500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LTC2941IDCB#TRPBF Linear Technology LTC2941 - Battery Gas Gauge with I<sup>2</sup>C Interface; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2941CDCB#PBF Linear Technology LTC2941 - Battery Gas Gauge with I<sup>2</sup>C Interface; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2941IDCB#PBF Linear Technology LTC2941 - Battery Gas Gauge with I<sup>2</sup>C Interface; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2941CDCB#TRMPBF Linear Technology LTC2941 - Battery Gas Gauge with I<sup>2</sup>C Interface; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2941CDCB#TRPBF Linear Technology LTC2941 - Battery Gas Gauge with I<sup>2</sup>C Interface; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2941IDCB#TRMPBF Linear Technology LTC2941 - Battery Gas Gauge with I<sup>2</sup>C Interface; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy

strain gauge sensor interface

Catalog Datasheet MFG & Type PDF Document Tags

smd transistor f24 sot23

Abstract: LED backlight schematic laptop keyboard and mouse encoder which offers a programmable keyboard matrix and a PixiPoint® strain gauge sensor interface. It is a USB 2.0 full-speed device. The SH2165 is ideal for industrial applications , various strain gauge pointing device sensors. Typically consuming about 10 mA, the SH2165 PixiKey is , sensor that has four strain gauges ­ one on each of the sides. If force is applied precisely in the X , algorithm provides accurate cursor control · Provides built-in profiles to interface popular force-stick
Semtech
Original
smd transistor f24 sot23 LED backlight schematic laptop elantech touch smd transistor 5d sot-23 EVQ-QS205K strain gauge n6

strain gauge sensor interface

Abstract: CTS109 keyboard and mouse encoder which offers a programmable keyboard matrix and a PixiPoint® strain gauge sensor interface. It is a USB 2.0 full-speed device. The SH2165 is ideal for industrial applications , various strain gauge pointing device sensors. Typically consuming about 10 mA, the SH2165 PixiKey is , sensor that has four strain gauges ­ one on each of the sides. If force is applied precisely in the X , algorithm provides accurate cursor control · Provides built-in profiles to interface popular force-stick
Semtech
Original
strain gauge sensor interface CTS109 intel 3301 ROM led emergency fujitsu keyboard N860 N860-7401-T001

strain gauge

Abstract: strain gauge sensor microcontroller PRECISION ANALOG COOKBOOK â"¢ SENSOR SOLUTIONS Strain Gauge DAQ on a USB Stick Reference , port and monitor the voltage resulting from a bridge strain gauge through the GUI interface on a computer. Figure 1 shows the Data Acquisition on a Stick Strain Gauge reference design. Key Components , PRECISION ANALOG COOKBOOK SENSOR SOLUTIONS Strain Gauge DAQ on a USB Stick Reference Design with Renesas , R5F10JBC INDEX FIGURE 4. ISLRE-BDGSTKEV2Z EVALUATION BOARD SCHEMATIC Sensor: Foil strain gauge
Intersil
Original
strain gauge strain gauge sensor microcontroller ISL28134 ISL26102 ISL21010 ISL43741 ISL22316 NT/2000/XP/V
Abstract: PRECISION ANALOG COOKBOOK â"¢ SENSOR SOLUTIONS Strain Gauge DAQ on a USB Stick Reference , the USB port and monitor the voltage resulting from a bridge strain gauge through the GUI interface on a computer. Figure 1 shows the Data Acquisition on a Stick Strain Gauge reference design. Key , SENSOR SOLUTIONS Strain Gauge DAQ on a USB Stick Reference Design with Energy Micro EFM32 MCU , INDEX FIGURE 4. ISLEM-BDGSTKEV1Z EVALUATION BOARD SCHEMATIC Sensor: Foil strain gauge, bridge Intersil
Original
EFM32LG332F128 AN1820 FN6957 FN7896 FN7608 FN6186

strain gauge amplifier schematic

Abstract: PRECISION ANALOG COOKBOOK â"¢ SENSOR SOLUTIONS Strain Gauge DAQ on a USB Stick with , readings from a bridge strain gauge or a user supplied sensor. Figure 1 shows the Data Acquisition (DAQ) on a Stick connected to an external foil strain gauge. Key Components ISL28634 ISL28233 , COOKBOOK SENSOR SOLUTIONS Strain Gauge DAQ on a USB Stick with Programmable Gain INAMP with Renesas , ON A STICK WITH STRAIN GAUGE Figure 2 shows a simplified schematic of the Strain Gauge design
Intersil
Original
strain gauge amplifier schematic ISL26104 RL78/G1C ST-097

