500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT5528EUF#3BTPBF Linear Technology 1.5GHz to 2.4GHz High Linearity Direct Quadrature Modulator visit Linear Technology - Now Part of Analog Devices
LT5528EUF#3BTTRPBF Linear Technology 1.5GHz to 2.4GHz High Linearity Direct Quadrature Modulator visit Linear Technology - Now Part of Analog Devices
LTC3026IMSE-1#TRPBF Linear Technology LTC3026-1 - 1.5A Low Input Voltage VLDO Linear Regulator; Package: MSOP; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC3026EDD-1#PBF Linear Technology LTC3026-1 - 1.5A Low Input Voltage VLDO Linear Regulator; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT1965IDD-1.5#PBF Linear Technology LT1965 - 1.1A, Low Noise, Low Dropout Linear Regulator; Package: DFN; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT1965EQ-2.5#TRPBF Linear Technology LT1965 - 1.1A, Low Noise, Low Dropout Linear Regulator; Package: DD PAK; Pins: 5; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy

slide linear potentiometer pt100

Catalog Datasheet MFG & Type PDF Document Tags

LR42272

Abstract: Q415 Input, Three-Wire Transmitter Provides Two DC Outputs in Proportion toTwo Pt100 RTD Temperature , Optional I/QRail Power Bus Connector Saves Installation Time n Output Linear to Input Temperature , transmitters. Each channel accepts an RTD input and provides a DC output signal linear to the RTD temperature , - To-Repair (MTTR). If desired, two or more modules can slide together and interlock for solid, high density , side or left side mounting, respectively. The module to be attached will easily slide on to the side
Eurotherm Action
Original

LR42272

Abstract: WV905 Outputs in Proportion to the PT100 RTD Inputs Description Benefits Up to 4 Two-Wire Transmitters in , powered 4-20mA signal, linear to the temperature input. Each channel is an independent transmitter with , easy installation and low MeanTime-To-Repair (MTTR). Two or more modules can slide together and , right-hand side or lefthand hand side mounting, respectively). The module to be attached will easily slide on to the side of the mounted unit. SnapLocTM Plug-in Terminals Application Output Linear to
-
Original
WV905 LR42272 current simulator 4-20mA Barber-Colman rtd circuit rtd pt100 datasheet 600VDC 24VDC 741-F 721-0562-00-H

PT100 IEC 751

Abstract: en60751 transmitter that accepts most commonly used temperature sensors, slide wire transducers or millivolt signals , . 2.0 SPECIFICATION @ 24 ºC 2.1 RTD INPUT (Pt100) Sensor Range Minimum Span*¹ Linearisation , (-10 to 75) mV Linear. Custom[X]*³, 4th order polynomial 5 mV ± 10 µV ± 0.07 % RDG 10 M 0.1 µV/ºC , Measurement Accuracy*² Temperature Drift 3 wire potentiometer (10 to 390) (End to End). For input with R > 390 terminals 9 and 10 have to be linked. Linear. Custom [X]*³, 4th order polynomial 5 % of full
Status Instruments
Original
BS1904 PT100 IEC 751 en60751 slide linear potentiometer pt100 PT100 temperature sensor data sheet PT100 Thermocouple Amplifier transducer 61326 SEM215 EN60751

IEC 584-3

Abstract: PT100 standard IEC 60751 accuracy most commonly used temperature sensors, slide wire transducers or millivolt signals and transmits them , Full Range Input 2.0 SPECIFICATION @ 24ºC 2.11 RTD Input (Pt100) -200 to +850ºC (18 to 390 ) 25ºC , -10 to +75 mV Characterisation Linear. Custom [X]3, 4th order polynomial Minimum Span¹ 5 mV Basic , / ºC 3 Wire potentiometer 10 to 390 (End to End) For input with R > 390 terminals 9 and 10 have to be linked. Characterisation Linear. Custom [X] 3, 4th order polynomial Minimum Span1 5% of
-
Original
IEC 584-3 PT100 standard IEC 60751 accuracy 60584-2 4-20mA circuit 43670 BS 4937

