500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
8406602XA Intersil Corporation 24 I/O, PIA-GENERAL PURPOSE, CQCC44 visit Intersil
8406602QA Intersil Corporation 24 I/O, PIA-GENERAL PURPOSE, CDIP40 visit Intersil
S4MF06607BSPZQQ1 Texas Instruments 16/32-Bit RISC Flash Microcontroller 100-LQFP -40 to 125 visit Texas Instruments Buy
TMS470MF06607BPZQ Texas Instruments 32-BIT, FLASH, 80MHz, RISC MICROCONTROLLER, PQFP100, GREEN, PLASTIC, LQFP-100 visit Texas Instruments
ISL32741EFBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EFBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil

thermistor VDE 0660

Catalog Datasheet MFG & Type PDF Document Tags

LT3SA00M

Abstract: LT3SA 60034-11-2 VDE 0660 IEC 60034-11-2 VDE 0660 IEC 60034-11-2 VDE 0660 Approvals CSA, UL (pending , Protection components General Thermistor protection units for use with PTC thermistor probes (positive temperature coefficient) Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor , off the machine or signal a fault (see paragraph relating to thermistor probes below). 2
-
Original

thermistor VDE 0660

Abstract: z1ms A~ Contact Fuse Protection (VDE 0660 Pt.2) 6 A quick acting/slow acting Operating Voltage UB = on , n , MS/220 V- Operating Voltage UB Z-80 Range Thermistor Protection Relay with automatic reset , PTC-thermistors for thermistor protection in accordance with DIN 44 081. 3.4.8 Pilz UK, Derbyshire House, Lower
-
OCR Scan
thermistor VDE 0660 z1ms Pilz UK DIN-44 081 Z1 MS PILZ ptc relay

3RN10

Abstract: siemens PTC thermistor relay characteristic of a PTC thermistor with a characteristic (Type A) according to DIN VDE 0660 Part 303 4000 R , Function Relays Thermistor Motor Protection SIMIREL 3RN1 for PTC temperature sensors Technical data Compact devices 3RN10 00 Type Standard devices 3RN10 10 3RN10 11 Multifunction devices 3RN10 12 Warning + switch-off Multiple motor protection 3RN10 13 3RN10 22 , storage temperature 2 0.145 No 0.145 0.260 Function Relays Thermistor Motor
-
Original
V0801 1BW10 DC-13 NSB00320 siemens PTC thermistor relay Thermistor 3rn1 simirel DIN VDE-0660 Part 303 DIN VDE-0660 AC-15 300/B

VDE 0660 3 phase switch

Abstract: 3 phase monitoring relays [] 3.600 2.500 1.500 Z2 PTC Type A DIN VDE 0660 Part 303 > < Switch off - Thermistor , A2 101 A1 Z1 Z2 A1~(+) Z1 B1 A2 Type A DIN VDE 0660 Part 303 > < 22 14 B1 B2 B2 21 Type A DIN VDE 0660 Part 303 > < Z2 Memory ON 35 78.8 , AC or 24 V AC/DC Z1 2.500 PTC Z2 21 B1 B2 > < Type A DIN VDE 0660 Part , .x.xxx.0300 71.92.x.xxx.0001 Thermistor temperature sensing relays for industrial applications 71.91 - 1 Pole
-
Original
VDE 0660 3 phase switch 3 phase monitoring relays transformer step down 230 V 50 Hz 9 V vde-0660 push button 220 volt ac relays switch circuit diagram C1114 C11-14

220 volt ac relays switch circuit diagram

Abstract: DIN VDE-0660 A2 101 A1 Z1 Z2 A1~(+) Z1 B1 A2 Type A DIN VDE 0660 Part 303 > < 22 14 B1 B2 B2 21 Type A DIN VDE 0660 Part 303 > < Z2 Memory ON 35 78.8 , L (+) N (­) A1 Z1 R [] 3.600 2.500 1.500 Z2 PTC Type A DIN VDE 0660 Part 303 , = 230 V AC or 24 V AC/DC Z1 B1 B2 > < Type A DIN VDE 0660 Part 303 1.500 1.000 , .x.xxx.0300 71.92.x.xxx.0001 Thermistor temperature sensing relays for industrial applications 71.91 - 1 Pole
-
Original

