500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
RELAYIOMINI Tripp Lite UPS CONTACT CLOSURE MGT ACC CARD visit Digikey
RELAYIOCARD Tripp Lite PROGRAMMABLE I/O CARD SMART UPS visit Digikey
IR-1900-RELAY-1CR/2CR TE's AMP RELAY DPST 220VAC visit Digikey
IR-1900-RELAY-CRM/CRF TE's AMP RELAY 4PDT 220VAC visit Digikey
VI800A-RELAY FTDI Chip RELAYS OPTO-ISOLATED INPUTS BRID visit Digikey
IR-1900-RELAY-3CR/4CR TE's AMP RELAY DPDT 220VAC visit Digikey

relay latch

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: LATCHING RELAY LATCH INPUT Relay will unlatch if any input (1, 2, 3) goes LOW. DTL INTERFACE DRIVER Rl -
OCR Scan
SH2001 SH2002 H2002 10-PIN SH2002HC SH2001HM sh-2001c sh2001fc SH2001-SH2002
Abstract: TEST 3 #327 BULBS LATCHING RELAY LATCH INPUT Relay will unlatch if any input (1, 2, 3) goes LOW -
OCR Scan
SH2001HC SH2002HM
Abstract: Memory Presets via PLC binary Max. 8 Max. 8 Relay latch with remote reset Programmable relay response time Automatic nominal adjustment for secondary roll stock steel , Programmable relay response time Automatic nominal adjustment for Adjustable tolerance -
Original
P70T30S P160B Metal Detector long range metal detector metal detector sensor metal detector probe sensor metal detectors circuit DS100-DS101 PD100 DS3400-DS3410 DS150-DS1520 SD200-203 P70CS
Abstract: X0-X267 184 points Y0-Y267 General use Auxiliary relay Latch* Special purpose General use State Latch , f M PU's starts at just 16 I/O points and, w ith both relay and transistor outputs, increases to an , expansion units increase expandability. Available in both relay and transistor output types the FX2N , Segment With Latch - Multiplexed 7-segment display output Arrow Switch - Create user-defined numeric data , ) 87 x 90 x 130 87 x 90 x 150 Relay 87 x 90 x 182 87 x 90 x 220 87 x 90 x 280 87 x 90 x 350 87 x 90 x -
OCR Scan
FX2N-128MR mitsubishi plc FX2n-32mt SERIES fx2n-48mr FX2N-16EX FX2N-48MT FX2N-32MR FX-64M EX2N-64M 16M-34M 48M-128M FX2N-32M FX2N-48M
Abstract: . When the monitored parameter deviates from the desired set trip limit, the relay will operate to , 27 373-ELR Earth Leakage Protection Relay â'¢ Protection of power assets â'¢ Detection and , '¢ â'¢ â'¢ â'¢ 30 373-GFR Ground Fault Relay Application 33 1 AC Current AC , longer than the time delay, the relay will operate providing an alarm control or tripping signal. Basic , measured signal is noisy or unstable. Relay will trip if the measured current moves outside the set point TE Connectivity
Original
CBT-94F CI-EPP-2040-12/12-PTR
Abstract: TYPE "P" CONTROL RELAY CROSS-REFERENCE . 72 CONTACTS, SUPPRESSORS AND , TERMINAL BLOCK . DISCONNECT (REF: 2100-3.0) RELAY , INTERLOCK . LATCH . TORQUE , TRANSFORMER (CONTROL) . UNIT LATCH . 24 18 96 16 , SUPPRESSORS BULLETIN 500 . BULLETIN 100 - 104 . RELAY -
Original
westinghouse breaker ND312T33W Cutler-Hammer Digitrip RMS 310 Westinghouse mcc 2100 100-A18ND3 Cutler-Hammer hfd 65k A128502 A483339 A483344 B677442 B677452 C933199
Abstract: the Relay Properties . . . . . . . . . . . . . . . . . . . . Save Module Configuration and Download , Setpoint Multiplier Indicator . . . . . . . . . . . . . . . . . . . . . . . . Relay Indicator . . . . . . , 130 130 131 131 132 132 132 132 134 5 Table of Contents Relay Object (Class ID 323H , processing of critical vibration parameters, as well as advanced alarm and relay logic. It can be Rockwell Automation
Original
1440-DYN02-01RJ EK-44395 1440-ACNR self powering tacho ATEX iepe circuit EN60079-0 ICM-UM002C-EN-E PN-70210