OP AMP COOKBOOK

Abstract: cookbook : Pressure / Strain Gauge Bridge Sensor Solution for Low Voltage Gain, Difference Signal Feed Straight into , SENSOR SOLUTIONS Various Solutions for Bridge Sensor Frontends: Pressure, Strain Gauge ISL28417 (4 of 4 , Frontends: Pressure, Strain Gauge INTRODUCTION FOIL STRAIN GAUGE Key Components Below are some , Gauge Sensor Analog Frontends Various System Partition Approaches For Bridge Sensor Figure 1 , ISL21090 ISL21009 5V +5V - +15V VREF + Strain Gauge 3k - 6kOhm Dual Supply to
Intersil
Original
OP AMP COOKBOOK cookbook ISL28133 ISL26132 ISL28617 EL8170/EL8173 ISL80111 ISL80112

strain gauge

Abstract: PRECISION ANALOG COOKBOOK â"¢ SENSOR SOLUTIONS VPG Low Voltage Strain Gauge DAQ on a USB , strain gauge design is a bridge solution that is able to extract a small sensor signal from a common , www.intersil.com 1 PRECISION ANALOG COOKBOOK SENSOR SOLUTIONS VPG Low Voltage Strain Gauge DAQ on a USB , ,Vishay Foil Resistors: http://www.vishaypg.com/docs/49787/intro.pdf Sensor: Foil strain gauge, bridge , , low noise and low power Micro-Measurements (MM) strain gauge reference design. The strain gauge
Intersil
Original
FN6053 ST-095
Abstract: . The strain gauge design is a bridge solution that is able to extract a small sensor signal from a , Application Note 1840 Author: Don LaFontaine Intersil, Renesas and VPG Low Voltage Strain Gauge , power Micro-Measurements (MM) strain gauge reference design. The strain gauge reference design is a precision solution from the sensor to the digital Graphical User Interface (GUI). The design uses Intersilâ , in Figure 1. The first board is the VPG strain gauge calibration box. The calibration box is a 1/2 Intersil
Original
ISL22316U ISL28134FHZ TSSOP24 ISL26102AVZ IP4220CZ6 AN1840

MPX100GVP

Abstract: Motorola MPX100A 's single element strain gauge design. Features · · · · · · · Low Cost Patented, Silicon Shear Stress Strain , pressure (P1) side. The output voltage of the differential or gauge sensor increases with increasing , transverse voltage diffused semiconduc tor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to differ ences in the thermal expansion of the strain gauge
-
OCR Scan
MPX100GVP Motorola MPX100A pressure sensor strain gauge pressure transducer MPX100A motorola gauge pressure sensor STRAIN GAUGE motorola MPX100 344C-01 MPX100D MPX100DP MPX100AP MPX100GP

MPX200a application

Abstract: STRAIN GAUGE simplified because of the predictability of Motorola's single element strain gauge design. Features Low Cost Patented Silicon Shear Stress Strain Gauge ±0.25% (max) Linearity Full Scale Span 60 mV (Typ) Easy to Use , transverse voltage diffused sem iconduc tor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon , gauge and the diaphragm, as are often encountered In bonded strain gauge pressure sensors. How ever, the
-
OCR Scan
MPX200 MPX200A MPX200a application silicon sensor strain gauge displacement sensor strain gauge MPX200D MPX200DP MPX200AP MPX200GP MPX200GVP

water level mpx5050

Abstract: bio-medical temperature sensor its patented strain gauge design. Unlike the more conventional pressure sensors which utilize four , element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. Applying pressure to the diaphragm results in a resistance change in the strain gauge, which in turn causes a change in the o u tpu t vo lta g e in d ire c t p ro p o rtio n to the a pplied pressure. The strain gauge is an , thermal expansion of the strain gauge and the diaphragm. The output parameters of the strain gauge itself
-
OCR Scan
water level mpx5050 bio-medical temperature sensor mpx7000 MPX 1,45 psi MPX5050 series pressure sensors biomedical pressure sensor MPX10 MPX50 MPX700 MPX906 MPX2010 MPXT2010G

displacement sensor strain gauge

Abstract: predictability of Motorola's single element strain gauge design. Features · · · · · · Low Cost Patented Silicon Shear Stress Strain Gauge Design ±1.0% (Max) Linearity (MPX1OD) Ratiometrlc to Supply Voltage Easy to , voltage of the differential or gauge sensor increases with increasing pressure applied to the pressure , semiconduc tor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no
-
OCR Scan
MPX12 MPX10D MPX10DP MPX10GP MPX10GVP MPX10GVS

