500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

machlett ml-892

Catalog Datasheet MFG & Type PDF Document Tags

AM MODULATOR

Abstract: air cooler supports used with types 892-R, 5699, etc. These tubes will operate with plate voltages up to 12.5 kV in , with Machlett ML-6423 Air Distributor F-17797. +At frequencies up to 15 Mc, normal cabinet ventilation , ordering for this application add the suffix "P" to the Machlett tube number. "For applications requiring longer pulse duration or higher duty factors, consult the Machlett Engineering Department. WARNING , '" ML-6423-F ST-1688 4.5M 5-64 THE MACHLETT LABORATORIES, INC. An Affiliate of Raytheon Company
-
OCR Scan
892-R AM MODULATOR air cooler machlett 6423 Raytheon Company machlett ml-892 ML-6422 ML-642 ED-29008/RI

machlett ml-892

Abstract: 892-R cmçi- ML-892 ML-892R PAGE 1 ISSUED 11-59 , filament. The ML-892 has a water-cooled anode capable of dissipating 10 kW with a moderate water flow. The , 450 cfm. Maximum ratings of 15 kVdc plate voltage and 30 kW plate input for the ML-892 and 12.5 kVdc , . Type of Cooling â'" ML-892
-
OCR Scan
machlett B 892 rs tube IB 6400 ML-892 L-892 ST1640

machlett x-ray tube

Abstract: machlett  ORDERING NOTES Refer to Machlett price list. When ordering specify â'¢ tube type â , .) f 75°C (167°F) 75°C (167°F) 165°C (329 °F) 35 lbs. (15.9 kg) tWhen using Machlett oil jacket part number F-543919 (order separately) THE MACHLETT LABORATORIES, INC., Stamford, Connecticut 06907 a , For applications requiring longer pulse duration or higher duty factors, consult the Machlett , Nominal Maximum Notes A 4.60 (116.8 ) 4.63 (117.6) 4.66 (118.4) 1 B 3.48 ( 88.4 ) 3.51 ( 89.2) 3.54
-
OCR Scan
machlett x-ray tube POWER40 ST37-2 radar tube cathode ray F-17488 F-17489 F-17397 ST-3729 SP0182

5669

Abstract: ML-5669 ML-5668 ML-5669 PAGE 1 ISSUED 2-60 M ML-5668 ML-5669 DESCRIPTION & RATINGS DESCRIPTION The ML-5668 and ML-5669 are three-electrode tubes The ML-5668 supersedes the type 892 triode for indus-designed specifically to meet the severe conditions of radio- trial applications and will replace it with minor equipment frequency heating services. The cathodes of these tubes are modifications. The , ± .001" DIA. B.C. AT ANGLES OF 90°± 10* DIMENSIONS â'" ML-5668 DIMENSIONS â'" ML-5669 MACHLETT
-
OCR Scan
5669 Scans-0017481 la 5668 ST-1687

MA 7815

Abstract: 7815R The Machlett Laboratories, Inc. â'¢ 1063 Hope Street Stamford, Conn. 06907 â'¢ Tel. 203-348-7511 â'¢ TWX 203-327-2496 ISSUED 3-67 UHF Planar Triodes CW, Plate or Grid Pulsed Phormat Cathode , .17 W fFor applications requiring longer pulse duration or higher duty factors, consult the Machlett , and before installing tubes in equipment, refer to the general information given in the Machlett , . THE MACHLETT LABORATORIES, INC. A SUBSIDIARY OF RAYTHEON COMPANY Printed in U.S.A. ST-2329 5M 3-67
-
OCR Scan
ML-7815R MA 7815 7815R ML7815 7815 ML7815r 7815 to-3 ML-7815/3CPN10A5 ML-7815/ 3CPN10A5

machlett

Abstract: Scans-0017378 inherently a part of Machlett Laboratories, Inc., since 1897. All parts are thoroughly processed by special Machlett techniques, which prevent contamination and assure complete and permanent outgassing. The tubes , characterize the Machlett line of high- and super-voltage x-ray tubes. GENERAL CHARACTERISTICS Electrical
-
OCR Scan
ML-298A ML-298B Scans-0017378

machlett

Abstract: air cooler -6425-F .50 lbs. â'¢When used with Machlett ML-6425 Air Distributor F-17797. +At frequencies up to 15 Mc , JWhen ordering for this application add the suffix "P" to the Machlett tube number. "For applications requiring longer pulse duration or higher duty factors, consult the Machlett Engineering Department , ‡ MACHLETT AIR DISTRIBUTOR Fâ'"17797 A-I30S3/RZ COOLING CHARACTERISTICS â'" ML-6424 WATER COOUNG , THE MACHLETT LABORATORIES, INC. An Affiliate of Raytheon Company SPRINGDALE (M CONNECTICUT Printed
-
OCR Scan
ML-6425-F ST-1689 6425F 2s008 ei 306 20 64 st 1689 KW operation amplifier 5I82/R4 ED-2S008/RI

