500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
TIPD109 Texas Instruments Simple Thermocouple Measurement Solution Reference Design, <1°C Accurate pdf Buy

Search Stock

Part Manufacturer Description Last Check Distributor Ordering
THERMOCOUPLE PROBE (TYPE K) RED/YELLOW Smiths Connectors Contact Probes WIRED PROBE from $117.12 (Sep 2016) Mouser Electronics Buy
THERMOCOUPLE PROBE (TYPE T) RED/BLUE Smiths Connectors Contact Probes WIRED PROBE 7 from $117.12 (Sep 2016) Mouser Electronics Buy

Thermocouple Type K

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: THERMOCOUPLE & RESISTANCE THERMOMETER CONNECTORS TYPE J K T N E R/S Copper , ,K & N TYPE J K N Duplex (Two channel) connectors using thermocouple , Type K Type T Type N Type E Type R Type S THERMOCOUPLE & RESISTANCE THERMOMETER , www.labfacility.co.uk Type J Type K Type T Type N Type E Type R Type S 7 THERMOCOUPLE & , Thermocouple type J,K or T to IEC 60584. Exposed, Welded junction. Tip temperature Rating -75°C to 250 ... Labfacility
Original
datasheet

12 pages,
1846.92 Kb

simplex Thermocouple Type K material CA001 thermocouple connectors IM-K-PCB WK-359 CA-026 IEC 584-3 Labfacility HT 25-19 transistor barrier type double row screw terminal NICR-NI thermocouple k type thermocouple sensor Thermocouple type k PT100 Thermocouple Type K Thermocouple type J PT100 Thermocouple color Din 43714 BS1843 Thermocouple Type K material TEXT
datasheet frame
Abstract: review the type N thermocouple is not merely an For these reasons type K thermocouples are improved , type K but any nickel characteristics of a particular melt. Consequently, based thermocouple. there , K and N but with type N a simple vary from thermocouple to thermocouple. Unknown solution is , type K but are the best combination of elements giving optimum results for a thermocouple based on , formation of silicates on the surface of the wires, these form 4 E15248 E15248 Type K, N and J thermocouple ... RS Components
Original
datasheet

16 pages,
814.89 Kb

151-259 25654 2855 30SWG 500 platinum Hot wire E15248 612-855 610067 inconel 625 corrosion RS stock no.158-597 151-271 158-525 160-540 type n thermocouple Thermocouple Type K 150004 BS1843 RS 611-234 BS4937 RS 610-067 TEXT
datasheet frame
Abstract: .* M12-K- M12-K-(*)-M-FM Thermocouple Type Positive Terminal Negative Terminal K Chromel Pin , . Description M12-K-R-M-FM M12-K-R-M-FM Type K thermocouple right angled M12 male connector M12-J-R-M-FM M12-J-R-M-FM Type J , connector M12-E-R-M-FM M12-E-R-M-FM Type E thermocouple right angled M12 male connector M12-K-S-M-FM M12-K-S-M-FM Type K , M12 male connector M12-K-R-F-FM M12-K-R-F-FM Type K thermocouple right angled M12 female (socket) connector , female (socket) connector M12-K-S-F-FM M12-K-S-F-FM Type K thermocouple straight M12 female (socket) connector ... Omega Engineering
Original
datasheet

2 pages,
228.82 Kb

M12-FM TEXT
datasheet frame
Abstract: the measurement junction of the thermocouple. Figure 3 Typical temperature gradient for type K , oxidisation and hence change in EMF. A type K thermocouple will eventually fail mechanically when the wire is , thermocouple which, as far as possible, overcomes all the disadvantages of not only type K but any nickel based thermocouple. Minerally insulated type K thermocouples can suffer other problems which are shared by type N , . 257-284 Digital temperature indicator Panel mounting digital indicators Type K, N and J thermocouple ... Original
datasheet

16 pages,
106.45 Kb

wire pvc SYSCAL R1 rs 312-561 IEC 584-3 285-728 28548 BS 4937 2194630 219-4810 2194315 2194309 BS4937 pt30 BS1843 219-4315 BS4937 TEXT
datasheet frame
Abstract: input of thermocouple type (K, J, or T) and temperature display is via the DEBUG window. ' - , temperature will be incorrect. Type K J T Materials Chromel / Alumel Iron / Constantan Copper , , "=", CR, CR, "Select TC Type (1 - 3)", CR, CR, "(1) K - Chromel/Alumel", CR, "(2) J - Iron , 4.7 k Vin IS1 0.1 uF 8 Parallax, Inc. · DS2760 DS2760 Thermocouple Kit (#28022) · 01/2004 , Educational: www.stampsinclass.com DS2760 DS2760 Thermocouple Kit (#28022) 1-Wire® Thermocouple Interface ... Dallas Semiconductor
Original
datasheet

