Part Manufacturer Description Datasheet BUY
AMBIENTLIGHTADAPTIVELED-REF Texas Instruments Ambient Light Adaptive LED Driver visit Texas Instruments
COMBOLED Texas Instruments TPS92020 Resonant-Switching Driver Controller for LED Lighting visit Texas Instruments
ISL29044AIROMZ-T7 Intersil Corporation Low Power Ambient Light and Proximity Sensor with Internal IR-LED and Digital Output; ODFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL29102IROZ-T7 Intersil Corporation Low Power Ambient Light-to-Voltage Nonlinear Converter; ODFN6; Temp Range: -40° to 85°C visit Intersil Buy
ISL29023IROZ-T7 Intersil Corporation Integrated Digital Light Sensor with Interrupt; AddressSelectionPins::No; Temp Range: -40° to 85°C visit Intersil Buy
ISL29035IROZ-T7A Intersil Corporation Integrated Digital Light Sensor with Interrupt; ODFN6; Temp Range: -40° to 85°C visit Intersil Buy

emergency light

Catalog Datasheet MFG & Type PDF Document Tags

PANASONIC LR20

Abstract: BF541 Hospitals Introducing Hotels Emergency Light Schools A vital safety tool for: â , Emergency Light provides up to 18 hours* of potentially life saving light from its powerful krypton bulb , needed during an emergency or severe weather situation. Thatâ'™s why Panasonicâ'™s Emergency Light is , www.panasonic.com/industrial/battery/industrial â'¢ e-mail: batteries@us.panasonic.com Panasonic Emergency Light , OFF â'¢ Illuminated marking makes the Emergency Light easy to find ON Illuminated marking
Panasonic
Original
Abstract: PRELIMINARY DATA SHEET LND080A/B 85-347VAC True One-Wire Offline Emergency Light Driver , emergency light interface Lowest cost solution Includes full bridge diodes Universal 85VAC-347VAC Input , offline emergency lighting. The LN080 is capable of operating from 120V, 277V, or 347V without requiring the user to utilize different input wires. This reduces returns typical in the emergency lighting , signs and the LND080B for emergency lights. A switch driver and debounce circuitry allow regulatory Linear Dimensions Semiconductor
Original
LND080 LND080A

schematic diagram emergency light

Abstract: emergency light DN65 ZXSC310 Solution for emergency light Description This solution is provided for an emergency light driving 8 white LEDs connected in series from a 4 cell input. ZXSC310 Figure 1 Figure 2 Issue 3 - July 2006 © Zetex Semiconductors plc 2006 Schematic diagram Performance graphs 1 www.zetex.com DN65 Reference Part no. Value Manufacturer Contact details U1 ZXSC310E5 LED driver Zetex www.zetex.com Q1 FMMT619 2A, low VCE(sat) Zetex www.zetex.com
Zetex Semiconductors
Original
ZHCS1000 NSPW500BS D-81673 schematic diagram emergency light emergency light ZETEX dn65 LPO2506OB-683

scr c108

Abstract: emergency light circuit SCR REPRESENTATIVE APPLICATIONS OF THE C108 SCR 1. Emergency Light This simple circuit provides battery operated , emergency light turns off and the battery recharges automatically. The circuit is ideal for use in elevator , SCR. By this means the SCR is prevented from triggering, and the emergency light stays off. At the , energizes the emergency light. Reset is automatic when AC is restored, because the peak AC line voltage , ) TYPICAL APPLICATIONS MOTOR CONTROL LIGHT TEMPERATURE PRESSURE TIME LIQUID LEVEL Electric Model
-
OCR Scan
IN5059 scr c108 emergency light circuit SCR General electric SCR universal MOTOR speed control using scr SCR TRIGGER circuit dc charger scr battery charger 1N5059 1N5060 C108B1 C108D1

ELPS502

Abstract: crouse-hinds exit emergency EVLA12 · Key operated disconnect switch as part of the ELPS502 emergency light system . S794 · Keyless operated designated disconnect switch as part of the ELPS502 emergency light , 10L ELPS Light-PakTM Emergency Lighting System Applications: ELPS Series Emergency , emergency lighting is needed 10L Features: · Compact factory-sealed luminaire assemblies are each , and consistent light aiming capabilities · Luminaire lens ring is threaded for easy relamping and
Cooper Crouse-Hinds
Original
ELPS50 crouse-hinds exit emergency corrosion inhibitor emergency light circuit diagram Luminaire Photometric data CID101

Re-designing Normally-on load Switches with Zero-power MOSFETs Reduces Power Consumption