DIN 44082

Abstract: thermistor VDE 0660 VDE 0660 Part 302 and 303 ­ Connection for a thermistor ­ Integrated switching output , IB IL 24 TC INTERBUS Inline Thermistor Terminal Data Sheet 5659A 5 6 5 9 A 0 0 1 03/2000 , temperature thermistor) SC Red Short circuit of the thermistor or connecting cable A 1 Yellow Alarm message (Thermistor temperature approx. 5 K below response temperature) Terminal , 1 .2 Figure 2 1 Terminal Point Thermistor connection 1.3, 2.3 Not used 1.4
Phoenix Contact
Original
DIN 44082 starter voltage 75 kw thermistor terminal

220 volt ac relays switch circuit diagram

Abstract: thermistor VDE 0660 ) Z1 B1 A2 Type A DIN VDE 0660 Part 303 > < 22 14 B1 B2 B2 21 Type A DIN VDE 0660 Part 303 > < Z2 Memory ON 35 78.8 Z1 PTC Z2 21 PTC 96 , Type A DIN VDE 0660 Part 303 > < 11 14 A2 (­) 13 71 Series - Monitoring relays 10 , PTC Z2 21 B1 B2 > < Type A DIN VDE 0660 Part 303 1.500 1.000 Memory ON 11 24 , relays 10 A Features 71.91.x.xxx.0300 71.92.x.xxx.0001 Thermistor temperature sensing relays
-
Original
step down transformer 230 v to 12 v 1 mw 3phase transformer 50 Hz memoire Z-221

PTC Thermistor of siemens motor

Abstract: DIN 44082 than 250 . These points on the curve are zero-load resistances. DIN VDE 0660 (IEC 34-112) specifies , solutions that give the customer PTC thermistor technology plus sensor engineering from a single source , resistance of a PTC thermistor rises steeply, almost abruptly, in a narrow temperature range. Once a defined , for PTC thermistor technology and sensor engineering from a single source ­ from the ceramic powder , sensor. Fabrication counts The starting point of a PTC thermistor sensor is ceramic powder, which is
Siemens Matsushita Components
Original
PTC Thermistor of siemens motor PTC thermistor 5k siemens m155 thermistor ptc temperature sensor motor winding DIN 44081 siemens M155 PTC thermistor 44081/DIN AWG26

IEC 292-1

Abstract: 817A RELAY Impact Resistance According to AS, BS, VDE 0660 According to CSA, UL 2.5 kV, 50/60 Hz, 1 min. 5 kV , Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 · Accurate Temperature Monitoring , Description Bulletin 817 Thermistor Protection relays, utilized in conjunction with PTC thermistor sensors , with Voltage Suffix Code. UL Recognized 6-14 Bulletin 817 Thermistor Protection Relay , . Thermistor Protection relay 817-A Thermistor Protection relay plus manual/remote reset 817
-
Original
817-M IEC 292-1 817A RELAY IEC-34-11-2 Allen-Bradley 817-A IEC-34-1 199-DR1

MOELLER Z00 10

Abstract: dil3m80 -./FF250 ZW7 ZEV IEC/EN 60 947, VDE 0660, UL, CSA Damp heat, constant, to IEC 60 068-2-3 Damp , head spanner Tightening torque Z1 (Z1-75) IEC/EN 60 947, VDE 0660, UL, CSA Damp heat, constant , Climatic proofing Ambient temperature IEC/EN 60 947, VDE 0660, EN 55 011 Damp heat, constant, to IEC , Thermistor overload relays for machine protection 06/014 Accessories 06/011, 06/016 Tripping , -. 1­ 820 Thermistor overload relays for machine protection EMT6(DB)K) M580 M650 M750 M820
-
Original
3AM85 ZEV-XSW-820 MOELLER Z00 10 dil3m80 ZEV-XVK-20 DIL3AM85 EMT6DB HPL0211-2001/2002 4M115 4AM145