Abstract: time interval from latch coil energization to the functioning time of the last contact on the relay , time of the last contact on the relay to reset. The latch and reset curves shown in Figures 5 thru 10 , NC cartridges, and it also includes variation from relay to relay. Note: The latch and reset curves , . MODE A OPERATION -See Figures 5 and 6 The relay is reset. The latch and reset coils are de-energized , for at least the maximum time period shown on the latch and reset time curves. - The relay is Allen-Bradley
Original
bulletin 700 type n bulletin 700 type n relay bulletin 700 n type Bussman KAB 700-CR5 Allen-Bradley starter 709 A25X20
Abstract: Front Attachment, Pneumatic Timer, SolidState Timer or Mechanical Latch Relay Base Assembly D26MB , D26MR53 D26MR44 D26MR35 D26MR26 D26MR17 D26MR08 Relay with Mechanical Latch Catalogue Number D26MR202 , D26MD20 D26MD40 Transient Suppressor May be mounted on any 120V AC relay magnet coil or latch coil or , -pole D26 relay without latch. Timer unit has DPDT timed contacts (circuits in each pole must be the same , Opening DC Type M Relay with Latch Relay DC Input Coil Pick-Up Convertible Contacts LS1 L Hold EATON
Original
D26MF D26MPR D26MRD005 D26MRD006 D26MR40 D26MRD602 pneumatic timer D26MR40A D26MRD202 D26MD10 D26MPS D26MPL D26MPF
Abstract: / T-Brkt Diode 10 0 $11.02 RH2LB-UAC120V RH2LB-UAC120V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UAC12V RH2LB-UAC12V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UAC240V RH2LB-UAC240V DPDT LATCH RELAY 10 0 $30.73 RH2LB-UAC24V RH2LB-UAC24V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UAC6V RH2LB-UAC6V DPDT LATCH RELAY 10 0 $27.43 RH2LB-UDC12V RH2LB-UDC12V DPDT LATCH RELAY 10 0 $25.64 RH2LB-UDC24V RH2LB-UDC24V DPDT LATCH RELAY 10 0 $25.64 IDEC
Original
DPDT relay 12v 12V 10A RELAY relay 240v 10a pcb RH2B-UDC12V RH2B-ULAC24V rh2lb-u U908-0 SHP02 AC24V RH4B-UCAC24V RH4B-UCDC110V RH4B-UCDC12V
Abstract: (relay) output Fail safe, Alarm (relay) output Note: The output latch is reset using the output latch , output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON the , Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and , relay: Non-fail safe/fail safe. · Alarm status identification with LED indicator. · CE Marking UL/CSA certification pending. Features · This Temperature Monitoring Relay was designed specially for monitoring OMRON
Original
omron pt100 K8AB-TH12S motor PT100 connected diagram PT100 omron pt100 relay pt100 thermometer N150-E1-01 75-344-7080/F 0805-1M
Abstract: DIP I/C PROFILE · SINGLE RELAY OPTION AVAILABLE · SUPPLIED AS AM OR FM COMPATIBLE. · , , MOMENTARY OR LATCHING. · SINGLE SUPPLY EITHER 5V OR 12V · LOW POWER CONSUMPTION RELAY · , profile as a standard 40pin DIL I/C for easy pcb mounting. A single relay option is an extended length module (removable) containing a BT/47 type relay. Supplied as either AM or FM, the module requires connections to the power supply; 5Vdc or 12Vdc (mandatory for relay version), and data outputs only. An LED RF Solutions
Original
relay features dimension error 4 channel rf relay board 5 pin 12v relay RX FM 30 Mhz relay ttl input 12v output 433MH ETS300-339 DS000011
Abstract: Output relay External inputs (for latch setting) Contact input Non-contact input K8AB-TH11S K8AB-TH12S , ) indicator Latch reset (See note.) Non-fail safe, Alarm (relay) output Fail safe, Alarm (relay) output Note: The output latch is reset using the output latch reset button on the Temperature Monitoring Relay or , safe, Alarm (relay) output Fail safe, Alarm (relay) output Output Latch Disabled Power supply , the output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON -
Original
PFP-100N PFP-50N
Abstract: latch function is that the relay can be kept energized even after the end of the alarm condition , Operation Diagrams Latch function - NE relay Power supply Latch contact (Closed = latch not active , '¢ Output: 8 A SPDT relay N.D. or N.E. selectable â'¢ For mounting on DIN-rail in accordance with DIN/EN , (PWB01) â'¢ LED indication for relay, alarm and power supply ON PWB01 Product Description , loads, where the power factor is almost proportional to the load. The relay measures the power -
