Part Manufacturer Description Datasheet BUY
1600092468A GE Critical Power J2014003L002 I2C SHELF FOR CP300 visit GE Critical Power
1600098385A GE Critical Power J2014003L001A I2C SHELF FOR CP30 visit GE Critical Power
J2014003L001A GE Critical Power J2014003L001A I2C SHELF FOR CP30 visit GE Critical Power
J2014003L002 GE Critical Power J2014003L002 I2C SHELF FOR CP300 visit GE Critical Power
J2014003 GE Critical Power Compact Power Line Shelves, Dual I2C shelves for the CP3500 rectifier visit GE Critical Power
PIM400KZ GE Critical Power PIM400 Series; ATCA Board Power Input Module, -36 to -75 Vdc; 400W/10A, I2C Digital Interface visit GE Critical Power

Profibus circuit diagram

Catalog Datasheet MFG & Type PDF Document Tags

profibus connector

Abstract: E123528 Connectors for PROFIBUS SUBCON-PLUS ­ SUBCON-PLUS-PROFIB/(AX/). Function block diagram 6 VP 5 , Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/. 1. Description The new SUBCON-PLUS-PROFIB/. SUB-D series has been specifically designed for use in PROFIBUS systems up to 12 Mbps. It , . The range consists of six quick connectors - the right solution for every PROFIBUS application: ­ , PROFIBUS cables with solid copper wires. Connectors with screw-cage terminal blocks (./SC) are
Phoenix Contact
Original

profibus schematic

Abstract: 61158-2 . 7 PROFIBUS Node Block Diagram . 8 , PROFIBUS Load The equivalent circuit shown in Figure 3 is not representative of the PROFIBUS network in , external signals couple onto the bus line. Figure 10 shows a typical PROFIBUS block diagram of the RS , Regulator DB9 Connector DR010505 RS485_GND Figure 10. PROFIBUS Node Block Diagram 8 , Application Report SLLA177A ­ May 2005 ­ Revised April 2006 PROFIBUS Electrical-Layer Solutions
Texas Instruments
Original
profibus schematic 61158-2 profibus communication schematic Profibus profibus connector A114A cnc RS-485

profibus connector

Abstract: Profibus circuit diagram Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/. 1. Description The new SUBCON-PLUS-PROFIB/. SUB-D series has been specifically designed for use in PROFIBUS systems up to 12 Mbps. It , . The range consists of six quick connectors - the right solution for every PROFIBUS application: ­ , PROFIBUS cables with solid copper wires. Connectors with screw-cage terminal blocks (./SC) are , all standard PROFIBUS cables with an outside diameter of 8 mm (0.315 in.) (type A and B). If a Fast
Phoenix Contact
Original
Profibus circuit diagram Phoenix contact subcon 9 connector circuit diagram of rocker switch 6 pin

XR5487

Abstract: SN75179 application TIMING DIAGRAM 1 FIGURE 10. DRIVER ENABLE AND DISABLE TIME TEST CIRCUIT 2 Vcc RL = 500 Y 0 or Vcc , XR5486E-5487E-5488E ULTRA HIGH SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND , Unit Load, 256 transceivers on bus · Driver short circuit current limit and thermal shutdown for , maintain high impedance in shutdown or when powered-off. FIGURE 1. TYPICAL APPLICATION CIRCUIT DE DE , SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND +/-15KV ESD-PROTECTION REV. 1.0.0
Exar
Original
EN61000-4-2 XR5487 SN75179 application sn75180 stub timing diagram of RS 485 XR5486E-XR5488E XR5488E TIA/EIA-485 TIA/EIA-422

SN7517

Abstract: sn75179 -422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND +/-15KV ESD-PROTECTION FIGURE 3. DRIVER DC TEST CIRCUIT , XR5486E-5488E ULTRA HIGH SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND + , short circuit current limit and thermal shutdown for overload protection · Low Current 1A shutdown , APPLICATION CIRCUIT DE DE XR5488E DI XR5488E B B STUB RT DI RT A A RO RO , XR5486E-5488E ULTRA HIGH SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND +/-15KV
Exar
Original
IEC-61000-4-2 SN7517 sn75179 max 485 repeater SN75176 XR5486 XR5488EID-F

Pt 100 RTD Siemens

Abstract: circuit diagram for profibus connector siemens mounted temperature transmitters, PROFIBUS PA 10/11-8.70 EN Block diagram Offset Secondary_Value , TF 212 / TF 212-Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD , : ATEX ­ Explosion Proof version (acc. to divisions): FM, CSA s Output ­ PROFIBUS PA profile V3 , ® TF 212 / TF 212-Ex Field mounted temperature transmitters, PROFIBUS PA 10/11-8.70 EN Technical data Output General characteristics Digital output signal PROFIBUS PA profile V3.0 type A
ABB Automation
Original
Pt 100 RTD Siemens circuit diagram for profibus connector siemens Siemens pt100 temperature transmitter Siemens PT100 temperature sensor RTD Thermocouple Type L Thermocouple Type g 212-E Z-20158