IEC 60947-5-1 400v 4kv

Abstract: thermistor VDE 0660 ): 3.6k Release value (relay in on-position): 1.8k Disconnection (short circuit thermistor): no Measuring voltage T1-T2: 2.5V DC at R 4.0k (in accordance with DIN VDE 0660 part 302) Overvoltage
Tele Haase
Original
IEC 60947-5-1 400v 4kv 1000VA G2TF02

LC1 D32 wiring diagram

Abstract: schneider overload relay lrd 25 Conforming to IEC 60801-5 °C °C IEC 60947-1, IEC 60947-4-1, NF C 63-650 VDE 0660, BS 4941 CSA, UL , , 255-17, VDE 0660 and EN 60947-4-1 UL 508 , CSA 22-2 IP 20 on front panel with protective covers LA9 , overload relays or thermal-magnetic motor circuit-breakers, b thermistor protection relays, with PTC thermistor probes (1) b multifunction relays. Protection by thermal overload relay A conventional , "¦) Motor protection Protection by PTC thermistor relay 4000 Better monitoring of the internal
Schneider Electric
Original
LC1 D32 wiring diagram schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload LC1 d32 contactor diagram schneider thermal overload relay lrd 32 MKTED205103EN D1020

Allen-Bradley contactor 100-C30 10

Abstract: Allen-Bradley contactor 100-C30 VDE 0660, EN 60 947, UL 508, UL 1053 Approvals 1.51 kg (3.33 lb) CE, CSA, PTB (pending), UL , Current Imbalance (asymmetry) Warning Settings Inputs Outputs Ground (Earth) Fault PTC Thermistor , · PTC Thermistor Input (E3 Plus) · Programmable Trip and Warning Settings · Diagnostic Functions , fault protection, PTC thermistor input, and additional I/O capabilities. Conformity to Standards , %. Feature E3 E3 Plus Inputs Outputs 2 1 4 2 Thermistor Input Ground Fault Protection
-
Original
Allen-Bradley contactor 100-C30 10 Allen-Bradley contactor 100-C30 rockwell E3 plus 193-EIMD 193-ECPM1 193-ECPM2 UL508 193-SG001B-EN-P 193-SG001A-US-P

crouzet 88 810.0 Automation Controls

Abstract: pc star ups SERVICE MANUAL pdf safe any fire fighting activities. Although VDE 0100-7-712 stipulates the use of a DC isolator, it , to Form 4 internal partitioning, and which take European and local (DIN, VDE, CEI, NF, UNE
EATON
Original
crouzet 88 810.0 Automation Controls pc star ups SERVICE MANUAL pdf EATON crouzet timer top 948 B10D Resistance fusible 4k7 J F0 D-53115 PU08703001Z-EN

ABB CONTACTOR EH 250

Abstract: abb EH 145 TA 75 DU IEC 947­4­1, VDE 0660, NFC 63 650, BS 4941, EN 60947­4­1 ­ onto contactor ­ with AB , Tripping class to IEC 947­4-1 / VDE 0660, Part 1021 Frequency range T/TA450 SU/T900 SU 3 Hz , (cont.) TA 80 DU TA 110 DU T/TA 200 DU T/TA 450 DU/SU T 900 DU/SU IEC 947­4­1, VDE 0660 , , temperature-dependent: Thermistor machine protection CUSTORAPID® Overload relays with protection device in case , finger-touch and safe from touch by the back of the hand to VDE 0106, Part 100. ABB 860 368 Type
ABB Stotz-Kontakt
Original
ABB CONTACTOR EH 250 abb EH 145 ABB CONTACTOR EH 370 ABB CONTACTOR EH 160 ABB CONTACTOR EH 260 ABB EH 250 ABB97003 ABB97004 ABB97006 ABB97005 D0201 ABB97009

