500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
6605424-1 TE Connectivity Ltd Pulse/Datacom Transformer, DATACOM TRANSFORMER FOR AUTOMDIX APPLICATION(S) visit Digikey
5-6605790-1 TE Connectivity Ltd Pulse/Datacom Transformer, DATACOM TRANSFORMER FOR 10/100 APPLICATION(S) visit Digikey
5-6610166-1 TE Connectivity Ltd Pulse/Datacom Transformer, DATACOM TRANSFORMER FOR AUTOMDIX APPLICATION(S) visit Digikey
ICM7242CBA Intersil Corporation PULSE; RECTANGULAR, TIMER, PDSO8 visit Intersil
ICM7555IBAT Intersil Corporation PULSE; RECTANGULAR, 0.1MHz, TIMER, PDSO8 visit Intersil
ICM7555ITV Intersil Corporation PULSE; RECTANGULAR, 0.1MHz, TIMER, MBCY8 visit Intersil

center tap pulse transformer

Catalog Datasheet MFG & Type PDF Document Tags

center tap pulse transformer

Abstract: input and output center tap transformer transformer FFICES center tap. For a coaxial cable, connect the circuit at the transformer center tap , center tap. This gives the required 120 impedance. Z= 120 = = 120 (step-down ratio)2 (1)2 , interface uses two Pulse Engineering transformers designed · Meets 3 kV isolation requirement of many PTT , Engineering transformer, WAN APPLICATION NOTES transformer, P/N PE65839 - 1:1:1.26 RANSMISSION AND 1. P/N PE68646 - 1:1.58:2 1. Pulse Engineering (one per transceiver) 7 P/N PE-65839 P/N PE
-
Original
LXT318 center tap pulse transformer input and output center tap transformer ethernet transformer centre tap center tap transformer 12 to 120 ethernet transformer center tap pulse transformer 56/DDS

DS315X

Abstract: center tap pulse transformer resistor divider instead of the center tap of the transformer for the DS315X and DS325X device. The pulse , the center tap of the transformer and VDD should not exist for the DS315X and DS325X devices. Figure , TX_PLUS to GND. Note 2: The connection between the center tap of the transformer and VDD should not , with resistor divider. Note 3: The connection between the center tap of the transformer and VDD should , Maxim > App Notes > COMMUNICATIONS CIRCUITS TELECOM Keywords: pulse shape, pulse template
Maxim Integrated Products
Original
DS3150 DS3150DK DS3151 DS3152 DS3153 DS3154

center tap transformer

Abstract: Pulse Transformer AES3 side of the system is connected to the center tap of the output transformer. The remote device gets DC power from the input transformer's center tap. Decoupling filters should be used on both ends. 10.4 , CENTER TAP TRANSFORMER CABLE CENTER TAP TRANSFORMER PHANTOM POWER SOURCE Fig. 21 Dual Output Transmitter 110 Balanced / 75 Unbalanced TRANSMITTER CENTER TAP TRANSFORMER 1:1 UNBAL 75 S OUT 110 , transformer's high-frequency corner on the pulse risetime. The upper trace is a low aberration pulse
-
Original
center tap transformer Pulse Transformer AES3 SMALL high frequency transformer Design of H.F. Wideband Power Transformers Design of H. F. Wideband Power Transformers SC979-03

LXT318 Long-Haul E1 Transceiver

Abstract: center tap transformer 12 to 120 coaxial cable, connect the circuit at the transformer center tap. The 1:1.26 step-down ratio gives a , center tap. The 1:1.58 step-up ratio gives a value within 0.2% of the 75 impedance required. Z = x , receive line interface uses the following parts: 1. Pulse Engineering transformer, P/N PE65839 - 1:1:1.26 , ) For a twisted-pair cable, use the 1:1 step-down ratio provided at the center tap. This gives the , long-haul E1 environment. The interface uses two Pulse Engineering transformers designed specifically for
Intel
Original
AN036 LXT318 Long-Haul E1 Transceiver transformer center tap characteristics of twisted pair cable

