NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: Variable soft start Voltage and current synchronization Automatic retriggering switchable Triggering pulse , Programmable overload protection B Autostart C I max GN D 1 Voltage monitoring U2010B i Soft , switched on or after short interruptions of the mains supply. Soft start is initiated after the supply , Comp. Compensation output 6 ILoad Load current limitation 7 Csoft Soft start 8 VRef Reference voltage , /tp, until the triac remains reliably triggered. Rev. A3, 08-NOV-99 08-NOV-99 3(12) u2010b Temic ... | OCR Scan |
11 pages, |
BZX55 DIP SWITCH 10 PIN soft start motor control diagram temic triac dip 16 triac soft starting circuit U2010B U2010B-X U2010B-XFP U2010B-XFPG3 U211B Triac soft start zero crossing detector ic with 230v Triac soft start u2010b U2010B abstract |
| Abstract: monitoring U2010B Soft Reference start voltage Figure 1. Block diagram Ordering Information , input 5 Comp. Compensation output 6 toad Load current limitation 7 Csoft Soft start 8 VRef Reference , Semiconductors u2010b b) Auto start (Pin 9 - open), see figure 12 The circuit behaves as written under amax , Threshold voltage Pin 16 ±Vi 20 60 mV Soft start, see figures 8 and 9 Pin 7 Starting current v7 = , ) ( mV ) Figure 8. Soft start charge current t(s) Figure 9. Soft start characteristic Figure 11. Load ... | OCR Scan |
11 pages, |
BZX55 DIP SWITCH 10 PIN U2010B-X U2010B soft start motor control diagram temic triac dip 16 Triac soft start Triac soft start ic U211B2 zero crossing detector ic with 230v st bzx55 series Triac soft start u2010b U2010B abstract |
| Abstract: threshold 6 Soft start Voltage monitoring U2010B C I max B Autostart A max , Compensated Programmable Load-current Limitation with Over- and High-load Output Variable Soft Start , output 1 Voltage monitoring Load current detector 2 Level shift 3 Soft start 4 5 , control unit = f(V4) Voltage detector R2 330 k R1 18 k/2 W 7 Soft start 10 C1 , Compensation output 6 ILOAD Load current limitation 7 CSOFT Soft start 8 VREF ... | Original |
18 pages, |
VT100 diode v6 33 phase angle control using IC soft start motor control diagram 1n4148 v4 Triac soft start ic triac phase control motor U2010B triac soft starting circuit Triac soft start ic u2010B U211B datasheet abstract |
| Abstract: control unit = f(V4) Voltage detector R2 330 k R1 18 k/2 W 7 Soft start U2010B , 7 R7 8.2 k Overload threshold 6 Soft start Voltage monitoring U2010B C I , Compensated Programmable Load-current Limitation with Over- and High-load Output Variable Soft Start , start 4 5 6 7 U2010B Reference voltage 8 Rev. 4766B 4766BINDCO10/05 2 R6 230 V , limitation 7 CSOFT Soft start 8 VREF Reference voltage 9 MODE Mode selection 10 ... | Original |
18 pages, |
VT100 U211B U2010B Triac soft start u2010b Triac soft start ic datasheet abstract |
| Abstract: Compensated Programmable Load-current Limitation with Over- and High-load Output Variable Soft Start , current detector 2 Level shift 3 Soft start 4 5 6 7 10 GND A max B , Full wave rectifier 16 1 Load current detector 2 Level shift 3 Soft start 4 , limitation 7 CSOFT Soft start 8 VREF Reference voltage 9 MODE Mode selection 10 , after short interruptions of the mains supply. Soft start is isnitiated after the supply voltage has ... | Original |
18 pages, |
VT100 U211B U2010B-M U2010B motor U2010B Triac soft start u2010b zero crossing detector ic with 230v datasheet abstract |
| Abstract: Compensated Programmable Load-current Limitation with Over- and High-load Output Variable Soft Start , current detector 2 Level shift 3 Soft start 4 5 6 7 10 GND A max B , Full wave rectifier 16 1 Load current detector 2 Level shift 3 Soft start 4 , limitation 7 CSOFT Soft start 8 VREF Reference voltage 9 MODE Mode selection 10 , after short interruptions of the mains supply. Soft start is initiated after the supply voltage has been ... | Original |
18 pages, |
zero crossing detector ic with 230v VT100 U211B U2010B motor U2010B u2010 Triac soft start u2010b datasheet abstract |
| Abstract: Compensated Programmable Load-current Limitation with Over- and High-load Output Variable Soft Start , current detector 2 Level shift 3 Soft start 4 5 6 7 10 GND A max B , rectifier 16 1 Load current detector 2 Level shift 3 Soft start 4 5 6 V , CSOFT Soft start 8 VREF Reference voltage 9 MODE Mode selection 10 GND 11 , after short interruptions of the mains supply. Soft start is initiated after the supply voltage has been ... | Original |
18 pages, |
VT100 U211B U2010B motor drilling machine U2010B datasheet abstract |
| Abstract: Load current detector 220 kW U2010B BC308 BC308 Level shift 3 Soft start 4 5 ^ V , voltage D Variable soft start Applications D Voltage and current synchronization D Advanced , Pulse output 1 Voltage monitoring Load current detector 2 Level shift 3 Soft start , 2 R6 Level shift 3 Soft start 4 5 6 C5 0.1 m F ^ V(R6)= $250 mV R5 GND A a max B Auto start C Imax 16 180W R4 10 0.15 m F C3 R11 1 MW U2010B ... | Original |
13 pages, |
zero crossing detector ic with 230v VT100 U211B U2010B BZX55 BYT51K triac TIC U2010B abstract |
| Abstract: shift 3 Soft start 4 5 6 7 Reference voltage 8 Figure 1. Block diagram , detector 2 Level shift 3 Soft start 4 5 w TELEFUNKEN Semiconductors Rev. A2, 11-Mar-98 , Compensation output Load current limitation Soft start Reference voltage Mode selection Ground Supply , U2010B * b) Auto start (Pin 9 open) The circuit behaves as written under max (V9 = 0), with the , voltage Pin 16 VI 20 Soft start, see figures 8 and 9 Pin 7 Starting current V7 = V8 I0 5 10 ... | Original |
12 pages, |
1n4148 v4 triac phase control motor max 11647 full wave rectifier BYT51K U2010B U2010B-A U211B Triac soft start ic tic triac soft start motor control diagram Triac soft start triac soft starting circuit U2010B abstract |
| Abstract: shift 3 Soft start 4 5 6 7 Reference voltage 8 Figure 1. Block diagram , ) Voltage detector R2 330 k W R1 18 k W /2 W 7 Soft start C2 4.7 m F Voltage , Load current limitation Soft start Reference voltage Mode selection Ground Supply voltage High , with a high repetition rate, tpp/tp, until the triac remains reliably triggered. 3 (12) U2010B , U2010B * b) Auto start (Pin 9 open) The circuit behaves as written under max (V9 = 0), with the ... | Original |
12 pages, |
zero crossing detector ic with 230v VT100 U2010B ic 9128 BZX55 BYT51K U211B Triac soft start u2010b U2010B abstract |