NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
RI-RFM-003B-00 Texas Instruments RI-RFM-003B-00 Series 2000 Mini Radio Frequency Module ri Buy
RI-ACC-008B-00 Texas Instruments RI-ACC-008B-00 Series 2000 High-Performance Remote Antenna RFM and Tuning Module ri Buy
PC-SOIC/DIP8-01 Ironwood Electronics SOIC to DIP Package Converters; Top Package Code: SO8A_S08B_SO8E; Bottom Package Code: 0.3; Top Pitch (mm): 1.27; Bottom Pitch (mm): 2.54; Top Pin Count: 8; Bottom Pin Count: 8; Top Array Size: N/A; Bottom Array Size: N/A; Top Interface: SOIC Land Pattern; Bottom Interface: Thru Hole Pins; Inside Land Dim. - Ouside land dim. (in.): 0.15 - 0.375; Adapter Size Length X Width (in.): 0.4 x 0.4; Part Description: SOIC to DIP Converter; ri Buy

size 00 fuse links

Catalog Datasheet Results Type PDF Document Tags
Abstract: LAST UPDATED:August 23, 2007 L675 PANEL FUSEHOLDER BARRIER & PANEL SEALED Design facilitates use for size 00 fuse links. This is a rugged fuseholder and was specially designed for Services use with heavy duty (high rupturing capacity) fuse links. It is not suitable for use with Glass cartridge fuse links CURRENT RATING: 2A (temperature rise to 40°C ) ° TEMPERATURE RANGE: -55°C to +70°C (ambient) BREAKDOWN VOLTAGE: 9kV (sea level) INSERTION RESISTANCE 5 milliohms (average ... Original
datasheet

1 pages,
152.35 Kb

L675 Dialight L675 size 00 fuse links datasheet abstract
datasheet frame
Abstract: LAST UPDATED: August 23, 2007 L575A L575A PANEL FUSEHOLDER Design facilitates use for size 00 fuse links. This is a miniature fuseholder recommended for all situations where space is at a premium. There is a test probe aperture in the lid. CURRENT RATING: 2.5A (temperature rise to ... Original
datasheet

1 pages,
153.67 Kb

L575A L575A abstract
datasheet frame
Abstract: LAST UPDATED: August 14, 2001 L575A L575A PANEL FUSEHOLDER Design facilitates use for size 00 fuse links. This is a miniature fuseholder recommended for all situations where space is at a premium. There is a test probe aperture in the lid. CURRENT RATING: 2.5A (temperature rise to ... Original
datasheet

1 pages,
34.79 Kb

l575 Humidity and Temperature Probe fuse 2.5a BLP Components 3.5KV Miniature fuse size 00 fuse links L575A L575A abstract
datasheet frame
Abstract: * Striker fuse links can operate a micro-switch for remote fuse link operated indication Dimensions - mm Fuse Links - with or without indicator Fuse Links with striker Size (mm) A B C D , Cylindrical Fuse Links for Industrial Applications Class gG/gL and aM, 0.16 to 125A, 400 to 690Vac , (C22M12I C22M12I) Refer to data sheet 2143 IEC 60269 Description: Cylindrical class gG-gL and aM fuse links are intended for industrial applications. Some industrial fuse links are available with an operated ... Original
datasheet

9 pages,
1147.79 Kb

C14G6 C14G Fuse Links C10G10 C14G4 C14G40 C14G4I size 00 fuse links 22x58 gg C22G100 C14G8 FUSE am 690 CYLINDRICAL FUSE C22M100 C08G C08G4 C10G4 C08G4 abstract
datasheet frame
Abstract: POWR-GARD® Fuse Datasheet NH Fuse links 500 Volts · 2-630 A Specifications Voltage Rating , All NH fuse links incorporate a blown fuse indicator Description Littelfuse ® European style NHfuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse , aM characteristic fuse links are used for the short-circuit protection of motors and switchgear. They , Littelfuse POWR-GARD® Products Rev: 013013 POWR-GARD® Fuse Datasheet NH Fuse links DIMENSIONS ... Original
datasheet

2 pages,
144.66 Kb

size 00 fuse links NH3 GL-GG NH3 fuse NH2 fuse aM IEC 269-2-1 FUSE am 690 FUSE base NH2 NH fuse 500 A NH3 fuse aM datasheet abstract
datasheet frame
Abstract: Dual Indication Fuse Links NH Class gG/gL, 690Vac, 63 to 315 Amps, Size 2 Size 2 Time-Current , 720109 NH DIN Dual Indication Fuse Links NH Class gG/gL, 690Vac, 250 to 500 Amps, Size 3 Size , NH DIN Dual Indication Fuse Links NH Class gG/gL, 690Vac, 2 to 500 Amps, Sizes 000 to 3 , fuse links for a wide variety of applications. Packaging All fuse links are packed in 3's , With metal gripping lugs: (amp)NHG(Size)B-690 B-690 Operation Class: gG/gL Fuse Holders Fuse bases: SB ... Original
datasheet

