Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    0637A Search Results

    SF Impression Pixel

    0637A Price and Stock

    Select Manufacturer

    ECS International Inc ECS-300-6-37-AGN-TR

    - Tape and Reel (Alt: ECS-300-6-37-AGN-TR)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas ECS-300-6-37-AGN-TR Tape & Reel 19 Weeks 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 $0.28
    • 10000 $0.23
    Buy Now

    ECS International Inc ECS-480-6-37-AGN-TR

    - Tape and Reel (Alt: ECS-480-6-37-AGN-TR)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas ECS-480-6-37-AGN-TR Tape & Reel 19 Weeks 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 $0.27
    • 10000 $0.25
    Buy Now

    CTS Corporation CER0637A

    - Tape and Reel (Alt: CER0637A)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas CER0637A Tape & Reel 7 Weeks 500
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    ECS International Inc ECS-400-6-37-AGN-TR

    - Tape and Reel (Alt: ECS-400-6-37-AGN-TR)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas ECS-400-6-37-AGN-TR Tape & Reel 19 Weeks 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 $0.26
    • 10000 $0.25
    Buy Now

    EAO AG 09-400001.10637A

    Pb Switch, Spst-No, 0.05A, 12Vdc, Panel; Switch Operation:Momentary; Contact Configuration:Spst-No; Illumination:Illuminated; Switch Mounting:Panel Mount; Actuator/Cap Colour:Black; Product Range:09 Universal Series; Ip Rating:Ip54Rohs Compliant: Yes
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark 09-400001.10637A Bulk 15 1
    • 1 $28.86
    • 10 $27.71
    • 100 $25.97
    • 1000 $25.40
    • 10000 $24.82
    Buy Now
    RS 09-400001.10637A Bulk 12 Weeks 5
    • 1 -
    • 10 $30.34
    • 100 $30.34
    • 1000 $30.34
    • 10000 $30.34
    Get Quote
    Sager 09-400001.10637A 5
    • 1 -
    • 10 $25.37
    • 100 $22.28
    • 1000 $21.70
    • 10000 $21.70
    Buy Now
    TME 09-400001.10637A 4
    • 1 -
    • 10 $22.03
    • 100 $22.03
    • 1000 $22.03
    • 10000 $22.03
    Get Quote
    Neutron USA 09-400001.10637A 15
    • 1 $59.99
    • 10 $59.99
    • 100 $59.99
    • 1000 $59.99
    • 10000 $59.99
    Buy Now

    0637A Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    MF-0637A-60BL

    Contextual Info: MF-0637A-60BL LINE Operating Voltage = 48 Vdc Operating Current = 60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Safety Agency Approval = TUV CSA Canada Y US


    Original
    mf-0637a-60blmm-0637a-60blcaldwell100 PDF

    Contextual Info: MM-0637A-50C This filter features a very small mechanical package with a very good common mode insertion loss and differential loss. LINE LOAD This filter has been designed to operate with severe unbalanced current loading and can withstand up to a 30% unbalance in line and return without degrading the


    Original
    mm-0637a-50c PDF

    Contextual Info: MM-0637A-40D Operating Voltage = 48 Vdc Typical Operating Voltage Max. = 0—75Vdc Operating Current = 40 Amp Operating Temp Range = -40 to 50 C (see chart) Storage temperature = -55—100 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute


    Original
    mm-0637a-40d0--75vdc PDF

    Contextual Info: MM-0637A-50C Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Order P/N: LOAD LINE MM-0637A-50C Safety Agency Approvals


    Original
    mm-0637a-50c PDF

    Contextual Info: MM-0637A-60D Operating Voltage = 48 Vdc Typical Operating Voltage Max. = 0—75Vdc Operating Current = 60 Amp Operating Temp Range = -40 to 50 C (see chart) Storage temperature = -55—100 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute


    Original
    mm-0637a-60d0--75vdc PDF

    MM-0637A-40C

    Abstract: MM-0637A-60C
    Contextual Info: MM-0637A-40C, -50C, -60C Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min 40 Amps Order P/N: MM-0637A-40C


    Original
    mm-0637a-40cmm-0637a-50cmm-0637a-60cmm-0637a PDF

    MF-0637A-60BR

    Contextual Info: MF-0637A-60BR This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss are more than is available in other similarly sized packages. LINE LOAD This filter has additionally been designed to operate with