UTI 18L

Abstract: pt100 sensor interface with microcontroller pF, 0 -12 pF, variable range up to 300 pF Platinum resistors Pt100, Pt1000 Thermistors 1 k - 25 k , capacitors varialble range ( , ,5 mV) 1 3 potentiometer 1 - 50 k Table 2, Modes of UTI last update November 30, 2010 , unknown gain in a linear system. In order to apply this technique, in addition to the measurement of the
Smartec
Original
UTI 18L pt100 sensor interface with microcontroller rx3e 25E03 PT100 bridge pt100 interface current source multiplexer SOIC-18L

E5EK-AA2-500

Abstract: E5AK omron cover Note: 1. When using the heater burnout alarm function with a standard model, the Linear Output , ) 24 VDC E53-Q4 Pulse (PNP) 24 VDC E53-C3 . Linear (4 to 20 mA) E53-C3D . Linear (0 to 20 mA) E53-V34 - Unear (4 to 10 V) E53-V35 - Linear (0 to 5 V) Note: The Digital Controller uses a dedicated , ) JR100 Pt100 Range °C -199.9 to 650.0 -199.9 to 650.0 °F -199.9 to 999.9 -199.9 to 999.9 Resolution , resistance thermometer: JPH00, Pt100 Current input: 4 to 20 mA, 0 to 20 mA (Input impedance: 150 Q) Voltage
-
OCR Scan
E5AK-AA2-500 E5AK-PRR2-500 E5EK-AA2-500 E5EK-PRR2-500 E53-R E53-S E5AK omron E53-Q3 relay 12vdc 3f omron E53-R IP66/NEMA4 RS-232C RS-422 RS-485

PT100 bridge

Abstract: PT1000 thermistor . When only a single potentiometer is measured with its slide connected to, for instance, node B, nodes , -12 pF, variable range up to 300 pF · Platinum resistors Pt100, Pt1000 · Thermistors 1 k - 25 k · , unknown offset and unknown gain in a linear system. In order to apply this technique, in addition to the , . Suppose a system has a linear transfer function of M i = kE i + M off . Then the measuring result is the ratio M= M x - M off M ref - M off = Ex . E ref (3) When the system is linear
Smartec
Original
PT1000 thermistor pt100 multiplexer PT1000 table Pt100 3 wire PT1000 temperature sensor PT100 bridge example

rtd 2668

Abstract: power amplifier 3000W with PCB up and timed temperature soak Ì Selectable inputs, thermocouple, RTD/PT100 and linear process Ì Dual , 9 thermocouples, RTD/PT100 and linear process Zero and span adjustment for on site calibration , thermocouple types, the PT100 resistance thermometer and linear 4-20mA. Two outputs are provided, a logic , ,T,L,N,R,S,B, Planitell II, 2 wire PT100 Linear 0-20mA, 0-80mV °C or °F or Kelvin The greater of ± , E6C0SRR02 20 to 48V ac ac E6C0SRR22 Relay, Relay & Linear DC - Outputs 1, 2 & 3 100 to 240V ac ac E6C0SSR02
Element14 Catalog
Original
rtd 2668 power amplifier 3000W with PCB ZENER h48 IR32Z relay 3500 2231 021 MTL5018 DM3600U/S1 DM3600U/S2

E5EK-AA2-500

Abstract: E5AK-AA2-500 USER MANUAL terminal cover 1. When using the heater burnout alarm function with a standard model, the Linear Output , Pulse (PNP) 24 VDC E53-C3 Linear (4 to 20 mA) E53-C3D Linear (0 to 20 mA) E53-V34 Linear (0 to 10 V) E53-V35 Note: Relay E53-Q Unit E53-R E53-S Output Linear (0 to , Ranges Platinum Resistance Input (switch Thermometer selectable) JPt100 Pt100 199.9 , thermometer: JPt100, Pt100 Current input: 4 to 20 mA, 0 to 20 mA (Input impedance: 150 W) Voltage input: 1
OMRON
Original
E5AK-AA2-500 USER MANUAL E5CK THERMOCOUPLE PT100 J TYPE OR K TYPE H84-E1-2 1196-1M

