500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
CD4043BKMSR Intersil Corporation 4000/14000/40000 SERIES, HIGH LEVEL TRIGGERED R-S LATCH, TRUE OUTPUT, CDFP16, CERAMIC, DFP-16 visit Intersil
CD4099BKMSR Intersil Corporation 4000/14000/40000 SERIES, LOW LEVEL TRIGGERED D LATCH, TRUE OUTPUT, CDFP16, CERAMIC, DFP-16 visit Intersil
CD4099BDMSR Intersil Corporation 4000/14000/40000 SERIES, LOW LEVEL TRIGGERED D LATCH, TRUE OUTPUT, CDIP16, SIDE BRAZED, CERAMIC, DIP-16 visit Intersil
CD4043BDMSR Intersil Corporation 4000/14000/40000 SERIES, HIGH LEVEL TRIGGERED R-S LATCH, TRUE OUTPUT, CDIP16, SIDE BRAZED, CERAMIC, DIP-16 visit Intersil
ISL54302IRZ Intersil Corporation 12V, 1.5? Quad SPST Switch with Latched Parallel Interface; QFN20; Temp Range: -40° to 85°C visit Intersil Buy
ISL54302IRZ-T Intersil Corporation 12V, 1.5? Quad SPST Switch with Latched Parallel Interface; QFN20; Temp Range: -40° to 85°C visit Intersil Buy

relay latch

Catalog Datasheet MFG & Type PDF Document Tags

relay latch

Abstract: sh-2001c LATCHING RELAY LATCH INPUT Relay will unlatch if any input (1, 2, 3) goes LOW. DTL INTERFACE DRIVER Rl
-
OCR Scan

SH2002

Abstract: relay latch TEST 3 #327 BULBS LATCHING RELAY LATCH INPUT Relay will unlatch if any input (1, 2, 3) goes LOW
-
OCR Scan

Metal Detector

Abstract: long range metal detector Memory Presets via PLC binary Max. 8 Max. 8 Relay latch with remote reset Programmable relay response time Automatic nominal adjustment for secondary roll stock steel , Programmable relay response time Automatic nominal adjustment for Adjustable tolerance
-
Original

FX2N-128MR

Abstract: mitsubishi plc FX2n-32mt SERIES X0-X267 184 points Y0-Y267 General use Auxiliary relay Latch* Special purpose General use State Latch , f M PU's starts at just 16 I/O points and, w ith both relay and transistor outputs, increases to an , expansion units increase expandability. Available in both relay and transistor output types the FX2N , Segment With Latch - Multiplexed 7-segment display output Arrow Switch - Create user-defined numeric data , ) 87 x 90 x 130 87 x 90 x 150 Relay 87 x 90 x 182 87 x 90 x 220 87 x 90 x 280 87 x 90 x 350 87 x 90 x
-
OCR Scan
FX2N-128MR mitsubishi plc FX2n-32mt SERIES fx2n-48mr FX2N-16EX FX2N-48MT FX2N-32MR FX-64M EX2N-64M 16M-34M 48M-128M FX2N-32M FX2N-48M

Protector Trip Relays

Abstract: protector . When the monitored parameter deviates from the desired set trip limit, the relay will operate to , 27 373-ELR Earth Leakage Protection Relay â'¢ Protection of power assets â'¢ Detection and , '¢ â'¢ â'¢ â'¢ 30 373-GFR Ground Fault Relay Application 33 1 AC Current AC , longer than the time delay, the relay will operate providing an alarm control or tripping signal. Basic , measured signal is noisy or unstable. Relay will trip if the measured current moves outside the set point
TE Connectivity
Original
Protector Trip Relays protector CBT-94F CI-EPP-2040-12/12-PTR

westinghouse breaker

Abstract: ND312T33W TYPE "P" CONTROL RELAY CROSS-REFERENCE . 72 CONTACTS, SUPPRESSORS AND , TERMINAL BLOCK . DISCONNECT (REF: 2100-3.0) RELAY , INTERLOCK . LATCH . TORQUE , TRANSFORMER (CONTROL) . UNIT LATCH . 24 18 96 16 , SUPPRESSORS BULLETIN 500 . BULLETIN 100 - 104 . RELAY
-
Original
westinghouse breaker ND312T33W Cutler-Hammer Digitrip RMS 310 Westinghouse mcc 2100 Cutler-Hammer Digitrip RMS 310 trip unit Cutler-Hammer Digitrip RMS 310 rating plug A128502 A483339 A483344 B677442 B677452 C933199

