Part Manufacturer Description Datasheet BUY
LDC1000NHRJ Texas Instruments 5V, High Resolution, Inductance to Digital Converter for Inductive Sensing Applications 16-WSON -40 to 125 visit Texas Instruments
LDC1000NHRT Texas Instruments 5V, High Resolution, Inductance to Digital Converter for Inductive Sensing Applications 16-WSON -40 to 125 visit Texas Instruments
LDC1000NHRR Texas Instruments 5V, High Resolution, Inductance to Digital Converter for Inductive Sensing Applications 16-WSON -40 to 125 visit Texas Instruments Buy
LDC1614RGHT Texas Instruments 4-channel, 28-bit Inductance-to-Digital Converter with I<sup>2</sup>C for Inductive Sensing 16-WQFN -40 to 125 visit Texas Instruments Buy
LDC1314RGHT Texas Instruments 4-channel, 12-bit Inductance-to-Digital Converter with I<sup>2</sup>C for Inductive Sensing 16-WQFN -40 to 125 visit Texas Instruments Buy
LDC1312DNTR Texas Instruments 2-channel, 12-bit Inductance-to-Digital Converter with I<sup>2</sup>C for Inductive Sensing 12-WSON -40 to 125 visit Texas Instruments Buy

TRIAC inductive

Catalog Datasheet MFG & Type PDF Document Tags

TRIAC BCR 10 AM

Abstract: TRIAC BCR 1 AM digit part number you desire from the table - i.e. BCR6AM-8 is a 400 Volt, 6 Ampere Triac Inductive Load* L *For inductive load, add L. 0.142 ± 0.008 Dia. 3.6 ± 0.2 Dia. 0.125 ± 0 .0 0 8 3.2 T-27 mumsK Powerex, Inc., 200 Hlllls Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR6AM Triac , TtldC 6 Amperes/400-600 Volts D escription: A triac is a solid state silicon AC switch which may , : Glass Passivation Selected for Inductive Loads A p plicatio n s: AC Switch Heating Motor
-
OCR Scan
TRIAC BCR 10 AM TRIAC BCR 1 AM TRIAC inductive BCR 3A 400V triac bcr T91 relay 00DS201 T--91 1S697 BP107
Abstract: across triac 21607 Resistive load Voltage across triac Inductive load Fig. 8 - Waveforms of Resistive and Inductive Loads The voltage across the triac will rise rapidly at the time the , photosensitive zero crossing TRIAC network. The TRIAC consists of two inverse parallel connected monolithic , lines to control resistive, inductive, or capacitive loads including motors, solenoids, high current thyristors or TRIAC and relays. Applications include solid-state relays, industrial controls, office Vishay Semiconductors
Original
IL4116 IL4117 IL4118 2002/95/EC 2002/96/EC 2011/65/EU
Abstract: /dt Voltage across triac 21607 Resistive load Voltage across triac Inductive load Fig. 8 - Waveforms of Resistive and Inductive Loads The voltage across the triac will rise rapidly , Inductive load Nutral 21609-1 Fig. 12 - Basic Power Triac Driver Circuit www.vishay.com 6 For , a photosensitive zero crossing TRIAC network. The TRIAC consists of two inverse parallel connected , lines to control resistive, inductive, or capacitive loads including motors, solenoids, high current Vishay Semiconductors
Original
JS709A

TRIAC inductive

Abstract: IL4116-X007T Commutating dV/dt Voltage across triac 21607 Resistive load Voltage across triac Inductive load Fig. 8 - Waveforms of Resistive and Inductive Loads The voltage across the triac will rise rapidly , Inductive load Nutral 21609-1 Fig. 12 - Basic Power Triac Driver Circuit www.vishay.com 6 For , crossing TRIAC network. The TRIAC consists of two inverse parallel connected monolithic SCRs. These three , low-voltage logic from 120 VAC, 240 VAC, and 380 VAC lines to control resistive, inductive, or capacitive
Vishay Semiconductors
Original
IL4116-X007T IEC60065 IL4116-X006 RC snubber scr design Zero Crossing Triac Driver Output Optocoupler IL4118-X009
Abstract: /dt Voltage across triac 21607 Resistive load Voltage across triac Inductive load Fig. 8 - Waveforms of Resistive and Inductive Loads The voltage across the triac will rise rapidly , Inductive load Nutral 21609-1 Fig. 12 - Basic Power Triac Driver Circuit www.vishay.com 6 For , a photosensitive zero crossing TRIAC network. The TRIAC consists of two inverse parallel connected , lines to control resistive, inductive, or capacitive loads including motors, solenoids, high current Vishay Semiconductors
Original