7 pages,
683.96 Kb

0647K 120KA 63NHG00B-690 125NHG00B-690 125NHG2B-690 size 00 fuse links 32NHG000B-690 IEC 60269-2 nhG fuse 6NHG000B-690 16NHG000B-690 fuse iec 60269 80NHG00B-690 10NHG000B-690 datasheet abstract
datasheet frame
Abstract: NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic fuse links are used for the short , , characteristic and amperage) Size 00C 00 0 1C 1 2C 2 3C 3 Current Range 2A up to 100A 2A up to , :1 25 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 All NH fuse links ... Original
datasheet

2 pages,
425.04 Kb

NH1G250 NH00CG6 size 00 fuse links A 7800 690V NH1M160 NH1G200 nh fuse NH2 GL-GG IEC 269-2-1 NH1CG25 NH00CG63 NH00G125 160A Fuse NH00C NH1CG25 NH00C abstract
datasheet frame
Abstract: 500NHM3B-690 500NHM3B-690 630NHM3B 630NHM3B 3 2 1 0 00 000 Fuse Size Amp Rating 6 10 16 20 25 32 35 40 50 63 80 100 160 6 10 16 20 32 , NH DIN Dual Indication Fuse Links Class aM, 500 & 690Vac, 6 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, DIN 43620 Part 1 and 3 Description NH Cooper Bussmann® aM fuse links have partial , motor protection relay. All fuse links are packed in 3's Packaging Catalogue Symbol 500V: (amp)NHM(Size)B 690V: (amp)NHM(Size)B-690 B-690 Operation Class: aM Fuse Holders Fuse bases: SB*-D single-pole, TB*-D ... Original
datasheet

3 pages,
152.35 Kb

BUSSMANN 250NHM2B-690 20nhm000b-690 690VAC datasheet abstract
datasheet frame
Abstract: SYMBOL: (amp)NHG(Size)B HRC FUSE LINKS CLASS OF OPERATION gL/gG 500V AC 10 to 630 AMPS SIZES 000 to 3 A square bodied range of industrial fuse links for a wide variety of applications. 500V AC , Bussmann® NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 500V AC, 10 to , Description: Packaging: All fuse links are packed in 3's. Technical Data: Rated Voltage: Rated , Fuse Links NH Class of Operation gL/gG, 500V AC, 10 to 100 Amps Sizes 000 Time Current ... Original
datasheet

8 pages,
2172.39 Kb

10NHG000B 80NHG000B 50nhg000b IEC-60269 400 amp hrc fuse bussmann fuse 160 size 00 fuse links 63NHG000B 200NHG02B 35NHG000B DIN 72300 NH bussmann Fuse IEC60269 bussmann semiconductor fuse VDE0636 VDE0636 abstract
datasheet frame
Abstract: International Products NH Fuse Links 500 Volts · 2 30 Amperes ­6 Littelfuse European style NHfuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse , The aM characteristic fuse links are used for the shortcircuit protection of motors and switchgear. , 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 1:1 25 All NH fuse links incorporate a blown fuse , © 2005 Littelfuse · POWR-GARDTM Products Catalog International Products NH Fuse Links NH Fuse ... Original
datasheet

2 pages,
114.44 Kb

IEC 269-2-1 NH00C 80 aM NH1M160 NH00CG6 ,690V NH00 125A 160A Fuse NH3 fuse aM NH00CG80 NH00G125 NH00CG63 NH fuse 500 A nh00 fuse FUSE 315A NH2 size 00 fuse links NH00C NH00C abstract
datasheet frame

