500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
HSP45116DB-EVAL Intersil Corporation Numerically Controlled Oscillator/Modulator; ; Package: 160-Eval Board visit Intersil
SN74ALS528D Texas Instruments Fuse-Programmable Identity Comparators 16-SOIC 0 to 70 visit Texas Instruments
LM8502TMX/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85 visit Texas Instruments
LM8502TME/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85 visit Texas Instruments Buy

fuse L350-160

Catalog Datasheet MFG & Type PDF Document Tags

fuse L350-160

Abstract: E1000-55 International Rectifier Semiconductors Fuse Links High Speed Fuse Links REFERENCE TABLE I«ms Irms Pre-Arcino Total-lJ, Total-l2t Outline Stock 25 "C 45 "C Pu(m.,) I2t at 455V at700V Drawing No. Amps Amps Watts Amp Sec Amp Sec Amp Sec No. Type RMS Rated Current 7 to 17S Amps. VBMS 2S0V , -125 30674G 125 109 14 1350 7800* 15000" L350-160 3067SE 160 140 17 2400 14000* 26000" L350-175 30676C 175 160 18 4000 23000* 42000* ¡v 29 RMS Rated Current t to 55 Amps. Vâ'žMs 700V E1000-8 19871E 8
-
OCR Scan
L350-10 L350-16 L350-25 L350-30 L350-35 L350-100 fuse L350-160 E1000-55 E1000-40 EE1000-110 L350-125 L350-7 30665R 306MG L350-12 3M67E

fuse L350-160

Abstract: Inrush Current Conditions Min Vo,Io nom Vo,Io nom External Fuse(recommend) http , .(230Vac) VDE/UL/CCC E-mail:yds.tech@msa.hinet.net E-mail:yds@yds.com.tw FUSE 1.0A/250V (Slow blow , Recommended Application Circuit L Vout+ VACin(L) Fuse 75 60 50 47uF N Nature Convection 50 0.47uF Load Vout- VACin(N) NOTE: 1. Fuse: 1A/250V (Slow blow) 2. Ripple &
Yuan Dean Scientific
Original
264VAC GA5A-S03 GA5A-S05 GA5A-S06 GA5A-S07 GA5A-S08

Wiring Diagram kraus naimer ca10

Abstract: CA20 kraus naimer wiring diagram for 2 position t Consumer Units & Distribution Boards. . . . . . . DIN Standard Fuses & Fuseholders . . . . . . . . . Fuse Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Links . . . . . . . . . . , + Page 2228 2239 2229 2207 2228 2226 2236 2216 2189 2230 2230 2208 Fuse Characteristics Each fuselink is , breaking, or rupture, capacity. Usually manufactured with ceramic fuse bodies. Fuse Sizes 11/4" x 1/4 , electrical and physical characteristics that is generally not possible with standard fuse technologies. This
Kraus & Naimer
Original
Wiring Diagram kraus naimer ca10 CA20 kraus naimer wiring diagram for 2 position t ca10 rotary switch Wiring Diagram kraus naimer ca20b CA10 A300 kraus naimer CA 10 B-1930 D-76189 D-76231 N-0508 S-126

Wiring Diagram kraus naimer ca10

Abstract: CA10 A300 Bay-O-Net Fuse Combinationsa 45 1.60 50 C08 1.60 30 C06 1.60 30 C04 1.60 30 75 1.60 80 C10 , Fuse Combinationsb 45 1.60 80 C08 1.60 30 C05 1.60 30 C03 1.60 30 75 1.60 125 C10 1.83 , Current Sensing Bay-O-Net Fuse Combinationsa 45 1.60 30 C04 1.60 30 C04 75 1.60 30 C04 1.60 , Element Bay-O-Net Fuse Combinationsb 45 1.60 30 C03 1.60 30 C03 75 1.60 30 C03 1.60 30 C03 , ) ELSP and Current Sensing Bay-O-Net Fuse Combinationsa 45 1.60 30 C04 1.60 30 75 1.60 30 C04
Kraus & Naimer
Original
kraus and naimer Ca4 kraus naimer ca10 star delta wiring diagram motor start y KRAUS NAIMER CA10 A007-624 CA20 kraus it naimer Ca20b FIN-01530

merlin gerin fuse

Abstract: IR 2544S Gears & Fuse Gears Gears & Fuse Gears IEC General Purpose Fuses NH Fuses Ceramic Bases Sizes 00 , high-contact pressure springs · For size 4, pressure is assured by a special nut. Size 1 fuse bases accept fuse sizes 0 and 1. Size 2 fuse bases accept fuses size 1 and 2. Size 3 fuse bases accept fuses size 1, 2 and 3. Type EP fuse bases with square contacts. Type PP fuse bases with clip contacts. 690V Ceramic fuse bases for NH Fuse-links · · · · · Ceramic insulating bases Silver plated contacts High spring
Element14 Catalog
Original
merlin gerin fuse IR 2544S MICRO FUSE-LINKS 1608 TYPE HRC fuse gg GEC MGI1252 THERMAL Fuse m20 tf 115 c MGAN12 400/415V MGBN16
Abstract: a NH LOW VOLTAGE FUSE SYSTEM NH LOW VOLTAGE FUSE SYSTEM NH DIN Low Voltage Fuse System , ) Cooper Bussmann low voltage NH DIN fuse links are manufactured in the following sizes, current ratings , 1600A The Bussmann NH DIN low voltage fuse links are available at 400Vac, 500Vac and 690Vac and includes fuse links to DIN VDE 0636. All products are manufactured to the dimensional requirements of DIN 43 620. Approvals The NH DIN low voltage fuse system offered by Cooper Bussmann includes fuse links EATON
Original
S240-50-1 CP1101 CP0901 W240-10006 W240-11018 B240-11013

