500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
CONTROLSUITE Texas Instruments controlSUITE visit Texas Instruments
LM49100CONTROL-SW Texas Instruments LM49100 Control Software visit Texas Instruments
PRECISIONAMPLITUDECONTROL-INVALID Texas Instruments Precision Amplitude Control for Analog Video visit Texas Instruments
MOTIONFIRE-MOTORCONTROL-REF Texas Instruments Motionfire Motor Control Reference Design (FireDriver Module) visit Texas Instruments
PRECISIONAMPLITUDECONTROL-REF Texas Instruments Precision Amplitude Control for Analog Video visit Texas Instruments
ISL71823ASRHVD Intersil Corporation SWITCHING CONTROLLER visit Intersil

triac arc control

Catalog Datasheet MFG & Type PDF Document Tags

RC firing circuit FOR SCR

Abstract: triac arc control into bilateral diode connected to power Triac gate for stable, full-range control. Mains Frequency , Control · Product Range:120-240 VAC, 5-25 amps. R · Application: esistance Loads FEATURES · · , Heater Control Light Dimming Hot-Wire Cutting Heat Sealing and Packaging Plastic Molding and Extruding Food Preparation Equipment Model 18TBP/TB controls provide infinitely variable control of , Triacs replace contacts and brushes to control electric power without moving parts, and, when operated
Payne Engineering
Original
RC firing circuit FOR SCR triac arc control TRIAC single-phase heater temperature control scr three phase heater control schematic three phase triac control 18TBP 18TBP-1-5 18TBP-1-10 18TBP-1-15 18TB-1-15 18TB-1-25

triac diac applications circuit diagram

Abstract: power variation circuit for arc welding ® APPLICATION NOTE CONTROL BY A TRIAC FOR AN INDUCTIVE LOAD HOW TO SELECT A SUITABLE CIRCUIT , . Nevertheless many users still encounter difficulties when designing triac control circuits which are to be , sensitive auxiliary triac is used to produce the pulse train necessary for maintaining the control signal , CONTROL BY TRIAC FOR INDUCTIVE LOADS SUMMARY OF SOLUTIONS A SYNCHRONOUS TRIGGERING ACROSS THE TRIAC , of the control and thus of the duration of the current flow in the previous direction. The triac
STMicroelectronics
Original
D89AN308-01 triac diac applications circuit diagram power variation circuit for arc welding arc welding transformer triac pulse train triggering welding transformer triac diac applications circuit diagram inductive AN308/0289 D89AN308-02

TRIAC BTB 12.600

Abstract: triac firing pulse generating circuit APPLICATIONS Example 1: Control of a Low Power Signalling Lamp by Triac Figure 2. Control of a Low Power , current IG. The triac does not conduct. A BTA 12.400 B triac is used to control the flashing of a 10 W , NOTE Example 2: Control of an inductive load by triac Figure 3. Voltage Accross and Current Through the Triac M IT A2 IG VT A1 G Control of an AC motor by triac IG Gate current , number of triac control circuits, specially designed to work on inductive loads (see Bibliography, ref. N
STMicroelectronics
Original
TRIAC BTB 12.600 triac firing pulse generating circuit triac BTA 12-400 HOLDING CURRENT TRIAC BTA 12,600B TRIAC BTB 16.600 triacs BTA 06.600 T AN303

welding transformer SCR

Abstract: scr arc welding control schematic examples. 1.1 Example 1: low power lamp control In the application circuit shown in Figure 2 a TRIAC , Example 2: inductive load control When a TRIAC controls an inductive load (L), the rise of the load , current. The control mode shown in Figure 3 is a square pulse. Another TRIAC control mode is to apply a gate pulse train. Application note AN308 offers some TRIAC control circuits specially designed to work , 3: varying power load control For most applications, the load power is controlled by the TRIAC
STMicroelectronics
Original
welding transformer SCR scr arc welding control schematic ac motor triac bta12 circuit diagram triac applications circuit diagram triac bta12 triggering triac arc welding

TRIAC BTB 12.600

Abstract: triac arc control of a load whose power varies considerably. Figure 4 : Control of an Arc Welding Set by Triac , APPLICATIONS Example 1 : Control of a low power signalling lamp by triac. Figure 2 : Control of a Low Power , of the gate current IG. The triac does not conduct. A BTA 12.400 B triac is used to control the , mA). APPLICATION NOTE Example 2 : Control of an inductive load by triac. Figure 3 : Voltage , SGS-THOMSON Microelectronics applications laboratories have developed a number of triac control circuits
STMicroelectronics
Original
TLS106-6 TRIAC BTB 12.600 data sheet SGS Z0102MA TRIAC BTB 04 thyristor firing circuit sgs Thomson Thyristor AN303/0495 D89AN303-02

