500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
EP1000 GE Critical Power Single Phase, Hot-Pluggable, Fan Cooled SPS Rectifier visit GE Critical Power
EP0300AC48TEZ GE Critical Power EP0300AC48TEZ, Compact, Ssingle Phase, Hotpluggable, Fan-cooled Rectifier and Battery Charger 300W Output at 48-58Vdc visit GE Critical Power
LMV1051SDX-BA/NOPB Texas Instruments Processor for Dual Microphone Adaptive Noise Cancelling with Wind Noise Alert 10-WSON 0 to 60 visit Texas Instruments
TTL-LOGIC-DATABOOK Texas Instruments TTL-LOGIC-DATABOOK visit Texas Instruments
HSP9501JC-32 Intersil Corporation Programmable Data Buffer; PLCC44; Temp Range: 0° to 70° visit Intersil Buy
ISL6444CAZ-T Intersil Corporation PWM Controller with DDR Memory Option for Gateway Applications; QSOP28; Temp Range: 0° to 70° visit Intersil Buy

ceiling fan winding data

Catalog Datasheet MFG & Type PDF Document Tags

single phase induction motor speed control used triac based

Abstract: ac motor speed control circuit with triac and moc Figure 9. True Time Simulator Menu Figure 10. True Time Simulator Data Window Ceiling Fan Speed , Reference Manual · MC9RS08KA2 MC9RS08KA1 Data Sheet · RS08 Core Reference Manual Ceiling Fan Speed , . The traditional mechanical speed control of the ceiling fan can be replaced with this solution , high torque is required. In most fan motors, the capacitor and the auxiliary winding remain connected , designed for optimum efficiency and high power factor (PF). Ceiling Fan Speed Control, Rev. 0 2
Freescale Semiconductor
Original
AN3471 single phase induction motor speed control used triac based ac motor speed control circuit with triac and moc microcontroller based AC fan speed control schematic AC fan speed control schematic TRIAC TAG 86 ceiling fan winding

ceiling fan winding

Abstract: Sinusoidal Vector Control of BLDC Ceiling Fan on MC56F8006 by: Xuwei Zhou Contents 1 Introduction , ceiling fan appeared in the early 1860s and 1870s in the U.S., and it had some up and downs in the , of the motor is fixed to the ceiling using a specific mechanism. 2 Requirements of ceiling fan system.2 3 BLDC ceiling fan driveâ'"sensorless sinusoidal vector control , .15 Ceiling fans are mainly used for ventilation. Usually, in summer, the direction of the fan rotation is
Freescale Semiconductor
Original
AN4612 MC56F800

MOTOR RF-300C-09550

Abstract: 12v dc driver motor control mosfet 3-Phase BLDC Motor Control Demonstration: Fan Application Overview This reference design demonstrates a fan application with multiple preprogrammed speed controls and linear speed control. This , switch (ON / OFF) ZNEO Core MCU MICRF220 Receiver Receives data in the 300MHz to 450MHz range , . Receives data wirelessly in the 300MHz to 450MHz frequency range. Blender firmware, controls BLDC motor via the MIC4101 MOSFET drivers. 3-Phase BLDC Motor Control Demonstration: Fan Application
Micrel Semiconductor
Original
MOTOR RF-300C-09550 12v dc driver motor control mosfet ceiling fan winding data MIC4604 300MH 450MH MIC5235 MIC4682 MIC38C44A
Abstract: DATA SHEET D-160 KBWC Wall-Mount Series Solid-State Variable Speed AC Motor Controls , â'¢ Ceiling Fans â'¢ Attic Fans Pkg.â'Eâ' â'¢ Ventilators â'¢ Range Hoods STANDARD FEATURES , winding, or reactive methods of speed control. The full-wave phase control circuitry minimizes power , by Model No. © KB Electronics, Inc., Coral Springs, FL 33065 DATA SHEET D-160 ELECTRICAL , , Inc., Coral Springs, FL 33065 DATA SHEET D-160 KBWC-13, 23 (Pkg. B) Mechanical Specifications KB Electronics
Original
A42012