E5AK-AA2-500 USER MANUAL

Abstract: circuit diagram of pid controller alarm function with a standard model, the Linear Output Unit cannot be used for the control outputs , (PNP) 24 VDC E53-C3 Linear (4 to 20 mA) E53-C3D Linear (0 to 20 mA) E53-V34 Linear (0 to 10 V) E53-V35 Note: Relay E53-S Output Unit Linear (0 to 5 V) The Digital , ) JPt100 !C Range Pt100 -199.9 to 650.0 !F -199.9 to 650.0 -199.9 to 999.9 , resistance thermometer: JPt100, Pt100 Current input: 4 to 20 mA, 0 to 20 mA (Input impedance: 150 "
OMRON
Original
circuit diagram of pid controller ct3-12 E5AK-AA2 E5EK-PRR2 AC100-240 ct Potentiometer diagram 3 phase heater AC/DC24V AC100-240 AC/DC24 H084-E1-3 0397-2M

E5AK-AA2-500 USER MANUAL

Abstract: E5EK-PRR2-500 the heater burnout alarm function with a standard model, the Linear Output Unit cannot be used for the , Pulse (NPN) 24 VDC E53-Q4 Pulse (PNP) 24 VDC E53-C3 Linear (4 to 20 mA) E53-C3D Linear (0 to 20 mA) E53-V34 Linear (0 to 10 V) E53-V35 Note: E53-R Linear (0 to 5 V) The , ) JPt100 Pt100 °C ­199.9 to 650.0 ­199.9 to 650.0 °F ­199.9 to 999.9 ­199.9 to 999.9 , Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII Platinum resistance thermometer: JPt100, Pt100 Current
OMRON
Original
omron pid settings E5aK power ac PID controller for temperature control motor PT100 connected diagram RSP RELAY

tyn 277

Abstract: 256-TWM configuration i.e. Single Phase, 3 Phase 3 or 4 Wire, balanced or unbalanced load. 7. For slide wire , Connection Diag. 12 12 Slide Wire Transmitter Designed for accurate measurements and transmission of resistance ratio of a 3 wire potentiometer. A stabilised voltage is applied to the potentiometer and the , values of R1, R2, R3 Example for 1k Potentiometer: R1 = 1k, R2 = 0, R3 = 1k Example for 5k Potentiometer using only 4k; R1 = 5k, R2 = 1k, R3 = 4k (Remember R1 = R2 + R3) 0/1mA, 0/5mA, 0/10mA, 0/20mA or
-
Original
256-TPSU 256-TFAU tyn 277 256-TWM paladin 253-TAL 256-TWH 256-TWL 256-TPAU 256-TPTU 256-TPBU 256-TFSU 256-TFCU

E5CK-TAA1-500

Abstract: E5AK-TAA2-500 , the Linear Output Unit cannot be used for the control outputs (heat). 2. Be sure to specify the , . E53-C3 Linear (4 to 20 mA) under a load of 600 max. E53-C3D Linear (0 to 20 mA) under a load of 600 max. E53-V34 Linear (0 to 10 V) under a load of 1 k min. E53-V35 Note: E53-R Linear (0 to 5 V) under a load of 1 k min. The Digital Controller uses a dedicated, high-resolution , Y92S-L1 Ranges Platinum Resistance Thermometer Input (switch selectable) JPt100 Pt100 °C
OMRON
Original
E5CK-TAA1-500 E5AK-TAA2-500 E5AK-TAA2 AC100-240 E5AK-TPRR2 E5EK-TPRR2-500 E5AK-TPRR2-500 H087-E1-2 1098-2M

omron e5ck-aa1 302

Abstract: E5CK-AA1-302 E5CK-AA1-302 Note: 1. When using the heater burnout alarm function with a standard model, the Linear , to 20 mA E5CK 1 E53-C4DR4 Relay/Linear voltage SPST, 5 A/0 to 10 VDC E5CK 1 , 20 mA E5AK/E5EK 3/1 E53-AKF 4 to 20 mA E5CK 1 E53-CKF Linear current Linear voltage g Relay/Linear current y/ Computer communications p Event input p Transfer output p , Input (field selectable) Range g Pt100 °C -199.9 to 650.0 -199.9 to 650.0 °F
OMRON
Original
omron e5ck-aa1 302 E53-AK02 E5JK OMRON OMRON E5 X temperature controller E5CK-302 OMRON E5 IP66/NEMA E5CK-AA1-500 H301-E3-02