diode 1n40001

Abstract: 1N40001 triac driver. Inductive loads are discussed along with the special networks required to use triacs in , "Inductive and Resistive Loads") prevents possible destruction of the triac drive in applications where the load is highly inductive. Unintentional phase control of the main triac may happen if the current , Loads Inductive loads (motors, solenoids, etc.) present a problem for the power triac because the , ACROSS POWER TRIAC Inductive Load Figure 12. Current and Voltage Waveforms During Commutation
Fairchild Semiconductor
Original
AN-3004 diode 1n40001 1N40001 1n40001 DIODE TRIAC FT 12 triac inductor noise suppression moc3063 application note AN300000

Optocoupler MOC 3020

Abstract: optotriac moc3021 PHASE ANGLE 2 i VMT2-1 VOLTAGE/CURRENT 130 Figure 6.8. TRIAC Inductive Load Turn-Off , Figure 13 shows a TRIAC controlling an inductive load in a bridge. The inductive load has a time , used to switch inductive loads at currents less than 100 mA (Figure 24). However a power TRIAC along , MAC 228-10 TRIAC TJ = 110°C Static dV turn-on is a consequence of the Miller effect and dt , highest possible temperature using thyristors with the lowest measured trigger current. TRIAC
Motorola
Original
Optocoupler MOC 3020 optotriac moc3021 MOC3011 optocoupler motorola 5A optocoupler MOC ic moc 3021 triac MAC 120 G AN1048 MOC3011 MOC3021 EB-101 AN982

MAC15 triac

Abstract: "OPTIMUM SNUBBERS FOR POWER SEMICONDUCTORS" . TRIAC Inductive Load Turn-Off dt c has little influence. Commutating dI and dt delay time , storage and recovCommutating dt Circuit Examples Figure 13 shows a TRIAC controlling an inductive , Figure 6.3. Exponential versus Temperature dt s 160 MAC 228A10 TRIAC TJ = 110°C 140 STATIC dV , TRIAC. Turn-off depends on both the Miller effect displacement TRIAC COMMUTATING dV dt current , TRIAC has The commutating dt dt and the currents resulting from internal charge storage within
ON Semiconductor
Original
MAC15 triac moc 3021 scr thyristor firing method for soft start ldc 2000 rev.01 Snubber circuits theory, design and application U AN1048/D

ic moc 3021

Abstract: transistor W2W TRIAC controlling an inductive load in a bridge. The inductive load has a time constant longer than the , VOLTAGE (VOLTS) 700 800 MAC 228A10 TRIAC TJ = 110°C TJ, JUNCTION TEMPERATURE (°C) dV Figure 6.3 , current. TRIAC COMMUTATING dV dt WHAT IS COMMUTATING dV ? dt dV The commutating rating applies when a TRIAC has dt AN1048/D . for sinusoidal currents is given by the slope of the secant line between , frequency and ITM = maximum on-state current in the TRIAC. Turn-off depends on both the Miller effect
ON Semiconductor
Original
transistor W2W RC snubber for 3 phase rectifier bridge 2N390 TRANSISTOR T50 thyristor triac driver opto moc 1000 volt

