500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LP395Z/LFT1 Texas Instruments Ultra Reliable Power Transistor 3-TO-92 visit Texas Instruments
LP395Z/LFT4 Texas Instruments Ultra Reliable Power Transistor 3-TO-92 visit Texas Instruments
LP395Z/NOPB Texas Instruments Ultra Reliable Power Transistor 3-TO-92 -40 to 125 visit Texas Instruments Buy
LM395T Texas Instruments Ultra Reliable Power Transistor 3-TO-220 0 to 125 visit Texas Instruments
LM395T/NOPB Texas Instruments Ultra Reliable Power Transistor 3-TO-220 0 to 125 visit Texas Instruments Buy
OMAP3503EZCBCS Texas Instruments Sitara Processor: ARM Cortex-A8, High Reliability 515-POP-FCBGA 0 to 90 visit Texas Instruments

Relay M302 Reliability

Catalog Datasheet MFG & Type PDF Document Tags

Relay M302 Reliability

Abstract: Leach relay M302 M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of Coil supply MIL-R-83536/12 and /13 Direct , M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , . Intrinsically safe relay. CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000
Esterline Power Systems
Original
Relay M302 Reliability Leach relay M302 M302 PCB Leach relay M83536 SC301-2 SC301-1 SC300 SC400 SC401-1 SC401-2

Relay M302 Reliability

Abstract: Leach relay M302 M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of Coil supply MIL-R-83536/12 and /13 Direct , RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , . Intrinsically safe relay. CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000
Leach International
Original
Leach relay M83536 3 PDT M302 leach relay m300 silicone R140 Relay leach all zener diode colour code SC402

all zener diode colour code

Abstract: S300-A1A2 M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302, M400, M401 , M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay. CONTACT ELECTRICAL
Esterline Power Systems
Original
CECC16101-018 CECC16303-801 S300-A1A2 MIL-S-12883 S300-A6B3 M300 relay S300-A9B9 S300-A8B9 MIL-R-83536/9

Leach relay M83536 3 PDT

Abstract: leach relay 250 B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 MM 2 X2 1 DETAIL 0.9 , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302, M400, M401 , M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay , Vac 400 Hz 40 grams max 26 x 28.6 x 13.3 Intrinsically safe relay. CONTACT ELECTRICAL , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows
Esterline Power Systems
Original
leach relay 250 MIL-R-83536/11

CECC16303-801

Abstract: CECC16101-018 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302, M400, M401 , M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , or 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay. CONTACT ELECTRICAL
Leach International
Original
marking N023 Leach International S300 m2xx Leach International M300 M83536/S300-A6B3 M300 leach

s300a

Abstract: relay m300 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , -Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302, M400, M401 , M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct , 115 Vac 400 Hz 40 grams max 26 x 25.7 x 13.3 Intrinsically safe relay. CONTACT ELECTRICAL
Leach International
Original
s300a FD300 diode

all zener diode colour code

Abstract: Leach relay M83536 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 , SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay , 400 Hz 40 grams max 26 x 28.6 x 13.3 Intrinsically safe relay. CONTACT ELECTRICAL , DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows them to create magnetic
Leach International
Original
relay studs m301 m panel edit tool LEACH switch m300d Leach relay M400

M300 relay

Abstract: Leach relay high temperature POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , power switching and high reliability are required over a wide temperature range. Featuring LEACH , standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap, maximum voltage capabilities of the relay contact system, and the , : A designer is working with a 55 volt DC system and has a relay rated at 10 amps resistive at 28
Esterline Power Systems
Original
Leach relay high temperature TDH-6070/6071 MIL-STD-883 MIL-T-10727 TDH-6070/71 MIL-R-6106 S300-A6A2

Leach Relay Reliability

Abstract: TDH-6050 POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , applications where power switching and high reliability are required over a wide temperature range. AMERICAS , TIME DELAY RELAY DE-ENERGIZED OUTPUT DETAIL VIEW A ENERGIZED DETAIL VIEW B ALL DIMENSIONS , CONTACTS FOR DC VOLTAGES ABOVE NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap
Esterline Power Systems
Original
Leach Relay Reliability TDH-6050 TDH-6051 TDH-6050/6051 TDH-6050/51 MIL-PRF-6106 S301-B6A2 S301-C6A2 M300-D4A

FLS300

Abstract: Tai Shing relay date code marking POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , and many other applications where power switching and high reliability are required over a wide , CONTRASTING BEAD .200 TYPICAL CONTRASTING BEAD TIME DELAY RELAY DE-ENERGIZED OUTPUT ENERGIZED , CONTACTS FOR DC VOLTAGES ABOVE NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap
Esterline Power Systems
Original
FLS300 Tai Shing relay date code marking Tai Shing date code marking TDH-6060/6061 TDH-6060/61 301-D4F/-K 301-D4E/-J MIL-S-12883/41 S300-A1B3

m302 relay

Abstract: TDH-6050 POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , applications where power switching and high reliability are required over a wide temperature range. North , CONTRASTING BEAD TIME DELAY RELAY DE-ENERGIZED OUTPUT DETAIL VIEW A ENERGIZED DETAIL VIEW B ALL , of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap, maximum voltage capabilities of the relay contact system, and the contact material. The most
Leach International
Original
m302 relay S301-B1A2 S301-C1A2 MIL-S-12883/41B S300-A8A8 S301-B8A8 S301-C8A8