STRAIN GAUGE motorola

Abstract: 's single element strain gauge design. MPX10 SERIES O tolO kPa (0-1.45 psi) 35 mV FULL SCALE SPAN (TYPICAL) Features · · · · · Low Cost Patented Silicon Shear Stress Strain Gauge Design Ratiometric to , voltage of the differential or gauge sensor increases w ith increasing pressure applied to the pressure , applied to the device. This de vice uses a unique transverse voltage diffused semiconduc tor strain gauge , this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to
-
OCR Scan
MPX10GS MPX10GSX 344B-01 344D-01 344E-01 344F-01

MPX50

Abstract: MPX20 . Compensation techniques are simplified because of the predictability of Motorola's single element strain gauge design. Features · Low Cost · Patented Silicon Shear Stress Strain Gauge Design · Ratiometric to Supply , differential pressure applied. The output voltage of the differential or gauge sensor increases with increasing , transverse voltage diffused semiconductor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon
Motorola
Original
MPX20 MPX50/MC STRAIN GAUGE silicon PPXV50GC7U PPXV50GC6U PPXV50G MPX50D MPX50DP MPX50GP

MPX200DP application notes

Abstract: MPX200 circuit 's single element strain gauge design. Features · Low Cost · Patented Silicon Shear Stress Strain Gauge · ± , , is drawn on the pressure (P1) side. The output voltage of the differential or gauge sensor increases , semiconductor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to differences in the thermal expansion of the strain gauge and the diaphragm, as are often
Motorola
Original
MPX200DP application notes MPX200 circuit

displacement sensor strain gauge

Abstract: predictability of Motorola's single elem ent strain gauge design. MPX10 MPX12 SERIES X-ducerTM SILICON PRESSURE SENSORS Features Low Cost Patented Silicon Shear Stress Strain Gauge Design ±1.0% (Max , strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no tem perature effects due to differ ences in the thermal expansion of the strain gauge and the diaphragm, as are often
-
OCR Scan
MPX10GVSX MPX12D MPX12DP MPX12GP MPX12GVP MPX12GS

strain gauge water level sensor

Abstract: automotive oil pressure electronic sensor in the strain gauge, which in turn causes a change in the output voltage in direct proportion to the applied pressure. The strain gauge is an integral part of the silicon diaphragm, hence there are no temperature effects due to differences in thermal expansion of the strain gauge and the diaphragm. The output parameters of the strain gauge itself are temperature dependent, however, requiring that the device be , element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. ACTIVE ELEMENT
Freescale Semiconductor
Original
strain gauge water level sensor automotive oil pressure electronic sensor infusion pump pressure transducer freescale tire pressure sensor industrial pressure sensor circuit oil pressure sensor

UL2157

Abstract: the predictability of Motorola's single element strain gauge design. It is designed for applications , 1 Features · · · · · Low Cost Patented Silicon Shear Stress Strain Gauge Design Ratiometric to , tor strain gauge which Is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to differ ences In the thermal expansion of the strain gauge and the diaphragm, as are often
-
OCR Scan
UL2157 MPX906D PX906 867H-03 MPX906GVW
Abstract: 's single element strain gauge design. MPX12 SERIES 0 to 10 kPa (0-1.45 psi) 35 mV FULL SCALE SPAN (TYPICAL) Features · · · · · Low Cost Patented Silicon Shear Stress Strain Gauge Design Ratiometric to , semiconduc tor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to differ ences in the thermal expansion of the strain gauge and the diaphragm, as are -
OCR Scan
MPX12GSX

Motorola MPX100

Abstract: Motorola MPX100A 's single element strain gauge design. Features · Low Cost · Patented, Silicon Shear Stress Strain Gauge , ambient, is drawn on the pressure (P1) side. The output voltage of the differential or gauge sensor , diffused semiconductor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure. Because this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to differences in the thermal expansion of the strain gauge and the
Motorola
Original
Motorola MPX100 MPX100 Application notes Motorola MPX100A Pressure Sensor MPX100A Pressure Sensor MPX100 application note MPX100A MPX100AS MPX100ASX MPX100GS MPX100GSX
Showing first 20 results.