1440-DYN02-01RJ

Abstract: EK-44395 the Relay Properties . . . . . . . . . . . . . . . . . . . . Save Module Configuration and Download , Setpoint Multiplier Indicator . . . . . . . . . . . . . . . . . . . . . . . . Relay Indicator . . . . . . , 130 130 131 131 132 132 132 132 134 5 Table of Contents Relay Object (Class ID 323H , processing of critical vibration parameters, as well as advanced alarm and relay logic. It can be
Rockwell Automation
Original
1440-DYN02-01RJ EK-44395 1440-ACNR self powering tacho ATEX iepe circuit EN60079-0 ICM-UM002C-EN-E PN-70210

bulletin 700 type n

Abstract: bulletin 700 type n relay time interval from latch coil energization to the functioning time of the last contact on the relay , time of the last contact on the relay to reset. The latch and reset curves shown in Figures 5 thru 10 , NC cartridges, and it also includes variation from relay to relay. Note: The latch and reset curves , . MODE A OPERATION -See Figures 5 and 6 The relay is reset. The latch and reset coils are de-energized , for at least the maximum time period shown on the latch and reset time curves. - The relay is
Allen-Bradley
Original
bulletin 700 type n bulletin 700 type n relay bulletin 700 n type 700-CR5 Allen-Bradley starter 709 Bussman KAB A25X20

pneumatic timer

Abstract: D26MR40 Front Attachment, Pneumatic Timer, SolidState Timer or Mechanical Latch Relay Base Assembly D26MB , D26MR53 D26MR44 D26MR35 D26MR26 D26MR17 D26MR08 Relay with Mechanical Latch Catalogue Number D26MR202 , D26MD20 D26MD40 Transient Suppressor May be mounted on any 120V AC relay magnet coil or latch coil or , -pole D26 relay without latch. Timer unit has DPDT timed contacts (circuits in each pole must be the same , Opening DC Type M Relay with Latch Relay DC Input Coil Pick-Up Convertible Contacts LS1 L Hold
EATON
Original
D26MF D26MPR LR353 D26MRD005 D26MRD006 pneumatic timer D26MR40 D26MRD602 D26MR40A D26MR112 D26MD10 D26MPS D26MPL D26MPF

DPDT relay 12v

Abstract: 12V 10A RELAY / T-Brkt Diode 10 0 $11.02 RH2LB-UAC120V RH2LB-UAC120V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UAC12V RH2LB-UAC12V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UAC240V RH2LB-UAC240V DPDT LATCH RELAY 10 0 $30.73 RH2LB-UAC24V RH2LB-UAC24V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UAC6V RH2LB-UAC6V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UDC12V RH2LB-UDC12V DPDT LATCH RELAY 10 0 $25.64 RH2LB-UDC24V RH2LB-UDC24V DPDT LATCH RELAY 10 0 $25.64
IDEC
Original
DPDT relay 12v 12V 10A RELAY rh2lb-u U908 RH2B-ULAC24V RH2B-UDC12V U908-0 SHP02 AC24V RH4B-UCAC24V RH4B-UCDC110V RH4B-UCDC12V

omron pt100

Abstract: K8AB-TH12S (relay) output Fail safe, Alarm (relay) output Note: The output latch is reset using the output latch , output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON the , Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and , relay: Non-fail safe/fail safe. · Alarm status identification with LED indicator. · CE Marking UL/CSA certification pending. Features · This Temperature Monitoring Relay was designed specially for monitoring
OMRON
Original
omron pt100 K8AB-TH12S motor PT100 connected diagram PT100 omron pt100 relay pt100 thermometer N150-E1-01 75-344-7080/F 0805-1M

"RF Receiver"

Abstract: relay features dimension error DIP I/C PROFILE · SINGLE RELAY OPTION AVAILABLE · SUPPLIED AS AM OR FM COMPATIBLE. · , , MOMENTARY OR LATCHING. · SINGLE SUPPLY EITHER 5V OR 12V · LOW POWER CONSUMPTION RELAY · , profile as a standard 40pin DIL I/C for easy pcb mounting. A single relay option is an extended length module (removable) containing a BT/47 type relay. Supplied as either AM or FM, the module requires connections to the power supply; 5Vdc or 12Vdc (mandatory for relay version), and data outputs only. An LED
RF Solutions
Original
relay features dimension error 5 pin 12v relay 4 channel rf relay board RX FM 30 Mhz motorcycle remote control security system block diagram 433MH ETS300-339 DS000011

K8AB-TH12S

Abstract: Output relay External inputs (for latch setting) Contact input Non-contact input K8AB-TH11S K8AB-TH12S , ) indicator Latch reset (See note.) Non-fail safe, Alarm (relay) output Fail safe, Alarm (relay) output Note: The output latch is reset using the output latch reset button on the Temperature Monitoring Relay or , safe, Alarm (relay) output Fail safe, Alarm (relay) output Output Latch Disabled Power supply , the output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON
-
Original
PFP-100N PFP-50N
Abstract: latch function is that the relay can be kept energized even after the end of the alarm condition , Operation Diagrams Latch function - NE relay Power supply Latch contact (Closed = latch not active , '¢ Output: 8 A SPDT relay N.D. or N.E. selectable â'¢ For mounting on DIN-rail in accordance with DIN/EN , (PWB01) â'¢ LED indication for relay, alarm and power supply ON PWB01 Product Description , loads, where the power factor is almost proportional to the load. The relay measures the power -
Original
DWB01 DWB01CM2310A PWB01CM2310A