RC snubber ac motor

Abstract: HY 400 Figure 6.8. TRIAC Inductive Load Turn-Off dV dt s the volume charge begins to influence , an inductive load. The current and voltage are out of phase (Figure 8). The TRIAC attempts to , CHARGE DUE TO dV/dt IRRM Circuit Examples Figure 13 shows a TRIAC controlling an inductive , 6.3. Exponential 160 MAC 228A10 TRIAC TJ = 110°C 140 STATIC dV (V/ s) dt MAC 228A10 VPK , on-state current in the TRIAC. Turn-off depends on both the Miller effect displacement TRIAC
ON Semiconductor
Original
RC snubber ac motor HY 400 BTA08-8003W3G moc opto triac Why R-C Networks And Which One For Your Converter 2n6073 sum

Optocoupler MOC 3020

Abstract: Optocoupler triac 80a Inductive Load Turn-Off dt c ( dV )c Device Physics dt A TRIAC functions like two SCRs connected in , to switch inductive loads at currents less than 100 mA (Figure 24). However a power TRIAC along , consequence of the Miller effect and STATIC ( dV )s Device Physics dt MAC 228-10 TRIAC TJ = 110 , K TRIAC Commutating 100K What is Commutating dV dt dV ? dt dV The commutating - rating applies when a TRIAC has been dt 10K 0.001 0.1 0.01 STATIC 1 10 100
Fairchild Semiconductor
Original
Optocoupler triac 80a HP 2200 optocoupler AN3008 Fairchild RC snubber thyristor design triac snubber ac motor speed control circuit with triac and moc AN-3008

Triac to220

Abstract: Thyristor -220F package Thyristor with built-in avalanche diode, 3A, VBO=225V, TO-220F package Triac for inductive load, 400V, 10A, TO-220F package Triac for resistive load, 400V, 10A, TO-220F package Triac for inductive , inductive load, 400V, 12A, TO-220F package Triac for resistive load, 400V, 12A, TO-220F package Triac for inductive load, 600V, 12A, TO-220F package Triac for resistive load, 600V, 12A, TO-220F package Triac for inductive load, 400V, 16A, TO-3PF package Triac for inductive load, 400V, 16A, TO-3P package Triac for
Sanken Electric
Original
Triac to220 Thyristor triac 400v 16a triac 600v 25a TRIAC 25a 600v Triac 3a 600v ET013 ET015 ET020 SLA0201 STA203A STA221A

RC snubber scr design inductive load

Abstract: triac RC snubber voltage, such as is the case in an inductive load, by the time the current crosses zero and the TRIAC , when the gate signal is removed. dt -50 -100 -150 TRIAC Figure 5-a. Inductive Load and , phase. Figures 5-a and 5-b show the TRIAC voltage and current when driving inductive and resistive , current and perhaps be protected by a fuse. Many loads that utilize TRIAC control are inductive loads , inductive load is a TRIAC application where the load is an electric motor. Electric motors, like any
Vishay Semiconductors
Original
RC snubber scr design inductive load triac RC snubber Gate turn off triac Triac load inductive RC inductive load thyristor design triac snubber design VO425X VO415X EN610004-4 IL420 IL410 IL421X

TRIAC inductive

Abstract: RC snubber dv/dt diode voltage, such as is the case in an inductive load, by the time the current crosses zero and the TRIAC , when the gate signal is removed. dt -50 -100 -150 TRIAC Figure 5-a. Inductive Load and , phase. Figures 5-a and 5-b show the TRIAC voltage and current when driving inductive and resistive , current and perhaps be protected by a fuse. Many loads that utilize TRIAC control are inductive loads , inductive load is a TRIAC application where the load is an electric motor. Electric motors, like any
Vishay Semiconductors
Original
EN61000-4-4 RC snubber dv/dt diode RC snubber dv/dt across scr triac CIRCUIT phototriac TRIAC application note snubber triac snubber ac motor IL411X