DIAC DB2

Abstract: D1 DB2 Diac AN308 Application note TRIAC analog control circuits for inductive loads Introduction The TRIACs of today are well suited to the requirements of switching inductive loads. TRIAC control circuits , of this document is to present different methods of TRIAC control with their applications and to , Solutions summary for inductive load control A.1 AN308 Triggering synchronized across the TRIAC , function of the control and thus of the duration of the current flow in the previous polarity. The TRIAC
STMicroelectronics
Original
DIAC DB2 D1 DB2 Diac 1.5ke68a1 db1 diac DB2 Diac diac with triac ac motor speed control circuit diagram

triac diac applications circuit diagram

Abstract: TRIAC TLC 226 b AN308 APPLICATION NOTE CONTROL BY A TRIAC FOR AN INDUCTIVE LOAD HOW TO SELECT A SUITABLE CIRCUIT , . Nevertheless many users still encounter difficulties when designing triac control circuits which are to be , methods of triac control with their applications and to analyze their relative advantages and , VA ­ AN308 APPLICATION NOTE APPENDIX A. CONTROL BY TRIAC FOR INDUCTIVE LOADS SUMMARY OF , . TRIGGERING WITH SYNCHRONIZATION ACROSS THE TRIAC The triggering circuit with "synchronization across the
STMicroelectronics
Original
TRIAC TLC 226 b EQUIVALENT NO. OF DB3 DIAC DIAC DB3 EQUIVALENT TRIAC 226 b TLC226B diac triac control circuit motor 220 V

SD307

Abstract: SD307-D No. Symbol Description 1 LOW Soft wind output (driving TRIAC). 2 HEAD Swing head control output , supply. 18 LIGHT Lamp control output (driving TRIAC). 19 HIGH Strong wind output (driving TRIAC). 20 , swing, Lightening. There arc two ways to input these control signals: keypad of the control panel or , function. Power supply range : 4.0V~5.5V. An independent lamp control. Low power consumption. Remote , 11 â¡ u 20 DIP SD 307 Block Diagram Receiver A Control Logic -7%- Time Base T â'" V OSCI
-
OCR Scan
SD307 SD7017-455 SD307-A SD307-B SD307-C SD307-D 220V LED lamp circuit diagram d 1667 LED 220V lamp circuit triac application note fan speed control

Relay Matsushita

Abstract: Relay Matsua Triac Phototriac coupler No operation noise Most SSRs are SPST-NO Long life No arcing , of SSRs is that SSRs do not use switching contacts that will physically wear out. Triac Input , , capacitor, and varistor transistor, thyristor, and triac Semiconductor output element , Power transistor (for DC loads) Power MOS FET (for AC and DC loads) Thyristor (for AC loads) Triac , in synchronization. EMRs are not only mounted to control panels, but also used for a wide range of
-
Original
Relay Matsushita Relay Matsua TRIAC heater temperature control okita electromagnetic relay NEC varistor RS-485

36TBP-1-5

Abstract: Payne Engineering Company : full-wave single-phase bridge. Control Circuit: r-c network with variable resistance potentiometer adjusts firing capacitor into bi-lateral diode connected to power TRIAC gate for stable full-range control. Mains , WVYTE Model36TBP ENGINEERING DC Power Control Ri 29 â'¢ Scott Depot wv â'¢ 25560-0070 , element melt time, tmeit. b) peak melt current, lmeit. c) arc quench time. tare. d) peak arc current, larc , . Phase-angle control via power semiconductors varies the AC input voltage, which in turn is full-wave rectified
-
OCR Scan
36TBP-1-5 Payne Engineering Company 36TBP 36TPB 36TBP/11

temperature control circuit u217b

Abstract: U217B integrated circuit, U217B, is designed as a zero-voltage switch in bipolar technology. It is used to control resistive loads at mains by a triac in zero-crossing mode. Features Direct supply from the mains Current , V r4 100 k R5 15 k I 220 k (250 V~) A ramp generator allows power control function by period group control, whereas full-wave logic guarantees that full mains cycles are used for load switching. Simple power control Ramp generator Reference voltage Applications Full-wave power control Temperature
-
OCR Scan
U217B-X U217B-XFP BYT51G 1N4148 temperature control circuit u217b DIODE IN4007 triac TIC zero voltage switching adjustable ramp tic triac tic 236n IN4007 BYT86/800 U217B-XFPG3 05-NOV-99

ic t2117

Abstract: 3AS triac integrated circuit, T2117, is designed as a zerovoltage switch in bipolar technology. It is used to control resistive loads at mains by a triac in zero-crossing mode. A ramp generator allows power control function by period group control, whereas full-wave logic guarantees that full mains cycles are used for load , circuit T 2117 is a triac controller for zerocrossing mode. It is designed to control power in switching , pulse typ. 100 mA short-circuit protected Reference voltage · · Simple power control Ramp generator I
-
OCR Scan
T2117-TAS ic t2117 3AS triac t 430 nf 65 nf 06 kq 330 T2117-3AS T2117-TAQ BYT41M

zero crossing detector ic with 230v

Abstract: 1000w power amplifier circuit diagram triac controller for zero-crossing mode. It is meant to control power in switching resistive loads of , integrated circuit, U217B, is designed as a zero-voltage switch in bipolar technology. It is used to control resistive loads at mains by a triac in zero-crossing mode. Features â'¢ Direct supply from the mains â , Diagram A ramp generator allows power control function by period group control, whereas full-wave logic guarantees that full mains cycles are used for load switching. â'¢ Simple power control â'¢ Ramp generator
-
OCR Scan
zero crossing detector ic with 230v 1000w power amplifier circuit diagram DIAGRAM in 12v 1000w 1N4148V 1N4007 SM CNY21

