500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : CWR09NC475MCB\\TR Supplier : AVX Manufacturer : Avnet Stock : - Best Price : $26.3579 Price Each : $29.5869
Part : CWR11KH156MCB\\TR Supplier : AVX Manufacturer : Avnet Stock : - Best Price : $39.9492 Price Each : $44.8433
Part : S-8521C32MC-BTRT2G Supplier : SII Semiconductor Manufacturer : Avnet Stock : - Best Price : $0.4578 Price Each : $0.50
Part : SAFC164CI8EMCBTR Supplier : Infineon Technologies Manufacturer : Avnet Stock : - Best Price : - Price Each : -
Part : CWR11KH156MCBTR Supplier : AVX Manufacturer : Newark element14 Stock : - Best Price : $39.67 Price Each : $50.37
Shipping cost not included. Currency conversions are estimated. 

mcb tripping curves

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: closed N mcb open Under voltage release unit (MN) to ensure automatic tripping in case of under , Miniature circuit breakers Breaking capacities Tripping characteristics Miniature circuit breaker (magnetic trip setting) Type C60HB MCB (type B: 3-5In) C60HC MCB (type C: 5-10In C60HD MCB (type D: 10-14In) C120 HB MCB C120 HC MCB C120 HD MCB NG125 N NG125 H Ratings (A) 1A to 63A , ,000 2,3,4P 440V 10,000 15,000 15,000 15,000 25,000 36,000 Note: For UL/CSA approved MCB -
Original
NG125N c60 tripping curves NS400H NC100H NG125H Multi 9 C60HD 5-10I 10-14I 50/60H EC947-2
Abstract: overloads and fault current situations are dealt with using the magnetic tripping mode of the MCB. This , suitable MCB. In all instances, reference should be made to both the motor manufacturer's curves and MK , Sentry MCB features tunnel terminals of generous capacity, with 25mm2 on ratings up to and including , and feature combination heads. Retrofit kit 5567s The Sentry MCB/RCBO retrofit kit is designed for use when installing MCB/RCBOs into superceded Sentry Consumer Units. The kit contains a busbar MK Electric
Original
MCB ENERGY LET THROUGH MCB ENERGY LET THROUGH 60898 type b motor current mcb tripping type c mcb tripping curves Circuit Breakers to BS EN 60898 type 2 mcb
Abstract: protection C60a Miniature circuit-breakers B and C tripping curves IEC 898: 4500 , IEC 947-2: 5kA type , circuit-breakers B, C and D tripping curves IEC 898: 6000 , IEC 947-2: 10kA 24395 24331 24344 24357 , : page 31 3 circuit protection C60H Miniature circuit-breakers B, C and D tripping curves IEC , above Vigi module can always be assembled on the right hand side of an mcb. + Remote Tripping , tripping of an mcb. This device offers the following: v a red flag trip indicator, v ability to reset Schneider Electric
Original
Merlin Gerin shunt trip mx merlin gerin NS100N Merlin Gerin CIRCUIT BREAKER merlin gerin catalogue merlin gerin C60n merlin gerin C60 multi 9 C120N C120H NC100L NC100LH NC100 UL489
Abstract: 10 kA (BS EN 60898-1) 10 kA (BS EN60947-2) Tripping curves "C" magnetic setting between 5 and , "C" In 80 to 125 A 15 kA (BS EN 60898-1) 15 kA (BS EN60947-2) Tripping curves "C" , 15 kA (BS EN 60898-1) 15 kA (BS EN60947-2) Tripping curves "D" magnetic setting between 10 , data Type B tripping characteristics complies with BS EN 60-898. Calibration temperature 30 , Width in z 17.5mm pack qty. Cat Ref. Single pole MCB 6 1 12 MTN106 10 1 -
Original
mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb MCCB wiring diagram MZ528 MZ529 MZ520 MZ527
Abstract: Applications | Technical catalogue high performance MCB's rated tripping current, current rating up to 125A , Technical catalogue 2010 S800/S500 The High Performance MCB High performance MCB S800 and , | Technical catalogue high performance MCB's Table of content Applications Seite 0/4 S800 Ordering , performance MCB's | Applications 0/3 Overview S800 Series S800S Characteristics B, C, D K , performance MCB's 30 S800N S800C S800U S800PV B, C, D B, C, D, K K, Z S ABB Automation
Original
S800-SOR S800S-UC IEC 60947-2 ABB S803-BB250 ABB DC Main Circuit breaker 2POLE A9-30-10 1200VDC 1000VAC 2CCC413003C0201
