NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
KA331_NL Fairchild Semiconductor Corporation Voltage to Frequency Converter ri Buy
PC-SOIC/DIP24-01 Ironwood Electronics SOIC to DIP Package Converters; Top Package Code: SOJ24A_SOJ24B_SOJ24C_SOJ24D; Bottom Package Code: 0.3; Top Pitch (mm): 1.27; Bottom Pitch (mm): 2.54; Top Pin Count: 24; Bottom Pin Count: 24; Top Array Size: N/A; Bottom Array Size: N/A; Top Interface: SOIC Land Pattern; Bottom Interface: Thru Hole Pins; Inside Land Dim. - Ouside land dim. (in.): 0.167 - 0.367; Adapter Size Length X Width (in.): 1.2 x 0.4; Part Description: SOIC to DIP Converter; ri Buy
PC-SOIC/DIP20-04 Ironwood Electronics SOIC to DIP Package Converters; Top Package Code: SO20A_SO20B_SO20D; Bottom Package Code: 0.3; Top Pitch (mm): 1.27; Bottom Pitch (mm): 2.54; Top Pin Count: 20; Bottom Pin Count: 20; Top Array Size: N/A; Bottom Array Size: N/A; Top Interface: SOIC Land Pattern; Bottom Interface: Thru Hole Pins; Inside Land Dim. - Ouside land dim. (in.): 0.275 - 0.475; Adapter Size Length X Width (in.): 1 x 0.4; Part Description: SOIC to DIP Converter; ri Buy

Yamatake converter

Catalog Datasheet Type PDF Document Tags
Abstract: issue: Nov. 2002 No. SS2-MCM100-0100 SS2-MCM100-0100 Yamatake Corporation For converter Failure diagnostics , No. SS2-MCM100-0100 SS2-MCM100-0100 Electromagnetic calorimeter Model MCM10A MCM10A OVERVIEW The Yamatake model , rate is measured by an electromagnetic magnetic flow meter having field proven Yamatake technologies. , calculation is necessary. · The Yamatake model MCM10A MCM10A has a calorie consumption calculation program. · It , The Yamatake model MCM10A MCM10A accumulates the totalized values of calorie consumption for both cooling ... Original
datasheet

4 pages,
297.26 Kb

SUS316L SUS304 SS2-MCM100-0100 Pt 100 sensor connection din pn10 MCM10A sensor for "water meter" Yamatake Flow calorimeter sensor CIRCUIT Yamatake converter AIR FLOW DETECTOR material model yamatake magnetic flow meter Yamatake air flow meter SS2-MCM100-0100 abstract
datasheet frame
Abstract: Model MGZ14 MGZ14 Smart calibrator OVERVIEW The MGZ Smart Calibrator manufactured by Yamatake is used for , supplying a false signal voltage to the signal input terminal of the converter, and monitoring feedback. · , Converter accuracy check at any flow rate and velocity · Gain adjustment · Offset-adjustment of , manufactured by Yamatake (see below). · MagneW series (NNA/NNB/NNX) · MagneW 3000 series (KIC , converter to be calibrated) · Batteries need no charging as dry batteries are used to drive the MGZ. ... Original
datasheet

2 pages,
579.04 Kb

flowmeter electromagnetic MGZ14 nnb yamatake SS2-MGZ200-0100 Yamatake MagneW 3000 series KIC/KIX/KIF YAMATAKE* mgz14 Yamatake MagneW 3000 series KIC Yamatake kix Yamatake converter Yamatake magnew 3000 plus magnew SS2-MGZ200-0100 abstract
datasheet frame
Abstract: SS2-ATT100-0100 SS2-ATT100-0100 (Rev.4) Yamatake Corporation DIMENSIONS Dimensions of converter (Separated sensor type , 1999 Rev.4: Oct. 2003 No. SS2-ATT100-0100 SS2-ATT100-0100 (Rev.4) Yamatake Corporation FUNCTIONAL , current surge:1000 A -2- Yamatake Corporation No. SS2-ATT100-0100 SS2-ATT100-0100 (Rev.4) PHYSICAL , (Feb. 1997). The Flameproof characteristics are guaranteed only when the supplied Yamatake , converter only, not that of the temperature element unit. · The converter may get hot due to the radiated ... Original
datasheet