NEC RELAY

Abstract: IEC60255 application for latch type) Note 1. There are two specification in operate voltage of Non-latch type relay , DATA S H E E T MINIATURE SIGNAL RELAY ED2/EF2 SERIES Ultra-low power, compact and , reliability between the relay terminal and PCB by optimization of the terminal configuration; 20 , pins at the right end applies to double coil latch type only. Type EF2-. EF2-.NU EF2-.NUX , 0.004) Note 2. This pair of pads at the right end applies to double coil latch type only. 2.54
NEC / TOKIN
Original
NEC RELAY IEC60255 tokin LR46266 S7-200 code marking tokin IPC-SM-785 0123EMDD03VOL01E DE0202

NEC ee2-4

Abstract: NEC RELAY , SLIM-PACKAGE DESCRIPTION NEC TOKIN EC2/EE2 relay is a standard miniature signal relay, compact and slim , , Single coil latch type Double coil latch type 7.5 max. (0.30) 15.0 max. (0 59) 7.5 max. (0.30 , :±0.1 (Bottom view) (Bottom view) EE2 SERIES Non-latch type, Single coil latch type Double coil latch type 7.5 max. (0.30) 15.0 max. (0.59) 7.5 max. (0.30) 15.0 max. (0.59) 10.0 , ) Direction mark 1 3 4 5 +- Single coil latch type SR - + 12 10 9 8 S: Coil
NEC/TOKIN
Original
NEC ee2-4 relay 220vdc 10a NEC RELAY ee2-4 NEC lead relays MBB relay nec ec2

NEC lead relays

Abstract: LR46266 DATA S H E E T MINIATURE SIGNAL RELAY ED2/EF2 SERIES Ultra-low power, compact and , reliability between the relay terminal and PCB by optimization of the terminal configuration; 20 , 2.54 2.54 (0.20)(0.10)(0.10)(0.10) 0.25 (0.01) 3.2 (0.13) 0.5 (0.02) Double coil latch , and Single coil latch 2 × 2.54(0.100) ED2 SERIES 5 × 2.54 (0.100) (Bottom fiew) Note , coil latch type only. Type EF2-. EF2-.NU EF2-.NUX EF2-.NUH EF2-.NUN A 3.0 (0.118) 3.0
World Products
Original
ER0046EJ

12vdc relay

Abstract: bt47w ) OPEN CONNECTED OPEN CONNECTED RELAY 1 O/P MOMENTARY MOMENTARY MOMENTARY LATCH RELAY 2 O/P MOMENTARY MOMENTARY LATCH LATCH RELAY 3 O/P MOMENTARY LATCH LATCH LATCH RELAY 4 O/P MOMENTARY LATCH LATCH LATCH Note : In momentary mode the relay will operate for as long as the transmitter , FEATURE MOMENTARY OR LATCHING RELAY OUTPUTS LED INDICATION OF DATA RECEPTION Rx DECODER CAN LEARN UP TO , rated 5A @ 240Vac. The relay outputs for each of channel are set to either momentary or latching by two
RF Solutions
Original
12vdc relay bt47w latch relay relay latch RF decoder RX 433 reciever AM-008C AMS-008C FM-008C BT47W/6 JV12K AM-0083B-433

aSYNCHRONOUS MOTOR WIRING

Abstract: asynchronous motor 5 6 7 4 3 1 10 Operation Diagrams Latch function - NE relay Power supply , relay N.D. or N.E. selectable · For mounting on DIN-rail in accordance with DIN/EN 50 022 (DWB01) or , indication for relay, alarm and power supply ON PWB01 Product Description Ordering key DWB01 and , factor is almost proportional to the load. The relay measures the power factor (cos ), that is the , motor, without the need of an auxiliary device. The advantage of using the latch function is that
Carlo Gavazzi
Original
aSYNCHRONOUS MOTOR WIRING asynchronous motor

bulletin 700 type n

Abstract: Allen-Bradley 800T bar also gives visual indication of relay operation. Both Type N electrically held and Type NM latch , '" Permanent Magnet Latch AC Relay  Contact A Arrangement g Cat. No. V â'" 700-N601  , 50 milliseconds.  Location of contacts in 4 pole latch relays: 2 pole relay plus the 2 contacts , '" 5 Contact A Arrangement g â'" 4 Permanent Magnet Latch DC Relay › R la â'" 3 , maintained for minimum time of 50 milliseconds.  Location of contacts in 4 pole latch relays: 2 pole relay
Rockwell Automation
Original
Allen-Bradley 800T 700DC-NT200 700DC-NT300 700DC-N400 852S-C ALLEN-BRADLEY POTENTIOMETER