Abstract: 10 kA (BS EN 60898-1) 10 kA (BS EN60947-2) Tripping curves "C" magnetic setting between 5 and , "C" In 80 to 125 A 15 kA (BS EN 60898-1) 15 kA (BS EN60947-2) Tripping curves "C" , 15 kA (BS EN 60898-1) 15 kA (BS EN60947-2) Tripping curves "D" magnetic setting between 10 , data Type B tripping characteristics complies with BS EN 60-898. Calibration temperature 30 , Width in z 17.5mm pack qty. Cat Ref. Single pole MCB 6 1 12 MTN106 10 1 -
Original
wiring diagram of rccb HD149U rcbo circuit diagram HMF280T bs 1361 ADA925U
Abstract: . Tripping characteristic curves (EN/IEC 60898-1) Magnetic release An electromagnet with plunger ensures , . Technical data - MCB's Tripping current variations 60Hz 1 100Hz 1.1 200Hz 1.2 300Hz 1.4 400Hz 1.5 , the MCB can operate without unwanted tripping. Calculation The correction factor K=0.7, for use in an , short-circuit for MCB's, earth leakage tripping for RCD's. · The device has a test button on the front to , GE Consumer & Industrial Power Protection New ElfaPlus FixwellTM Perfect connection of MCB GE Power Protection
Original
Ge rcbo BUSBAR calculation free rccb type a RCD tripping curves PBS-2 CONNECTOR mcb bimetal strip EPP60 EPP100 B-9000 R/2341/E/
Abstract: Technical data Section 9 Miniature circuit breakers Breaking capacities Tripping , (magnetic trip setting) Type C60HB MCB (type B: 3-5In) C60HC MCB (type C: 5-10In C60HD MCB (type D , 380V/415V 30,000 15,000 2,3,4P 440V 10,000 Note: For UL/CSA approved MCB's consult us. Maximum operating voltage 440V + 10% Magnetic tripping characteristics (50/60Hz) BS EN 60898 Type In , Grouping Temperature derating of MCB's Miniature circuit beakers listed in the service current tables -
Original
Merlin Gerin NS630N merlin gerin NS250N merlin gerin ns160n C801N NS250N Merlin Gerin mccb MCCB2503D4P MGB12N EN60529
Abstract: IEC/EN 60947-2 Type UL_1077 MCB Poles 1,2,3,4 Tripping Curves B,C Voltage Rating 240/415 , 240/415V Tripping Curves B,C,D Thermal Tripping 40oC Breaking Capacity 25KA Degree of Pollution , ,2,3,4P Rated Voltage 240/415V Tripping Curves B,C,D Thermal Tripping 40oC Breaking Capacity , Current Rating 10-80A Poles 1,2,3,4 P Rated Voltage 240/415V Tripping Curves C Thermal Tripping , and tripping auxiliaries control auxiliaries @ Automatic recloser auxiliaries @ Remote Schneider Electric
Original
ihp 1c manual Nsx160b DC 24V double POLE MCB Schneider IC60N C CURVE
Abstract: about the automatic tripping of the protection devices: overload or short-circuit for MCB's, earth , 23 ElfaPlus UnibisTM Technical data of MCB's Series Standards Tripping characteristics Nominal , operation is possible by uninstructed people. Tripping characteristic curves (EN/IEC 60898-1) Influence , GE Consumer & Industrial Power Protection New ElfaPlus UnibisTM Compact MCB's Saving up to , 2, 3, 4 2, 3, 4 1+N(1mod) 1+N(1mod) Add-on Tripping devices curve yes yes yes yes yes yes yes yes GE Power Protection
Original
gps1bh EPC60 FK1250H GE MCB B16 mcb C16 630 IEC 60898 category C R/2362/E/E
Abstract: short circuit rating of 16kA to BS EN 60439 High performance MCB 10kA BS 60898 15kA BS 60947-2 in , MCB 10kA BS 60898 15kA BS 60947-2 in B, C or D curve 1, 2, 3 and 4 pole Fully type tested , Type B distribution board with 250A incomer features High performance MCB 10kA BS 60898 15kA BS , or use MGBN63SPL split load kit which is supplied with a 63 amp C curve mcb Multi service B , MCB to pick up voltage. kVArh Power factor Pulsed output per kWh Note: Voltage connection Merlin Gerin
Original
merlin gerin multi 9 ihp 1c manual NS800N telemecanique contactor catalogue merlin gerin multi 9 ihp 1c schneider NS1250N Merlin Gerin NS1250N MGLV5750
Abstract: . 5 8. Association with upstream protection. 6 9. Residual current tripping curves . 7 , /66/67/71/72/73/77/78/79, 6021 08/09/10/18, 6027 42 9. RESIDUAL CURRENT TRIPPING CURVES Curve , CURVES (continued) Curve of tripping time in terms of residual current TYPE A 1 T (s) 0.5 100 , -50 W 8.5 W 14.5 W Protection against unwanted tripping : . 0.5us/100 kHz ring wave : 200A , short-circuits : . R.C.C.B. must be protected (upstream or downstream) against overloads by a m.c.b. or a Legrand
