500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
MOTIONFIRE-MOTORCONTROL-REF Texas Instruments Motionfire Motor Control Reference Design (FireDriver Module)
COMBOMOTOR Texas Instruments AMC1200 4kV peak Isolated Amplifier for Current Shunt Measurements

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : .1251X1 DP SS PREC.SLIPF1T Supplier : PINS Manufacturer : Bisco Industries Stock : 88 Best Price : - Price Each : -
Shipping cost not included. Currency conversions are estimated. 

slip ring motor characteristics curve

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: slip ring motor is that slip rings and brush assemblies need regular maintenance, which is a cost not , characteristics of these motors. This application note discusses the basics of an AC induction motor; the , torque-speed curve. A modified version of the capacitor start motor is the resistance start motor. In this , torque-speed curve. The PSC motors have several advantages. The motor design can easily be altered for use , replace than to repair. FIGURE 8: TYPICAL SHADED-POLE INDUCTION MOTOR Copper Ring Input Power Microchip Technology
Original
AN887 capacitor start induction motor fan motor winding formula wiring diagram slip ring motor vfd circuit diagram for motor wiring diagram motor start delta DS00887A- 11F-3 DK-2750 D-85737 NL-5152
Abstract: shaft to connect the rings. So, in normal conditions, the slip ring motor functions like a squirrel , speed-torque characteristics of an induction motor. The X axis shows speed and slip. The Y axis shows the , . Synchronous speed of an induction motor is shown in Equation 1. Note 1: Percentage of slip varies with load on the motor shaft. 2: As the load increases, the slip also increases. INDUCTION MOTOR TYPES , categories: squirrel cage motors and slip ring motors. The stator construction is the same in both motors Microchip Technology
Original
AN843 schematic diagram induction heating PIC16C738 ir21362_DIP28 slip ring motor an843, pic18 PIC18 D-81739 DS00843A-
Abstract: Series, but must be connected on the supply side, NOT on the motor. 5.9.2 Slip ring motors Slip ring , resistor value must be carefully selected to suit motor and load characteristics. 5.9.3 Parallel motors Use , MTE Ltd (Electronic Motor Controllers 4kW to 37kW) RS stock numbers 279-4230, 279-4246, 279-4252 , motor is fully controlled during the starting sequence to achieve a smooth increase in motor voltage , used with any 3phase induction motor up to the specified maximum rating. PowerSoft MN is available in -
Original
37 MTE powersoft 24v dc soft start motor control diagram BS4265 how to install wiring DOL starter wiring diagram slip ring motor 415V AC wiring diagram STAR DELTA motor starter
Abstract: continued 5.9.2 Slip ring motors 6. Index Braking Bypass contactor Control Board Control , ,8 9 6 7 10 9 3,4,6 10 4,8 3 3,4,7 9 5 3,4,6 6 10 Slip ring (wound rotor) m otors can be used to , on soft starter assem blies. Slip ring motors Soft Stop Specifications Starting profile Supply , POWERSOFT MN SERIES ELECTRONIC MOTOR CONTROLLERS 4kW to 37kW TECHNICAL MANUAL 1E February 1997 , the starting sequence to achieve a sm ooth increase in motor voltage, torque and speed; current lim it -
OCR Scan
fuse 9 BJE 69 testing soft starter 37 MTE soft starter AC 240V Motor Speed Controller hp 15 star delta control 3phase 3 phase motor soft starter diagram
Abstract: setting, troubleshooting, and daily maintenance of the AC motor drive. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drive. Keep this , equipment, only qualified personnel familiar with AC motor drive are to do installation, start-up and maintenance. Always read this manual thoroughly before using VFD-G series AC Motor Drive, especially the , . DANGER! 1. 2. AC input power must be disconnected before any wiring to the AC motor drive is made -
Original
vfd B DELTA 7.5kw 10hp vfd-pu01 inverter Delta 132 kw three phase VFD110F43A-G 30KW VFD Diagram VFD1100F43C-G 50/60H
