500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
SENSOREVAL Texas Instruments Eval Board Software For Hardware Monitors And Digital Temperature Sensors visit Texas Instruments
COMBOSENSOR Texas Instruments XTR117 XTR117 4-20mA Current Loop Transmitter visit Texas Instruments
GASSENSORNODE-REF Texas Instruments Wireless Universal Gas Sensing Platform Reference Solution visit Texas Instruments

PT100 SENSOR

Catalog Datasheet MFG & Type PDF Document Tags

PT100 4 wire temperature sensor

Abstract: PT100 connected diagram fibre-optic bus Connections Plug-in for PT100 sensor (2-wire, 4-wire) Data port II/O system , G Plug-in connector GND for PT100 sensor Input, PT100 sensor pick-off Input, PT100 sensor pick-off Constant-current source for PT100 sensor Beckhoff II/O System Page 9 of 10 Plug-in , : Example: Page 10 of 10 Description GND for PT100 sensor Input, PT100 sensor pick-off Input, PT100 sensor pick-off Constant-current source for PT100 sensor (1mA) GND for PT100 sensor Input, PT100
BECKHOFF
Original
PT100 4 wire temperature sensor PT100 connected diagram PT100 2 wire temperature sensor PT100 SENSOR PT100 3 wire temperature sensor PT100 bridge example D-33415
Abstract: Pt100 sensor Measuring range -200.850°C Ambient temperature -10.70°C Accuracy 0.3°C Battery , Temperature sensor Pt100, 2-wire (DIN/EN/IEC 60751) Battery: Energizer Lithium FR6 L91 AA , status Battery clip Terminals for Pt100 sensor + Control buttons Note: A Lithium battery , Battery operated digital thermometer 3A/DN38 hygienic, Pt100 sensor 1/6 DIN B Sensor, fast response, 3A , operated digital thermometer Clamp connection, Pt100 sensor 1/3 DIN B Sensor, fast response, clamp Baumer
Original
EN/2013-03-03

Siemens PT100 temperature sensor

Abstract: PT100 temperature sensor heating, ventilation and air conditioning systems ­ For use with controllers with Pt100 sensor inputs ­ , accuracy temperature measurement over a wide range with controllers equipped with a Pt100 sensor input , controllers which can process the measured value from a Pt100 sensor, especially controllers from the MULTIREG and INTEGRAL RS ranges. Technical design The Pt100 temperature sensor is fitted with a , relationship is linear. See data sheet 1714 for technical information on the Pt100 sensor element
-
Original
DIN43729 Siemens PT100 temperature sensor PT100 temperature sensor PT100 temperature sensor data sheet pt100 temperature sensor circuit diagram Siemens duct temperature sensor PT100 temperature sensor datasheet FK-TP/200 9N403 CA1N1778E IEC751 VDE3522 IEC529

Siemens PT100 temperature sensor

Abstract: PT100 temperature sensor Pt100 sensor inputs · In conjunction with MULTIREG and INTEGRAL RS. Use The FT-TP/. immersion , temperature measurement over a wide range with controllers equipped with a Pt100 sensor input, e.g , Technical design The Pt100 temperature sensor is fitted with a platinium measuring element with a , sheet 1714 for technical information on the Pt100 sensor element. The sensor FT-TP/. comprises a , 1 797 FT-TP/100 FT-TP/400 Immersion temperature sensor for HVAC systems Immersion
-
Original
PT100 B DIN 43729 PT100 temperature sensor water ISO-228 g1 ISO228 thread Siemens temperature sensor ISO228 9N402 CA1N1797E ISO228/1 9M427
Abstract: 100% RH Transmitter with Pt100 Sensor Wall Mount, 0 to 100% RH Transmitter Wall Mount, 0 to 100% RH Transmitter with Pt100 Sensor Flange for HX801, 100 mm (3.9") dia. Ordering Example: HX801T is a 220 mm (8.6") Duct Mount 0 to 100% RH Transmitter with Pt100 Sensor, $539. Hu-28 Omega Engineering , Basic Unit ß Monolithic IC Humidity Sensor ß 2 Wire, 4-20mA Transmitter ß Output Linearized With % RH ß Temperature Compensated Output ß Available With Pt100 RTD Output ß 40~200 mV Output Test Omega Engineering
Original
HX802 HX801/802 HX801/HX802 HX802T HX801-FLG