ceiling fan speed regulator circuit

Abstract: interior permanent magnet setup. These parameters are normally obtained from motor data sheet. IR Sensorless motor controller can , inductance and equivalent resistance (R: cable + winding). For a surface mounted permanent magnet motor, the , speed feedback signal) of a high inertia fan under speed ramping. As can be seen, the speed response , line of speed regulator tuning for fan applications. 1) Tuning of KpSreg. Run drive at a convenient , (Speed regulator bandwidth) is obtained. For this fan application with high inertia to friction ratio
International Rectifier
Original
IRMCF341 ceiling fan speed regulator circuit interior permanent magnet TEMPERATURE DEPENDENT DC FAN SPEED CONTROL USING Field-Weakening Controller WASHING machine controller washing machine motor AN-1090 IRMCF312 IRMCF311 IRMCF343

ohmite RP06

Abstract: Bolt quick reference chart contact is set so that all of the winding is in the circuit. This makes the condition the same as that of a fixed resistor (assuming a uniform rheostat winding) and we may then say that a rheostat operated , temperature attained (on the exposed winding) of 340°C for rheostats of 100 watts or less and 390°C for , through any part of a uniform winding is determined from Ohm's Law, I=t/W/R. The current values for all , winding). The maximum potentiometer current is the sum of the bleeder current and the maximum load current
-
OCR Scan
ohmite RP06 Bolt quick reference chart MIL-R-6749 AN3155 rheostat 25 watt 1000 ohm ohmite dial

treadmill motor controller

Abstract: ISOLATION PULSE TRANSFORMER 4503 Compressor & Fan Motor Refrigerator Compressor & Fan Motor Washer Motor Dryer Motor Freezer Motor Dishwasher Motor Wet & Dry Vacuum Motor Air-Conditioner Blower Motor Ceiling Fan Motor Attic Fan Motor , high-speed 2 digital data transmission applications (up to 25 Mbit/s), analog sensing, feedback, and , Blower Motor Pool or Spa Pump Motor Jet Pump Motor Paddle Fan Motor Furnace Blower motor Draft , Hood Motor Home Garbage Disposal Motor Compactor Motor Exhaust Fan Motor Spa Pump Motor Power Lite
Agilent Technologies
Original
treadmill motor controller ISOLATION PULSE TRANSFORMER 4503 A 3150 igbt driver inverter IGBT driver hcpl3120 HCPL 454 HCPL454 AN1078 5965-5853E 5980-1297E

pulse transformer 4503

Abstract: ISOLATION PULSE TRANSFORMER 4503 Ceiling Fan Motor Attic Fan Motor Roof Top Attic Ventilator motor Garage Door Opener Motor Microwave Oven Motor Electric Unit Heater Blower Motor Pool or Spa Pump Motor Jet pump Motor Paddle Fan Motor , technology. Modern state of the art optocouplers are available for low- to high-speed digital data , 23 Air-Conditioner Compressor & Fan Motor Refrigerator Compressor & Fan Motor Washer Motor , Compactor motor Exhaust Fan Motor Spa Pump Motor Power Lite TM Flush Toilet Motor Macerator Pump Motor
Avago Technologies
Original
pulse transformer 4503 6 pin pulse transformer 4503 circuit diagram chopper circuit with hcpl 3120 Treadmill speed motor controller pulse transformer 4503 6 pin circuit diagram of treadmill control board 5989-1059EN

ABB inverter motor fault code

Abstract: 3 phase squirrel cage ABB motor star delta 25 2.7.17 Cooling Tower Fan 26 2.7.18 The VLT Solution 26 2.7.19 Condenser Pumps 27 , 5.4.3 Mains Contactors 145 5.4.4 Brake Resistor Temperature Switch 146 5.4.5 External Fan , 7.4.5 Data Control Byte (BCC) 165 7.4.6 The Data Field 165 7.4.7 The PKE Field 166 , 7.4.11 Data Types Supported by the Frequency Converter 168 7.4.12 Conversion 168 7.4.13 , 171 7.8.4 Address Field 171 7.8.5 Function Field 171 7.8.6 Data Field 171 7.8.7
Danfoss
Original
MG16C102 ABB inverter motor fault code 3 phase squirrel cage ABB motor star delta vlt 2900 ABB inverter motor fault abb variable frequency drive wiring diagram PT100 temperature sensor ABB motor 2004/108/EC 130R0278

