Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    100A MCB Search Results

    100A MCB Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    62684-501100ALF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 50 Position , Side Entry, Lower Side Contact, Surface Mount, ZIF PDF
    62684-452100AHLF
    Amphenol Communications Solutions 0.50mm Flex Connector, OPU Series, 45 Position , Side Entry, Upper Side Contact, Surface Mount, ZIF, Halogen free PDF
    HM2R81PA8100AALF
    Amphenol Communications Solutions Back Plane Connectors, 2mm Hard Metric Series, Millipacs, Right Angle Receptacle,Type D 22 without Pegs,Press Fit Tail, , and ROHS Compliant PDF
    U90L1E1100A
    Amphenol Communications Solutions ExpressPort QSFP+, High Speed Input Output Connectors, SFP CAGE WITH HS AND CLIP. PDF
    U91D122100A31
    Amphenol Communications Solutions CXP, High Speed Input Output Connector, ENHANCED FOOTPRINT PDF

    Documents mentioning 100A MCB

    Document Partial File Text Tags Type PDF
    Technical data Section 9 Miniature circuit
    Technical data Section 9 Miniature circuit breakers Breaking capacities Tripping characteristics B type distribution board de-rating table Board Standard MGB4N Split load Multi service Heavy duty Busbar rating 250A 200A 160A 250A 100A Integral MCCB 0.9 0.9
    Original PDF
    Energy Shelf API0HR53-000 Description:
    Energy Shelf API0HR53-000 Description: API0HR53-000 (48V/50A/100A) energy shelf system provides straightforward energy solution for -48VDC telecommunication applications. By incorporating state-ofthe-art switching mode rectifier and advanced microprocessor technologies, the energy shelf system is
    Original PDF
    comb busbars
    Comb busbars, connectors and assembled terminals Application for Comb busbar C60H When fed by a single cable per phase the busbar is rated 100A at 40°C. If two connections (i.e. two cables) are used per phase the rating is increased to 120A. Short circuit rating compatible with the breaking capacity of the MCBs fitted.
    Original PDF
    api-7200
    -48V/100A API-7200 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac (3 3W)/156Vac(3 4W) and auto recovery when mains have
    Original PDF
    c60h
    Comb busbars, connectors and assembled terminals Application for Comb busbar C60H When fed by a single cable per phase the busbar is rated 100A at 40°C. If two connections (i.e. two cables) are used per phase the rating is increased to 120A. Short circuit rating compatible with the breaking capacity of the MCBs fitted.
    Original PDF
    api-7200
    -48V/100A API-7200 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac (3 3W)/156Vac(3 4W) and auto recovery when mains have
    Original PDF
    gl-63a
    Load-isolation Switch 1- Switch Disconnectors GL series load-isolation switch http://www.greegoo.com 1 GL-63A GL-100A GL-160A/3 GL-160A/4 GL-250A/3 GL-250A/4 GL-400A/3 GL-400A/4 GL-630A/3 GL-630A/4 GL-1000A/3 GL-1250A/3 GL-1250A/4 GL-1600A/3 GL-2500A/3 Greegoo Electric 7.2007
    Original PDF
    Altech Busbar Systems The Altech Busbar system is
    Altech Busbar Systems The Altech Busbar system is an innovative way to jumper up to 57 poles of Altech Miniature Circuit Breakers (MCB)/ Manual Motor Controllers (MMC), Supplementary Protectors (SP). Without Busbar Altech Busbar Systems The advantages of this jumper system are:
    Original PDF
    Line Protection Contents Miniature Circuit
    Line Protection Contents Miniature Circuit Breakers (MCB’s)… 3-2 Protecta Type B Pan Assemblies… 3-12 High Performance MCB’s…
    Original PDF
    Consumer Units tra Combinations Consumer Units
    Consumer Units tra Combinations Consumer Units Designed and built to the latest British and European standards to meet the needs of the building and refurbishment markets. A variety of MCB’s, RCD’s and RCBO’s offer outstanding performance with 6kA and 10kA
    Original PDF
    rccb
