500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
J2014001L401 GE Critical Power GP100, 3&934;-480, RS485 communications, add-on stand-alone shelf, configured for slot 3, hardware and shelf interconnect included
J2014001L402 GE Critical Power GP100, 3&934;-480, RS485 communications, controller slot, LAN, RJ45 terminations, configured for slot 3
J2014001L422N GE Critical Power GP100, 3&934;-480, RS485 communications, controller slot, RJ45 terminations, includes a L401 and a L402 shelves in the same enclosure. Hardware included
J2014004 GE Critical Power Compact Power Line Shelves, RS485 shelf for the CP3500 rectifier
SRS-4-850 Bivar Inc SRS-4-850
USB-RS485-WE-1800-BT FTDI Chip Wire And Cable, 6 Conductor(s), 24AWG, 5V, Communication Cable, ROHS COMPLIANT

RS485 optical

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: module type SPA-ZC2 is used for the connection RS485/optical SPA bus. The bus connection module SPA-ZC2 , the SPACOM system consists of optical fibres, bus connection modules and the SPA protocol. Physically the SPA bus is a loop of optical fibres, either plastic or glass fibres. The functional units of the , signals of the units to optical signals for the SPA bus or, vice versa, the optical signals of the SPA bus , for a maximum of five optical loops and type SPA-ZC20 twenty transmitter/receiver pairs for twenty -
OCR Scan
1MDB11010-EN abb spad 330 SPAJ 120 SPAJ 140 spam 150 spad 330 SPAJ 120 c
Abstract: star line. Use as: ­ Optical fiber T-coupler with RS-485 branch cable (Figure 03) for connection , the optical range. ­ As an RS-485/optical fiber star distributor (Figure 04) to split RS-485 , . Optical fiber (OF) Optical fiber (OF) RS-485 Figure 02 All current bus topologies can be set up on in the optical fiber network: line, tree or star structure. Optical fiber (OF) RS-485 up to 31 devices Figure 03 up to 31 devices RS-485 multipoint Optical fiber (OF Phoenix Contact
Original
converter rs485 modbus profibus danbus DANFOSS ps 4 Endress Hauser cable modbus RS-485 MERLIN GERIN split db PSM-EG-RS485W2/FO-T/G PSM-EG-RS485W2/FO-E/G PSM-EG-RS485W2/FO PSM-EG-RS-485W2/FO-T/G
Abstract: transmits and receives high-quality, 2-Wire or 4-Wire RS485 data on dual multimode optical fibers. Designed , FEATURES: · RS-485 Repeater · Diagnostic: Video, Optical Presence, Power, and Bi-Directional Transmit , Series transmits, receives, and repeats highquality, RS485 data on dual multimode optical fibers , Series transmits, receives, and repeats highquality, RS485 data on dual multimode optical fibers , 485 SERIES MULTIMODE SINGLEMODE RS485 Transceiver Data System D FEATURES: · RS-485 American Fibertek
Original
PS-12 MX-485-2 MX-485-4 RX-485-2 RX-485-4 MX-485-4T RS-485 card American Fibertek 485T MX SERIES CONNECTOR SR-20/1
Abstract: 10Mbps 2K x8 1 - 508 bytes 255 nodes None x86/68XXX/SH etc HYC2000 RS-485 Optical SMSC HYCs RS-485 Optical SMSC HYCs RS-485 Optical SMSC HYCs RS-485 Optical SMSC HYCs RS-485 , SMSC HYCs RS-485 Optical CAN Transceiver 156.25Kbps - 5Mbps 1K x8 1 - 253/125/61/29 bytes 3/7/15/31 nodes 3 ports x86/68XXX/SH etc SMSC HYCs RS-485 Optical CAN Transceiver ARCNET HYBRID , N/A 8 bytes 15 nodes N/A N/A SMSC HYCs RS-485 Optical CAN Transceiver ARCNET HUB HYC4000 Standard MicroSystems
Original
COM20019I COM20020I COM20022I 48TQFP TMC2074 HYC2000-R HYC5000 hyc5000 smsc optical CAN transceiver HYC9088A STAR RAM 28PLCC/48TQFP 28PLN/48TQN
Abstract: www.litton-ps.com RS-485 Transceiver Single Fiber (2-wire or 4-wire) 850nm / 1300nm version , to 16 dB optical loss range True Tri-State Output Modules are rack mountable using Litton's FO4676 19" Card Cage System ELECTRICAL OPTICAL SPECIFICATIONS Wavelength Connector Launch Power Receiver Sensitivity System Optical Loss Range Data Rate @ BER 109 Connector Operating , , one direction at a time. The FO4765 supports true RS-485 communication on polling systems utilizing Litton Poly-Scientific
Original
litton 800-336-2112 poly-scientific litton litton poly Litton Systems litton CONNECTOR BER109 MSG80033850 FO4765-STAB
Abstract: USB-COMi-SI-M USB to RS-422/485 Adapter (with Optical Isolation & Surge Protection) KEY FEATURES , convenient RS422 / RS485 mode & configuration setting · Data rates: 300 bps to 921.6K bps · IO connection , adds a RS-422, or RS-485 serial communication port to your system. By taking advantage of the USB bus , 4-pin dip switch to set RS-422 or RS-485 mode conveniently, without the need to open the metal , biasing options are available for data transmission lines. Optical isolation and surge protection are EasySync
