500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
BQ27500CSPT-V130 Texas Instruments 1-CHANNEL POWER SUPPLY SUPPORT CKT, BGA12, CSP-12 visit Texas Instruments
BQ27500DRZR Texas Instruments System-Side Impedance Track™ Fuel Gauge 12-SON -40 to 85 visit Texas Instruments
BQ27500DRZT-V100 Texas Instruments System-Side Impedance Track™ Fuel Gauge 12-SON -40 to 85 visit Texas Instruments
BQ27500DRZT-V100G4 Texas Instruments System-Side Impedance Track™ Fuel Gauge 12-SON -40 to 85 visit Texas Instruments
BQ27500DRZR-V130 Texas Instruments System-Side Impedance Track™ Fuel Gauge 12-SON -40 to 85 visit Texas Instruments
BQ27500YZGT-V130 Texas Instruments System-Side Impedance Track™ Fuel Gauge 12-DSBGA -40 to 85 visit Texas Instruments

wc 27500 color code

Catalog Datasheet MFG & Type PDF Document Tags

m27500

Abstract: nema wc 27500 WC 27500 for the NEMA part numbers specified herein. Revision A COMPONENT WIRES ­ RCW5991 , Dielectric Test: 6.0 kV (peak) IDENTIFICATION OF PRODUCT (not required for AWG 26): Per WC 27500, mark the white component wire with NEMA part number and Raychem CAGE code as follows (mark the other , part numbers above shall be replaced by a dash or a letter designator from WC 27500 to indicate the , and blue. Component wire colors are in accordance with the UV laser markable color limits specified
Tyco Electronics
Original
24WP2U00 22WP2U00 16WP2U00 M27500A20WP2U00 m27500 nema wc 27500 TYCO M27500 m27500- color code m27500a WP2U00 WP2U00-26 WP2U00-24 WP2U00-22 WP2U00-20 WP2U00-18

m27500

Abstract: SAE AS 27500 requirements of NEMA WC 27500 for the NEMA part numbers specified herein. COMPONENT WIRES ­ RCW5991 , in the part numbers above shall be replaced by a dash or a letter designator from WC 27500 to , specified in SAE AS22759/91. 2/ The "*" in the Raychem part numbers above shall be replaced by a color code , with any specification, without notification to Buyer. 2/ COLOR CODE DESIGNATORS SHALL BE IN , seconds (maximum), 3 inches (maximum) IDENTIFICATION OF PRODUCT: Per WC 27500, the NEMA part number and
Tyco Electronics
Original
22WP2G24 12WP2G24 SAE AS 27500 nema wc 55 m27500 a NEMA-WC-27500 nema wc bend wc 27500 WP2G24 WP2G24-26- WP2G24-24- WP2G24-22- WP2G24-20- WP2G24-18-

m27500 sd

Abstract: MIL-DTL-27500 Mil-DTL-27500 Mil-DTL-27500 All Mil-DTL-27500 cables are designated by a seven digit code that , Mil-DTL-27500. 2. Shield Coverage and Color Identification- a slash followed by a dash (-) or letter code indicates both shielding coverage and the method of color identification of primary core , are identified by a two letter code. Cables utilizing Judd Wire's components are detailed in Table B , 6 7 designated by a single letter code. Detailed in Table C. 7. Jacket- Cable jacketing
Judd Wire
Original
m27500 sd MIL-DTL-27500 MIL-W-22759 JUDD WIRE m27500-22SB solid insulation materials

m27500

Abstract: nema wc 27500 WC 27500 for the NEMA part numbers specified herein. Revision A COMPONENT WIRES ­ RCW5991 , Dielectric Test: 6.0 kV (peak) IDENTIFICATION OF PRODUCT (not required for AWG 26): Per WC 27500, mark the white component wire with NEMA part number and Raychem CAGE code as follows (mark all other , part numbers above shall be replaced by a dash or a letter designator from WC 27500 to indicate the , , blue and orange. Component wire colors are in accordance with the UV laser markable color limits
Tyco Electronics
Original
20WP3U00 18WP3U00 M27500A20WP3U00 WC-27500 m27500-16 wc 27500 color code m27500-20 WP3U00 WP3U00-26 WP3U00-24 WP3U00-22 WP3U00-20 WP3U00-18

