0X0041E Search Results
0X0041E Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
chilled water systemContextual Info: Data Sheet, Revision 3 September 21, 2005 TSI-2 2k x 2k Time-Slot Interchanger 1 Introduction The last issue of this data sheet was August 31, 2005. A change history is included in Section 11 Change History on page 61. Red change bars have been installed on all text, figures, and tables that were added or changed. All changes to the text |
Original |
condit138 DS05-116STSI-3 DS05-116STSI-2) chilled water system | |
Contextual Info: Register Description June 2004 STSI-48 Scalable Time-Slot Interchanger Register Description 1 Introduction 1.2 STSI-48 Addressing Notes This document defines the address map for the scalable time-slot interchanger STSI-48 and describes the purpose and operation of each register bit, its dependencies, and its initial state. |
Original |
STSI-48 16-bit DS04-216SWCH DS03-177SWCH) | |
Contextual Info: Data Sheet May 27, 2005 TSI-4 4k x 4k Time-Slot Interchanger 1 Introduction This document consists of two major sections: The TTSI004161 device hardware description. This section contains ball information, operating conditions, dc electrical characteristics, timing diagrams, ac characteristics, and packaging information. |
Original |
TTSI004161 TTSI-144 0A-301C, DS05-117STSI | |
RXD03Contextual Info: Data Sheet May 27, 2005 TSI-1 1k x 1k Time-Slot Interchanger 1 Introduction This document consists of two major sections: The TTSI001041 device hardware description. This section contains ball information, operating conditions, dc electrical characteristics, timing diagrams, ac characteristics, and packaging information. |
Original |
TTSI001041 TTSI-144 0A-301C, DS05-115STSI RXD03 | |
0x0041CContextual Info: Advisory July 2002 STSI-144 Scalable Time-Slot Interchanger Introduction TXD Precharge Resistors This document describes technical issues that are known to exist with the device and/or the documentation of the device. TXD[23:00] are not properly equipped with precharge |
Original |
STSI-144 DS02-095SWCH 0x0041C | |
Contextual Info: Advisory May 2003 TSI8K Scalable Time-Slot Interchanger Introduction This document describes technical issues that are known to exist with the device and/or the documentation of the device. Issues With Version 1 Devices TXD Buffer Strength The TXD[63:00] output buffers are capable of excessive output drive, resulting in excessive overshoot and |
Original |
DS03-125SWCH DS02-095SWCH) | |
automatic WATER LEVEL pump CONTROL
Abstract: chilled water system
|
Original |
condit138 DS05-115STSI-3 DS05-115STSI-2) automatic WATER LEVEL pump CONTROL chilled water system | |
0x0041E
Abstract: csg 6522 TSI-16 0x0040c 0X00002
|
Original |
TSI-16 DS02-074SWCH DS02-064BBAC) 0x0041E csg 6522 0x0040c 0X00002 | |
SF 150 U11 4K
Abstract: ts50 chilled water system
|
Original |
condit138 DS05-117STSI-3 DS05-117STSI-2) SF 150 U11 4K ts50 chilled water system | |
Contextual Info: Data Sheet May 27, 2005 TSI-2 2k x 2k Time-Slot Interchanger 1 Introduction This document consists of two major sections: The TTSI002081 device hardware description. This section contains ball information, operating conditions, dc electrical characteristics, timing diagrams, ac characteristics, and packaging information. |
Original |
TTSI002081 TTSI-144 0A-301C, DS05-116STSI | |
0x00418
Abstract: rxd40
|
Original |
TSI-16 Action10-12, DS02-075SWCH DS02-064BBAC) 0x00418 rxd40 | |
Contextual Info: Advisory July 2002 TSI-8 Time-Slot Interchanger Introduction TXD Precharge Resistors This document describes technical issues that are known to exist with the device and/or the documentation of the device. TXD[23:00] are not properly equipped with precharge |
Original |
DS02-123SWCH |