ST9160B1068

Abstract: ST9160B1084 Thermocouples/Thermopiles 22 Universal Electronic Fan Timer 24 Universal Integrated Furnace Control 26 Fan and Limit Controls 30 Oil/Hydronic Controls 8 Heating/Cooling Devices Gas , able data is correct to the best of Honeywell's knowledge as of this publication's date. However, some , , the Q390A is the right choice 23 Universal Electronic Fan Timer Replaces all others. The new , operations in a gas warm air appliance but also replace all ST9101, ST9103, ST9120, ST9141 and ST9160 fan
Honeywell
Original
ST9160B1068 ST9160B1084 R841D1028 ST9120C2002 ST9120C4057 R8184G1393 Q3200U B340039 B14467 B13819 IGN23 IGN34

76V0A

Abstract: MCHP-045-V31-1 become popular in the telecom power supply industry. Most telecom and data communication systems contain , sequencing, load sharing between the converters, external communication and data logging. Conventional , outputs, and an additional microcontroller performs the data communication and load sequencing. To , remove heat from the high density board mount power supplies, forced air cooling is applied using a fan. Forced air cooling greatly reduces the required PCB size and heat sink. However, installation of a fan
Microchip Technology
Original
AN1335 76V0A MCHP-045-V31-1 48V 100w SMPS forward High-Speed PWM DS70323 buck boost converter closed loop in matlab VDC-76 PIC33F DS01335A-

stepping motor japan servo

Abstract: PMDSA1S3P01 self-start frequency when not loaded 2-division fs 1-division 2-division The data are measured under , shaft MassWeight Wiring resistance Winding inductance Rotor inertia A/phase /phase , shaft MassWeight Wiring resistance Winding inductance Rotor inertia A/phase /phase , .] Model Single shaft MassWeight Wiring resistance Winding inductance Rotor inertia A/phase , Single shaft MassWeight Wiring resistance Winding inductance Rotor inertia A/phase
SANYO DENKI
Original
stepping motor japan servo PMDSA1S3P01 103h5332 103H7832 stepping motor japan servo 1.8 103H6332-0340 PM-C02P0100-01 PM-C03M0100-01 UL1430AWG22 10H5332-03 10H5333-03 F-95958

stepping motor japan servo

Abstract: SHE-001T-P0.6 self-start frequency when not loaded 2-division fs 1-division 2-division The data are measured under , current Wiring resistance Winding inductance MassWeight Rotor inertia A/phase /phase , current Wiring resistance Winding inductance MassWeight Rotor inertia A/phase /phase , .] Model Single shaft Rated current Wiring resistance Winding inductance MassWeight Rotor , ° /step HB type Single shaft MassWeight Rated current Wiring resistance Winding inductance
SANYO DENKI
Original
SHE-001T-P0.6 ac motor direct torque control circuit diagram wi 103H5333-0340 sanyo denki stepping motor pm driver Sanyo Denki servo motor P5 series PM-C03M0100-02

dc motor for 24v braun

Abstract: submersible motor winding formula electronics. Customer-specific winding layout and / or motor part sets available on request. Nominal data , electronics. Customer-specific winding layout and / or motor part sets available on request. Nominal data , winding must be commutated. In conventional DC motors, the commutation commutator segments and , the winding and the active motor parts. Here, it is primarily the number of grooves of the stator , results from the number of phases of the winding and the number of poles of the rotor. For sinus
ebm-papst
Original
dc motor for 24v braun submersible motor winding formula RA-06/11-4 M1138 D-78112 D-74673 D-84030

WD K1N

Abstract: . 107 15.4.4.â'' Inverter data , '¢ Detection of blown PV input fuses. â'¢ Storage of data strings. AC wattmeter kit The AC wattmeter
Ingeteam Power Technology
Original
WD K1N ABB2000IKI02 250TL 400TL 330TL 440TL 375TL