catalog for 3RT series contactor* siemens

Abstract: catalog for 3tf series contactor* siemens to S3, up to 45 kW AC and DC operation IEC 60947, EN 60947 (VDE 0660) The 3RT1 contactors are
-
Original
catalog for 3RT series contactor* siemens catalog for 3tf series contactor* siemens 3RT siemens siemens contactor 3TF siemens magnetic contactor siemens contactor 3rt 3RT10 3RT12 3RA13 3RA14 3RT14 3RT13

5611A B

Abstract: siemens softstarter wiring diagram 3RW40 Exceptions: AC and DC operation 3RT19 26-1T . 00 and IEC 60947, EN 60947 (VDE 0660) 3RT19 36-1T . , Electrical and Additional Measurements 3RN1 Thermistor Motor Protection 3TK28 Safety Relays SIMOCODE 3UF , 3RN1 Thermistor Motor Protection 3TK28 Safety Relays 3 Explanations General information
Siemens
Original
5611A B siemens softstarter wiring diagram 3RW40 3TF6 1KB4 3RP15 05-1AP30 H-1/187

E251-230

Abstract: abb timer stt 11 opening: rated voltage: 1.25 In; 1.1 Un;, cos = 0.6 to DIN VDE 0632, AC 22 to VDE 0660 Part 107, IEC , 240: AC 21 A to VDE 0660 Part 107, DIN EN 60 947-3 and IEC 947-3 E 270: AC 22 A to VDE 0660 Part 107 , . 51 3 M orp metsyS Schalter 16, 25 and 32 A Series E 220 DIN EN 60 669-1, VDE , sleeve or pin-end connector according to DIN VDE 0113 250/400 V Special features safe connection , against electric shock according to DIN VDE 0106 Part 100 (BGV A2) Terminal assignment SK 0170 Z 91
ABB Stotz-Kontakt
Original
E251-230 abb timer stt 11 abb timer stt 17 s ABB STT 111 E 234-mfr E252-230 S0002 D-69006

calculation of line diSTANCE relay REL 670

Abstract: siemens EN 60947 VDE 0660 IEC 947 . 2/ 65 Thermistor motor protection relays , Measuring and monitoring relays CM and C5xx range Monitoring features and application ranges Thermistor motor protection Thermistor motor protection ½ Protection of motors against thermal overload, e , VDE V 0126-1-1 ½ ENEL DK 5940 Ed. 2.2 Marks a CE ½ ½ ½ ½ ½ ½ ½ ½ , ½ L RMRS ½ Marks C-Tick ½ ½ Thermistor motor protection
-
Original
calculation of line diSTANCE relay REL 670 siemens EN 60947 VDE 0660 IEC 947 Siemens KTY 84 PTC UMC100-FBP pt1000 thermistor curve 1svr450071r0000 R5000 R5100 R5200 R5300 R5400 R1000

100-FPT

Abstract: 100-SB01 VDE 0660, EN 60 947, UL 508, UL 1053 CE, C-tick, cUL, ATEX (pending) Cat. No. 193-EC_H 8.63 kg , GROUND FAULT SENSOR INPUT PTC THERMISTOR INPUT DEVICELOGIX (SERIES B) Cat. No. 9.5000 , Voltage (between control and load circuit) per DIN, VDE 0106, Part 101 (NAMUR recommendation) Contact , (with wires installed) Finger Protection Safe from touch by fingers and back-of-hand per VDE 0106 , , Continued Power Supply Ratings Thermistor/PTC Input Ratings, Continued 24V DC (supply via DeviceNet
Rockwell Automation
Original
100-FPT 100-SB01 100-SA11 100-SB11 100-FB11 100-DL420 193-EE 36-BP D-74834 300-SG001C-EN-P 300-SG001B-US-P
Showing first 20 results.