8 pages,
768.25 Kb

C1602 Yamatake sensor PT100 astm e230-1996 ASTM E230 type T HART 275 Yamatake ATT60 jPT100 Yamatake pt100 IEC584-1 yamatake Sfc 250 JIS C1604-1989 yamatake Sfc ATT60 SS2-ATT100-0100 ATT60/70 SS2-ATT100-0100 abstract
datasheet frame
Abstract: flowmeter converter is a high-performance, and highly reliable flowmeter based on Yamatake's proven MagneW 3000 flow measurement technologies. The model MGG14C MGG14C converter offers expanded flowrate and process , location No. SS2-MGG210-0100 SS2-MGG210-0100 (Rev.3) Yamatake Corporation MODEL SELECTION Converter Model , No. SS2-MGG210-0100 SS2-MGG210-0100 (Rev.3) MagneW 3000 PLUS Smart Electromagnetic Flowmeter Converter , hazardous location only. General model is suitable for use in non - hazardous location. (Remote converter ... Original
datasheet

8 pages,
129.99 Kb

FLOW METER MILK SUS304 Yamatake air flow meter MagneW SS2-MGG210-0100 water conductivity meter circuit Yamatake Flow magnew 3000 plus Yamatake converter Yamatake converter mgg14c Yamatake MagneW MGG14C Yamatake MGG14C SS2-MGG210-0100 abstract
datasheet frame
Abstract: of Yamatake's Model ATT sensor are highly recommended. Combination of ATT71 ATT71 temperature , Communicator (Sold separately) -1- First issue: Jul. 2002 No. SS2-ATT110-0100 SS2-ATT110-0100 Yamatake Corporation STANDARD SPECIFICATIONS Construction Case Aluminum alloy Converter Input type (Select by SFC , ±0.1%F.S. (@17~42V DC) -2- Yamatake Corporation No. SS2-ATT110-0100 SS2-ATT110-0100 Table 2 Conversion accuracy , resistance characteristics -3- No. SS2-ATT110-0100 SS2-ATT110-0100 Yamatake Corporation Example of accuracy ... Original
datasheet

8 pages,
185.48 Kb

ATT61 Thermocouple type k PT100 thermo couple PT100 temperature sensor room sensor pt100 signal converter pt100 sensor PT100 SS2-ATT110-0100 Yamatake jPT100 Yamatake converter Pt100 3 wire yamatake yamatake Sfc SS2-ATT110-0100 abstract
datasheet frame
Abstract: SS2-MGH200-0100 SS2-MGH200-0100 (Rev.3) Yamatake Corporation Digital output range/load resistance For converter (Model , for Pulp Slurry Model MGH14C MGH14C (Converter) / MGH18 MGH18 (Detector) OVERVIEW The MagneW 3000 PLUS HENRI , Pulp & Paper applications based on Yamatake's proven MagneW 3000 flow measurement technologies. The , Paper process. ETFE lining extends life-time of lining than (that of) PFA lining. Remote converter , existing models and those of other suppliers. Please consult your Yamatake representative for details. ... Original
datasheet