ML-8536

Abstract: machlett The Machlett Laboratories, Inc. â'¢ 1063 Hope Street Stamford, Conn. 06907 â'¢ Tel. 203-348-7511 , . +For applications requiring longer pulse duration or higher duty factors, consult the Machlett , in the Machlett publication entitled Application Notes, UHF Tubes â'"General. ML-8536 ML-8537 PAGE , with the gage chucked on the measurement reference axis. 2. See outline. Machlett gage No. S-L5 , . RAYTHEON THE MACHLETT LABORATORIES, INC. A SUBSIDIARY OF RAYTHEON COMPANY Printed in U.S.A. ST-2041 5M
-
OCR Scan
1542 d 1542d machlett ML8536 ML853 ml8536 ml 8536

ML-8538

Abstract: ML-8539 data in final equipment designs, consult Machlett for possible revisions. GENERAL CHARACTERISTICS , applications requiring longer pulse duration or higher duty factors, consult the Machlett Engineering , exceed .020 inch. 4. See outline. Machlett gage No. S-L5. Details will be supplied upon request. 5. See , . THE MACHLETT LABORATORIES, INC. An Affiliate of Raytheon Company ST 2023 4.5M 5 64
-
OCR Scan
ML-8538 ML-8539 8539 ML8538 mix5 8s38

machlett x-ray tube

Abstract: machlett The Machlett Laboratories, Inc. 1063 Hope Street â'¢ Stamford, Conn. 06907 Tel. 203-348-7511 â , construction which characterize Machlett high-vacuum rectifiers for high power-level applications. These , .Optional Mounting Socket, Machlett Part No , 2.81 2.88 2.95 L 2.21 2.28 2.35 NOTE: 1. Cathode base fits Machlett mounting socket part P-8835. RAYTHEON THE MACHLETT LABORATORIES, INC. A SUBSIDIARY OF RAYTHEON COMPANY Printed in U.S.A. ST-830 5M
-
OCR Scan
8094 B094 xray tube EF120 machlett x-ray ML-8094/199

ML-8741

Abstract: Raytheon Company The Machlett Laboratories, Inc. 1063 Hope Street â'¢ Stamford, Conn. 06907 Tel. 203-348-7511 â , . Before using these data in final equipment designs, consult Machlett for possible revisions. GENERAL , duty factors, consult the Machlett Engineering Department. Grid-Pulsed or Plate-Pulsed RF Oscillator or , , refer to the general information given in the Machlett publication entitled Application Notes. UHF Tubes , then measured with the gage chucked on the measurement reference axis. 2. See outline. Machlett gage No
-
OCR Scan
ML-8741 ED-28367/R4 ST-2294

6-10 Ghz RF Power 100w amplifier

Abstract: machlett The Machlett Laboratories, Inc. â'¢ 1063 Hope Street Stamford, Conn. 06907 â'¢ Tel. 203-348-7511 , criteria. Before consult Machlett for possible revisions. GENERAL CHARACTERISTICS Electrical Heater , . ffFor applications requiring longer pulse duration or higher duty factors, consult the Machlett , the Machlett publication entitled Application Notes, UHF Tubes â'"General. ML-8534 ML-8535 PAGE 3 , measurement reference axis. 2. See outline. Machlett gage No. S-L5. Details will be supplied upon request. 3
-
OCR Scan
6-10 Ghz RF Power 100w amplifier ST-2040

APPLICATIONS OF 8038

Abstract: MAX 8038 dielectric fluids. For details, consult Machlett. â'¢125 A60 A60 kV *125 65 65 kv â'" 1500 â'" 1500 â , longer pulse duration or higher duty factors, consult the Machlett Engineering Department. fAt filament , IN INCHES DIMENSIONS â'"ML-8040 DIMENSIONSâ'" ML-8041 THE MACHLETT LABORATORIES, INC. An Affiliate
-
OCR Scan
APPLICATIONS OF 8038 MAX 8038 28389 8038 APPLICATIONS ML-8038 03IDIA ED-2B387/R2 031DIA ED-28388/RI ED-28389/RI