thermorad

Abstract: wc 27500 85% minimum (each) 200 ± 5 °C for 6 hours per WC 27500. (Post Environmental) 1000 volts (rms), 60 , when applicable per WC 27500. Coax Components to their own SCD Spark Test: 1 kV (rms) Impulse Dielectric Test: 6.0 kV (peak) Notes Colors Dimensions Identification, Colors & Marks Colors and color code designators shall be in accordance with MIL-STD-681. Dimensions are in inches, and unless , cable on Page 1. Line 1: Identifies the component per the components' ID list. Line 2: Color codes. Line
Tyco Electronics
Original
thermorad all Wire and Cable specification sheet spec 44 wire RAYCHEM 44A THERMORAD COAX 44A011 44A9111 44A0111-16 44A0111-20 FIL-30-0 1-800-2-RAYCHEM

AS22759

Abstract: MIL-STD-1916 Procedure 4.6.1 4.6.6 4.6.6 4.6.6 4.6.2 4.6.3 and 4.6.6 AS22759 WC 27500 4.6.6 4.6.4 4.6.5 WC , 4.6.6 4.6.11 4.6.12 4.6.6 WC 27500 4.6.3 and 4.6.6 4.6.13 4.6.15 4.6.6 Material Specific , materials shall conform to the requirements specified in WC 27500 and the applicable SCD. 3.1.2 , hours. Finished cable shall be tested in accordance with WC 27500 at 230 ± 3°C for 4 hours. 4.6.2 , withstand test shall be as specified herein (4.6.14). Finished cable shall be tested in accordance WC 27500
Tyco Electronics
Original
MIL-STD-1916 55PC0211 MIL-STD-104 55PC011X 55PC1221-22 FED-STD-228

FED-STD-191

Abstract: AS22759 AS22759 WC 27500 4.6.5 4.6.4 WC 27500 4.6.5 4.6.6.2 4.6.6.1 4.6.7 AS22759 4.6.5 ASTM D 3032, Section 16 4.6.5 4.6.8 4.6.9 4.6.3 4.6.8 4.6.5 4.6.10 4.6.11 4.6.12 4.6.5 WC 27500 4.6.3 and , specified in WC 27500 and the applicable SCD. 3.1.2 Conductor Elongation and Break Strength , AS22759 at 230 ± 3°C for 4 hours. Finished cable shall be tested in accordance with WC 27500 at 230 ± 3 , in accordance WC 27500 at -85 ± 2°C for 4 hours, using the applicable mandrel and test load
Tyco Electronics
Original
FED-STD-191 NASA SP-R-0022 Sample form for INCOMING Inspection of RAW MATERIAL RAW MATERIAL SPECIFICATION SHEET for cosmetic products INCOMING RAW MATERIAL INSPECTION INCOMING RAW MATERIAL INSPECTION procedure

E303150

Abstract: MIL-STD-104 .) 2.2.3 National Electrical Manufacturers Association (NEMA) WC 27500 Standard for Aerospace and , materials shall conform to the requirements of WC 27500 and the applicable specification sheet. 3.3 , Finished wire insulation color code designators shall be as specified in Table 3. Colors for DW finished , WC 27500 P Shield Material and Construction Specification Sheet and 3.2.3 WC 27500 P , UNCONTROLLED COPY. Page 6 of 14 SPECIFICATION WCD 3106, ISSUE 10 TABLE 3. FINISHED WIRE COLOR CODE
Tyco Electronics
Original
E303150 astm B1 WCD3106 ll339 875R file cable medium voltage xlpe LL33902
Abstract: Specification 44 and NEMA WC 27500 as applicable. SHIELD- COPPER, COATED AS ON CONDUCTOR EXCEPT TIN COATED , AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681 HOWEVER, DUE TO LENGTH LIMITATIONS OFTH E RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS , replaced by color code designators with a slash separating the component wire colors and a dash separating , dielectric breakdown JACKET COLOR: W hite preferred JACKET CONCENTRICITY: 70% (minim um) JACKET ELONGATION -
OCR Scan
44AM114X 25APR11 44AM114X-26- 44AM114X-24- 44AM114X-22- 44AM114X-20-