8 pages,
86.9 Kb

DS2760TC chromel alumel cold junction Thermocouple Type T material testing crsrxy Cold Junction Compensation Thermocouple Type K Parallax thermocouple DS2760 chromel seebeck Temperature thermocouple 1-wire constantan seebeck Table T type thermocouple bs2pe parallax ds2760 chromel alumel seebeck chromel seebeck Table TEXT
datasheet frame
Abstract: temperature for several thermocouple types The K type is the most linear while the S type is one of the , (type K) thermocouple is the most linear With this type a compensation accuracy of g C can be obtained , Junction TABLE I Nonlinearity Error of Thermometer Using Type K Thermocouple (Scale Factor 25 47 C mV , C temperature range using J or K type thermocouples In addition a thermocouple amplifier using an , temperature range can be obtained with any thermocouple type by the proper adjustment of voltage TC and ... National Semiconductor
Original
datasheet

6 pages,
123.68 Kb

7471 AN-225 b17 zener diode chromel alumel seebeck chromel seebeck Temperature LB-22 LH0044C LM235 LM135 Allen Bradley POTENTIOMETERS Transistor lm335 LM329B Thermocouple IC 7471 Allen Bradley POTENTIOMETERS, type j Omega k type thermocouple range TEXT
datasheet frame
Abstract: J, K, T, and E types Accessories RTDs Thermocouple plugs (J, K, T, E) Spring-loaded , available for J, K, T, and E type thermocouples. RTDs RTDs are popular for high-accuracy temperature , Thermocouple Miniconnector Plugs (Quantity 10) J type .745688-J10 745688-J10 K type .745688-K10 745688-K10 T type , Ready-Made Thermocouple Calibrations Thermocouple Characteristics Extension Wire Calibration J type ... National Instruments
Original
datasheet

2 pages,
140.22 Kb

745691-01 rtds accuracy of K type thermocouple 745685-T01 type j thermocouple k type thermocouple sensor K030 SC-2345 SCXI-1112 J001 745690-E001 K001 k type thermocouple 745685-T02 j type thermocouple sensor thermocouple 745690-T002 Thermocouple Type K thermocouples sensors Thermocouple color TEXT
datasheet frame
Abstract: compensation. The AD849x is optimized to measure and amplify J and K type thermocouple signals for a linear 5 , thermocouple changes by 52 V/°C at 25°C and by 55 V/°C at 150°C. K type thermocouples tend to be much more , Ranges Thermocouple Type J K J K Part AD8494 AD8494 AD8495 AD8495 AD8496 AD8496 AD8497 AD8497 Max Error ±2°C ±2°C , reference pin connected to a K type thermocouple that reads 1 V), the correction procedure is as follows , connected to a K type thermocouple outputs 1 V. Using the 5 mV/°C transfer function, 1 V represents 200 ... Analog Devices
Original
datasheet

4 pages,
114.58 Kb

320 702/1 diode AN-1087 cold junction Cold Junction Compensation J type thermocouple Thermocouple Type K 4937 Amplifier type K thermocouple e 803 AD8496 k type thermocouple sensor Thermocouple Type K linearization AD849x vtc 365 Amplifier type t thermocouple AD8497 AD8494 ad8495 k type thermocouple AD8494/AD8495/AD8496/AD8497 TEXT
datasheet frame
Abstract: Thermocouple Wires 100' coils of insulated 24-AWG 24-AWG thermocouple wire Type K Range: +32°F to +545°F (0°C to , Thermocouple Type K w/ connector TCP6-K12 TCP6-K12 $35 Initial Range: Accuracy: +32°F to +559°F (0°C to +293°C , 100' of 24-AWG 24-AWG Thermocouple Wire Type J TCW100-J TCW100-J Type K TCW100-K TCW100-K Type T TCW100-T TCW100-T $55 $55 , connectors and plug directly into HOBO® Thermocouple Family loggers. The connectors are color-coded for type , , K, and T versions available Specifications Type J Range: +32°F to +482°F (0°C to +250°C) x ... Onset Computer
Original
datasheet