Original
USB-COMi-SI-M rs485 to db9 connector datasheet rs-422 db9 datasheet of 4-pin DIP switch notes on DB9 for serial communication db9 connector datasheet RS-422/RS-485
Abstract: Optical fiber T-coupler with RS-485 branch cable (Figure 03) for connection to a copper network with a maximum of 31 other devices. ­ As an optical fiber repeater to double the optical range. ­ As an RS-485/optical fiber star distributor (Figure 04) to split RS-485 interfaces into two outgoing optical fiber , optical fiber network: line, star, tree or redundant ring structure. Optical fiber (OF) RS-485 , multipoint Optical fiber (OF) Optical fiber (OF) Optical fiber (OF) RS-485 Figure 02 Figure Phoenix Contact
Original
phoenix contact 24v 8 channel Relay converter rs485 to profibus fiber delay line RD5B
Abstract: lange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7W - RS485 Part number GXM7W , clamping or synchro lange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7W - RS485 , interfaces Shaft with clamping or synchro lange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 , Absolute encoders - bus interfaces Shaft with clamping or synchro lange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7W - RS485 Features â'" Encoder multiturn / RS485 â Baumer
Original
Abstract: Absolute encoders - bus interfaces Shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7W - RS485 Features ­­ Encoder multiturn / RS485 ­­ Optical , flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7W - RS485 Part number , with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7W - , Integration of customer-specific RS485 protocols GXM7W with clamping flange Technical data - electrical Baumer IVO
Original
gxm7W max RS485 GXM7 M23 radial cable rs485 connection Absolute OPTICAL ENCODER
Abstract: Absolute encoders - bus interfaces EX approval ATEX EEx d IIC T6 Optical multiturn encoders 13 bit ST / 12 bit MT X 700 - RS485 Features â'" Encoder multiturn / RS485 / ATEX â'" Optical , Optical multiturn encoders 13 bit ST / 12 bit MT X 700 - RS485 Part number X 700.P 1 2 07 , EX approval ATEX EEx d IIC T6 Optical multiturn encoders 13 bit ST / 12 bit MT X 700 - RS485 , (gas), zone 21 (dust) â'" Galvanic isolation X 700 with RS485 Technical data - electrical ratings Baumer
Original
Abstract: Absolute encoders - bus interfaces End shaft max. ø14 mm Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7S - RS485 Features â'" Encoder multiturn / RS485 â'" Optical sensing â , Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7S - RS485 Dimensions 58 20 M x6 , customer-speciic RS485 protocols GXM7S with end shaft Technical data - electrical ratings Technical data - , ) Initializing time (typ.) 250 ms after power on Protection DIN EN 60529 IP 54 Interface RS485 Baumer
Original
Abstract: Absolute encoders - bus interfaces End shaft max. ø14 mm Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7S - RS485 Features ­­ Encoder multiturn / RS485 ­­ Optical sensing ­­ , shaft max. ø14 mm Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7S - RS485 Part number , shaft max. ø14 mm Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7S - RS485 Terminal , interfaces End shaft max. ø14 mm Optical multiturn encoders 13 bit ST / 12 bit MT, RS485 GXM7S - RS485 Baumer IVO
Original
RS485 bus GXM7S baumer impulse encoder 250 electrical connection torque settings E63076
Abstract: transparently over the fibre optical link via the serial interface RS-232 (ODW-621) or RS-485 (ODW-631). . , optical fibre ODW-621/631 is a fibre optic modem that converts between electrical RS-232 or RS-485 and a , . However, the user is warned not to look directly into fibre optical port or any connected fibre. Care , Westermo Tech support. Fibre connectors are supplied with plugs to avoid contamination inside the optical port. The plug should be fitted when no optical fibre is inserted in the connector, e.g. during Westermo
Original
ODW-600 SE-640 Automatic Railway Gate Control system, automatic in railway system using plc ODW632 Westermo