DIAC DB2

Abstract: D1 DB2 Diac AN308 Application note TRIAC analog control circuits for inductive loads Introduction The TRIACs of today are well suited to the requirements of switching inductive loads. TRIAC control circuits , drawback. For example, consider a highly inductive load (L / R > 4) where the TRIAC is turned on with a , Figure 6. As an example, take the case of a highly inductive load and an angle = 60°. The TRIAC is , Solutions summary for inductive load control A.1 AN308 Triggering synchronized across the TRIAC
STMicroelectronics
Original
DIAC DB2 D1 DB2 Diac triac diac applications circuit diagram 1.5ke68a1 db1 diac DB2 Diac

triac diac applications circuit diagram

Abstract: TRIAC TLC 226 b AN308 APPLICATION NOTE CONTROL BY A TRIAC FOR AN INDUCTIVE LOAD HOW TO SELECT A SUITABLE CIRCUIT 1. INTRODUCTION Today triacs are well suited to the requirements of switching inductive loads , important drawback. For example, consider a highly inductive load (L / R > 4) where the triac is turned on , on a inductive load. SYNCHRONIZATION ACROSS THE TRIAC Figure 9. Example of an Application , VA ­ AN308 APPLICATION NOTE APPENDIX A. CONTROL BY TRIAC FOR INDUCTIVE LOADS SUMMARY OF
STMicroelectronics
Original
TRIAC TLC 226 b EQUIVALENT NO. OF DB3 DIAC power variation circuit for arc welding DIAC DB3 EQUIVALENT TRIAC 226 b TLC226B

triac diac applications circuit diagram

Abstract: power variation circuit for arc welding ® APPLICATION NOTE CONTROL BY A TRIAC FOR AN INDUCTIVE LOAD HOW TO SELECT A SUITABLE CIRCUIT By X. DURBECQ Today triacs are well suited to the requirements of switching inductive loads , highly inductive load (L / R > 4) where the triac is turned on with a considerable delay = 100° after , , take the case of a highly inductive load and an angle = 60° . The triac is turned on at point A (60 , CONTROL BY TRIAC FOR INDUCTIVE LOADS SUMMARY OF SOLUTIONS A SYNCHRONOUS TRIGGERING ACROSS THE TRIAC
STMicroelectronics
Original
D89AN308-01 arc welding transformer triac arc control triac pulse train triggering welding transformer triac diac applications circuit diagram inductive diac triac control circuit motor 220 V AN308/0289 D89AN308-02

Application Note 35

Abstract: triac RC snubber case in an inductive load, by the time the current crosses zero and the TRIAC turns off, there is , the TRIAC voltage and current when driving inductive and resistive load (at commutation). Both the , loads that utilize TRIAC control are inductive loads where high rates of dV/dt and di/dt require design , through TRIAC. A perfect example of inductive load is a TRIAC application where the load is an electric , them (the inductive load's voltage leads its current). This presents a unique problem with TRIAC
Vishay Semiconductors
Original
Application Note 35 how to test triac snubber application note rc snubber for electromagnetic relays SCR TRIAC triac with snubber

Triac soft start

Abstract: BTA08 ST light dimmer schematics . Inductive load control with Triac i(t) R L VMAIN T u(t) According to Figure 1, the AC load , inductive load is switched on in full-wave, the transient current depends on the Triac first turn-on delay , AN441 Application note Inductive load control with AC switches Introduction AC switches are now commonly used as static switches to drive inductive loads such as magnetic transformers, valves, induction , controlled by AC switches like Triac, ACS or ACST. For example, there is an explanation of just when a Triac
STMicroelectronics
Original
Triac soft start BTA08 ST light dimmer schematics schematic diagram induction microwave oven transformer induction lamp power supply for magnetron

triac bta06

Abstract: TRIAC BTB 16 600 BW load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TRIAC with inductive , control) IG t IT dI/dtOFF t VMains VT dV/dtOFF 1.3.2 t TRIAC with inductive load An inductive load induces a phase lag between the TRIAC current and the mains voltage (see Figure 6 , . Figure 7. TRIAC commutation on an inductive load without a snubber network Load L Load R L , AN439 Application note SnubberlessTM and logic level TRIAC behavior at turn-off Introduction
STMicroelectronics
Original
triac bta06 TRIAC BTB 16 600 BW Z0405 equivalent OPTO TRIAC TRIAC BTA 16 600b TRIAC BTB 12.600 data sheet