MIL-STD-1553 cable connector

Abstract: MIL-STD-1553 connector widths of 0.04" (2.5mm) and use short, direct paths for transformer signal and center tap conductors. Ground and Power Planes When transmitting, the transformer center tap (on the transceiver IC side , -1553 Protocol Logic * This center tap is GND often not connected Shielded Twisted Pair MIL-STD , Bus Transceiver N = 1:1.41 * This center tap is often not connected GND , width for the center tap should at least match the analog drive conductor width, but ground plane can
HOLT Integrated Circuits
Original
AN-550 HI-1573 MIL-STD-1553 cable connector MIL-STD-1553 connector HI-1573PS 1553 coupler MIL-HDBK-1553A SMD 2512 resistors MIL-STD-1553 MILSTD-1553 MIL-STD-1553B MIL-STD1553

center tap pulse transformer

Abstract: C1500 actually 1:2 with a center tap. 1:1 operation is obtained by connecting one end of the winding and the center tap, leaving the other end of the winding open. 2 of 3 05/31/01 AN351 VENDOR LIST , Application Note 351 Transformer Selection Guide www.dalsemi.com The following is a list of transformer part numbers from a variety of vendors for use with the DS215x, DS21x5y, DS21Qx5y, DS21E35y , transformer are given in the data sheets for each device and are repeated below for simplicity. Table 1 shows
Dallas Semiconductor
Original
DS2155 DS21E55 DS2148 DS21Q48 DS21552 DS21554 C1500 50480R Schott Magnetics T2032S 46Z232 9836 DS215 DS21Q DS21E35 DS21Q55

IC 92112 8 pin

Abstract: PE-68510 winding is provided in the PE-68510 between pins 9 and 8 of the module. The shunt winding has a center tap at pin 10. Connecting a 75 i i resistor to the center tap allows the cable to be terminated in its , reducing common mode transfer through the magnetics is to couple the center tap of the isolation transform , Pulse. NEW HIGH SPEED LAN MAGNETICS MODULE · · · · · · · SUP PO R TS TW ISTED PAIR FDDI , DIEGO, CA 92112 (619) 674-8100 9 3 8 -4 0 Pulse. AP P LIC A TIO N The PE 68510 and PE 68512 arc
-
OCR Scan
IC 92112 8 pin 92112 ic PE-68512 IC 92112 68512

b-3067

Abstract: BUS-25679 -61590 Universal ACE and the BUS-65149RT hybrid, the transformer center tap, pin 2, MUST NOT be grounded. The , (with the opposite signal polarity). If the transformer center tap is grounded, there is a strong , output stage, through one leg of the isolation transformer to the transformer center tap. It is important to realize that the high current path is through the transformer center tap and not through the , polarity signals. For the BU-61590 or BUS-65149, the transformer center tap must not be grounded. In
Data Device
Original
BU-65620 b-3067 BUS-25679 ddc b-3067 HLP-6002 datasheet center tapped transformer AN/B-27 1-800-DDC-5757 A5976

IEEE802

Abstract: RELIABILITY INC the coax tap which meets signal level and pulse width re quirements is forwarded to the DTE over Dl , 1% tolerance. Isolation transformer module manufacturers include: Valor Electronics: LT6031 Pulse , LT6031 Pulse Transformer U1 Am7997JC U2 PM7005 DC-DC Converter W1 3-Pin Jumper Block (All Resistors are 1 , PRELIM INARY Am7997 IEEE 802.3 10BASE5/2 Coaxial Tap Transceiver DISTINCTIVE CHARACTERISTICS , -802.3 Section 8.3.2.1 specification, the interface between the Am7997 and the AUI is transformer isolated at the
-
OCR Scan
IEEE802 RELIABILITY INC 2vp5u9 ANSI/IEEE-802 10BASE5 10BASE2 IEEE-802 10BASE5/E 10BASE2/C