SEM203P

Abstract: current source pt100 The SEM203/P head mounted temperature transmitter connects to any standard pt100 resistance sensor , mA Precision resistance decade box to simulate PT100 sensor. Screw driver flat blade 3mm wide PT100 resistance tables Current meter (user trim) · Refer to figure 3, connect sensor or , period. · Set calibrator to the equivalent resistance of the pt100 sensor, at required trim point , allow 1 minute warm up period. · Set calibrator to the equivalent resistance of the pt100 sensor
RS Components
Original
XQ-126-RS JISC1604 SEM203P RS363-0238 current source pt100 PT100 standard IEC 60751 accuracy PT100 double

RTD PT100 3wire

Abstract: MCR-SL-PT100-LP-I range. The devices are supplied with the following default configuration: PT100 sensor, 0.100 , supplied with the following default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3 , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4wire technology ­ Can be mounted on , Universal PC programmable temperature measuring transducers convert temperature signals from PT100
Phoenix Contact
Original
RTD PT100 3wire pt100 temperature sensor circuit connection Pt100 3 wire pt100 temperature transducers MCR-SL-PT100 rtd pt100 4-20ma connections

pt100 temperature sensor circuit diagram

Abstract: adjustable zero span circuit and TAMB are used for measuring the temperature with a PT100 sensor according to DIN IEC 751. · , PT100 sensor 0.75 mA - 100 to + 400 °C dipswitch programmable from - 100 to + 375 °C in steps off 25 , Z E R O Type: TAMA & TAMB S P A N 12 11 14 35,0 mm PT100 TEMPERATURE , 0 - 1 V 0.2 - 1 V 0 - 10 V 2 - 10 V CONNECTION DIAGRAM PT100 3 WIRE PT100 3 WIRE - B1 B2 B3 + - B1 B2 B3 TAMA A1 PT100 2 WIRE + TAMB A2 SUPPLY
Thiim
Original
adjustable zero span circuit pt100 amplifier circuit diagram PT100 Amplifier pt100 circuit diagram transformer from 230V AC to 28v PT100 IEC 751 EN50081 EN50082 EN60255 EN60688

PT100 application note

Abstract: pt100 sensors default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. 5 , . Configuration The devices are supplied with the following default configuration: PT100 sensor, 0.100 , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4-wire technology ­ For installation , transducers convert temperature signals from PT100 resistance thermometers to analog 4.20 mA signals. On
Phoenix Contact
Original
PT100 application note pt100 sensors PT100 IEC B PT100 temperature sensor class B pt100 thermometer PT100 temperature transducer 3 wire MCR-FL-HT-PT100-I

MCR-SL-PT100-LP-I

Abstract: PT100 application note configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquar ters , default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. To , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4wire technology ­ Can be mounted on , temperature signals from PT100 resistance thermometers to analog 4.20 mA signals. On the output side the
Phoenix Contact
Original
application note pt100 mcr pt100 namur NE 43 pt100 sensor 2wire

PT100 IEC 751

Abstract: en60751 . 2.0 SPECIFICATION @ 24 ºC 2.1 RTD INPUT (Pt100) Sensor Range Minimum Span*¹ Linearisation , connection to provide a (4 to 20) mA current loop output. The Pt100 sensor shown would normally take the , INPUT SENSOR RANGES Thermocouple Type TC Type K TC Type J TC Type T TC Type R TC Type S TC Type , quick selector or via PC) 1000 m Sensor type: Burnout: ºC/ºF: Output: PC: Hi/Lo: Filter: Tag: User , screened cable is used for the input signal wires for cable runs greater than one metre. For Pt100 inputs
Status Instruments
Original
BS1904 en60751 slide linear potentiometer pt100 PT100 Thermocouple Amplifier transducer 61326 pt100 datasheet 0.05 SEM215 EN60751

MCR-SL-HT-PT100-I

Abstract: PT100 SENSOR configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Dimensional drawing , Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 5. Installation in the Sensor Connection Head , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4-wire technology ­ For installation , convert temperature signals from PT100 resistance thermometers to analog 4.20 mA signals. On the output
Phoenix Contact
Original
rtd pt100 sensor PT100 2 wire temperature sensor -200 to 650