Pt 100 RTD Siemens

Abstract: Thermocouple Type L Data Sheet 10/11 8.26 EN FieldIT Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS , , 3, 4 wire circuit) ­ Thermocouples ­ Resistance remote signalling units (0.400 , 0.4000 ) ­ Voltages, mV ( 15.+115 mV) Output ­ PROFIBUS PA profile V3.0, type A and B ­ Bus design acc. to IEC , diagnostics Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD), Thermocouples , B, C, D, E, J, K, L, N, R, S, T, U Digital output signal PROFIBUS PA profile V3.0, type A and B
ABB Automation
Original
siemens 611 thermocouple Pt 200 RTD Siemens RTD MODULE Siemens type k thermocouple input characteristics profile siemens thermocouple pt 100 temperature sensor RTD abb TF12/TF12-E DSV401 TF12/TF212

EN50170

Abstract: DIN19245 D OUT R CL 50pF Z 3.3V Driver Propagation Delay Time Test Circuit and Timing Diagram , and Disable Times Test Circuit and Timing Diagram 0 or VCC DI Y D OUT Z GENERATOR S1 , Corporation DESCRIPTION Driver Enable and Disable Times Test Circuit and Timing Diagram VCC 0 OR VCC DI , SP1486E Solved by TM +5V, 20Mbps PROFIBUS RS485/RS422 Transceivers Advanced Failsafe, 1/8th Unit Load, ±15kV ESD-Protected FEATURES +5V · Recommended for PROFIBUS applications · High
Sipex
Original
EN50170 DIN19245 TIA485 sipex 485 ec PROFIBUS/RS485 SP1486EEN-L SP1486EMN-L SP1486EEN-L/TR SP1486EEN/TR

timing diagram of RS 485

Abstract: xr5486 9. DRIVER ENABLE DISABLE TIMING DIAGRAM 1 FIGURE 10. DRIVER ENABLE AND DISABLE TIME TEST CIRCUIT , TEST CIRCUIT FIGURE 13. RECEIVER PROPAGATION DELAY TIMING DIAGRAM A B 1.5V OUT t PHL t PLH +1V , CIRCUIT FIGURE 15. RECEIVER ENABLE AND DISABLE TIMING DIAGRAM 1 S1 is open, S2 is closed, S3 = 1.5V , ULTRA HIGH SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND +/-15KV , on bus · Driver short circuit current limit and thermal shutdown for overload protection · Low
Exar
Original

RLM01

Abstract: ABB rlm01 manual : Ideal combination (schematic diagram) Automation system / Master PROFIBUS DP T Fieldbus , : Possible alternative (schematic diagram) Automation system / Master PROFIBUS DP T Fieldbus , Installation Guidelines, chapter 3.3.3 PROFIBUS PA: Ideal combination (schematic diagram) Power supply , grounding in the Non-Ex area (schematic diagram) Power supply cable screened Field device PROFIBUS PA , Data sheet PROFIBUS Installation suggestion 10/63-0.40 EN PROFIBUS DP - Passive
ABB Automation
Original
RLM01 ABB rlm01 manual NDE220-NO HD2-FBPS-1500 ACC-MB-HGC NDJ132-NO M00553 DTD100 3KXN040000R1001

SN75179 application

Abstract: pin diagram of RS 485 DISABLE TIMING DIAGRAM 2 FIGURE 12. RECEIVER PROPAGATION DELAY TEST CIRCUIT 1.5V S3 -1.5V S1 , XR5486E-5488E PRELIMINARY ULTRA HIGH SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH , Unit Load, 256 transceivers on bus · Driver short circuit current limit and thermal shutdown for , maintain high impedance in shutdown or when powered-off. FIGURE 1. TYPICAL APPLICATION CIRCUIT DE DE , -5488E ULTRA HIGH SPEED RS-485/RS-422 PROFIBUS TRANSCEIVERS WITH 1/8TH UNIT LOAD AND +/-15KV ESD-PROTECTION
Exar
Original
pin diagram of RS 485 IEC61000-4-2
Abstract: /phoenix/treeViewClick.do?UID=2744380 Drawings Dimensioned drawing Circuit diagram Functional , -pos., male connector, axial version with two cable entries, bus system: PROFIBUS DP up to 12 Mbps , 's declaration) General Nominal voltage UN 50 V Nominal current IN 100 mA Bus system PROFIBUS DP Signal PROFIBUS Insertion/withdrawal cycles > 200 SUBCON fixing screws 4-40 UNC , PSM-CABLE-PROFIB/FC PROFIBUS cable, Fast Connect type, up to 12 Mbps (02YSY (ST)CY 1x2x22 AWG) Connector Phoenix Contact
Original
C-8-2013

