS Differential and absolute selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.04% ■ Span limits – 0.05 to 10000kPa, 0.2inH2O to 1450psi differential |