500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LDC2114PWT Texas Instruments 4-Channel HMI Inductive Touch Buttons for Consumer and Low-Power Applications 16-TSSOP -40 to 85 visit Texas Instruments Buy
LDC2114PWR Texas Instruments 4-Channel HMI Inductive Touch Buttons for Consumer and Low-Power Applications 16-TSSOP -40 to 85 visit Texas Instruments
LDC2114YFDT Texas Instruments 4-Channel HMI Inductive Touch Buttons for Consumer and Low-Power Applications 16-DSBGA -40 to 85 visit Texas Instruments
LDC2112YFDT Texas Instruments 2-Channel HMI Inductive Touch Buttons for Consumer and Low-Power Applications 16-DSBGA -40 to 85 visit Texas Instruments Buy
LDC2112PWR Texas Instruments 2-Channel HMI Inductive Touch Buttons for Consumer and Low-Power Applications 16-TSSOP -40 to 85 visit Texas Instruments
LDC2112YFDR Texas Instruments 2-Channel HMI Inductive Touch Buttons for Consumer and Low-Power Applications 16-DSBGA -40 to 85 visit Texas Instruments

application notes on wire drawing machine

Catalog Datasheet MFG & Type PDF Document Tags

Tyco PA66 GF30

Abstract: relay tyco pbt-gf30 . 1-1579007-2 Product Specification: 108-18513 Application Specification: 114-18148 Product Group Drawing , : 108-18513 Application Specification: 114-18148 Product Group Drawing: 1719458 Steel Tab, see , Application Specification: 114-18051 2.8 0.85 9.5 0.8 6.0 1.4 Standard Tab Contacts Wire , appropriate sensor technology for the respective application, and assistance with defining the corresponding , includes robust housing technologies, connector systems, and temperature stable designs based on foil and
TE Connectivity
Original

connector cross reference hrs

Abstract: HR22-SC-122 Drawing for the most current and accurate design information. High-Performance Compact Circular , interface between machine tool motors and operation panels, with a screw coupling type locking machanism , . Easy receptacle mounting A receptacle may be mounted quickly on a panel by tightening a nut. 5. Available with wire protection This type of connector has a shell with a cordbushing for increased cable curvature and protection against wire breakage when bending the wire. 6. High-density design The
-
Original
Abstract: DWN APVD SEE SHEET 1 NOTES: 1 LOCKING LANCE BETWEEN CAVITY-NO. 2 KEYING RIB ON , HOUSING CAVITY AS RECEIVED, BEFORE WIRE TERMINATION 7 STRIP-CLIPS TO BE CUT OFF BY APPLICATION MACHINE 8 PRODUCT PAKED IN STRIP, ON TRAY INSIDE A BOX PER PKG. SPEC. 107-20213 9 10 , TAB-BRIDGE CONNECTORS FOR SPECIAL APPLICATION PRODUCT DESIGNED WITH CONTACTS ON WAY 1-2-3 IN SHORT CIRCUIT , ADDITIONAL DRAWING DETAILS -AA- AND -BB- ALL RIGHTS RESERVED. 19 5 1 I USED ON REVISIONS TE Connectivity
Original

CHAMPOMATOR 2.5 BENCH TERMINATING MACHINE

Abstract: [0.00305] min. on solder end, all over .000050 [0.00127] min. nickel Notes: 1. Contact AMP Incorporated for , equipment. Consult AMP customer drawing for connector dimension requirements. 5. See Application , , bright tinlead plated .000120 [0.00305] min. on solder end, all over .000050 [0.00127] min. nickel Notes , drawing for connector dimension requirements. 5. See Application Specification 114-40036 for the most , on ter mination end, all underplated .000050 [0.00127] min. nickel Recommended Wire Size- 28 AWG
-
OCR Scan

