| Catalog Datasheet Results | Type | Document Tags |
| Abstract: RS-422A-485 DX100/200 DX100/200 DAQSTATION DX DAQSTATION DX ATA Zip DAQSTATION 10BASE-T 10BASE-T Modbus 485 RS-232 RS-232 RS-422-A/ PC DX 10BASE-T 10BASE-T IP TCP/ FTP RS-232 RS-232 RS-422A/485 ATA 440MB 440MB DX Zip IEC529-IP65 IEC529-IP65 DX DAQLOGGER DAQEXPLORER DX100 DX100 DX200 DX200 100MB 100MB CMRR NMRR AX100 AX100 AX100 AX100 IT RECORDER IT RECORDER AX100 AX100 Modbus RS-422-A/485 PC CMRR NMRR NR1800 NR1800 NR1800 NR1800 RS485 RS485 FLASH RAM ... | Original |
14 pages, |
DX100 IP65 PIN CONFIGURATION 7410 RECORDER RS-232 rs-422 rs485 IEC529-IP65 NR1800 RS485 MODBUS RS-232 datasheet IEC529 DX200 modbus circuit DX100/200 10BASE-T DX100/200 abstract |
| Abstract: ts^in ooGoaas TBT â- wc^r-is-ys-os' NM422AD NM422AD 5 Volt only Dual RS232C RS232C to RS422A Transceiver NEUPORT , RS422A Standards â-¡ Two full-duplex links â-¡ DIL 0.5" package â-¡ Low profile â-¡ Low power consumption description RS232C RS232C RX IN1 4 A1RX 5 f TX OUT 1 6 RS232C RS232C) I TX OUT 2 7 VCC 82 TX I RS422A A2TX / DRIVER RX IN2 RS232C RS232C B1 RX RS422A 11 GND The NM422AD NM422AD is a device tor connecting and converting data levels between the RS422A standard and the RS232C RS232C standard. RS422A uses balanced transmission lines and ... | OCR Scan |
4 pages, |
NM422AD 300C EIA-RS-232C rs422a EIA-RS232C rs232c RS-422A RS232C RS422A NM422AD abstract |
| Abstract: NM422AD NM422AD Dual RS232C RS232C to RS422A Transceiver â-¡ Bidirectional transceiver Duai-ln-Jine Package (top view) â-¡ 5 Volt only operation â-¡ Meets EIA - RS232C RS232C and RS422A & RS485 RS485 standards RS422A RS232C RS232C Vcc B , for balanced transmission lines and meets EIA standard RS422A & RS485 RS485 for the bus port connection. At , channel and data transmit channel both RS232C RS232C compatible connected as input and output to the RS422A , 300C 33 NM422AD NM422AD Dual RS232C RS232C to RS422A Transceiver RS232C RS232C Receiver electrical specifications over ... | OCR Scan |
10 pages, |
RS422A RS-422A RS-422-A NM422A 300C NM232 rs232c rs422a NM422AD RS232C RS485 NM422AD abstract |
| Abstract: Isolated 422/485 Communication Card AR-B9012 AR-B9012 Features 2 serial 16C550 16C550 ports (16C550 16C550 w/16 byte FIFO for option) Interface type: RS-422A or RS-485 RS-485 Baud Rate: up to 115.2K bps Can be set from COM1 to COM8 Port Signals: TXD, RXD, CTS and RTS Isolation Voltage: 500VDC 500VDC Maximum transfer distance , four wire operation Dimensions: 175mm x 107mm Specifications General Interface Type RS-422A or , RS-422A 4K ohm; RS-485 RS-485 12K ohm Termination Resistor 120 ohm Signal Isolator PC900 PC900 for TXD and ... | Original |
1 pages, |
uart 16c550 SN75174 SN75173 SN75172 4N35 TXD RXD SN75175 16c550 datasheet PC900 120 OHM RESISTOR can bus AR-B9012 RS-422A 16c550 16C550 AR-B9012 abstract |
| Abstract: RS-232C/RS-422A Converter is connected directly to RS-232C RS-232C port A or B of the PT, and converts RS-232C RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix 9 Standard Models can be used. A , The NS-AL002 NS-AL002 is an uninsulated RS-232C/RS-422A Converter. Therefore, if differences in ground potential or effects from noise are concerns, it is recommended that an insulated NT-AL001 NT-AL001 RS-232C/RS-422A , NT-series PTs or PLCs. Communications Specifications · RS-422A Interface Item Specifications Baud ... | Original |