INNET T2006

Abstract: THROUGH HOLE PRELIMINARY Application Note 351 Transformer Selection Guide This application note lists a number of transformer part numbers from a variety of vendors for use with the DS2151, DS2152, DS2153 & DS2154. Specifications for selecting the appropriate transformer are given in the table below. Some of the 1:1 transformers are actually 1:2 with a center tap. 1:1 operation is obtained by connecting one end of the winding and the center tap, leaving the other end of the winding open. TRANSFORMER
Dallas Semiconductor
Original
T2014 INNET T2006 THROUGH HOLE Midcom 67130840 PE-644 1505D 1205N1 1505NX 1T0008 1T0012 C0031

mad1108P

Abstract: RC05 resistor Setting JP I, JP2 Short R2, R3 open JP3 RX1 transformer tap "FULL" Dual LIU MCLK , measurement short JP9, JP10 Short R13, R14 open JP11 RX0 transformer tap "FULL" JP12 , JP1, JP2 Short R2, R3 open JP3 RX1 transformer tap "FULL" JP4 Dual LIU MCLK input , measurement short JP9, JP10 Short R13, R14 open JP11 RX0 transformer tap "FULL" JP12 , MCLK input is located in the center of the framer interface. 5. Line Interface. The simplest line
Intel
Original
74HC04 mad1108P RC05 resistor 74HC125 dip RC05 RESISTOR RC05 RCO5 LXD332 74HC125

arco 406

Abstract: arco capacitors 262 C1 DUT T2 Output L1 C13 T1 High impedance windings Center tap 9:1 Impedance ratio Center tap C6 C7 C8 C9 C3 C1 - Arco 402, 1.5 ±20 pF C2 - Arco 406, 15 , 20 10V 40 ID, DRAIN CURRENT (A) ID, DRAIN CURRENT (A) 250s PULSE TEST , 0.15 0.3 0.10 t2 t1 = Pulse Duration t 0.1 0.05 0 t1 0.05 Duty Factor D = 1/t2 Peak TJ = PDM x ZJC + TC SINGLE PULSE 10-5 10-4 10-3 10-2 10 -1 1.0
Microsemi
Original
MRF141G arco 406 arco capacitors 262 4953 vrf141g an 4953 mosfet 4953 VRF141G 175MH

arco 402

Abstract: impedance windings Center tap 9:1 Impedance ratio Center tap C6 C7 C8 C9 C3 C1 - , . Typical Performance Curves 25 60 250μs PULSE TEST , Z JC, THERMAL IMPEDANCE (°C/W) 0.40 0.15 0.3 t1 t2 0.10 t1 = Pulse Duration t Duty Factor D = 1/t2 Peak TJ = PDM x ZθJC + TC 0.1 0.05 0.05 SINGLE PULSE 0 10-5 10-4 10-3 10-2 10 -1 1.0 RECTANGULAR PULSE DURATION (seconds) Figure 5. Maximum
Microsemi
Original
arco 402

G020

Abstract: HP4380A RESISTANCE BETWEEN TRANSFORMER'S MEDIA CENTER TAP (MCT) AND GROUND. MEASUREMENT TAKEN USING A HP4380A CABLE , TRANSFORMER'S MEDIA CENTER TAP (MCT) IS TIED TO GROUND. MEASUREMENTS TAKEN USING A HP4380A CABLE ANALYZER IN , RESISTANCE BETWEEN TRANSFORMER'S MEDIA CENTER TAP (MCT) AND GROUND. MEASUREMENT TAKEN USING A HP4380A , WHETHER TRANSFORMER'S MEDIA CENTER TAP (MCT) IS TIED TO GROUND. MEASUREMENTS TAKEN USING A HP4380A CABLE , OHMIC VALUE IN TITLE REFLECTS VALUE OF RESISTANCE BETWEEN TRANSFORMER'S MEDIA CENTER TAP (MCT) AND
Pulse Engineering
Original
H5004 HP8751A G020 MCT-211 9933 b H5007 1000B 10/100/1000B HP4396A HP43961

8041-33

Abstract: transformateurs :1.25:1.25 22 10* 80 5.5" 2.5 B CT: Center Tap - Prise médiane Key Features Caractéristiques Meet , standard Isolation standard 2000 V efficace Well balanced winding with center tap ± 2% Enroulements , Pulse _ A TECHNITROL COMPANY FE 80X1 Series So Interface Transformers Transformateurs , transformer is certified. Les transformateurs FE 8041 répondent à la norme CEI 950 (EN 60950). Le Transformateur FE 8041-33 est homologué CEI 950. So Interface transformer FE 8001 / FE 8031 / FE 8041 is a
-
OCR Scan
BS6301 8041-33 transformateurs 8001-4XZ fe 8041-33 8001-2XZ 8001 SI FE8001 1BS415 1989/BS415 PF600 8001-X5