Original
DWB01 DWB01CM2310A PWB01CM2310A
Abstract: application for latch type) Note 1. There are two specification in operate voltage of Non-latch type relay , DATA S H E E T MINIATURE SIGNAL RELAY ED2/EF2 SERIES Ultra-low power, compact and , reliability between the relay terminal and PCB by optimization of the terminal configuration; 20 , pins at the right end applies to double coil latch type only. Type EF2-. EF2-.NU EF2-.NUX , 0.004) Note 2. This pair of pads at the right end applies to double coil latch type only. 2.54 NEC / TOKIN
Original
NEC RELAY code marking tokin IEC60255 LR46266 NEC Tokin relay S7-200 IPC-SM-785 0123EMDD03VOL01E DE0202
Abstract: , SLIM-PACKAGE DESCRIPTION NEC TOKIN EC2/EE2 relay is a standard miniature signal relay, compact and slim , , Single coil latch type Double coil latch type 7.5 max. (0.30) 15.0 max. (0 59) 7.5 max. (0.30 , :±0.1 (Bottom view) (Bottom view) EE2 SERIES Non-latch type, Single coil latch type Double coil latch type 7.5 max. (0.30) 15.0 max. (0.59) 7.5 max. (0.30) 15.0 max. (0.59) 10.0 , ) Direction mark 1 3 4 5 +- Single coil latch type SR - + 12 10 9 8 S: Coil NEC/TOKIN
Original
NEC ee2-4 relay 220vdc 10a NEC RELAY ee2-4 NEC lead relays tokin signal relay
Abstract: DATA S H E E T MINIATURE SIGNAL RELAY ED2/EF2 SERIES Ultra-low power, compact and , reliability between the relay terminal and PCB by optimization of the terminal configuration; 20 , 2.54 2.54 (0.20)(0.10)(0.10)(0.10) 0.25 (0.01) 3.2 (0.13) 0.5 (0.02) Double coil latch , and Single coil latch 2 × 2.54(0.100) ED2 SERIES 5 × 2.54 (0.100) (Bottom fiew) Note , coil latch type only. Type EF2-. EF2-.NU EF2-.NUX EF2-.NUH EF2-.NUN A 3.0 (0.118) 3.0 World Products
Original
ER0046EJ
Abstract: ) OPEN CONNECTED OPEN CONNECTED RELAY 1 O/P MOMENTARY MOMENTARY MOMENTARY LATCH RELAY 2 O/P MOMENTARY MOMENTARY LATCH LATCH RELAY 3 O/P MOMENTARY LATCH LATCH LATCH RELAY 4 O/P MOMENTARY LATCH LATCH LATCH Note : In momentary mode the relay will operate for as long as the transmitter , FEATURE MOMENTARY OR LATCHING RELAY OUTPUTS LED INDICATION OF DATA RECEPTION Rx DECODER CAN LEARN UP TO , rated 5A @ 240Vac. The relay outputs for each of channel are set to either momentary or latching by two RF Solutions
Original
12vdc relay bt47w latch relay RF decoder 12V relay no ,nc RX 433 reciever AM-008C AMS-008C FM-008C BT47W/6 JV12K AM-0083B-433
Abstract: 5 6 7 4 3 1 10 Operation Diagrams Latch function - NE relay Power supply , relay N.D. or N.E. selectable · For mounting on DIN-rail in accordance with DIN/EN 50 022 (DWB01) or , indication for relay, alarm and power supply ON PWB01 Product Description Ordering key DWB01 and , factor is almost proportional to the load. The relay measures the power factor (cos ), that is the , motor, without the need of an auxiliary device. The advantage of using the latch function is that Carlo Gavazzi
Original
asynchronous motor aSYNCHRONOUS MOTOR WIRING
Abstract: bar also gives visual indication of relay operation. Both Type N electrically held and Type NM latch , '" Permanent Magnet Latch AC Relay  Contact A Arrangement g Cat. No. V â'" 700-N601  , 50 milliseconds.  Location of contacts in 4 pole latch relays: 2 pole relay plus the 2 contacts , '" 5 Contact A Arrangement g â'" 4 Permanent Magnet Latch DC Relay › R la â'" 3 , maintained for minimum time of 50 milliseconds.  Location of contacts in 4 pole latch relays: 2 pole relay Rockwell Automation
Original
Allen-Bradley 800T 700DC-N400 700DC-NT200 700DC-NT300 852S-C ALLEN-BRADLEY POTENTIOMETER 1270
Showing first 20 results.