Part Manufacturer Description PDF Samples Ordering
MC908RF2ACFAR2 Freescale Semiconductor 1.73V LVI TRIP 240NA SID ri Buy
MC908RF2AMFA Freescale Semiconductor 1.73V LVI TRIP 3UA SIDD ri Buy
MC908RF2ACFA Freescale Semiconductor 1.73V LVI TRIP 240NA SID ri Buy

mcb tripping curves

Catalog Datasheet Results Type PDF Document Tags
Abstract: overloads and fault current situations are dealt with using the magnetic tripping mode of the MCB. This , suitable MCB. In all instances, reference should be made to both the motor manufacturer's curves and , Sentry MCB features tunnel terminals of generous capacity, with 25mm2 on ratings up to and including , and feature combination heads. Retrofit kit 5567s The Sentry MCB/RCBO retrofit kit is designed for use when installing MCB/RCBOs into superceded Sentry Consumer Units. The kit contains a busbar ... Original
datasheet

3 pages,
167.88 Kb

bimetal fuse MINIATURE CIRCUIT BREAKER 6000 20A SINGLE POLE MCB HRC fuses 6A 5903s MK ln breaker SINGLE POLE MCB mcb rating 10 mcb type c 10A mcb wiring Circuit Breakers to BS EN 60898 16A hrc fuse discrimination type b mcb datasheet abstract
datasheet frame
Abstract: protection Tripping curves(1) BS EN 61008-1 and IEC 61009-1 standards (immediate or selective , possible to remove the MCB from the add-on module by breaking a part · RCDs are passive (mechanical , module for MCB RCBO 63 A P+N ± ± 265 V 440 V 265 V RCD add-on module for MCB , (500 mA) Max. RCBO ± 440 V ± 440 V ± type S = selective (1) = Average curves , RCCB RCBO RCD add-on module for MCB 63 A RCD add-on module for MCB Flexible cable 25 ... Original
datasheet

3 pages,
221.84 Kb

3POLE MCB 610091 type 2 mcb four POLE MCB 61009-1 rcbos tripping curves rccb 4 pole 32 a cat g 399 rccb BS EN 61008-1 type a RCD tripping curves type c mcb tripping curves rcd tripping curves mcb tripping curves datasheet abstract
datasheet frame
Abstract: C1 mcb closed N mcb open Under voltage release unit (MN) to ensure automatic tripping in , starting current. The required mcb rating can be determined by reference to time/current curves (consult , Miniature circuit breakers Breaking capacities Tripping characteristics Miniature circuit breaker (magnetic trip setting) Type C60HB C60HB MCB (type B: 3-5In) C60HC C60HC MCB (type C: 5-10In C60HD C60HD MCB (type D: 10-14In) C120 HB MCB C120 HC MCB C120 HD MCB NG125 NG125 N NG125 NG125 H Ratings (A) 1A to 63A ... Original
datasheet

9 pages,
46.5 Kb

rccb NG125 c60hc c60 tripping D curve sodium vapor lamp C60H 2P 10A 220v ac circuit breaker circuit-breaker C60H vigi C60 c60h tripping curves 380V 415v motor NS400H c60hc c1 C60HB C60HC C60HB abstract
datasheet frame
Abstract: Derating. 5 8. Association with upstream protection. 6 9. Residual current tripping curves . 7 , /66/67/71/72/73/77/78/79, 6021 08/09/10/18, 6027 42 9. RESIDUAL CURRENT TRIPPING CURVES Curve , CURVES (continued) Curve of tripping time in terms of residual current TYPE A 1 T (s) 0.5 100 , -50 W 8.5 W 14.5 W Protection against unwanted tripping : . 0.5µs/100 kHz ring wave : 200A , short-circuits : . R.C.C.B. must be protected (upstream or downstream) against overloads by a m.c.b. or a ... Original
datasheet

9 pages,
294.9 Kb

RCCB 30MA rccb 61008-1 RCCB working type c mcb tripping curves IEC mcb symbols mcb tripping curves datasheet abstract
datasheet frame
Abstract: Tripping characteristic curves (EN/IEC 60898-1) Magnetic release An electromagnet with plunger ensures , Technical data - MCB's Tripping current variations 60Hz 1 100Hz 1.1 200Hz 1.2 300Hz 1.4 400Hz 1.5 , the MCB can operate without unwanted tripping. Calculation The correction factor K=0.7, for use in an , short-circuit for MCB's, earth leakage tripping for RCD's. · The device has a test button on the front to , GE Consumer & Industrial Power Protection New ElfaPlus FixwellTM Perfect connection of MCB ... Original
datasheet