nema wc 27500

Abstract: NEMA-WC-27500 the latest issue of Raychem Specification 44 and NEMA WC 27500 as applicable. COMPONENT WIRES - , notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902." MAY BE REPLACED BY "Axxx".) OTHER CODES AND SUFFIXES MAY , copper alloy (AWG's 26-20 only) The "*" in the part numbers on page 1 shall be replaced by color code
Tyco Electronics
Original
44AM1141-24 44A011X 44AM114X-18- 44AM114X-16- 44AM114X-14- 44AM114X-12- 44AM1141-24-0/1/2/3-9

MIL-DTL-27500

Abstract: M22759/34 numeric color code designations 4 JUDD WIRE Turners Falls, MA San Marcos, CA (413) 863-4357 , 3.3 4.8 2.53 3.42 4.91 7.14 *Replace the asterisks with numeric color code designations , 2.08 2.98 4.32 6.55 *Replace the asterisks with numeric color code designations www.juddwire.com , is used to designate Mil-DTL-27500. 2. Shield Coverage and Color Identification- a slash followed by a dash (-) or letter code indicates both shielding coverage and the method of color identification
Judd Wire
Original
M22759/34 m27500 transfer impedance MIL-W-81381 M27500- twisted pair MIL-W-22759/44 XLETFE

BMS 13-48

Abstract: m27500-22SB * = A or PC X = no. of wire components Y = color code For complete part number, see Part Numbering , Cable SPEC 55 (Continued) NEMA WC-27500 Cable Part Numbering System M27500 X AWG XX X X XX Basic , , 0.25 [.010] (55A08XX 10 mil) and 0.2 [.008] (55A02XX 8 mil). Both have a contrasting core color to act , MIL-W-22759/32-35 and /41 to /46 and NEMA-WC-27500 (Cables) Defense Standard 61-12 Part 33 Issue 4 Part , Cable SPEC 55 (Continued) Part Numbering System 55 X X X X X- Size- X/X- X Jacket Color (in
Tyco Electronics
Original
M27500-22SB3T23 BMS 13-48 Boeing Spec BSS 7324 BMS13-48 BMS 13-48 TYPE 10 CLASS 1 ST 9427 BMS1348 55A0111 55A0114 55A0811 55A8039 55A0814

M81044

Abstract: M27500- twisted pair (cadmium-free) Conductor Size (AWG) Primary Wire Insulation Color (code per MIL-STD-681) 0 - Black 5 - , UK: 44-1793-528171 High Performance Wire and Cable SPEC 44 (Continued) NEMA WC-27500 Cable , , MIL-W-81044 5.54 grams/meter max Specifications/Approvals MIL-W-81044, NEMA-WC-27500 (Cables) Def , Color (codes same as for Primary Wire Insulation Color) * Classes 4, 5 and 6 available only as "44/" , Coverage Code Shield Coverage 85% 90% A B F D E H G K L P S Component Wire
Tyco Electronics
Original
M81044 m27500-22ML3T08 m27500-22ml M81044/12 bs G210 S424 44A112X 44A181X

