500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

merlin gerin vigi C60

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: MERLIN GERIN multi 9 vigi C60 (AUS01PL08-A) T02 I N 0,030A a N/1 3 T N/2 4 test , 947.2 2 4 6 24217 O - OFF O - OFF O - OFF MERLIN GERIN multi 9 vigi C60 I N 0 , 23974 O - OFF O - OFF O - OFF O - OFF MERLIN GERIN multi 9 vigi C60 I N 0,300A a N , C60N/H miniature circuit breakers Multi 9 Merlin Gerin The C60N circuit-breaker is a miniature , Remote control (AUS01PL18-A) A1 MERLIN GERIN multi 9 C60N MERLIN GERIN multi 9 Tm Merlin Gerin
Original
merlin gerin C60n merlin gerin C60 multi 9 C60N schneider merlin gerin C60H C60N merlin gerin multi 9 C60N AUS01PL06-A N13634 AUS01PL04-A
Abstract: C60/C120 Fehlerstromschutzschalter C60/C120 Vigi, C60/C120 Vigi «si» 1 Leitungsschutzschalter , 14 15 16 17 18 19 20 37 multi 9 Merlin Gerin Verriegelungselement trennbarer Sockel , Bemessungsisolationsspannung: 250 V c Kurzschlussfestigkeit: mit den Ausschaltvermögen der Merlin Gerin , Kurzschlussfestigkeit: mit den Abschaltvermögen der Merlin Gerin Leitungsschutzschalter kompatibel Anschlusskämme , ) c mit allen Merlin Gerin Anschlusskämmen kompatibel c hohe Stabilität durch Aufstecken auf die -
Original
NG125 merlin gerin multi 9 vigi dpn Schneider Electric Multi 9 schneider C60 merlin gerin multi 9 vigi c60 merlin gerin 26929 SCHNEIDER 26927 C60/C120 RAL7016
Abstract: Accessories for C60/C120 Circuit breaker Multi 9 Merlin Gerin Screw shield s Prevents contact , busbars used for device power supply. The rang e C60/C120 Circuit breaker MERLIN GERIN multi 9 , 1 1 1 1 1 1 1 1 1 MERLIN GERIN multi 9 C120N C63 415Va 10000 3 Clip-on markers 1 3 2 4 18360 Comb busbars O - OFF O - OFF 2P MERLIN GERIN , Terminal shield Screw shield Padlocking accessory MERLIN GERIN multi 9 C120N C63 1 3 5 7 Schneider Electric
Original
BUSCOMB12P merlin gerin C120n Merlin Gerin CIRCUIT BREAKER schneider C120N DPN vigi merlin gerin catalogue merlin gerin comb busbar 240/415V 100/125A BUSCOMB17P C120/NG125 AUS01PL07-A
Abstract: Merlin Gerin protection des circuits disjoncteurs jusqu'à 63 A auxiliaires électriques pour C60 , la distribution BT, page K4 Dimensions : page A138 Merlin Gerin catalogue distribution BT 95 , autres caractéristiques : identiques à celles du C60N courbe C. blocs différentiels Vigi pour C60 = Disjoncteur différentiel C60 Ces blocs différentiels appelés blocs Vigi se fixent sur le côté , Disjoncteur C60 Bloc Vigi C60 Accessoires : pages A41 et A42 Auxiliaires électriques : pages A40 -
Original
NC100H C32H-DC merlin catalogue 24171 Merlin Gerin disjoncteur differentiel merlin gerin C60n 24228 100H/LH/ C60N/ NC100H/ C60L/
Abstract: : page 31 Merlin Gerin circuit breakers C60 N UL 489 CSA 22.2 No 5.1 UL Listed for branch , lug/box lug Merlin Gerin 5 circuit breakers C60 N UL 489 CSA 22.2 No 5.1 UL Listed for , times ampere rating 6 Merlin Gerin circuit breakers C60 N UL 489 CSA 22.2 No 5.1 UL Listed , 31 Merlin Gerin circuit protection electrical auxiliaries for C60, C120 Applications + , 25 25 20 30 25 25 Merlin Gerin dimensions multi 9 C60 C120 circuit breakers Schneider Electric
Original
Merlin Gerin shunt trip mx merlin gerin NS100N merlin gerin 26924 merlin gerin multi 9 merlin gerin NS250N merlin gerin NS250h C120H NC100L NC100LH NC100 UL489 378576-M