8 pages, |
CONNECTOR 5 PIN Round rs485 RS-442A RS-422A NT-AL002 host link OMRON Operation Manual NSAL002 weight d-sub 62 pins CJ1W-CIF11 NT-AL001 NS-AL002 RS-232C/RS-422A RS-232C RS-422A/RS-485 NS-AL002 abstract |
| Abstract: RS422A Transceiver O Bidirectional Transceiver â-¡ 5 Volt only operation â-¡ Meets EIA - RS232C RS232C and RS422A , (TOP VIEW) RS422A RS232C RS232C Vcc B A ^O 16 15 14 12 °_9 3 4 5 RE DE RX, RS232C RS232C GND description The NM422A NM422A Transceiver is designed for balanced transmission lines and meets EIA standard RS422A & RS485 RS485 for , output to the RS422A compatible driver and receiver. absolute maximum ratings over operating free-air , to RS422A Transceiver NEUPORT COMPONENTS LTD MÃ-E D RS232C RS232C Receiver electrical specifications over ... | OCR Scan |
4 pages, |
RS422A RS232C NM422A 300C RS-422A RS485 NM422A abstract |
| Abstract: SYSMAC Option RS-422A Converter CJ1W-CIF11 CJ1W-CIF11 CSM_CJ1W-CIF11 CJ1W-CIF11_DS_E_1_1 The RS-232C RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. · The CJ1W-CIF11 CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C RS-232C port and converts RS-232C RS-232C to RS-422A/485. CJ1W-CIF11 CJ1W-CIF11 Features · You can use RS-422A/RS-485 by connecting the converter to built-in RS-232C RS-232C port of the CS/CJ series , Information Name Specifications Model Standards RS-422A Converter Converts RS-233C RS-233C to RS-422A ... | Original |
6 pages, |
W393 OMRON plc programming manual pin diagram of RS 485 omron plc cs manual OMRON DIP switch 485 omron omron cj1m operation manual NT-AL001 RS-232C application sysmac cj1m RS-422A CJ1W -SCU41-V1 RS-422A abstract |
| Abstract: MITSUBISHI M5M34050P/FP M5M34050P/FP M5M34051P/FP M5M34051P/FP DUAL RS-422A TRANSCEIVER DESCRIPTION The , differential receivers fulfilling the RS-422A EIA Standards. FEATURES [Common] • Single 5V power supply • , ^DIGITAL ASSP> M 5 IVI34050P/ IVI34050P/ F P M5M34051P/FP M5M34051P/FP DUAL RS-422A TRANSCEIVER ABSOLUTE MAXIMUM RATINGS (Ta=-20 , MITSUBISHI IVI 5 M34050P/F M34050P/F P M5M34051P/FP M5M34051P/FP DUAL RS-422A TRANSCEIVER , M5M34051P/FP M5M34051P/FP DUAL RS-422A TRANSCEIVER SWITCHING CHARACTERISTICS (vcc=5v and ra=25c ) ... | OCR Scan |
5 pages, |
RS-422A M5M34051 RS-422A M5A26LS32AP M3405 180I2 M5M34051P M5M34051 M5A26LS31 M5A26LS31P M5M34050P/FP M5M34051P/FP M5M34050P/FP abstract |
| Abstract: Multipoint Systems, EIA, Washington, D.C. 2. EIA Standard EIA-422-A EIA-422-A (EIA RS-422-A), Electrical , , D.C. EIA-485 EIA-485 Fig. 4 () 2. EIA Standard EIA-422-A EIA-422-A (EIA RS-422-A), Electrical Characteristics of ... | Original |
4 pages, |
RS485 standard RS-422-A EIA-422A DS3696 AN-759 eia485 EIA-485 EIA-422-A EIA485 EIA-485 abstract |
| Abstract: : Absolute outputs 1 and 2 CQM1H-SCB41 CQM1H-SCB41 Serial Communications Board RS-232C RS-232C port RS-422A/485 port , Communications One RS-232C RS-232C port and one RS-422A/485 port Board CQM1H-CPU51/61 CQM1H-CPU51/61 CPU Unit Inner Board slot 1 , and ring counting modes are supported. � The input can be a voltage input or an RS-422A line driver , RS-422A line driver (AM26LS31 AM26LS31 or equivalent) Phase A and B Phase Z 10 mA typical 13 mA typical ON , RS-232C RS-232C port and an RS-422A/485 port. The RS-422A/485 port supports 1:N connections (protocol macro or ... | Original |