C2514ATZ

Abstract: C2515ATZ . . . . . . . . . . . . . .10 Motor Application Data . . . . . . . . . . . . . . . . . . . . . . . , unusual conditions, such as side-wall and ceiling mounting of horizontal motors or installation of , motor shaft and load shaft must be parallel and the sheaves aligned. Refer to "Motor Application Data , ceiling, and with the shaft at any angle from horizontal to vertical. Special mountings, duty or thrust , required. Motor Application Data Maximum Safe Speed ! ATTENTION: The machinery builder and/or
Rockwell Automation
Original
C2514ATZ C2515ATZ MC4013ATZ C3212A C3613ATZ mc4013 C210ATZ C440ATZ 1325L-UM002A-EN-P 1325L-5

DCB-274

Abstract: SMC 5/2 way solenoid valve rectifier circuit. 8. A cooling fan or heat sink as necessary. * The DCB-274 will operate at voltages of , Communications Full duplex, 9600 baud, no parity, 8 data bits, 1 stop bit. Note: is the enter key. Apply , . Phase 1A 1B 2A 2B J5 Pin 6 5 4 3 Signal Winding 1 Winding 1 Winding 2 Winding 2 , 5. It may be useful to use an ammeter circuit. This will verify winding currents and proper drive , Gnd +Data in +Data out -Data out -Data in Power for serial adapter Enable party line or single
Advanced Micro Systems
Original
SMC 5/2 way solenoid valve PLC based PROJECTS mini servo motor driver unipolar stepper motor 12 vdc 7,5 deg UPS A1000 abstract on mini ups system circuit design SMC27X2

415v two phase welding machine str CIRCUIT DIAGRAM

Abstract: shell tellus c10 oil circuit currents up to 6000 A Technical data: * Rated voltage: 230/400V; 50/60Hz * Breaking capacity , allows protection of consumers generating short circuit currents up to 6000 A Technical data: * Rated , circuit Technical data: * Rated voltage: 230/400V; 50/60Hz * Breaking capacity (cycle O-CO) in , or indication of the protected circuit Technical data: * Rated voltage: 230/400V; 50/60Hz , power supply Standard EN60898-1 Technical data: EN 60898-2 * Rated voltage: 240V; AC/DC * Breaking
ELMARK
Original
415v two phase welding machine str CIRCUIT DIAGRAM shell tellus c10 oil toroid international ltd P/N TT63-630 shell tellus c10 oil data sheet 33-20l capacitor

stepper em 434

Abstract: 120D10 . A cooling fan or heat sink as necessary. 9. Small screwdrivers for trim pot adjustment. *The DCB , 7 8 Signal J2-1 GND RXTXTX+ RX+ 5V PARTY J1 Comment Not used Power Gnd +Data in +Data out -Data out -Data in Power for serial adapter Enable party line or single Pin 1 2 3 4 5 6 7 8 Signal J1-1 GND RXTXTX+ RX+ N/C PARTY J2 Comment Not used Power Gnd +Data in +Data out -Data out -Data in Not used Enable party line or single All signals on J1 and J2
Advanced Micro Systems
Original
stepper em 434 120D10 opto 120d10 em 434 stepper adapter rj45 to sin-9 incremental optical encoder 5V ttl quadrature DCB-264 SMC26X2

triac ZO 410 MF

Abstract: General Electric SCR Manual, Fifth Edition, 1972 . 218 Using Transient Thermal Resistance Data in High Power Pulsed Thyristor Applications . . . . , MCR68 and MCR69 data sheets, for examples where it is specified.) IT(RMS) ON-STATE RMS CURRENT , on the data sheets and they may indicate that protective devices such as voltage clamps and current , significantly lower the values shown in the data sheets since those values are normally given with the gate , temperature is at or below its rated value. Values shown on data sheets consequently differ somewhat from
ON Semiconductor
Original
triac ZO 410 MF General Electric SCR Manual, Fifth Edition, 1972 Westinghouse SCR handbook Triac motor speed control rca thyristor manual Acid Battery charger 48 volt circuit tl494 HBD855/D DL137/D
Showing first 20 results.