BMS 13-48

Abstract: bms13-48 . of wire components Y= color code For complete part number, see Part Numbering System on page 9-15 , (Continued) NEMA WC-27500 Cable Part Numbering System Example: 9-18 Catalog 1654025 Revised 12-03 , ] (55A08XX 10 mil) and 0.2 [.008] (55A02XX 8 mil). Both have a contrasting core color to act as a damage , insulation system - dual wall MIL-W-22759/32-35 and /41 to /46 and NEMA-WC-27500 (Cables) Defense
Tyco Electronics
Original
18X2-AWG-Y mil spec M22759 MIL-W-22759/32 BMS-1348 AIRbus BMS13-48 BMS13 M22759/41 55/03XX 18X6-AWG-Y 11X1-AWG-Y 18X1-AWG-Y 11X2-AWG-Y

RK618

Abstract: LOCTITE 3623 Tubing or molded parts can be color-matched to the original color of fiber, wire insulation, or other , cable is severed and access to the ends is prevented, unique identification on the wires, or wire color , International Protection (IP) Code. Stress and Strain Wires that are attached to the connector pins need help to
Tyco Electronics
Original
RK618 LOCTITE 3623 DBAS 970 25 35 PN 059 S-CH00-0157-002 ANSI-MC-96 LOCTITE 3542

Burndy PAT750-18V parts breakdown

Abstract: BURN GI CONDUIT Color Match System The SmartCart® and BURNDY® Wire Caddies Experience. Technology. Answers. TM
Burndy
Original
Burndy PAT750-18V parts breakdown BURN GI CONDUIT lp 1610 for door bell Burndy Y35 hypress parts breakdown ci an 7591 KPC 45 94V

AWM 2851 VW-1

Abstract: Semicon volume 1 '  CHTC® 4100â'  CHTC® XLPE/XL-CPE, Control, Unshielded 600 V, UL Type TCâ'"E-2 Color Code XLPE/XL-CPE, Control, Unshielded 600 V, UL Type TCâ'"E-1 Color Code XLPE/XL-CPE, Low-Voltage Power, Unshielded 600 V, UL Type TC-ERâ'"Method 4 Color Code Nov. 2014 Nov. 2014 600 V Multi-Conductor , , UL Type TC-ERâ'"E-2 Color Code FR-EPR/CPE, Control, Unshielded 600 V, UL Type TC-ERâ'"E-1 Color Code FR-EPR/CPE, Control, Shielded 600 V, UL Type TC-ER, Overall Shieldedâ'"E-2 Color Code FR-EPR
General Cable
Original
AWM 2851 VW-1 Semicon volume 1 INS-0043-R0415

220v AC voltage stabilizer schematic diagram

Abstract: BA 49182 1 N O New Product Denoted In Color PRODUCT INDEX ~A~ AC Line Cords . . . . . . . . . , . . . . . . . . . . . . . . . . . . 433 Camera Color/B&W CCD . . . . . . . . . . . . . . . . . . .
DigiKey Electronics Catalog
Original
220v AC voltage stabilizer schematic diagram BA 49182 RJh 3047 rjh 3047 equivalent a1458 opto philips ecg master replacement guide P390-ND P465-ND P466-ND P467-ND LNG901CF9 LNG992CFBW

stk 412 -420

Abstract: Ignitron BK 496 the 48 states and island ot Oahu in Hawaii. To calculate UPS charges, use the Parcel Post Zip Code , 6.80 8.18 100 7.44 | 8.89 11.54 14.14 17.74 21.84 26.44 ZIP CODE/ZONE CHART Use Your Zip Code To Find Your Parcel Post Or UPS Zone Zip Code Prefixes Zone Zip Code Prefixes Zone Zip Code Prefixes Zone Zip Code Prefixes Zone Zip Code Prefixes Zone Zip Code Prefixes Zone 006-009 8 298-299 5 439 4 , digits of your Zip Code to determine your Parcel Post Zone. Example: If your Zip Code is 16606, use the
-
OCR Scan
stk 412 -420 Ignitron BK 496 CD4004AE STK 419 150 10CW5 varistor 472 SUS 2G700 9799-G 018C1
Showing first 20 results.