500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

explosion proof

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: JUPITER 8811 ADF Series Description Explosion proof connectors offering a high robustness and resistance to marine corrosion - scoop proof insert - screw locking system Explosion proof certification by , standard. Ex - Explosion Proof. "d" Symbol designating protection for flameproof enclosure. This enclosure , Explosion Proof. ia I Instrinsically safe, suitable for zones 0, 1, and 2. Gas Group I, (representative gas , for hazardous areas ("d" explosion proof type of protection) JUPITER 8811 ADF Ordering ... FCI
Original
datasheet

5 pages,
507.35 Kb

JUPITER MS series jupiter explosion proof endbell JUPITER M 14 JUPITER CONNECTORS JUPITER connector JUPITER e series connector MS JUPITER e series connector TEXT
datasheet frame
Abstract: Hazardous Location & Pneumatic Switches Explosion Proof Ex Range Specifications NRTL/C , switch. 16-2 Hazardous Location & Pneumatic Switches Explosion Proof Ex Range Product Selection Switch Description Ex Trojan 5 Explosion proof tongue operated safety interlock switch. Ex Ferrogard GS2 Explosion proof magnetically actuated, noncontact safety interlock switches , -H02046 -H02046 440N-H02086 440N-H02086 10 (32.8) 1 N.C. 440N-H02087 440N-H02087 1 N.C. & 1 N.O. Ex Rotacam Explosion proof ... Original
datasheet

2 pages,
55.38 Kb

trojan 5 440k 440E-H13069 440EH13069 GuardMaster safety switch Ferrogard ferrogard gs2 GuardMaster 440K-H11160 GuardMaster telescopic 440K-H11145 440K-H11161 CP15-EX GuardMaster CENTURION GuardMaster trojan 5 EX GuardMaster TIME DELAY BOLT GuardMaster trojan 5 440EH13046 GuardMaster lifeline 4 GuardMaster trojan 5 6 GuardMaster Catalogue SAFETY SWITCH TEXT
datasheet frame
Abstract: Explosion Proof Filters Ceramic Pi Filter for Explosion Proof Equipment According to EN 50 020 , ) Coating ø0.8 (20.32) tinned Cu 4.0 (101.6) Explosion Proof Filters Ground Typical Electrical , Explosion Proof Applications 100 90 Part Numbers Insertion Loss (dB) 80 70 Solder Mount and Bushing , Explosion Proof Filters for Industrial Processing Equipment Ceramic Pi Filter for Explosion Proof Equipment , Insertion Loss (dB) Pi Insertion Loss Typical Explosion Proof Applications 100 90 80 70 60 50 40 30 20 ... Spectrum Control
Original
datasheet

2 pages,
80.9 Kb

Feed-Thru Filters type pi TEXT
datasheet frame
Abstract: RDE5 Differential pressure switch, explosion proof for high static pressure Main Features , control and alarm F „„ High static pressure „„ Explosion proof Hazardous areas 1, 2, 21, 22 , Housing Type RA80, explosion proof, flameproof Alumunium epoxy painted. Captive stainless steel , Data sheet A32.23 Page 1 / 5 RDE5 Differential pressure switch, explosion proof for high , A32.23 Page 2 / 5 RDE5 Differential pressure switch, explosion proof for high static ... Baumer
Original
datasheet

5 pages,
784.08 Kb

TEXT
datasheet frame
Abstract: RDE6 Differential pressure switch, explosion proof for variable static pressure Main , on the setpoint No „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications „„ Power , ± 5% FS Housing Type RA80, explosion proof, flameproof Alumunium epoxy painted. Captive , www.baumer.com Data sheet A32.43 Page 1 / 5 RDE6 Differential pressure switch, explosion proof for , A32.43 Page 2 / 5 RDE6 Differential pressure switch, explosion proof for variable static ... Baumer
Original
datasheet

5 pages,
782.79 Kb

TEXT
datasheet frame
Abstract: R ussellstolf Max-Gard 30A Explosion Proof Receptacle Max-Gard 30A Explosion Proof Receptacles meet applications for safe high current power in Explosion Proof Class I & II hazardous environments. They also support newer intrinsically safe circuit designs and carry full XP 30A, 480 VAC Load Breaking , utilizing standard rated or Explosion Proof plugs. Benefits: Fast, Easy Installation with Factory , , FL 34609 · (352)799-4800 · Fax (352)799-9537 ThomasÊBetts Max-Gard 30A Explosion Proof ... OCR Scan
datasheet

2 pages,
69.03 Kb

TEXT
datasheet frame
Abstract: RTNE3 - RTAE3 Industrial temperature switch, direct mounting explosion proof Main Features , control and alarm F „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications „„ Power , (316L) Internal. Accuracy on reading ± 5% FS Type RA80, explosion proof, flameproof Alumunium epoxy , mounting explosion proof Principle A vapour filled flexible sensing element actuates a microswitch by , RTNE3 - RTAE3 Industrial temperature switch, direct mounting explosion proof Micro switches ... Baumer
Original
datasheet