T-13637

Abstract: 13637 T1/CEPT/ISDN-PRI Pulse Transformer Reinforced Insulation Per EN 41003/EN 60950 Turns Ratio* ( + 5% ) 1CT:1.41CT Parameter Min. Open Circuit Inductance* Max. Units 1.2 mH Oscillation Voltage = 20mV Oscillation Frequency = 100.0 KHz Schematic Diagram 0.80 µH 20 pF Primary DC Resistance 0.6 ohms Secondary DC Resistance 0.8 ohms Leakage Inductance , . Primary Pins 10-6 center tap pin 5 to Secondary pins 1-5 center tap pin 3 1 Tested on Primary Pins 10-6
Rhombus Industries
Original
T-13637 13637 transformer with primary to secondary turns ratio 6 pin pulse transformer 5 pin pulse transformer center tap voltage transformer UL94-VO

TG04-1505N1

Abstract: 8 pin SMD transformer 1. LH: Long Haul; SH: Short Haul; CT: Center Tap; RL: Return Loss. Application Note 5 , ; SH: Short Haul; CT: Center Tap; RL: Return Loss. Table 2. HALO (www.haloelectronics.com)1 , Application Note Transformer Specification for Intel® Transceiver Applications Table 3. PULSE , Transformer Specification for Intel® Transceiver Applications Application Note September 2001 , incompatibilities arising from future changes to them. The Transformer Specification for Intel Transceiver
Intel
Original
AN118 TG04-1505N1 8 pin SMD transformer 64936 8 pin SMD line transformer TD04-1205A TG04-4505NC 0553-0013BC S553-001301 S5536500-62 S553-650040 0553-0013HC

12v to 220v step up transformer

Abstract: 220V ferrite core transformer ideal switch, when Q1 is ON, its drain voltage Vd1 is zero and the Vdd on the center tap of the primary , through C33) be located as close as possible to the center tap of the primary winding of power , DESCRIPTION a. PULSE GENERATION b. RF OUTPUT MATCHING c. DC SUPPLY TEST REQUIREMENTS a. TEST SET UP , ) APPENDIX III (PARTS LIST) APPENDIX IV (TRANSFORMER CONSTRUCTION) www.microsemi.com 1/17 , toroidal inductor and transformer, and sufficient capacitors for output matching circuit. d. The design
Microsemi
Original
DRF1300 12v to 220v step up transformer 220V ferrite core transformer mosfet 5kw high power rf circuit diagram of 13.56MHz RF Generator SCHEMATIC 5kw power supply 30A DRF1300/CLASS-D

220V ferrite core transformer free data

Abstract: rf transformer located as close as possible to the center tap of the primary winding of power transformer T1 have a good , ideal switch, when Q1 is ON, its drain voltage Vd1 is zero and the Vdd on the center tap of the primary , DESCRIPTION a. PULSE GENERATION b. RF OUTPUT MATCHING c. DC SUPPLY TEST REQUIREMENTS a. TEST SET UP , ) APPENDIX III (PARTS LIST) APPENDIX IV (TRANSFORMER CONSTRUCTION) www.microsemi.com 1/17 , circuit, design and construction of a wide-bandwidth, high-current toroidal inductor and transformer, and
Microsemi
Original
220V ferrite core transformer free data rf transformer 16AWG

transformer 1459

Abstract: 2-3 1:1.26 1 - 3 primary: secondary. (CT = Center Tap; CS = Split Center PE-68646 1:1.58 3-5 1:2 1 - 5 Tap). PE-65389 1:1 3-5 1:1.26 1 - 5 PE-65566 1:1 2-3 1:1.26 1 - 3 To make a 1CT:1 , interface transceiver ICs currently available. Use of the proper transformer allows the interface circuit to comply with ITU-T G.703 and other standards regarding pulse waveform, return loss, and balance , . IC RCVE IC XMiT 11 dB 12 dB Transformer Transformer Part Turns Secondary Turns
Pulse Engineering
Original
transformer 1459 PE-68827 PE-65836 E133523 1989/BS 1991/EN CR/0091
Showing first 20 results.