Original
IEC mcb symbols RCCB working legrand mcb c CURVE TRIPPING VOLTAGE 20 A DPX125 RCCB parts F00406EN/00
Abstract: /00 ABB Control Inc. General information Tripping curves B Gen. info. C D 5000 , contacts are also available for the S500 series MCB. Applications MCBs can be used for equipment , accessories are recognized under UL File E76126. ABB Control Inc. Time-current curves ABB miniature , applications. Instantaneous tripping occurs between approximately 3 to 5 times rated current in 50/ 60Hz , time-current curve is designed for medium magnetic start-up currents. Instantaneous tripping occurs between ABB Control
Original
IEC-898 S282-UC S261-b16 S281-UC S261-C2 S262-C10 UL1077 240VAC 480VAC 600VAC IEC-947
Abstract: Line Protection Contents Miniature Circuit Breakers (MCB , 3-12 High Performance MCB's. 3-14 , Ratings with AC in kA / cos , with DC in kA / T ms Range Tripping characteristic Rated current , / cos , with DC in kA / T ms Range Tripping characteristic Rated current S280-C S280-K,Z,D 6 , to 25000 1) In symmetrical earth-ground AC networks 2 pole MCB's (two poles in series) are ABB Automation
Original
DS651 ABB RD2 earth leakage relay RD2 earth leakage relay E251-230 S272C10 S272C6 DDA60 DS671 ESB20 ESB24 ESB40
Abstract: Shunt trip allows remote tripping of the device C1 C2 MZ 205 Under voltage release allows MCB , Protection Devices Miniature circuit breakers (MCB) Residual current circuit breakers (RCCB/ELCB) Combined MCB / RCD (RCBOs) RCD add-on blocks Moulded case circuit breakers (MCCB) Voltage surge , current devices (RCCBs/ELCBs) 17 Combined MCB/RCD (RCBO) 18 RCBO electronic 19 Earth leakage relays , domestic, commercial and industrial applications. 45 44 Technical data C curve tripping current Hager
Original
ELCB wiring diagram IEC-947-2 EARTH LEAKAGE RELAY elcb 100mA 63A tripping curve of elcb My 350 U8/84
Abstract: circuit breakers Pole     1 pole Tripping characteristic     C Application , ) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB ,   Characteristics Characteristic curves 05/05/2014 HPL-ED2014 V2.14 EN 2/4 2 Let-through energy I EATON
Original
FAZ-C20/1-NA CSA-C22 E235139 EG000020 AAB905010
Abstract: circuit breakers Pole     2 pole Tripping characteristic     C Application , ) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB ,   Characteristics Characteristic curves 05/05/2014 HPL-ED2014 V2.14 EN 2/4 2 Let-through energy I EATON
Original
FAZ-C15/2-NA
Abstract: circuit breakers Pole     2 pole Tripping characteristic     C Application , ) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB ,   Characteristics Characteristic curves 05/05/2014 HPL-ED2014 V2.14 EN 2/4 2 Let-through energy I EATON
Original
FAZ-C16/2-NA
Abstract: 5 Special features 6 Technical data 7 Tripping characteristics 8 Internal , 415 012 D0202 STOTZ selective main circuit breakers S 750 are available with tripping , selective short-circuit disconnection by downstream mcb - provide disconnection and re-connection of , requirements. If a short circuit occurs between the S 750 and the downstream mcb, another bimetal release enables the short-time delay tripping. Both the selective release and the overload release trip the ABB Automation
Original
F0007 stotz s 212 ABB STOTZ - S 212 ABB STOTZ-KONTAKT S 212 stotz 625 stotz r5402 R0002 R0001 12/09-3-ZVD
Abstract: protection Tripping curves(1) BS EN 61008-1 and IEC 61009-1 standards (immediate or selective , possible to remove the MCB from the add-on module by breaking a part · RCDs are passive (mechanical , module for MCB RCBO 63 A P+N ± ± 265 V 440 V 265 V RCD add-on module for MCB , (500 mA) Max. RCBO ± 440 V ± 440 V ± type S = selective (1) = Average curves , RCCB RCBO RCD add-on module for MCB 63 A RCD add-on module for MCB Flexible cable 25 -
Original
rcd tripping curves BS EN 61008-1 cat g 399 61009-1 rccb 4 pole 32 a 4p16A