5 pages,
815.45 Kb

TEXT
datasheet frame
Abstract: RTNE4 - RTAE4 Industrial temperature switch with capillary, explosion proof Main Features , control and alarm F „„ Explosion proof Hazardous areas 1, 2, 21, 22 Applications „„ Power , reading ± 5% FS Housing Type RA80, explosion proof, flameproof Alumunium epoxy painted. Captive , .15 Page 1 / 6 RTNE4 - RTAE4 Industrial temperature switch with capillary, explosion proof , temperature switch with capillary, explosion proof Micro switches characteristics Switch code N (T ... Baumer
Original
datasheet

6 pages,
964.49 Kb

TEXT
datasheet frame
Abstract: RPPE4 Industrial pressure switch, explosion proof with high overpressure resistance Main , for control and alarm F „„ verpressure up to 100 bar O „„ Explosion proof Hazardous , : Viton® Internal. Accuracy on reading ± 5% FS Type RA80, explosion proof, flameproof Alumunium epoxy , RPPE4 Industrial pressure switch, explosion proof with high overpressure resistance Principle A , A32.10 Page 2 / 5 RPPE4 Industrial pressure switch, explosion proof with high overpressure ... Baumer
Original
datasheet

5 pages,
720.4 Kb

TEXT
datasheet frame
Abstract: RPPE6 - RPPE8 Industrial pressure switch, explosion proof with high overpressure resistance , dead band for control and alarm F „„ verpressure up to 100 bar O „„ Explosion proof , RA80, explosion proof, flameproof Alumunium epoxy painted. Captive stainless steel screws Mounting , RPPE8 Industrial pressure switch, explosion proof with high overpressure resistance Principle A , A32.11 Page 2 / 5 RPPE6 - RPPE8 Industrial pressure switch, explosion proof with high ... Baumer
Original
datasheet

5 pages,
707.86 Kb

TEXT
datasheet frame

Archived Files

Abstract Saved from Date Saved File Size Type Download
• Push mount into explosion proof housing EPW3. 508B-2 508B-2: 1/2" 508B-1 508B-1 in explosion proof housing EPW3 $12 508B-1 508B-1 in explosion proof housing EPW2 $12
/datasheets/files/omega/newport/products/sgcndtrn/508b_2.htm
Omega 25/04/2000 21.39 Kb HTM 508b_2.htm
:FEATURES 1.No starting contacts to pit or wear. 2.May be directly substituted for start switches without redesigning motor. 3.Encapsulated construction. 4.Acoustically and electrically noise free. 5.Vibration and shock resistant. 6.Long operating life. 7.Ideal for explosion proof motor applications. 8.Quick connect terminations. 9.Many kinds of relays can be replaced by one POSISTOR(R) :APPLICATIONS Refrigerator motor/Air conditioner motor/Motor for
/datasheets/files/murata/products/data/a13x/r0601f01.txt
Murata 28/09/1996 0.56 Kb TXT r0601f01.txt
No abstract text available
/download/11800534-700140ZC/n.xls
Sager 16/05/1996 3.27 Kb XLS n.xls
and shock resistant. 6. Long operating life. 7. deal for explosion proof motor applications. 8.
/datasheets/files/murata/products/data/a11x/r0601f01.txt
Murata 26/07/2000 1.26 Kb TXT r0601f01.txt
thermowell heads, or in explosion proof housings.
/datasheets/files/omega/newport/litertur/index.htm
Omega 31/03/2000 14.47 Kb HTM index.htm
power and versatility that are necessary to cope with the growing applications explosion in today's one-year target, and there are already over 500 native applications available - proof of the widespread and
/datasheets/files/motorola/design-n/sps/powerpc/library/press_re/cebit_re.htm
Motorola 25/11/1996 10.95 Kb HTM cebit_re.htm
FIBER-OPTIC CONNECTIVITY IN THE MAINTENANCE ENVIRONMENT FIBER-OPTIC CONNECTORS IN THE MAINTENANCE ENVIRONMENT Spending thirty years of my career in the telecommunications industry has provided me an opportunity to witness first-hand, a technology explosion that is almost beyond belief. As an Outside Plant Engineer during the 1960's, it was not unusual to be involved not designed to be pull proof which meant that it could optically disconnect when the patchcord was
/datasheets/files/molex/docs/wcd00004/wcd00476.htm
Molex 30/06/1999 21.56 Kb HTM wcd00476.htm
No abstract text available
/datasheets/files/linear/lview3/parts-v1.edb
Linear 08/10/1998 5000.33 Kb EDB parts-v1.edb
No abstract text available
/datasheets/files/linear/lview3/parts.ebd
Linear 08/10/1998 5000.33 Kb EBD parts.ebd
No abstract text available
/datasheets/files/linear/lview4/parts.edb
Linear 15/02/2000 7168.02 Kb EDB parts.edb