Abstract: setting, troubleshooting, and daily maintenance of the AC motor drives. To guarantee safe operation of , read this manual thoroughly before using VFD-F series AC Motor Drives. Ensure that VFD-F is grounded , regulation.) ! CAUTION! The rated voltage for the AC motor drive must be 240V for 230V models ( 480V , 3-14 3.7 Motor Operation Precautions . , and Motor Parameters . 5-36 5.9 Group 8: Special Parameters -
Original
VFD150F43A VFD110F43A of delta vfd-f VFD150* user manual vfd S1 DELTA VFDB4030 VFD1100F43C VFD1100F43H VFD1320F43A VFD1320F43H VFD1600F43A VFD1600F43H
Abstract: connections eliminates sparks from the brush/slip ring contact, providing safety for those applications that , OEM Part Numbers 26 Electrical Specification and Selection Guide Rotor and Slip Ring , Dimensions Brushless Construction: Stationary Field Coil No Brushes or Slip Rings 7.795 in 198.0 mm Delco Remy
Original
Bosch alternator diode DIODE E1210 bosch alternator 12V alternator delco remy AUTO DIODE E1210 relay kt-450
Abstract: . Frequency Pr.15 > d0001 "S curve Enabled" Time S-curve characteristics Time S-curve characteristics Time Pr.15 = d0000 "S curve Disabled" Time Accel Time 1 or 2 Decel Time 1 or 2 , 1 Introduction Congratulations on your purchase of the DELTA VFD-A series AC motor drive. The VFD series is a high-performance / low noise general-purpose AC motor drive, manufactured using high-quality , reference. ! Warning! To avoid personal injury, do not remove the cover of the AC motor drive until all Delta Electronics
Original
VFD007A21A VFD007A23A VFD015A21A VFD015A43B VFD185A43A VFD037A43A TRANSISTOR D400 delta vfd-a user manual transistor D400 diagram OF D400 transistor 3000w inverter circuit diagram VFD075A23B VFD007A43A VFD075A43B
Abstract: maintenance of the AC motor drive. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drive. Keep this operating manual at hand and distribute , personnel familiar with AC motor drive are to do installation, start-up and maintenance. Always read this manual thoroughly before using VFD-VE series AC Motor Drive, especially the WARNING, DANGER and CAUTION , power must be disconnected before any wiring to the AC motor drive is made. A charge may still remain -
Original
transistor MRC 100-6 3000w audio amplifier delta 5.5KW frequency inverter 380 volt VFD037V43A-2 car power amp circuit diagrams 1000w 3000w dc to ac inverter Circuit diagram
Abstract: Motion Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 Slip Ring Assemblies . . Aeroflex Colorado Springs
Original
UT16AD40P EM-553 motor BUS-8553 CD4583 spw 068 power supply spw 068 RS485
Abstract: RMS On-State Current Amps Derating Curve (50 & 75 amp) 80 75A 60 On 50A 40 On he , Derating Curve (50 & 75 amp) 80 75A 60 40 On 50A On he ats ink hea 20 (1 , On-State Current Amps Derating Curve (50 & 75 Amp) 80 75A 60 On 50A 40 On he ats , Curve (50 & 75 Amp) 80 75A 60 40 On 50A On he ats ink hea 20 Safety , DIN-Rail Mount Relay, 4-32V DC Control, 660VAC Max. Output RMS On-State Current Amps Derating Curve (25 Sprecher + Schuh
Original
SAR6-50-1 SAR6-75-1 Sprecher Schuh SAR6-30-3D normal SLIP led 3 volt 5 leg relay free 50-1D SAS6-75-1D SAR6-25-1D SAR6-40-1D SAS3-50-1 SAS3-75-1
Abstract: wye-connected induction motor 1 NOTE: PULSE RA TING CURVE FOR 1,240 us PULSE WIDTH 104 105 106 , circuit placement. 8. Energy at start, i.e., SLIP = 1. 9. Induction motor. 10. 2, and 4 pole motors , AMPERES 8/20us WAVESHAPE Figure 2a. V130LA Varistor V-I Characteristics 1000 800 600 MAXIMUM PEAK , Characteristics Figure 1a. Transient Generator 100 H 0.1 F D + 150 F - Figure 1b. Typical , CI 0.2uF FIGURE 4 SCR MOTOR CONTROL Figure 4. SCR Motor Control Solution Add a varistor to Littelfuse
Original
EC638 15J 6KV SCR C106D equivalent circuit VARISTOR 275 LA 20A 5 hp DC motor speed control using scr transformer with 20kVA rating 117VAC V130LA2 V130LA5 V130LA10A V130LA20A UL1449