Datasheet Content (non pdf)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2014): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
Links: International Congress 42V PowerNet MIT/Industry consortium on Advanced Date/State Size Date/State Size SAE_00_door_foils1.pdf 03.00 822 kB Fuse Function with PROFET Highside Power Switches - english version
www.datasheetarchive.com/files/infineon/wwwinf~1.com/produc~1/sol_c~88.htm
Infineon 26/10/2000 44.25 Kb HTM sol_c~88.htm
No abstract text available
www.datasheetarchive.com/download/48609126-16898ZD/publikationen_e.xml
Epcos 23/10/2002 66.35 Kb XML publikationen_e.xml
ST75C520 ST75C520 ST75C520 ST75C520 - USER'S MANUAL ST75C520 ST75C520 ST75C520 ST75C520 ST75C52 ST75C52 ST75C52 ST75C52 Document Format Size and to select the long train sequence use the same command with the first parameter equal to $00 P4 V.17 14400 CONF $0F $09 $00 $04 V.17 12000 CONF $0F $09 $00 $02 V.17 9600 CONF $0F $09 $00 $01 V.17 7200 CONF $0F $09 $80 $00 V.29 9600 CONF $0F $08 $00 $01 V.29 7200 CONF $0F $08 $80 $00 V.29 4800 CONF $0F $08 $40 $00 V.27 ter 4800 CONF $0F $07 $40 $00 V.27
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/5638-v2.htm
STMicroelectronics 25/05/2000 153.86 Kb HTM 5638-v2.htm
MANUAL ST75C520 ST75C520 ST75C520 ST75C520 ST75C52 ST75C52 ST75C52 ST75C52 Document Format Size Document Number Date $00. In this example we do not select the transmit equal- izer, the RTS signal is not used and the V.17 14400 CONF $0F $09 $00 $04 V.17 12000 CONF $0F $09 $00 $02 V.17 9600 CONF $0F $09 $00 $01 V.17 7200 CONF $0F $09 $80 $00 V.29 9600 CONF $0F $08 $00 $01 V.29 7200 CONF $0F $08 $80 $00 V.29 4800 CONF $0F $08 $40 $00 V.27 ter 4800 CONF $0F $07 $40 $00 V.27 ter 2400 CONF
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/5638.htm
STMicroelectronics 20/10/2000 160.3 Kb HTM 5638.htm
No abstract text available
www.datasheetarchive.com/download/64007008-139818ZD/00104f.zip (00104f.pdf)
Microchip 01/06/2002 87251.33 Kb ZIP 00104f.zip
bond wires and fuse die metalization (Figures 2 and 3). The average bond wire for a 68HC05 68HC05 68HC05 68HC05 device is 1 ml in diameter and approximately 60 mils long. A direct current of 1 Amp would be sufficient to fuse a bond wire of this dimension. Higher current pulses of shorter duration also could fuse a bond wire. For example, a 5 Amp, 1 msec pulse would most likely fuse the average bond wire. In both these gold bond wire, the wire will fuse.The second mechanism associated with an EOS event is fusing of
www.datasheetarchive.com/files/motorola/faq/mcufaq.txt
Motorola 21/02/2000 401.87 Kb TXT mcufaq.txt
Small size, low power consumption, and flexibility make these devices ideal for unattended '91 '92 '93 '94 '95 '96 '97 '98 '99 '00 4-bit 1,393 1,597 1,596 1,698 1,761 1 '97 '98 '99 '00 4-bit 778 906 979 1036 1063 1110 1100 1096 1064 1025 970 '95 '96 '97 '98 '99 '00 $ 595 634 712 905 1,068 1,237 1,339 1,410 1,574 1,852 2 bad as 44 weeks. Software protection Either by encryption or fuse protection, the
www.datasheetarchive.com/files/stmicroelectronics/stonline/products/support/mcu8/common/mcu_faq.htm
STMicroelectronics 28/09/1999 189.34 Kb HTM mcu_faq.htm
Small size, low power consumption, and flexibility make these devices ideal for unattended '91 '92 '93 '94 '95 '96 '97 '98 '99 '00 4-bit 1,393 1,597 1,596 1,698 1,761 1 '97 '98 '99 '00 4-bit 778 906 979 1036 1063 1110 1100 1096 1064 1025 970 '95 '96 '97 '98 '99 '00 $ 595 634 712 905 1,068 1,237 1,339 1,410 1,574 1,852 2 bad as 44 weeks. Software protection Either by encryption or fuse protection, the
www.datasheetarchive.com/files/stmicroelectronics/st9oncd/htm/faq/mcu_faq.htm
STMicroelectronics 23/03/1998 189.34 Kb HTM mcu_faq.htm
bond wires and fuse die metalization (Figures 2 and 3). The average bond wire for a 68HC05 68HC05 68HC05 68HC05 device is 1 ml in diameter and approximately 60 mils long. A direct current of 1 Amp would be sufficient to fuse a bond wire of this dimension. Higher current pulses of shorter duration also could fuse a bond wire. For example, a 5 Amp, 1 msec pulse would most likely fuse the average bond wire. In both these gold bond wire, the wire will fuse. The second mechanism associated with an EOS event is fusing of die
www.datasheetarchive.com/files/motorola/faq/index.htm
Motorola 21/02/2000 441.5 Kb HTM index.htm
bond wires and fuse die metalization (Figures 2 and 3). The average bond wire for a 68HC05 68HC05 68HC05 68HC05 device is 1 ml in diameter and approximately 60 mils long. A direct current of 1 Amp would be sufficient to fuse a bond wire of this dimension. Higher current pulses of shorter duration also could fuse a bond wire. For example, a 5 Amp, 1 msec pulse would most likely fuse the average bond wire. In both these gold bond wire, the wire will fuse. The second mechanism associated with an EOS event is fusing of die
www.datasheetarchive.com/files/motorola/faq/index-v1.htm
Motorola 21/02/2000 441.62 Kb HTM index-v1.htm