triac ot 239

Abstract: TM 0134 led driver Isolator 2 Amp Zero-Cross Triac Output This device consists of an input (control) circuit optically coupled to a zero-cross triac driver circuit and a power triac. The input circuit contains a gallium , OPTOISOLATOR 2 AMP ZERO CROSS TRIAC OUTPUT 600 VOLTS CASE 417-02 Style 2 Symbol Value Unit PLASTIC PACKAGE OUTPUT TRIAC O ff-S tate Output Terminal Voltage - M aximum (1) Recomm ended Operating Voltage Range (f , Power Triac Junction to Case (See Fig. 12) Am bient Operating Temperature Range Storage Temperature
-
OCR Scan
triac ot 239 TM 0134 led driver mps 0734 AN 483 Motorola motorola triac TRIAC 109 UL508 CA77170-1 IEEE472 MOC2AV60 2PHX33605P-1 MOC2AV60/D
Abstract: . For phase control circuits employing SCR or TRIAC, etc. 54 g. Page 60 60 61 62 63 64 , oscillations. EFFECT OF SPARK QUENCHER Arc suppression Damping oscillation At the moment of switch opening, the RC combination absorbs and suppresses the energy of the arc by letting it bypass the switch , ) Electrical noise protection of semiconductor devices during control of triacs, thyristors, motors, welders , capacity. 5) When a thyristor, triac or invertor circuit is to be protected by a Spark Quencher, care Okaya Electric America
Original

IN4004 diode

Abstract: Allen-Bradley slc 150 the 20 processor unit. Like the processor unit, it has inputs and 12 outputs. Outputs include triac , isolation transformer mayalso be required. of A master control relay circuit should be included to , . Triac Outputs: Triac outputs include optical isolationwell as MOV as protection to guard against possible damage by transients from external outputs. Triac output firing can be synchronized with the to , arc suppression circuitry (RC networks) which protects contacts when switching inductive loads. We
-
Original
IN4004 diode Allen-Bradley slc 150 Allen-Bradley slc 100 1K4004 SLC150 SLC 150

Optocoupler with triac circuits

Abstract: DUAL OptoMOS Relay , process control, instrumentation and telecommunications, 252-1210 PAA150 250 250 7.0 13.29 replacing TRIAC , EACH control, security and instrumentation industries. As replacements for 1-Form-A No. Type (V) (mA , produce an alternative to optocoupler and 252-1120 PLA150 250 250 7.0 6.94 Triac circuits. Superior noise immunity complying with NEMA ICS 2-230 252-1130 PLA160 300 50 100.0 5.99 "showering arc" test is provided , environmental integrity make these devices suitable to control a variety of AC circuits including heaters
Allied Electronics Catalog
Original
PS2401 Optocoupler with triac circuits DUAL OptoMOS Relay 821 optocoupler optomos relay K3750 allied controls relays LCC110 LCC120 LCA210 LCA220 100-U PM1204

power SCR

Abstract: waveguide coupling with dual power SCR outputs to produce an alternative to optocoupler and Triac circuits. Superior noise immunity complying with NEMA ICS 2-230 "showering arc" test is provided along with advanced , control a variety of AC circuits including heaters, motors, solenoids, larger relays and contactors. CP , control, instrumentation and telecommunications, replacing T R IA C /d rive r, m echanical relays, and b , Current Operating Frequency Input Control Current Oflslate Leakage Current P0 12 01 /P S 12 H DVP/SIP 400
-
OCR Scan
power SCR PD2401/PS24 P026O1/PS26O1 PM1206 FDA21S 1-800-CPCLARE B86-2-2523-6368

Optocoupler with triac circuits

Abstract: aveguide coupling with dual pow er SCR outputs to produce an alternative to optocoupler and Triac circuits. Superior noise immunity complying with NEMA ICS 2-230 "showering arc" test is provided along with advanced , control a variety of AC circuits including heaters, motors, solenoids, larger relays and contactors. CP , program m able controls, process control, instrum entation and telecom m unications, replacing T R IA C /d , Package Type Peak Blocking Voilage Load Current Operating Frequency inpdi Control Current Ollstate Leakage
-
OCR Scan
PD2401/PS2401 PD2601/PS2601 PM1205 FDA215

SITAC

Abstract: OPTOCOUPLER for thyristor gate Triac AC switch) in SIPMOS technology provides an optically isolated interface between microelectronics , , its switching performance, particularly in phase control circuits, the trigger pulse current and high , high rates of voltage rise as are found in phase control, for instance. For 380-V line applications it , of such familiar components as a GaAs infrared diode on the input side and a photodetector and triac , control and load circuits, i.e. the result is an infrared triggered AC switch which can be used as an
Siemens
Original
SITAC OPTOCOUPLER for thyristor gate how to interface optocoupler with triac Triac 380v ac single phase 220v low power factor improve circuit diagram OPTOCOUPLER thyristor
Showing first 20 results.