12 pages, |
AD041 CQM1H-SCB41 CQM1H-ABB21 CQM1 Programming Instructions Omron Programming Console CQM1 Omron CQM1H SUPPORT SOFTWARE Omron Programming Console CQM1 pro OMRON CQM1H-mab42 SCB41 CQM1H-CPU61 CQM1H-CPU51 switches CQM1-AD041 CQM1H-CPU51 CQM1HCPU61 CQM1H-CPU51 abstract |
| Abstract: Connection to Mitsubishi A (Computer Link) RS-232C RS-232C RS-422A Connection to Mitsubishi FX (Programming , ) NT620S-ST211-E NT620S-ST211-E NT620C-ST141-E NT620C-ST141-E RS-232C RS-232C f f f RS-422A RS-232C RS-232C f f: Direct connection Via RS-232C/RS-422A convertor unit : Connection not possible (*1) In order to use NT30/NT30C NT30/NT30C, NT620S NT620S , an RS-422A terminal block; some computer link modules have an RS-232C RS-232C connector and some have an RS-422A terminal block. This section describes the methods for connection with these connectors and ... | Original |
51 pages, |
FX2-32MR omron NT620C-ST141-E Melsec fx2 FX1-64MR NT600S FX0-20MT nt20s-st121 FX0N-40MT FX2-16MR FX2-80MR FX0N-60mr fx1-80mr NT600S-ST121-EV3 FX0-14MR-D V042-E1-1 V042-E1-1 abstract |
| Abstract: fiber.book : sec01.fm Page 7 Thursday, June 22, 2000 11:40 AM 11 0 C o n n e cto r S yste m O u tle t A d a p te r Applications Within the Private Network RS-232-D RS-232-D, RS-422-A, and IBM 3270 Schematic Overview W o rksta tio n M u ltip le xe r L IU M u ltip le xe r 11 0 C o n n e cto r S yste m ADAPTER IB M 3 2 7 0 C o n tro l U n it H o st N O T E : T h is illu stra tio n re p re se n ts a n o ve rvie w o f p rim ary e q u ip m e n t re q u ire d in a typ ... | Original |
1 pages, |
RS-422-A RS-232-D RS-232-D abstract |
| Abstract: . . SECTION 5 Connecting to the Host from the RS-422A/485 Port . . . . 5-1 5-2 Connecting to the Host's RS-422A/485 Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , using the RS-422A/485 port of the PT. Section 6 describes the operation of the System Menu, focusing on , and SRM1. However, connection is not RS-232C RS-232C cable (15 m max.) An RS-422A/485 cable (500 m max.) can be connected through an RS-232C/RS-422A Adapter. Bar code reader Bar codes can be read as ... | Original |
222 pages, |
NS-AL002 OMRON CQM1H-CPU11 C200H lk201 OMRON Operation Manual OMRON CQM1H-CPU51 INSTALLATION MANUAL omron plc CQM1H CPU 51 configuration CQM1H-CPU51 switches 24 VDC CIRCUIT BREAKER NT21-ST121-E CQM1H-CPU21 dip switches ladder diagram omron plc barcode reader CQM1H-CPU51 programming manual V068-E1-01 V068-E1-01 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| Product Folder:SN7534051 SN7534051 SN7534051 SN7534051, DUAL DIFFERENTIAL DRIVER/RECEIVER PAIRS(RS-422A) >> Semiconductor Home > Products > Analog & Mixed-Signal > Interface > Transmitters and Receivers > SN7534051 SN7534051 SN7534051 SN7534051, DUAL DIFFERENTIAL DRIVER/RECEIVER PAIRS(RS-422A) Device Status: Active > Pricing/Samples/Availability > Application Notes > Related Documents > Development Tools > Applications To view the following documents, Acrobat Reader 3.x is required. To download a document to your hard drive, right www.datasheetarchive.com/files/texas-instruments/data/www.ti.com/sc/docs/products/analog/sn7534051.html |