PT100 temperature sensor data sheet

Abstract: signal conditioning circuit for pt100 using the heater burnout alarm function with a standard model, the Linear Output Module cannot be used , E5CK 1 E53-C4R4 SPST, 5 A/0 to 20 mA E5CK 1 E53-C4DR4 Relay/Linear voltage SPST , E53-AK03 Linear current Linear voltage g Relay/Linear current y/ Computer communications p , , tungsten rhenium 26). Platinum Resistance Thermometer (RTD's) Input (field selectable) JPt100 Pt100 , Platinum resistance thermometer (RTD) JPt100, Pt100 Current input 4 to 20 mA, 0 to 20 mA
OMRON
Original
signal conditioning circuit for pt100 pt100 temperature sensor circuit diagram signal conditioning circuit for pt100 4-20 mA PT100 4 wire temperature sensor circuit diagram temperature measurement rtd PT100 temperature sensor datasheet H301-E3-1

703030

Abstract: PT100 temperature sensor JUMO manual 000 Heater current indication 0-50 mA AC 090 Stroke retransmission potentiometer 101 , into the panel cut-out. H From the back of the panel slide the mounting brackets into the guides at , through process value correction (OFFS) Potentiometer 211 S slider 212 E end 213 A start , 1. for setting Pt100 or standard signal with one decimal place. vSection 8.1 22 Influences , AC) Output retransmission (input: potentiometer) 4 External setpoint (input: 0-20mA/4-20mA
JUMO
Original
703030 PT100 temperature sensor JUMO manual modbus RS485 jumo jumo PT100 be100 K3298

PT100 temperature sensor data sheet

Abstract: e5ck-aa1-302 standard model, the Linear Output Module cannot be used for the control outputs (heat). The Digital , E53-C4R4 SPST, 5 A/0 to 20 mA E5CK 1 E53-C4DR4 Relay/Linear voltage SPST, 5 A/0 to 10 VDC , E53-CKB 4 to 20 mA E5AK/E5EK 3/1 E53-AKF 4 to 20 mA E5CK 1 E53-CKF Linear current Linear voltage Relay/Linear current Computer communications Computer communications , rhenium 5, tungsten rhenium 26). Platinum Resistance Thermometer (RTD's) JPt100 Pt100 °C ­199.9
OMRON
Original
OMRON plc programming manual fuzzy temperature controller C code TEMPERATURE CONTROLLER with pid E5AK omron software 24V 4.....20MA E5AK-PRR2 H79E33A 1-800-55-OMRON GCTC13

SENSOR HALL 946 s 452

Abstract: k30206 PTC-relay â'¢ increase resistance slowly by turning the potentiometer until the according alarm switches
ZIEHL industrie-elektronik
Original
SENSOR HALL 946 s 452 k30206 RCM1000V D-47055 D-74523

E5CK-AA1-302

Abstract: omron e5ck-aa1 302 burnout alarm function with a standard model, the Linear Output Module cannot be used for the control , E53-Q4 Linear (4 to 20 mA) E53-C3 Linear (0 to 20 mA) E53-C3D Linear (0 to 10 V) E53-V34 Linear (0 to 5 V) E53-V35 Note: 1. The Digital Controller uses a dedicated , Pulse (PNP)/Pulse (PNP) E53-Q4HQ4H Linear (4 to 20 mA)/Relay E53-C4R4 Linear (0 to 20 mA)/Relay E53-C4DR4 Linear (0 to 10 V)/Relay E53-V44R4 Note: If the control period is less than
-
Original
E53-R4R4 IP66/NEMA4X GCTC12

8 PIN RELAY 24V dc pla price list

Abstract: ). 10 Universal Input Connections â'" PT100 (RTD) input. 10 Universal Input Connections - Linear Volt, mV or mA input , . 11 Option Slot 1 - Linear Voltage or mADC Output module , . 12 Option Slot 2 - Linear Voltage or mADC Output module , . 12 Option Slot 3 - Linear Voltage or mADC Output module
Chromalox
Original
8 PIN RELAY 24V dc pla price list PK508 120/240V RS485
Showing first 20 results.