Abstract: 416 420 425 432 440 450 463 Vigi C60 Add on residual current device for use with C60 MCBs , alone. = + MCB 2P Vigi Effectively creating an RCBO to BS EN 61009, C60 MCBs with add on , 63 300 4 63 300 Terminal screw shields available for Vigi RCDs. See C60 accessories on page 26 , Part No. MGLAP 26970 Screw shield Breaker C60 Breaker C60 Vigi Quantity Sealable 1P , 10 Outgoers: MCBs RCBOs 2 pole Vigi Auxiliaries Distribution board accessories * for use Merlin Gerin
Original
merlin gerin multi 9 ihp 1c manual NS800N telemecanique contactor catalogue merlin gerin multi 9 ihp 1c schneider NS1250N Merlin Gerin NS1250N MGLV5750
Abstract: Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers Get more with the world's Power & Control specialist Protection Merlin Gerin Multi 9 System Miniature circuit breakers , + N or - 91-92 L or + N or - Page 15 protection Vigi modules for C60 and C120 , /60Hz c Minimum operating threshold for test button v Vigi C60 : 100VAC v Vigi C120 : 176VAC c AS3190, AS/NZS61009 (IEC61009) c Connection by tunnel terminals v Vigi C60 : up to 35mm2 stranded Schneider Electric
Original
c60 tripping curves Schneider contactor catalogue c60 tripping D curve C60H Circuit Breakers Catalogue C60H schneider schneider SHUNT TRIP AUS010302
Abstract: applications Page 170 400Hz operation contact Merlin Gerin. 46 C60HB/HC/HD miniature circuit breakers , combinations of these with VIGI (type C60) residual current devices. Interpole barrier Supplied in , Contents Axiom MCB's features and benefits C60 features and benefits Axiom MCB outgoers C60 , available. C60X MCB single pole 41 C60 features and benefits Miniature circuit breaker s MCB , and 4 pole. s B, C and D ratings 1 - 63A. Vigi earth fault module A range of residual current -
Original
NC100LMA telemecanique magnetic contactor V40h merlin gerin DC 24V double POLE MCB IEC 60898 category C Multi 9 C60HD
Abstract: combined rcd/mcb or by combining a vigi module with an mcb. time (s) Merlin Gerin 300mA time , 350 400 Hz Vigi C60 2 and 4 pole, 220/415V - 50Hz Operating residual current variation curves , peak 10 to 25 In In t 169 Protection Earth faults Introduction Merlin Gerin's range , sensitivities offered by the Merlin Gerin range of rcd's is as follows: RCD Permissible Sensitivity earth , capacitive loads (RF filter networks, mineral insulated cables etc) All Merlin Gerin rcd's and rcd/mcb -
Original
Merlin Gerin NS630N merlin gerin ns160n C801N NS250N Merlin Gerin mccb C801N MERLIN GERIN MCCB2503D4P MGB12N C60HB C60HC 5-10I C60HD
Abstract: 6 F32 Multi 9â"¢ -C32 Multi 9 -C60 Acti 9 - iC60 Acti 9 gives you safety, simplicity , pole 3 pole 4 pole Residual current circuit breaker Vigi r devic 100% 100% safe for , Residual current devices Vigi iC60 iC60 RCBO RCD Type AC, A, SI A Type 2P, 3P, 4P , and iC60 Vigi Residual current circuit breakers iID RCD Type Asi, A, AC, B Type 2P , 5.5 45 110 55 15 15 iC60H2 RCBO 41 Vigi iC60 add-on residual current devices Schneider Electric
Original
IC60H SEA9NTB2504 A9F54350 SEA9BN24TN SEA9AN10PS merlin gerin isobar 4c IP20B SE7856
Abstract: 6 F32 Multi 9â"¢ -C32 Multi 9 -C60 Acti 9 - iC60 Acti 9 gives you safety, simplicity , 2 pole 3 pole 4 pole Residual current circuit breaker Vigi r devic 100% 100% safe , , C, D Standards IEC/EN 60947-2, 60898-1 iDPNN Vigi RCBO RCBO devices Vigi iC60 , iC60 and iC60 Vigi â'˜Quick connectionâ'™ up to 40A Residual current circuit breakers iID , iC60H RCBO 47 iDPN Vigi 49 iC60 Vigibloc 52 Residual Current Circuit Breakers 55 iID Schneider Electric
Original
A9F44220 CA907021 IC60N 1P N IC60N C CURVE