DIN43620

Abstract: S219804 Rating (kV) Fuse Diameter (in) Current Rating (Amps) 60 80 2.2 8.3 100 130 160 130 3.3 160 200 250 60 2.2 15.5 3.3 80 100 130 160 200 Fuse Catalog Number HTFX230030 HTFX230040 HTFX230050 HTFX230065 HTFX230080 , 65 80 80 100 130 160 65 80 100 125 130 150 160 200 200 250 NOTES: 1. To order a fuse having a blown , PROTECTION AND CONTROL Trans-GuardTM FX Fuses The Trans-GuardTM FX full-range currentlimiting fuse provides both overload and fault current protection for distribution equipment in a single fuse body. As a
Ferraz Shawmut
Original
DIN43620 IEC269-2-1 NFC63210 Z217211 P218237 S219804 W223004 FG137 DIN0636 00-EB

IEC60947-3

Abstract: 315NH2G high-contact pressure springs â'¢ For size 4, pressure is assured by a special nut. Size 1 fuse bases accept fuse sizes 0 and 1. Size 2 fuse bases accept fuses size 1 and 2. Size 3 fuse bases accept fuses size 1, 2 and 3. Type EP fuse bases with square contacts. Type PP fuse bases with clip contacts. 690V Ceramic fuse bases for NH Fuse-links â'¢ â'¢ â'¢ â'¢ â'¢ Ceramic insulating bases Silver , , 63211, 60200, VDE DIN0636 Single-Pole Fuse Bases Rated Prev. Size Current Ref. (A) 00-E 00
Bussmann
Original
IEC60947-3 315NH2G IEC-60269 160NH1M 500NH3G-690 400NH2G-690 000/C00 IP-20

HTFX240030

Abstract: PG-PC-H-0307 Body Amp Size Ferrule 40 x 48mm 63 100 40 48mm 160 40 xx48mm 200 250 â'˜Jâ'™ Type HRC Fuse , 5 - FUSEGEAR Fuse Fittings & Bases Safeclip RS Fittings Series 7 J Type Bases Porcelain , Form 101 Safeclip Fittings Industrial Fuse Links BS88 Clip-in BS88 Bolt-in 415 - 660V DIN , Fuse Links & Fittings BS88 J Type 415V Series 7 Fittings Porcelain Overhead Fittings Outdoor Disconnects J Type Service Fitting Ferrule Fuses Fuse Links 153 198 Photovoltaic System
Thomas & Betts
Original
HTFX240006 HTFX240025 HTFX240030 HTFX250010 HTFX250040 PG-PC-H-0307 PG-PC-H HTFX241040 HTFX320080 HTFX320100 HTFX320125 HTFX320150 HTFX320200

nfc63210

Abstract: temperature of 20°C. Striker DE55761 Ø 81 Fuse curve 7.2 kV 200 A 55 160 A 2 1000 8 , 50 31.5 31.5 40 25 160 63 100 100 63 63 Soléfuse fuses UTE standard for , from 3.6 kV to 36 kV Contents Applications 2 Fuse range selection 2 Main characteristics 3 Fusarc CF, Soléfuse, Tépéfuse, MGK Construction 5 MV limiting fuses with thermal , characteristics 8 Fuse and limitation curves 10 Soléfuse References and characteristics 12 TÃ
Ferraz Shawmut
Original
EB001 E217722 C218755 R219274 D222482 D201851

8DB0056-001

Abstract: TAG 203 350 Switches Fuse size Frame size CD 160 A 00 3 Direct operation switch (switch body only) No. of , FUSERBLOC CD Compact Design 20 to 1 250 A LL Fuse combination switches Functions , FUSERBLOC are manually operated multipolar fuse combination switches. They break or switch off on load and , · Fully visualised breaking · Double break by phase (top and bottom of fuse) · Protection against overcurrent by fuse circuit-breakers (gG, aM, UR, BS88) with high breaking capacity (100 kA eff.) · IP2
IPD Industrial Products
Original
8DB0056-001 TAG 203 350 RS63H neutral link RS20HWH TLU800 TLU 315 500/660V 500/690V BS2692-1975 AS1033-2 IEC282-1 K81PEX