M 8906

Abstract: 7815R -8907 .63 g § For cooling data refer to Machlett Application Notes, UHF Tubes â'" General ML-8906 ML , longer pulse duration or higher duty factor, consult the Machlett Engineering Department. Typical , the Machlett Engineering Department CHARACTERISTIC RANGE VALUES FOR EQUIPMENT DESIGN Filament , tubes in equipment, refer to the general information given in the Machlett publications entitled , with respect to the heater contact surface will not exceed .012 inch. THE MACHLETT LABORATORIES, INC
-
OCR Scan
M 8906 ic 7815 ic la 7698 ic 7698 ML-7698 8906 ic ML-8907 ML-8906/AL 27347/R3 ST-2744

machlett

Abstract: machlett x-ray tube Machlett Laboratories, Inc., since 1897. All parts are thoroughly processed by special Machlett techniques , straight-line, high-voltage process assuring the same high standards as characterize the Machlett line of , -933 A-13010 FILAMENT VOLTAGE I:1 LAMENT CHARACTERISTICS Dimensionsâ'"ML-222A THE MACHLETT
-
OCR Scan
A-13011 Scans-0017364 222A A-13010 x-ray tube ML-22 ED-933 5T-914

ML-8741

Abstract: machlett The Machlett Laboratories, Inc. 1063 Hope Street â'¢ Stamford, Conn. 06907 Tel. 203-348-7511 â , . Before using these data in final equipment designs, consult Machlett for possible revisions. GENERAL , duty factors, consult the Machlett Engineering Department. CHARACTERISTIC RANGE VALUES FOR EQUIPMENT , equipment, refer to the general information given in the Machlett publication entitled Application Notes , RAYTHEON THE MACHLETT LABORATORIES, INC. A SUBSIDIARY OF RAYTHEON COMPANY Printed in U.S.A. ST-2294 2.5M
-
OCR Scan
1626 power Triode 8741 55MMC

parker valves

Abstract: Raytheon Company The Machlett Laboratories, Inc. 1063 Hope Street â'¢ Stamford, Conn. 06907 Tel. 203-348-7511 â'¢ TWX 710-474-1744 ISSUED 2-71 General Purpose Triodes 240 kW CW DESCRIPTION The ML-8795 and ML , Machlett mounting socket, part no. F-12527. 4. Water inlet and outlet orifices in anode water jacket base , . 5. O-ring gasket, Machlett part P-25946, supplied with tube. 6. Tube to be supported in equipment , -8796 PAGE 4 PLATE VOLTAGE â'"KILOVOLTS ED-538004 I THE MACHLETT LABORATORIES, INC. A SUBSIDIARY OF
-
OCR Scan
parker valves NATIONAL ELECTRONIC TUBE company thyratron 8795 ML-8796 ST-2610

813 electron tube

Abstract: ML-6442 supply. For specific applications above 500 Mc, consult the Machlett Engineering Department for optimum , .6.0 Volts * For applications above a duty factor of 0.001, contact the Mach-lett Engineering , equipment, refer to the general information given in the Machlett publication entitled Application Notes , 13.89 AZ 1.000 25.40 AD 1.109 28.17 AE .438 11.13 AF .453 11.51 THE MACHLETT
-
OCR Scan
ML-6442 813 electron tube 5000-microsecond amplifier marking 365 w shape heater machlett triode

ML-220C

Abstract: 220CA Machlett Laboratories, Inc., since 1897. All parts are thoroughly processed by special Machlett techniques , straight-line, high-voltage process assuring the same high standards as characterize the Machlett line of
-
OCR Scan
ML-220C 220CA machlett x-ray tube datasheet machlett laboratories tubes ML-220CA MU220C

magnetron modulator design

Abstract: ML8464 and test criteria. Before using these data in final equipment designs, consult Machlett for possible , Machlett Engineering Department. WARNING: Operation of this tube might produce x-rays. Adequate rayproof , -2, (S) inches deep. THE MACHLETT LABORATORIES, INC. An Affiliate of Roytheon Company ST-2020 4.5M
-
OCR Scan
ML-8464 magnetron modulator design ML8464 magnetron ns radar magnetron 65 kw magnetron 60 kw 2B37V