62300-3101

Abstract: 1-2 The Hawk Discrete Wire Termination Machine will operate on 110VAC or 220VAC, 50 or 60 Hz. To , Discrete Wire Termination Machine Sheets 1 thru 4 RSP / PP Parts Order No Description and notes , Hawk Discrete Wire Termination Machine Hawk Discrete Wire Termination Machine Order No , UNCONTROLLED COPY Page 1 of 38 Hawk Discrete Wire Termination Machine WARNING NEVER USE THIS , Discrete Wire Termination Machine Table of Contents SECTION 1. General Description 2
Molex
Original
62300-3101 ATS-62300-3100 ATS-6230031005 1-800-78MOLEX
Abstract: Top Wire Stripping Machine Assembly Drawing Order No: TM-638019200 Revision: B Release Date , Pneumatic Bench Top Wire Stripping Machine WS-1000 Pneumatic Bench Top Wire Stripping Machine , : 04-07-11 UNCONTROLLED COPY Page 1 of 20 Pneumatic Bench Top Wire Stripping Machine Table of , Top Wire Stripping Machine 1. WARNING MOLEX CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY RESULTING , . WARNING THE PNEUMATIC BENCH TOP WIRE STRIPPING MACHINE IS NOT INTENDED FOR THE PROCESSING OF MATERIALS Molex
Original
Abstract: may change for double wire application, in which case, see Customer Drawing of terminal. (8 , each terminal is provided on the Customer Drawing. Only insulated wire may be terminated in the crimp , . There is a front and back slot for each wire, and four locking barbs on each terminal to ensure , .020, and .187 x .032 in.] sizes. A special varnish resistant coating is available for application on , Wire End Housing Exposed Wire End Housing Machine Trim Blade Machine Trim Blade Exposed TE Connectivity
Original

E13288

Abstract: Terminal crimping training terminals. The wire size for crimp, poke­in, and solder type terminals is provided on the Customer Drawing , varnish resistant coating is available for application on terminal interfaces which are exposed to , open end slot on the trim side to allow protrusion of the wire. The protruding wire end and wire , 2. Top-Trim Applications (Ref) Exposed Wire End Housing Machine Trim Blade Machine Trim , terminal or wire. (4) The housing must have a wire trim support if automatic machine insertion is used
Tyco Electronics
Original
E13288 Terminal crimping training bellmouth POKE

HR10A-TC-04

Abstract: A receptacle may be mounted quickly on a panel by tightening a nut. 5. Available with wire , Drawing for the most current and accurate design information. High-Performance Compact Circular , interface between machine tool motors and operation panels, with a screw coupling type locking machanism to , protection against wire breakage when bending the wire. 6. High-density design The maximum plug dia. is , catalog is for reference Please request the Engineering Drawing for the most current and accurate design
Hirose Electric
Original
HR10A-TC-04 HR22-12P-T01 HR22-12WTPA HR22-12TPD HR22-TA2428HC CM-105 AP105-HR22-2

micro servo 9g

Abstract: micro servo 9g how to control . Cavity Slot for Wire The width has to be in accordance with the wire size (see Application , , depending on the magnet wire size being applied. I (A) 4 Dimensions are in inches and millimeters , Catalog 82221 Magnet Wire Terminals and Termination Systems Revised 10-02 Standard MAG-MATE Terminals Product Facts Terminates all magnet wire film insulations s Eliminates need for prestripping conductors s Eliminates need to post insulate termination s Excess magnet wire is
Tyco Electronics
Original
micro servo 9g micro servo 9g how to control faston Weld tabs ul 62429-5 AMP PCB SLIM HEADER 331004
Abstract: WIRE CUT-OFF TAB CONDUCTOR CRIMP SEAM The above terminal drawing is a generic terminal , * * Available from an industrial supply company such as MSC (1-800-645-7270). See spacer assembly notes on page , spacer assembly notes on page 3. Release Date: 06-05-07 Revision Date: 05-26-09 UNCONTROLLED COPY , supplied with the press or wire-processing machine in place. Reference the press or wire processing , terminals, applicators and tooling. Contact Information For more information on Molex Application Molex
Original
ATS-638326100
Abstract: * * Available from an industrial supply company such as MSC (1-800-645-7270). See spacer assembly notes on page , spacer assembly notes on page 3. Release Date: 06-05-07 Revision Date: 05-26-09 UNCONTROLLED COPY , supplied with the press or wire-processing machine in place. Reference the press or wire processing , terminals, applicators and tooling. Contact Information For more information on Molex Application , changed. No additional parts are required. See Changeover Parts on page 3 of Application Tooling Molex
Original
ATS-638326000

ST62E4X-EPB1

Abstract: 41K64 's commitment to Service ensures expert application aware technical support which draws on consolidated know-how , application by drawing symbols and wiring them together. Each symbol represents a process, such as adding two , application in schemes. A scheme is like a scheme on which you place symbols and draw wires. Each application , charger application. · Create the scheme on which you'll draw the application. · Define the ST6 microcontroller on which the application will be loaded. 3.1.1 Creating the Project File Each application you
STMicroelectronics
Original
ST62E4X-EPB1 41K64 dialogue st6220 programmer cross compiler user guide st7 ST10 DOC-ST6REALIZER/21