Abstract: P-Channel Depletion Mosfets order to build a circuit that performs and emulates this required function. An emergency light , backup battery pack to power an emergency light or an alarm. The AC power module is always on and must , consumes several watts of AC power continuously just to enable this emergency light module. The actual , . A burglar alarm or an emergency alarm requiring the system to be in a normally-ON state is an , circuit only when the emergency module looses AC power. During the rest of the time, the design wants to
-
Original
ALD110900A ALD110800 ALD110900 Re-designing Normally-on load Switches with Zero-power MOSFETs Reduces Power Consumption P-Channel Depletion Mosfets emergency light using mosfet depletion MOSFET

circuit diagram tube ballast for 40W tube l

Abstract: circuit diagram electronic ballast for 40W tube l provides a three-hour emergency light period, depending on the state of charge and battery condition , emergency light output. When the mains supply is restored the battery Max. case temp. _ 70°C (at , . As the running lumens of this lamp is 5700 (based on 2000 hr output) the light output on emergency , Issued November 1991 C12075 Fluorescent luminaire emergency conversion kits Description RS Stock , and twin fluorescent luminaires and l 3-hour duration compact fluorescent luminaires into emergency l
RS Components
Original
circuit diagram tube ballast for 40W tube l circuit diagram electronic ballast for 40W tube l circuit diagram electronic ballast for 18W tube emergency light 2 x 36W 36W Fluorescent Lamp Inverter design electronic ballast for 36 watt fluorescent tube l

ELECTRONIC BALLAST DIAGRAM for PL-C 26W

Abstract: circuit diagram electronic ballast for 40W tube emergency light period, depending on the state of charge and battery condition. Description The RS , automatically connects the battery to the fitting and provides a three-hour duration emergency light output , this lamp is 5700 (based on 2000 hr output) the light output on emergency duty will be 5700 0.12 = , Issued November 1991 012-075 Data Pack C Data Sheet Fluorescent luminaire emergency , luminaires into emergency lighting units. The module and battery pack can be mounted inside existing
RS Components
Original
ELECTRONIC BALLAST DIAGRAM for PL-C 26W circuit diagram electronic ballast for 40W tube circuit diagram tube ballast for 40W tube 20w fluorescent emergency light Electronic ballast for 40W 4 pin tubes circuit diagram electronic ballast for 40W tube 2

ELECTRONIC BALLAST DIAGRAM for PL-C 26W

Abstract: 36W Fluorescent Lamp Inverter design emergency light period, depending on the state of charge and battery condition. Description The RS , automatically connects the battery to the fitting and provides a three-hour duration emergency light output , this lamp is 5700 (based on 2000 hr output) the light output on emergency duty will be 5700 0.12 = , Issued March 1997 232-3507 Data Pack C Data Sheet Fluorescent luminaire emergency , luminaires into emergency lighting units. The module and battery pack can be mounted inside existing
RS Components
Original
electronic ballast for tube light 36 ELECTRONIC BALLAST DIAGRAM 20w circuit diagram electronic ballast for 36W tube ELECTRONIC BALLAST DIAGRAM 28w ELECTRONIC BALLAST 36W circuit diagram circuit diagram of emergency light

SCR GE C5u

Abstract: scr C203 REPRESENTATIVE APPLICATIONS OF THE C108 SCR 1. Emergency Light This simple circuit provides battery operated , emergency light turns off and the battery recharges automatically. The circuit is ideal for use in elevator , SCR. By this means the SCR is prevented from triggering, and the emergency light stays off. At the , energizes the emergency light. Reset is automatic when AC is restored, because the peak AC line voltage , SIZE) TYPICAL APPLICATIONS MOTOR CONTROL LIGHT TEMPERATURE PRESSURE TIME LIQUID LEVEL Electric
-
OCR Scan
SCR GE C5u scr C203 SCR C103 C5U SCR SCR GE C203 C5U SCR GE 2N877-81 2N5060-64 2N2322-29 2N1595-99 II111I811S
Abstract: Convenient swivel hook, attached easily and holds the light in position On the Spot Emergency Light , 16440 - Cordless Rechargeable 30-LED Light Cordless: Allows freedom of movement and ability to , Super-bright, long-life LEDs provide forward directed pure white light. LEDs produce very little heat , : Polycarbonate tube protects the entire light. Strong enough to withstand being driven over by a vehicle , ") diameter allows access into tight areas. Swivel Friction Hook: Swivel hook design allows the light to be Robinair
Original
50/60H 16441E