1 pages,
670.34 Kb

Thermocouple Type K k type thermocouple cable 537C 356f TCW100-K thermocouple connectors TCP6-K12 30AWG 1C TEXT
datasheet frame
Abstract: plotted as a function of temperature for several thermocouple types. The K type is the most linear , °C. Thermocouple nonlinearity results in additional compensation error. The chromel/alumel (type K) thermocouple , Junction TABLE 1. Nonlinearity Error of Thermometer Using Type K Thermocouple (Scale Factor 25.47°C/uV , °C temperature range using J or K type thermocouples. In addition, a thermocouple amplifier using an LM335 LM335 for , divide down the 10 mV/°K output of the LM335 LM335 to match the Seebeck coefficient of the thermocouple. The ... National Semiconductor
Original
datasheet

8 pages,
115.42 Kb

chromel seebeck Temperature Cold Junction Compensation AN-222 chromel seebeck Table Allen Bradley POTENTIOMETERS k type thermocouple sensor LM135-LM235-LM335 chromel alumel Amplifier type t thermocouple chromel alumel seebeck Omega Engineering Thermocouple Type K circuit with thermocouple application LM335 datasheet LB-22 data sheet Lm335 seebeck Omega k type thermocouple range type s thermocouple allen bradley potentiometer type j TEXT
datasheet frame

Archived Files

Abstract Saved from Date Saved File Size Type Download
No abstract text available
/download/64217234-698077ZC/ts001.xls
Sager 16/05/1996 3.08 Kb XLS ts001.xls
No abstract text available
/download/14003373-698485ZC/e5c4.xls
Sager 16/05/1996 4.67 Kb XLS e5c4.xls
No abstract text available
/download/16579563-698488ZC/e5ef.xls
Sager 16/05/1996 5.09 Kb XLS e5ef.xls
No abstract text available
/download/54041296-698484ZC/e5c2.xls
Sager 16/05/1996 6.31 Kb XLS e5c2.xls
No abstract text available
/download/51733595-698516ZC/e5c4.xls
Sager 16/05/1996 6.15 Kb XLS e5c4.xls
No abstract text available
/download/40042436-698515ZC/e5c2.xls
Sager 16/05/1996 5.97 Kb XLS e5c2.xls
microvolt signals generated by a type K thermocouple, provides cold (reference) junction : Isolated input Thermocouple type: K ("Chromel/Alumel") Input to provide curvilinear cold-junction compensation matched to the NBS K thermocouple 1.4 ELECTRICAL ISOLATION 502A-K input (thermocouple and shield) and output (DC MANUALS - 502A-K - REFERENCE
/datasheets/files/omega/newport/manuals/500/502a-k1.htm
Omega 31/03/2000 17.86 Kb HTM 502a-k1.htm
No abstract text available
/download/98514300-62211ZC/ip310513.gse.zip ()
Beckhoff 10/11/2009 2.69 Kb ZIP ip310513.gse.zip
FM3312-B310-0000 FM3312-B310-0000 Fieldbus Module, thermocouple, 12-channel, type K, PROFIBUS interface FM3312-B310-0010 FM3312-B310-0010 Module, thermocouple, 12-channel, type K, PROFIBUS interface FM3312-B310-1010 FM3312-B310-1010 Fieldbus Module , 32-channel, type K, PROFIBUS interface FM3332-B310-0010 FM3332-B310-0010 Fieldbus Module, thermocouple, 32-channel, type J, PROFIBUS interface FM3332-B310-1000 FM3332-B310-1000 Fieldbus Module, thermocouple, 32-channel, type K the number of available thermocouple input channels (12 or 32 channels), the type of thermocouple that
/datasheets/files/beckhoff/catalog/english/fieldbus_box/fm3312_fm3332.htm
Beckhoff 10/11/2009 10.86 Kb HTM fm3312_fm3332.htm
Operates with Type K Thermocouple General Description The AD596/AD597 AD596/AD597 is a K thermocouple input to derive an internal signal proportional to temperature. The internal signal , the AD596/ AD596/ AD597 AD597 can be configured to provide a voltage output (10 mV/°C) directly from a type J or K the AD597 AD597 can accommodate -200°C to +1250°C type K inputs. The AD596/AD597 AD596/AD597 has a required, either the AD594 AD594 (J thermocouple) or AD595 AD595 (K thermocouple) should be considered.
/datasheets/files/analog-devices/gendesc/389.htm
Analog Devices 05/06/2003 2.3 Kb HTM 389.htm