Abstract: wiring to the AC motor drive is made. DANGER Even if the power has been turned off, a charge may , internal components or wiring. Ground the AC motor drive using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed. DO NOT install the AC motor drive in a place subjected to high temperature, direct sunlight and inflammables. Never connect the AC motor drive output terminals U/T1, V/T2 and W/T3 CAU TION directly to the AC Delta Electronics
Original
transistor D2058 K D2058 Y transistor D2041 D2058 transistor transistor K D2059 D2061 transistor M1067 M1066 C2000
Abstract: Busbar applications 20 Transformer applications 22 Motor applications 28 Generator , selection guide proposes the Sepam types suited to your protection needs, based on the characteristics of , breaker failure Busbar P. 20 Transformer P. 22 S20 S24 B21 A B N Motor P. 28 , Applications Substation P. 18 b B22 T24 M20 Characteristics Inputs 4 0 0 0 to , Transformer P. 22 Motor P. 28 Generator P. 32 Capacitor P. 36 (5) S41 S51 (5) T40 T50 Schneider Electric
Original
ANSI 87T Magnetic Sensor 81l telemecanique timer catalogue SDK303 SDK313 SDK383 SDK888 SDK000 SEPED303005EN
Abstract: 8/20us WAVESHAPE FIGURE 2A. FIGURE 2B. FIGURE 2. V130LA VARISTOR V-I CHARACTERISTICS 27 , t 10us FIGURE 3A. 20us FIGURE 3B. FIGURE 3. ENERGY APPROXIMATION SCR Motor Control , FIGURE 4. SCR MOTOR CONTROL 10-128 Determine the peak suppressed transient voltage produced by the , which have maximum steady-state DC voltage ratings of 31V. The V39MA2B and V39ZA05 V-I characteristics , set up with lumped elements replacing the measured circuit values. The motor impedance was simulated Littelfuse
Original
welding transformer SCR scr tic 106 200mh inductor scr C106 Fuse class CC 400V crowbar SCR C106D terminal and characteristic
Abstract: MOTOR (hp) 400 600 800 1000 NOTES: 1. Y connected 60Hz. 2. Energy at max torque slip speed. 3. See , . Energy at start, i.e., SLIP = 1. 9. Induction motor. 10. 2, and 4 pole motors. FIGURE 19. STORED ENERGY , CHARACTERISTICS FIGURE 2B. IV VARISTOR CURRENT VARISTOR CURRENT 27 IV 27 t 10us 20us APPR OXIM ATIO N t 10us 20us FIGURE 3A. FIGURE 3. ENERGY APPROXIMATION FIGURE 3B. SCR Motor , FIELD 480V AC 60Hz R3 250k SUS 4:1 R2 15k CI 0.2uF SCR FIGURE 4. SCR MOTOR CONTROL 11-136 Harris Semiconductor
Original
AN9772 UL1499 harris varistor 20kVA transformer HIIAA ISO9000 1-800-4-HARRIS
Abstract: . 38 Motor Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aeroflex Colorado Springs
Original
5962-94758 5962-1320101KXC RTAX2000 GR712RC Metelics 2006 catalog RHD5932
Abstract: induction motor is the squirrel cage motor. The wires along the rotor axis are connected by a metal ring at , rotor frequency is called slip frequency (slip = e - r). An asynchronous motor There are several , inverter, independently from the line voltage and the motor characteristics. 5.4 Maximum DC bus voltage , Digital Signal Processing Solution for AC Induction motor Application Note IMPORTANT NOTICE , solution to control an AC induction motor using the TMS320C24x. This new family of DSP controllers enables Texas Instruments
Original
3 phase to d-q transformation scalar control of induction motor 3 phase inverters ac induction motor DSP based sinewave inverter squirrel cage induction generator Luenberger Observers TMS320C240 TMS320F240
Abstract: . 38 Motor Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aeroflex Microelectronic Solutions
Original
Abstract: squirrel cage motor. The wires along the rotor axis are connected by a metal ring at the ends resulting in , (slip = e - r). An Asynchronous Motor There are several ways to control an induction motor in torque , on Frequency method is based on steady-state characteristics of the motor and the assumption that , inverter. · The reference current equation depends on the motor electrical characteristics, and it's also , , independently from the line voltage and the motor characteristics. 5.4 Maximum DC Bus Voltage of the Texas Instruments
Original
kalman filter using fuzzy logic estimation with extended kalman filter slip ring induction motor Luenberger extended Luenberger Luenberger observer induction motor BPRA043
Showing first 20 results.