    Circuit protection devices MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors EA 2002/1 Welcome to the new edition of our general catalogue For easy reference purposes, Hager general catalogue is divided into three separate catalogues each representing
    Original PDF
    CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar
    CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar Support Power Supply MCB Bar Contactor / Thermal Overload Relay / Auxiliary Contact Terminal Block Din Rail Terminal Block C/W Cover Terminal Block Float Switch Foot Switch Warning Light / Tower Light Hour Run Meter / Time Switch / Weather Proof Isolating Switch
    Original PDF
    dpn rcbo
    DPN RCBO Combined MCB/RCD Application Protection against the effects of earth leakage, overload and short circuit currents. ■ 2 pole switching of phase & neutral. Phase protected against overloads and short circuits. ■ Commercial, industrial and domestic electrical
    Original PDF
    dpn rcbo
    DPN RCBO Combined MCB/RCD 1P + switched neutral Application Protection against the effects of earth leakage, overload and short circuit currents. ■ 2 pole switching of phase & neutral. Phase protected against overloads and short circuits ■ Commercial, industrial and domestic electrical
    Original PDF
    breakers
    TECHNICAL DATA SHEET Sentry Miniature Circuit Breakers 1:3 Sentry® MCBs Description PRODUCT RANGE Sentry MCBs are of the thermo-magnetic, current limiting type and are available with either Type B or Type C operating characteristics. Type B Single pole Rating
    Original PDF
    1du16
    MINIATURE CIRCUIT BREAKERS (MCBs) UL Recognized Supplementar y Pr otectors vs. UL Listed Manual Motor Contr ollers D4A D 16A I 277V AC 277V AC 10000 1D4.0 1DU16 I 10kA LISTED 4C87 ® UL Recognized UL Listed UL Recognized one pole supplementary protector UL Listed one pole manual motor controller
    Original PDF
    wylex
    Circuit Protection 2003 Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today. From its base at Wythenshawe, through
    Original PDF
    wylex
    domestic commercial industrial circuit protection Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today across the world.
    Original PDF
    Altech UL1077 Altech UL1077/508 Busbar System
    Altech UL1077 Altech UL1077/508 Busbar System UL508 listed E205412 UL508 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Manual Motor Controllers (MMC) and Supplementary Protectors (SP). The advantages of this busbar
    Original PDF
    42062 GE Consumer & Industrial Power Protection
    42062 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection The Power Protection division of GE Consumer & Industrial is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components,
    Original PDF
    mcb-01
    Accessories Auxiliary contact block Order Code MCB-01 MCB-10 Type 1) For switch type 1-pole making 10 A, 690 V 1SFA611610R1001 MCB-10 KSE225…340, BE and BW325, 340, 625 1-pole breaking 10 A, 690 V 1SFA611610R1010 MCB-01 KSE225…340, BE and BW325, 340, 625
    Original PDF
    s270
    Line Protection Devices MCB- S270 & S260 series Conforms to IEC60898, IS8828-10kA and IEC60947-2 ABB- the pioneer in MCB technology brings to you the S270 range based on system pro M, a modular system developed by ABB. The S270 range of MCBs are designed and constructed to
    Original PDF
    S e n t r y Technical 661 | circu it p ro tectio
    S e n t r y Technical 661 | circu it p ro tectio n technical ho tline + 4 4 (0 )1 26 8 5 6 3 7 20 M in ia tu re C irc u it B re a k e rs (M C B s ) S t a n d a rd s a n d a p p ro v a ls Sentry MCBs are designed to fu lly c om p ly w ith th e relev ant req u irem ents of BS E N 6 0 8 9 8 : 20 0 3 .
    Original PDF
    motores
    Guardamotores MS Con protección contra sobrecarga y cortocircuito, sensibilidad al fallo de fase de acuerdo a IEC 947-4-1, DIN VDE 0660 Part 102 Debido a su alta capacidad de ruptura con alta limitación de corriente, los guardamotores MS suministran una óptima protección para motores
    Original PDF