31 pages,
6327.73 Kb

type c mcb tripping curves type a RCD tripping curves PBS-2 CONNECTOR mcb bimetal strip Ge rcbo BUSBAR calculation free mcb tripping curves MCB ENERGY LET THROUGH datasheet abstract
datasheet frame
Abstract: 5 Special features 6 Technical data 7 Tripping characteristics 8 Internal , 415 012 D0202 D0202 STOTZ selective main circuit breakers S 750 are available with tripping , selective short-circuit disconnection by downstream mcb - provide disconnection and re-connection of , requirements. If a short circuit occurs between the S 750 and the downstream mcb, another bimetal release enables the short-time delay tripping. Both the selective release and the overload release trip the ... Original
datasheet

15 pages,
728.39 Kb

F0003 bimetal temperature control main distribution frame F0007 R3252 ABB MCB type c mcb tripping curves din vde 0641 part 11 ABB STOTZ-KONTAKT S 211 3 pole circuit breaker ABB vde 0636 ABB Main Circuit breaker MCB ENERGY LET THROUGH datasheet abstract
datasheet frame
Abstract: 6kA MCB's AD MCB's 6kA Type B Single Pole Other MCB's ALB061 ALB061 side view AD MCB's 6kA Type B AL and ML MCB's 6kA Type B, C and D Ref No. Rating Cable Size Amp Type B Type , accept the AH30 or AM100 AM100 pod's. · For pod requirements refer to standard ALB/MLB range of MCB's or , modules (Grey) Note: RCBO pods can be fitted to all single pole MCB's except AD type. Relays Ref , `pods' to BSEN 61009-2 when fitted to a single pole BSEN 60898 MCB from Eaton MEM MEMERA ASN100 ASN100 ... Original
datasheet

16 pages,
1168.66 Kb

DC 12V 25A SINGLE POLE MCB A16UE DC 12V 20A SINGLE POLE MCB MCB type Contactor 3 Phase MCL116 RCCB working SCHEMATIC 1000w power amp ALB101 AA204 MINIATURE CIRCUIT BREAKER 6 amp 230V bs 1361 ASN100R datasheet abstract
datasheet frame
Abstract: C1 mcb closed N mcb open Under voltage release unit (MN) to ensure automatic tripping in , Technical data Section 9 Miniature circuit breakers Breaking capacities Tripping , (magnetic trip setting) Type C60HB C60HB MCB (type B: 3-5In) C60HC C60HC MCB (type C: 5-10In C60HD C60HD MCB (type D , /415V /415V 30,000 15,000 2,3,4P 440V 10,000 Note: For UL/CSA approved MCB's consult us. Maximum operating voltage 440V + 10% Magnetic tripping characteristics (50/60Hz) BS EN 60898 Type In min. B ... Original
datasheet

25 pages,
283.61 Kb

MERLIN GERIN multi 9 IHP 4 C NS100N NS160N merlin gerin rcd merlin gerin rcbo CIRCUIT BREAKER NS100 merlin gerin C60 multi 9 rcbo MERLIN GERIN 800A MCCB merlin gerin NS100N STR22SE C801N MERLIN GERIN NS630N datasheet abstract
datasheet frame
Abstract: MCB and fuse. British standards Rated voltage (single pole) Tripping characteristics Short , MAIN SWITCH CAT REF MCB WAYS 40A 63A 100A 100A 100A 100A 100A 2 2 5 8 11 14 19 CAT REF 4 NH Insulated Range MS RATING RCD RATING MCB WAYS NHRS204/40 NHRS204/40 NHRS204/63 NHRS204/63 , NH1104 NH1104+3 MS RATING MCB WAYS NO OF MODULES 100A 100A 100A 100A 5 8 8 11 3 3 6 3 RCD MAIN ISOLATOR WITH DIN RAIL ACCESSORY SECTION CAT REF RCD RATING MCB WAYS NO OF MODULES ... Original
datasheet

52 pages,
2300.03 Kb

BSEN 60898 nh00 200A fuse 20A SINGLE POLE MCB IEC 60947-2 circuit breaker max zs NHRSX9806 NHRS504 MSTU6011S NHSW3100 NHRS1904 mcb technical detail NHTPSF20 SINGLE POLE MCB Wylex 604 datasheet abstract
datasheet frame
Abstract: Line Protection Contents Miniature Circuit Breakers (MCB , 3-12 High Performance MCB's. 3-14 , , IEC 898 Ratings with AC in kA / cos , with DC in kA / T ms Range Tripping characteristic Rated , / cos , with DC in kA / T ms Range Tripping characteristic Rated current S280-C S280-C S280-K S280-K,Z,D 6 , to 25000 1) In symmetrical earth-ground AC networks 2 pole MCB's (two poles in series) are ... Original
datasheet

44 pages,
3170.35 Kb

ABB f364 ABB SMISSLINE S282UC-K20 S282UCK4 S273-K32 S951N E251-24 S282-K16 S272-K10 DC 24V double POLE MCB E76126 S272C6 ABB MCCB SHUNT TRIP mcb tripping curves datasheet abstract