33kv transformer

Abstract: series) 220 (2 conducting paths in series and for mounted fuse monitoring) 00/160 50 15 1/250 , A 160 100 250 250 400 400 630 630 Fuse switch disconnectors 3NJ ­ the highlights , 06­09 3NP fuse switch disconnectors: For 100 % protection against overload and short-circuit , . . Pages 10­11 3NJ fuse in-line switch disconnectors ­ the strong combination for switching loads and isolating with integrated low-voltage HRC fuses. . . . . . . . . Pages 12­13 3NJ4 fuse
Schneider Electric
Original
33kv transformer AC0479EN PM103057 PM104195

socomec IEC 60947-3

Abstract: THERMAL Fuse m20 tf 115 c Circuit Protection Solutions Low Voltage Fuse Links Catalogue Low Voltage Fuse Links Catalogue Table of Contents Domestic Applications to BS1361 & BS1312 Consumer Unit Fuse Link 4 Plug Top Fuse Links 4 Industrial & Motor Applications to BS88 Offset Bolted Tags 5-7 Centre Bolted , Cut-Out Fuse Links 17 J Type Fuse Links to BS88: Part 5 Cylindrical 17 J Type Fuse Links to , NH Fuseholders for Knife Fuses 36 Dimensions for Knife fuse and Fuseholders (NH) 37 - 38
-
Original
socomec IEC 60947-3 EL11AP socomec changeover switch SOCOMEC 6723 0250 3641 4000 BAO63

IEC 60947 VDE 0660

Abstract: siemens fuse disconnectors /45 17/47 17/48 17/50 3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors , In-Line Fuse Switch Disconnectors up to 1250 A General data 1-pole switchable 3-pole switchable , Protection Devices â'" Switch Disconnectors Introduction Type 3NP 3K 3NJ4 A 160 to 630 63 to 1000 160 to 1250 V 690 690 690 â" â" â" â" â" â" â" â" â , " â" â" Fuse monitoring â'¢ With circuit breakers â" â" â" â'¢ With
Siemens
Original
IEC 60947 VDE 0660 siemens fuse disconnectors siemens 3sb1 3KM52 main switch 3LD siemens 3LD20 D-90327 E20001-A270-P307-X-7600

16GD27

Abstract: bussmann hrc fuse bs88 part 5 neutral links Solid links, handle and spare fuse storage Terminal shrouds and phase barriers Connecting accessories Conversion kits Blown fuse indicators Locking and mounting accessories 51 Dimension , 15 7.5 40 15 15 18,5 11 60 63 15 100 125 160 30 30 55 55 480 V [HP , 32 50 63 100 125 160 Accessories Terminal shrouds Extended shafts Connecting accessories Auxiliary contacts Conversion kits Fourth poles Blown fuse indicators N & PE
Cooper Bussmann
Original
16GD27 bussmann hrc fuse bs88 part 5 bussmann hrc fuse bs88 part 4 63a17 BS88 fuse NH3 630A 660/690V LV-2007

SIEMENS NH FUSE

Abstract: 3ld22 SPFJ SERIES Solar FUSE Ordering Information PART Number SPFJ 125 SPFJ 160 SPFJ 200 SPFJ 250 SPFJ 300 , POWR-GARD® Fuse Datasheet SPFJ SERIES Solar FUSE 1000 VDC · 125-450 A Specifications Voltage Rating Amperage Rating Interrupting Rating 1000 VDC 600 VAC 125, 160, 200, 250, 300, 350, 400 , ) Approvals UL 2579 Listed (File: E339112) UL 248-8, Class J (except 125, 160, 200 A) C UL (except 125, 160 , fuse available in the market. The SPFJ series is manufactured in Class J case sizes that allows for
Siemens
Original
SIEMENS NH FUSE 3ld22 siemens VDE 0660 manual siemens M20 3LD21 3LD22 3LD25 3LD27 3LD28 3NJ41

OS160GD

Abstract: 1SCA108817R1001 ,000 Amperes DC 160 Volts DC Description Class T Fuse 110 Ampere Class T Fuse 125 Ampere Class T , 0.29/0.13 600% Class T Fuse 160 Volt DC 110 to 400 Amperes 0.860" 21.84mm 1.310" 33.27mm , Fuse Blocks & Fuses CLASS T Fuse Block System · The fuse system recommended by most inverter , , satisfying ABYC/USCG requirements · For use on systems up to 160 VDC · Large stud terminals (3/8" on 5002 , Class T Fuses available Maximum Amperage Maximum Voltage Fuse Mounting Blocks Black Lexan
ABB Automation
Original
OS32GD OS63GD OS160GD OS16FD OS40FD 1SCA108817R1001 OS400D03P OS800D 1SCA108828R1001 OS32GD12P OS125GD OS35FD OS20FB

160A fuse curve

Abstract: Bussmann® NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 500V AC, 10 to , . Description: Packaging: All fuse links are packed in 3's. Technical Data: Rated Voltage: Rated , SYMBOL: (amp)NHG(Size)B HRC FUSE LINKS CLASS OF OPERATION gL/gG 500V AC 10 to 630 AMPS SIZES 000 to 3 A square bodied range of industrial fuse links for a wide variety of applications. 500V AC , Fuse Links NH Class of Operation gL/gG, 500V AC, 10 to 100 Amps Sizes 000 Time Current
Littelfuse
Original
160A fuse curve
Showing first 20 results.