Texas Instruments | 29/01/2000 | 10.66 Kb | HTML | sn7534051.html |
| Product Folder:SN7534051 SN7534051 SN7534051 SN7534051, DUAL DIFFERENTIAL DRIVER/RECEIVER PAIRS(RS-422A) >> Semiconductor Home > Products > Analog & Mixed-Signal > Interface > Transmitters and Receivers > SN7534051 SN7534051 SN7534051 SN7534051, DUAL DIFFERENTIAL DRIVER/RECEIVER PAIRS(RS-422A) Device Status: Active > Pricing/Samples/Availability > Application Notes > Related Documents > Development Tools > Applications To view the following documents, Acrobat Reader 3.x is required. To download a document to your hard drive, right www.datasheetarchive.com/files/texas-instruments/data/wwwti~1.com/sc/docs/products/analog/sn7534~1.htm |
Texas Instruments | 28/01/2000 | 10.66 Kb | HTM | sn7534~1.htm |
| SN75179A SN75179A SN75179A SN75179A DIFFERENTIAL DRIVER AND RECEIVER PAIR SLLS123B SLLS123B SLLS123B SLLS123B - JUNE 1984 - REVISED FEBRUARY 1993 Copyright © 1993, Texas Instruments Incorporated features Meets EIA Standards RS-422A, RS423A RS423A RS423A RS423A, and CCITT Recommendations V.11 and X.27 Bus Voltage Range . . . -7 V to 12 V Positive and Negative Current Limiting Driver Output Capability . . . 60 mA Max Driver Thermal balanced transmission line applications, and meets EIA Standards RS-422A, RS-423A RS-423A RS-423A RS-423A, and CCITT www.datasheetarchive.com/files/texas-instruments/data/html/slls123b.htm |
Texas Instruments | 31/05/1997 | 1.82 Kb | HTM | slls123b.htm |
| 2/3 Inch 1024 x 1024 Pixel, Digital Output KP-F1 10 The KP-FI 10 is a monochrome, high resolution, progressive scan camera with dual channel RS-422A 10 bit digital outputs. An excellent choice for machine vision and imaging systems, the camera features a 1.05 million pixel CCD array with square pixels, and a real time 30 frame per second digital video output. Equal horizontal and .0 V p-p 75 ohms Digital: RS-422A 10 bit dual ch. 24.3MHz/ ch. Power: 12 volts DC 800 ma Size www.datasheetarchive.com/files/hitachi/hdata/www_data/data/camera/kpf/kpf110.txt |
Hitachi | 04/10/1997 | 1.49 Kb | TXT | kpf110.txt |
| SN55LBC175 SN55LBC175 SN55LBC175 SN55LBC175 QUADRUPLE LOW-POWER DIFFERENTIAL LINE RECEIVER SGLS083 SGLS083 SGLS083 SGLS083 - MARCH 1995 Copyright © 1995, Texas Instruments Incorporated features Meet EIA Standards RS-422-A, RS-423-A RS-423-A RS-423-A RS-423-A, RS-485 RS-485 RS-485 RS-485, and CCITT V.11 Designed to Operate With Pulse Durations as Short as 20 ns Designed for Multipoint Transmission on Long Bus Lines in Noisy Environments Input Sensitivity . . . ±200 m is designed to meet the requirements of the EIA Standards RS-422-A, RS-423-A RS-423-A RS-423-A RS-423-A, RS-485 RS-485 RS-485 RS-485, and CCITT V.11 www.datasheetarchive.com/files/texas-instruments/data/html/sgls083.htm |
Texas Instruments | 26/06/1997 | 2 Kb | HTM | sgls083.htm |
| SN95176B SN95176B SN95176B SN95176B DIFFERENTIAL BUS TRANSCEIVER SGLS026A SGLS026A SGLS026A SGLS026A - MARCH 1989 - REVISED JUNE 1995 Copyright © 1995, Texas Instruments Incorporated features Bidirectional Transceiver Suitable for Most EIA Standards RS-422-A and RS-485 RS-485 RS-485 RS-485 Applications Designed for Multipoint Transmission on Long Bus Lines in Noisy Environments 3-State Driver and Receiver Outputs Individual Driver and bus transmission lines. The transceiver is suitable for most RS-422-A and RS-485 RS-485 RS-485 RS-485 applications to the www.datasheetarchive.com/files/texas-instruments/data/html/sgls026a.htm |