S301-B1A2

Abstract: m302 relay POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B S301 15.24 10.16 5.08 3 5.08 B A X1 12.68 DEPTH 9 , other applications where power switching and high reliability are required over a wide temperature range , CONTRASTING BEAD .200 TYPICAL CONTRASTING BEAD TIME DELAY RELAY DE-ENERGIZED OUTPUT ENERGIZED , CONTACTS FOR DC VOLTAGES ABOVE NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap
Leach International
Original
S302-D8A8 S300-A9A8 S301-B9A8 S301-C9A8 S302-D9A8 M301-D4F/-K

TDH-6070

Abstract: m300d POSITION, TOLERANCE SEE CODE B FOR M300 RELAY POSITION, TOLERANCE SEE CODE B FOR M302 RELAY CODE B , power switching and high reliability are required over a wide temperature range. North America 6900 , NOMINAL RATING N°101 To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap, maximum voltage capabilities of the relay contact system, and the contact material. The most common method is to derate the
Leach International
Original
TDH-6070 S30-1 fd300 M301-D4F/-J M302-D4A/ 302-D4A/ MIL-S-12883/41C

s401 diode

Abstract: relay lre M401 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Non latching hermetically sealed relay , Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles 100,000 cycles 20,000 , VOLTAGE Date of issue: 6/00 -3- Page 2 of 2 Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows them to create magnetic forces which are , effecting contact life and reliability. Therefore, it is very important to have a clear understanding of
Leach International
Original
CECC16101-019 s401 diode relay lre S400-A1B3 T402 m400 leach

Leach relay M400

Abstract: designation_| | | 2-Mating relay (M300, M301, M302, M400, M401_| | 2-Hardware (0 , M400 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Polarized, non latching hermetically sealed relay 4 PDT Contact arrangement Coil supply Direct current Meets the requirements , Hermetically sealed, corrosion protected metal can Intrinsically safe relay APPLICABLE SOCKETS: S400 SC40 , DEVICES FOR RELAY COILS The inductive nature of relay coils allows them to create magnetic forces which
Leach International
Original
M835636/15 CECC16303-802
Abstract: designation_| | | 2-Mating relay (M300, M301, M302, M400, M401_| | 2-Hardware (0 , M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay 4 PDT Contact arrangement Meeting the Requirements of MIL â'" R â'" 6106/51 MIL â , sealed, corrosion protected metal can Intrinsically safe relay APPLICABLE SOCKET: S402 SC40 , SUPPRESSOR DEVICES FOR RELAY COILS The inductive nature of relay coils allows them to create magnetic Leach International
Original

M400 relay

Abstract: m400 leach SC 300 01 1-Basic socket snap lock designation_| | | 2-Mating relay (M300, M301, M302 , M400 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Polarized, non latching hermetically sealed relay 4 PDT Contact arrangement Coil supply Qualified to Direct current M835636/15 and /16 , protected metal can Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum operating cycles , : 6/00 -3- Page 2 of 2 Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The
Esterline Power Systems
Original
M400 relay

relay m402

Abstract: Leach relay M402 _| | | 2-Mating relay (M300, M301, M302, M400, M401_| | 2-Hardware (0=less hardware, 1 , M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay Contact arrangement 4 PDT Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS , 115 Vdc - 400 Hz 80 grams max 26 x 25.7 x 26 Intrinsically safe relay CONTACT ELECTRICAL , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows
Esterline Power Systems
Original
relay m402 Leach relay M402

M402

Abstract: M300 relay M402 ENGINEERING DATA SHEET RELAY - LATCH 4 PDT, 10 AMP Polarized, latching hermetically sealed relay Contact arrangement 4 PDT Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS , Vdc - 400 Hz 80 grams max 26 x 25.7 x 26 Intrinsically safe relay CONTACT ELECTRICAL , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows , also slow down the opening of contacts, adversly effecting contact life and reliability. Therefore, it
Leach International
Original
M402 M402 leach M402 relay

relay m400

Abstract: m400 leach M400 ENGINEERING DATA SHEET RELAY - NONLATCH 4 PDT, 10 AMP Polarized, non latching hermetically sealed relay 4 PDT Contact arrangement Coil supply Meets the requirements of Qualified to Direct current , , corrosion protected metal can Intrinsically safe relay CONTACT ELECTRICAL CHARACTERISTICS Minimum , Application notes SUPPRESSOR DEVICES FOR RELAY COILS N°007 The inductive nature of relay coils allows , also slow down the opening of contacts, adversly effecting contact life and reliability. Therefore, it
Leach International
Original
relay m400 M400B
Showing first 20 results.