CLASS II LASER

Abstract: DME 40 indicator delivery Connection Diagram - Profibus C DC 18.30V blue 8) Reference voltage 32 V DC 9) A = , Diagram - Standard Tx+ TxRx+ RxQ1 - output Q2 - output QS - service output QP - plausibility output , Interfaces SSI Serial interface Profibus Measurement output rate SSI Serial interface Profibus , mm) 18.30 V DC5) 5 VPP6) Standard: 6 W 7) Profibus: 8 W 7) A, B PNP/NPN Active: VS ­ 2 V , ) Repeatability3) Resolution Supply voltage VS Ripple Power consumption7) Circuit protection 9) Outputs
-
Original
CLASS II LASER DME 40 indicator 3000-211S02 3000-211P02 rxq1
Abstract: Circuit diagram 6 VP 5 GND 1B 3 D(P) 1A 35,5 8 D(N) 16,6 220 390 , entry < 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide , ) General Nominal voltage UN 50 V Nominal current IN 100 mA Bus system PROFIBUS DP Signal PROFIBUS 26.08.2013   Page 1 / 6 D-SUB bus ,  2744652 PROFIBUS cable, Fast Connect type, up to 12 Mbps (02YSY (ST)CY 1x2x22 AWG)     Plug/Adapter D-SUB Phoenix Contact
Original
Abstract: Dimensioned drawing Circuit diagram 6 VP 5 GND 1B 3 D(P , entry < 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide , Nominal voltage UN 50 V Nominal current IN 100 mA Bus system PROFIBUS DP Signal PROFIBUS Insertion/withdrawal cycles > 200 28.10.2013   Page 1 / 6 https ,  2744652 PROFIBUS cable, Fast Connect type, up to 12 Mbps (02YSY (ST)CY 1x2x22 AWG)     Data plug D-SUB Phoenix Contact
Original
Abstract: ://   PROFIBUS bus coupler DP/V1, complete with I/O , PROFIBUS DP Type of connection D-SUB-9 female connector Transmission speed 9,6 kBit/s bis 12 , circuit supply UM 24 V DC -15% / +20% (in acc. with EN 61131-2) Power supply at UM max. 8 A DC , connector, two cable entries < 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be , -pos., male connector, cable entry < 90°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can Phoenix Contact
Original
AX-2009

IL PB BK DP

Abstract: profibus dp rs485 :// PROFIBUS bus coupler DP/V1, complete with I/O , PROFIBUS DP Connection method D-SUB-9 female connector Transmission speed 9,6 kBit/s bis 12 , Communications power UL 7.5 V DC ±5% Power supply at UL max. 2 A DC Main circuit supply UM 24 V DC , < 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch , system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin
Phoenix Contact
Original
IL PB BK DP profibus dp rs485 profibus rs485 9 pin 15 pin

IL PB BK DP

Abstract: IB PB BK :// PROFIBUS bus coupler DP/V1, complete with I/O connectors , for UL Supply for main circuit UM Power supply for UM Segment power supply voltage US Power supply for , D-SUB connector, 9-pos., male connector, two cable entries < 35°, bus system: PROFIBUS DP up to 12 Mbps , terminal blocks D-SUB connector, 9-pos., male connector, cable entry < 90°, bus system: PROFIBUS DP up to , /PG/ IDC D-SUB connector, 9-pos., male connector, cable entry < 90°, bus system: PROFIBUS DP up to
Phoenix Contact
Original
IB PB BK 2 pin terminal block connector 2708232 SUBCON-PLUS-PROFIB/90/PG/ SUBCON-PLUS-PROFIB/90/SC
Abstract: T-connector - SAC-M12T/2XM12 PB DP F - 1543553 Dimensioned drawing Circuit diagram 70 1 1 2 40,2 , Downloads are valid (http://download.phoenixcontact.com) Bus system T-connector, PROFIBUS PA, PROFIBUS , PROFIBUS PA Insertion/withdrawal cycles ≥ 100 Material Contact material CuZn Contact , Schematic diagram 4 3 Schematic diagram 3 1 4 5 5 2 Pin assignment M12 male Phoenix Contact
Original
EC002062 EC000830

profibus rs485 9 pin 15 pin

Abstract: Profibus circuit diagram :// PROFIBUS bus coupler, 16 inputs, 24 V DC, 16 outputs, 24 , /2008 Product description The complete station for PROFIBUS combines a PROFIBUS bus terminal, a , circuit UM Power supply for UM Segment power supply voltage US Power supply for US I/O supply voltage UANA , Spring-cage connection 2, 3-wire 16 Short circuit and overload protection Free running circuit 24 V DC -1 V , connector, cable entry < 90°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on
Phoenix Contact
Original