Texas Instruments | 31/05/1997 | 2.6 Kb | HTM | sgls026a.htm |
| SN55LBC173 SN55LBC173 SN55LBC173 SN55LBC173 QUADRUPLE LOW-POWER DIFFERENTIAL LINE DRIVER SGLS081 SGLS081 SGLS081 SGLS081 - MARCH 1995 Copyright © 1995, Texas Instruments Incorporated features Meets EIA Standards RS-422-A, RS-423-A RS-423-A RS-423-A RS-423-A, RS-485 RS-485 RS-485 RS-485, and CCITT V.11 Designed to Operate With Pulse Durations as Short as 20 ns Designed for Multipoint Bus Transmission on Long Bus Lines in Noisy Environments Input Sensitivity is designed to meet the requirements of the EIA standards RS-422-A, RS-423-A RS-423-A RS-423-A RS-423-A, RS-485 RS-485 RS-485 RS-485, and CCITT V.11 www.datasheetarchive.com/files/texas-instruments/data/html/sgls081.htm |
Texas Instruments | 26/06/1997 | 2.02 Kb | HTM | sgls081.htm |
| SN75177B SN75177B SN75177B SN75177B, SN75178B SN75178B SN75178B SN75178B DIFFERENTIAL BUS REPEATERS SLLS002C SLLS002C SLLS002C SLLS002C - D2606 D2606 D2606 D2606, JULY 1985 - REVISED FEBRUARY 1993 Copyright © 1993, Texas Instruments Incorporated features Meets EIA Standards RS-422-A and RS-485 RS-485 RS-485 RS-485 and CCITT Recommendations V.11 and X.27 Designed for Multipoint Transmission on Long Bus Lines in Noisy Environments 3-State Outputs Bus Voltage Range . . . -7 V to 12 V for balanced transmission bus line applications and meet EIA Standard RS-422-A and RS-485 RS-485 RS-485 RS-485 and CCITT www.datasheetarchive.com/files/texas-instruments/data/html/slls002c.htm |
Texas Instruments | 31/05/1997 | 2.39 Kb | HTM | slls002c.htm |
| SN65LBC175 SN65LBC175 SN65LBC175 SN65LBC175, SN75LBC175 SN75LBC175 SN75LBC175 SN75LBC175 QUADRUPLE LOW-POWER DIFFERENTIAL LINE RECEIVERS SLLS171 SLLS171 SLLS171 SLLS171 - OCTOBER 1993 Copyright © 1993, Texas Instruments Incorporated features Meet or Exceed the EIA Standards RS-422-A, RS-423-A RS-423-A RS-423-A RS-423-A, RS-485 RS-485 RS-485 RS-485, and CCITT Recommendation V.11 Designed to Operate With Pulse Durations as Short as 20 ns Designed for Multipoint Transmission on Long Bus Lines in Noisy designed to meet the requirements of the EIA standards RS-422-A, RS-423-A RS-423-A RS-423-A RS-423-A, RS-485 RS-485 RS-485 RS-485, and CCITT Recommendation www.datasheetarchive.com/files/texas-instruments/data/html/slls171.htm |
Texas Instruments | 31/05/1997 | 2.26 Kb | HTM | slls171.htm |
| SN75ALS181 SN75ALS181 SN75ALS181 SN75ALS181 DIFFERENTIAL DRIVER AND RECEIVER PAIR SLLS152 SLLS152 SLLS152 SLLS152 - DECEMBER 1992 Copyright © 1992, Texas Instruments Incorporated features Meets EIA Standards RS-422-A, RS-485 RS-485 RS-485 RS-485, and CCITT Recommendations V.11 and X.27 Low Supply Current Requirements 30 mA Max Driver Output Capacity . . . ±60 mA Thermal Shutdown Protection Driver Common-Mode Output Voltage Range of -7 V to transmission lines and meets EIA Standards RS-422-A and RS-485 RS-485 RS-485 RS-485, and CCITT recommendations V.10, V.11, X.26, and www.datasheetarchive.com/files/texas-instruments/data/html/slls152.htm |
Texas Instruments | 31/05/1997 | 2.06 Kb | HTM | slls152.htm |