ST62 gang programmer schematic

Abstract: 8x8 LED Matrix Display Common anode 's commitment to Service ensures expert application aware technical support which draws on consolidated know-how , microcontrollers. Using ST6-Realizer, you design your application by drawing symbols and wiring them together , When using ST6-Realizer, you design your application in schemes. A scheme is like a scheme on which you place symbols and draw wires. Each application is designed on one scheme. Schemes can include , battery charger application. · Create the scheme on which you'll draw the application. · Define the ST6
STMicroelectronics
Original
ST62 gang programmer schematic 8x8 LED Matrix Display Common anode ST20 ST62 ST6200 ST6210

408-9816

Abstract: E13288 through the housing. The wire size for each terminal is provided on the customer drawing. Note that a , Poke­In Terminals. There is a wire termination slot on both sides of the terminal body. Some terminals , special varnish­resistant coating is available for application on terminal interfaces which are exposed to , open end slot on the trim side to allow protrusion of the wire. The protruding wire end and wire , 2. Machine Trim Blade Open End Slot Magnet Wire Scrap Trim Support Scrap Wire Anvil
Tyco Electronics
Original
408-9816

114-18063

Abstract: mass air flow sensor pbt-gf30 relevant application specification. Correct selection of wire, terminal and applicator Examples , deformed Wire Range (mm2) Tolerance (mm) Application Spec. MQS 962885 962886 0.2­0.5 , . Please note that wire and insulation sizes are for guidance only. Consult the customer drawing for , unsealed applications single wire sealing or the clean body version can give you high ability on the , function. For low current application (wire size less than 1.0 mm) you are still in the pitch range of
Tyco Electronics
Original
114-18063 mass air flow sensor pbt-gf30 pbt-GF15 PBT - GF15 connector AMP PBT gf30 connector tyco pbt gf15
Abstract: other end into a grounded outlet. The Hawk Discrete Wire Termination Machine will operate on 110VAC or , Hawk Discrete Wire Termination Machine 3.5 Troubleshooting Symptom Switch does not turn on , Page 33 of 39 Hawk Discrete Wire Termination Machine 4.3 Pneumatic Drawing Order No TM , Hawk Discrete Wire Termination Machine Hawk Discrete Wire Termination Machine Operation Manual , Date: 03-03-11 UNCONTROLLED COPY Page 1 of 39 Hawk Discrete Wire Termination Machine Molex
Original
AM-60520E TM-011200949 SDES-70400

Tyco 408-7424

Abstract: faston flag receptacles crimp height requirements and test information. Application Specification 114­2070 provides product information on AMPLIVAR , 235.76 [53] 77.84 [17.5] 1. CMA values are based on standard magnet wire with single film coating , wires are hand fed into the open wire barrel of the contact. This machine is intended for medium volume , Application Specification 114-2152 AMPLIVAR* FASTON* Flag Receptacles NOTE i 15 SEP , application of AMPLIVAR FASTON Flag Receptacles. These right­hand receptacles are offered in designs fitting
Tyco Electronics
Original
Tyco 408-7424 faston flag receptacles crimp height bellmouth standard 408-7424 Tyco faston 187-series

DS1204U

Abstract: the battery input pin on the attached 3-wire device. 11N/OUT - This input/output pin provides an , containing both com mand and data input to the 3-wire serial port. Data is also output on the same pin when , from the 3-wire serial port. In a typical application this pin is used to key the wireless transmitter , , enables the beacon mode of the state machine. Beacon mode turns on and off the TX pin at a 5 KHz rate for , take place between de vices placed on the 3-wire port (DS1201, DS1204U, DS1207, or DS1280) from the
-
OCR Scan
DS1209S-B1 16-PIN DS5000
Abstract: *1 Notes: 1) The emitter does not incorporate the black lead wire. 2) If a connection cable , / TERMINALS Mounting drawing with the receiver HUMAN MACHINE INTERFACES 20 0.787 ENERGY , MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE , enhanced visibility even further by using 8 orange LED lights. FA COMPONENTS MACHINE VISION SYSTEMS , application. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS Panasonic
Original
Showing first 20 results.