emergency light

Abstract: 80-CRI ARPL-Star-1W UV Applications · the products high reliability · low energy consumption · used to purpose lamp · flash light · traveling light · emergency light · mine light · alarm light and every kind floodlight Package Dimensions Absolute Maximum Ratings at TA=25°C Parameter Symbol Min. Typ. Max. Unit Forward Current IF - 350 400 mA Forward Voltage VF - 3.2 3.6 V 2 1/2 80 100 120 deg Half angle Luminous FLUX Flux
-
Original
80-CRI flash light 80CRI

emergency exit sign

Abstract: fluorescent display nec battery ­ no need for maintenance. Catalog # 80141 Description Emergency light with rectangular lampsoe Emergency Evacuation Frames · Holders display your custom evacuation maps · Clear acrylic , Floodlights provide up to two hours of light for a safer exit in a power outage Provides safety lighting in times of emergency Big Beam® Combination Lighting · 20 gauge steel cabinet can be ceiling or surface , "D. Catalog # 56905 56907 Description Black Housing/Red Lens White Housing/Red Lens Big Beam® Emergency
BRADY
Original
emergency exit sign fluorescent display nec 277AC

CDT-TX-01

Abstract: CDT-RX-01 control for construction site and factory Emergency stop equipment, Emergency light, Alarm system
Circuit Design
Original
CDT-TX-01 CDT-RX-01 tx 434 TRANSMITTER tx module 434 Photo MOS Relay RX 434 RF RECEIVER CDT-TX/RX-01 920MH 075MH MSK1200

6 channel rf transmitter circuit

Abstract: 4 channel RF transmitter and Receiver circuit control for construction site and factory Emergency stop equipment, Emergency light, Alarm system
Circuit Design
Original
CDT-RX-02 6 channel rf transmitter circuit 4 channel RF transmitter and Receiver circuit photo Receiver Modules 12V RELAY door 6 channel RF transmitter and Receiver circuit CDT-TX-02 CDT-TX/RX-02 CDT-TX/RX-02DS

Cool White Leds

Abstract: flashlight Hunters, hikers, campers · Utility workers · Car emergency light Custom Options (for qualified , light output rate · Puts out an impressive 50 foot-candles Applications · Chart reading for pilots , (370nm) · Infrared LEDs (850, 880, 940nm) · Darkroom safelight for light sensitive film/paper
LEDtronics
Original
Cool White Leds flashlight FLT-1050-3WW 8000K
Abstract: Lithium Ion UR18650U Features & Benefits Specifications â'¢ High power density and low charge voltage model â'¢ Extremely long life â'¢ Ideal for backup (server, emergency light, UPS, etc), electric power based applications, etc Rated capacity(1) Min. 1100mAh Capacity(2) Min. 1100mAh Typ. 1200mAh Nominal voltage 3.6V Charging CC-CV, Std. 770mA, 4.0V, 3.0 hrs Weight (max.) 42.5 g Temperature Charge: Discharge: Storage: Energy density(3) Volumetric: Gravimetric Panasonic
Original

Photoresistor

Abstract: photoresistor datasheet emergency lighting system that turns on automatically with loss of power. The preferred emergency light , Maxim > App Notes > Amplifier and Comparator Circuits Display Drivers Keywords: Emergency lighting, white LEDs, light detection, photoresistor, comparators Feb 16, 2005 APPLICATION NOTE 3444 Light Is On When Power Is Out Abstract: A loss of AC power during darkness (sensed by a photoresistor , incandescent light bulb (Figure 1). (Note: Use safety precautions when working with the high-voltage AC line
Maxim Integrated Products
Original
MAX1848 MAX9021 AN3444 APP3444 Photoresistor photoresistor datasheet Photoresistor application note Daylight White Leds 120VAC

UL50E

Abstract: junction box Application: Dialight introduces the new state-of-the-art fixture for industrial signal and emergency light. Its rugged solid state design creates a new era where failed lamps and expensive relamping costs become a thing of the past. The RTO series incorporates cutting edge LED technology and is the most efficient light source available for industrial lighting applications. Whether your application is , maintenance costs, and a superior quality of light. Mechanical Information: Container Dimensions: 7.60
Dialight
Original
RTO-0W07-001 UL50E junction box L1598 UL844 RTO-BW07-001 RTO-BW07-005

100 led emergency

Abstract: LED emergency light OSNT1 Coupling modules - OCTO series Emergency light tester 1 change-over contact Width 17.5mm Installation design Technical data 1. Functions 7. Control contact Ws Function , emergency lights are disconnected from the mains and the set interval t begins (green LED flashes). After , (yellow LED not illuminated) and the emergency lights are reconnected to the mains. During the interval , 5 15 A1 Emergency lights with integrated recharchable power cells 15 16 18 18
Tele Automation Components
Original
100 led emergency LED emergency light 1000va r15 relay 1250VA 2000VA 1000VA 100VA R15-16