    Original
    mf-0637a-60br PDF

    MF-0637A-50BL

    Contextual Info: MF-0637A-50BL This EMI / RFI filter features a very small mechanical pack age. T he comm on m ode insertion loss and differential loss is more than is available in other similarly sized packages. This filter has additionally been designed to operate with severely unbalanced current loading. It can withstand up


    Original
    mf-0637a-50blmm-0637a-50bl PDF

    Contextual Info: MM-0637A-40D, 50D, 60D This filter features a very small mechanical package with excellent common mode and differential insertion loss. LINE LOAD This filter has been designed to operate with severely unbalanced current loading and can withstand up to a 30% unbalance in line and return without degrading the


    Original
    mm-0637a-40dmm-0637a-50dmm-0637a-60dmm-0637a PDF

    MM-0637A-100

    Abstract: JMK Filters
    Contextual Info: MM-0637A-100 Operating Voltage = 48 Vdc Operating Current Max = 100 Amp Temperature Range(Storage) = -55 TO 85 C Temperature Range(Operating) = -20 TO 50 C Diel. Withstand Voltage (Term - Case) = 1500 Vdc Diel. Withstand Voltage ( + to - ) = 707 Vdc This filter is the 100 amp version of our 637A


    Original
    mm-0637a-100jmk filters PDF

    Contextual Info: MF-0637A-50BL Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min LINE LOAD Safety Agency Approval = TUV,


    Original
    mf-0637a-50blmm-0637a-50bl PDF

    Contextual Info: MM-0637A-50B LOAD LINE Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Order P/N: MM-0637A-50B Safety Agency Approvals


    Original
    mm-0637a-50b PDF

    Contextual Info: MM-0637A-40B, -50B, -60B Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min 40 Amps Order P/N: MM-0637A-40B


    Original
    mm-0637a-40bmm-0637a-50bmm-0637a-60bmm-0637a PDF

    MF-0637A-50BR

    Contextual Info: MF-0637A-50BR This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss are more than is available in other similarly sized packages. LINE LOAD This filter has additionally been designed to operate with


    Original
    mf-0637a-50brmm-0637a-50brmf-0637a-50bl PDF

    Contextual Info: MF-0637A-50BR This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss are more than is available in other similarly sized packages. This filter has additionally been designed to operate with


    Original
    mf-0637a-50br PDF

    0-75VDC

    Contextual Info: MM-0637A-50D Operating Voltage = 48 Vdc Typical Operating Voltage Max. = 0—75Vdc Operating Current = 50 Amp Operating Temp Range = -40 to 50 C (see chart) Storage temperature = -55—100 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute


    Original
    mm-0637a-50d0--75vdc0-75vdc PDF

    Contextual Info: MF-0637A-60BR LINE Operating Voltage = 48 Vdc Operating Current = 60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Safety Agency Approval = TUV CSA Canada Y US


    Original
    mf-0637a-60brmm-0637a-60brmm-0637a PDF

    Contextual Info: MM-0637A-40B, -50B, -60B This EMI / RFI filter features a very small mechanical package with a very good common mode insertion loss and differential loss. LINE LOAD This filter has been designed to operate with severe unbalanced current loading and can withstand up to a


    Original
    mm-0637a-40bmm-0637a-50bmm-0637a-60bmm-0637a PDF

    tsop tray matrix outline

    Abstract: tsop Shipping Trays JEDEC Matrix Tray outlines Atmel 918 EIA-481-x ATMEL Packing Methods and Quantities JEDEC Matrix Tray outlines soic ATMEL Tape and Reel PLCC JEDEC tray Shipping Trays
    Contextual Info: Packages Available Packing Methods and Quantities Atmel provides four different packing methods to provide maximum protection for our product and to best suit our customer’s needs: 1 Shipping Tubes, 2) Shipping Trays, 3) Unit Packing, and 4) Tape and Reel. These first three methods are our standard pack, but we also


    Original
    tsop tray matrix outlinetsop shipping traysjedec matrix tray outlinesatmel 918+6eia-481-xatmel packing methods and quantitiesjedec matrix tray outlines soicatmel tape and reelplcc jedec trayshipping trays PDF