12 pages,
164.11 Kb

Yamatake Flow electromagnetic flow meter Flange DIN PN25 flowmeter din pn10 MGA12w c PN16 SUS316L SOURCE IRIDIUM 192 flange jpi 150 Yamatake converter MGH18F f 531 flow meter SS2-MGH200-0100 MGH14C SS2-MGH200-0100 abstract
datasheet frame
Abstract: 0x8742 / 05,01 8800 Vortex Flowmeter 0x8800 / 05,01 MagneW Yamatake MagneW V1.0-FF 0x0001 / 02,02 Yamatake MagneW 2W Yamatake MagneW 2W V1.0-FF 0x0c01 / 01,02 Yokogawa ADMAG , V1.1-FF Yamatake Coriolis Mass Flowmeter Yokogawa ROTOMAS V1.0-FF 0x000D / 01,02 LD800HSE LD800HSE , 848L V1.0-FF 0x848D / 01,05 Smar IF302 IF302 Current to FF Converter Smar IF302 IF302 V1.0-FF 0x0003 / 03,02 FI302 FI302 FF to Current Converter Smar FI302 FI302 V1.0-FF 0x0005 / 03,02 ONYX 461052 ... Original
datasheet

10 pages,
115.71 Kb

FMR130 endress hauser temperature and pressure IF302 endress hauser tmt162 TT302 sipart ps2 vegason 62 FMR240 endress hauser temperature honeywell CM42 PMD235 xmt868 honeywell ST3000 TEMPERATURE datasheet abstract
datasheet frame
Abstract: high-performance and highly-reliable flow meter based on Yamatake's proven MagneW 3000 flow measurement , the terminal box Combined with MGG14C MGG14C converter Stamp the tag with the specified number and , of less than 3mS/cm, consult your Yamatake represen- number is 8. tative) Attaching the tag , Yamatake representative 15 0 to 0.0637 0 to 6.36 1.572 25 0 to 0.177 0 to 17.6 , SPECIFICATIONS Accuracy (in combination with the MGG14C MGG14C converter) Vs(m/s) Measurement ... Original
datasheet

8 pages,
759.05 Kb

munsell 6.5 Yamatake converter JIS10K ICS6-110 din pn10 Yamatake mgg18d Flange DIN PN25 Yamatake, mgg14c SUS316L MGA12W yamatake magnew 3000 parts MGA12w c Yamatake Flow magnew SS2-MGG200-0110 MGG18D SS2-MGG200-0110 abstract
datasheet frame
Abstract: model MGG14C MGG14C converter 3 µS/cm or more -2- 160 C (320 F) Yamatake Corporation No. , high performance and highly reliable flowmeter developed with Yamatake's proven MagneW 3000 flow , Please consult your Yamatake representative for details. Type of protection · Model MGG 17 are , converters can be used in combination with our conventional converters. Please consult your Yamatake , : Feb. 1997 Rev.2: Jun. 2003 No. SS2-MGG200-0200 SS2-MGG200-0200 (Rev.2) Yamatake Corporation APPLICATIONS ... Original
datasheet

16 pages,
649.82 Kb

SS2-MGG200-0200 SS400 DIN PN25 JIS16K Yamatake MGG Flange DIN PN25 MagneW MGG17D MGG17F din pn10 Yamatake Yamatake MagneW MGG14C SCS13 JPI150 SS2-MGG200-0200 abstract
datasheet frame
Abstract: flowmeter detector is a high performance, highly reliable flowmeter developed with Yamatake's proven MagneW , interfaces of our existing models and those of other manufacturers. Please consult your Yamatake , in combination with our conventional converters. Please consult your Yamatake representative for , 1997 Rev.7: Jun. 2003 No. SS2-MGG200-0100 SS2-MGG200-0100 (Rev.7) Yamatake Corporation APPLICATIONS , -2- Yamatake Corporation No. SS2-MGG200-0100 SS2-MGG200-0100 (Rev.7) Measurement flow range Refer to the ... Original
datasheet

28 pages,
314.39 Kb

Yamatake Flow Yamatake MGG14C SCS13 SS2-MGG200-0100 DIN PN25 flange jpi 300 din pn10 magnew magnew 3000 plus Flange DIN PN25 MGG18 Yamatake SS400 bolt nuts G3451 SS2-MGG200-0100 abstract
datasheet frame