Abstract: Ethernet Media Converter Fast Ethernet Media Converter 650nm Polymer Optical Fiber 650nm Polymer Optical , Anschluß (optisch), ohne Netzgerät* F-SMA port (optical), without power supply* F-ST Anschluß (optisch), ohne Netzgerät* 54,5 F-ST port (optical), without power supply* 901 RS 232 1K 519 901 RS 232 1K 520 850nm, 120KBit/s, 3000m F-SMA Anschluß (optisch), ohne Netzgerät* F-SMA port (optical , F-ST Anschluß (optisch), ohne Netzgerät* F-ST port (optical), without power supply* 901 RS 232 1K -
Original
232-C SUB-D 9 pol Sub-D 9-pol Sub-D 25-pol sub-d 25 C6091 FST Connectors 100BASE-TX 100BASE-FX 100MB 120KB RS485/422
Abstract: optical axis (4­66) 2 5 7 25mm optical pitch 50mm optical pitch 75mm optical pitch blank P Slave unit PNP outputs blank 12 Stand­alone or slave unit No. of optical axis of the connected slave unit for 25mm optical pitch type: 12, 18, 24, or 30 for 50mm optical pitch type: 06, 09, 12, or 15 for 75mm optical pitch type: 04, 06, 08, or 10 blank L D P 12 ­ L Stand­alone Master , receiver Emitter unit only Receiver unit only Stand­alone Master unit Slave unit Optical -
Original
EN954 relay rs-5 relay b047 diode b047 B047 HS2C BS047 98/336/EEC 98/37/EC UL508
Abstract: advantage of the USB bus, the USB Industrial I/O Adapter makes it easier than ever to add RS-422 or RS485 , multi-drop communications over short and long distance. Optical Isolation & Surge Protection Optical , with 2000 volt DC optical isolation. The optical isolation protects your PC or notebook from spikes and surges on the RS422/485 network, by converting the electrical pulse into an optical signal and , spikes cannot cross the optical link. The RS-422/485 port is protected by surge protector to withstand -
Original
LT 485 8 pin dip 4 pin dip switch 5 pin connector usb connector USB-COMi-SI 2.tx transistor DIP SWITCH 10 PIN
Abstract: serial converters · UK designed & manufactured · Optical isolation available · Automatic turnaround feature on MA485F9 · Automatic data-rate detection · RS485 screw terminal connectors for easy wiring · , RS232 to RS422 or RS485 compliant signals. allowing full duplex RS232 connections to connect directly to a half duplex 2-wire RS485 bus without a requirement for software based Used in pairs, they , operates in the same way as the 485HF9 with the addition Model 485HF9 of optical isolation on the data Amplicon
Original
485F9 rs485 to db9 connector connector db9 rs485 to rs232 conversion 485F9I Current Loop rs232 rs485 to rs232 converter
Abstract: Serial Interfaces for RS-485 and RS-232 Available for ISA, PCI, and PCMCIA Compatible with , -485 Work with RS-485 or RS-422 Communicates with up to 31 devices Automatic transceiver-control mode for 2-wire RS-485 devices Cable lengths to 1.2 km (4,000 ft) AT-232, PCI-232, PCMCIA-232 Work with , performed totally under control of the operating system. Our RS-485 interfaces (AT-485, PCMCIA-485, PCI , RS-485 interface boards use software access to UART registers to control the alternating of transmit National Instruments
Original
SCSI 68 connector PCMCIA serial 16550C RS-232 3.5 jack to db9 pc db9 182845-01 PCI-485 SCSI-68 PCI-485/2 PCI-485/4 PCI-232/2 PCI-232/4
Abstract: -422/485 Surge Protection & Optical Isolation Converter from RS-232 to RS-422/485 Surge Protection & Optical Isolation Beschreibung Description Der EX-47900IS RS-232 zu RS-422/485 Konverter mit Surge Protection und Optical Isolation kann für jeden PC, Workstation oder Server mit einer RS , -422/485 converter with Surge Protection and Optical Isolation is design for your PC, workstation, thin , -422 or RS-485 signals. With the EX-47900IS we include the adapter from 9 pin to 5 pin Terminal Block EXSYS
Original
RS-232 to RS485 converter 4 pin terminal block connector D-Sub 9-pin feMale Connector DB9 Female D-SUB CONNECTOR rs-232 data switch RXD TXD DTR DSR RS232 RS-232/422/485 EX47900IS RS-422/495
Abstract: Maxim > App Notes > Interface Circuits Keywords: RS-485, rs485, tranceivers, EIA-TIA-485, 15kV ESD protected, fail safe, high common-mode voltage, high CMR, fault detection, motor control, optical encoder, high-reliability, ESD protection Apr 01, 2001 APPLICATION NOTE 578 New RS-485 IC Increases System Reliability and Fault Detection in Motor-Control Circuits Abstract: Applying a unique 3-channel RS-485 , three differential channels to handle optical encoder data, ±15kV ESD protection, increased common mode Maxim Integrated Products
Original
MAX3097 MAX3098 application note 26LS31 26LS31 26LS32 application note 26LS32 MAX3097E MAX3098E AN578 APP578
Showing first 20 results.