EN60079-14

Abstract: sem210x loop output. The Pt100 sensor shown would normally take the form of a probe assembly with a three wire , in-head temperature transmitter that accepts any commonly used temperature sensor, slidewire transducer , Accuracy*² Input Impedance Thermal Drift Zero Span 2.0 SPECIFICATION @ 20 ºC 2.1 RTD INPUT (Pt100) Sensor Range Minimum Span*¹ Linearisation Basic Measurement Accuracy*² Thermal Drift Zero Span , , 4th order polynomial 5% 0.1 % FRI 0.01 %/ºC 2.5 OUTPUT 2.2 THERMOCOUPLE INPUT SENSOR RANGES
Status Instruments
Original
EN60079-14 sem210x Universal GAS SENSOR MARKING x328 pt100 ANSI EN60584 SEM210

"Humidity Sensor"

Abstract: sensor PT100 humidity sensor + Platinum heating element / Pt100 sensor W= 3,81 x L= 7,7 x D= 0,4 mm 0 . 100 % RH , P14 Thermo Capacitive Humidity Sensor Heated Product The P14 Thermo was designed especially for , capacitive humidity sensor, based upon the famous P14 sensor, together with a heating element which is also , sensor array clearly to best in class. Advantages · · · · · · · · Application in dew point , comfortably even under dewing conditions 1 chip solution = sensor + heating element / Pt100-sensor
Innovative Sensor Technology
Original
sensor PT100 dew point sensor pt100 datasheet temperature sensor pt100 humidity sensor

ni500 DIN 43760

Abstract: PT500 IEC 751 temperature range. The devices are supplied with the following default configuration: PT100 sensor, 0.100 , : internal (Pt100) or external (0.80°C [32.176ºF]) · Cold junction accuracy: ±1 K Voltage sensor (mV , 5. Configuration The devices are supplied with the following default configuration: PT100 sensor , . Failure information in the event of sensor breaks or sensor short circuit can be set according to NE 43 , Measuring Span Pt100 Pt500 Pt1000 according to IEC 751 Resistance thermometer (RTD) -200 to
Phoenix Contact
Original
ni500 DIN 43760 PT500 IEC 751 Resistance characteristic Ni1000 Resistance characteristic Pt1000 pt100 4-20 ma ni1000 DIN 43760

ZPH1-5216

Abstract: el 7406 . 20 mA output Temperature Media Secondary coil Pt100 sensor www.baumer.com Data sheet , compensation of the conductivity signal, which is very temperature dependent. The Pt100 sensor signal is also , " AFI5 split version with remote sensor Â"Â" Separate 4.20 mA output for conductivity , 14 selectable ranges Temperature (sensor incl. transmitter @ 25°C ambient) Cond./conc , Left side ≤ 0.05%/K 1) AFI5: ≤ 0.05%/K + 0.005%/K pr. m sensor cable IEC 60068.2.6 - test
Baumer
Original
ZPH1-5216 el 7406 EN/2015-03-17

PT100 standard IEC 60751 accuracy

Abstract: PT100 IEC 751 Murrelektronik temperature converter module works in conjunction with a temperature sensor PT100 (IEC 751/EN 60751) and converts the output from the sensor into a standard signal format of (0.10 V, 0.20 mA or 4.20 mA). The MTW module supplies a constant current to the PT100 resistor across, which develops a , between the MTW and the PT100 sensor to be covered, i.e. , data Supply voltage range Supply current Cable resistance (without PT100) Output signals
-
Original
PT100 resistor mtw 12 PT100 bridge signal converter pt100 murrelektronik PT-100 temperature sensor

sensor TCJ

Abstract: PT100 connected diagram connection of the 3rd wire (Pt100 sensor) in "AL" folder it will appear the label "Pt3". For few seconds , / / / / / / / / / / / / / / / VALUE* U.M. (1) PARAMETER VISIBLE ONLY INTcJ/TcK MODELS. Pt100 Model works only with Pt100 sensor (3 wires) while TcJ and TcK Models work also with Pt100 sensor selectable by this parameter , with the protection of a delayed 250 mA fuse. Probe cable (Pt100 model), power supply cables and the TTL serial cables should be distant from power cables. (Pt100 model) Probe can be extended using a
Invensys Climate Controls
Original
sensor TCJ pt100 TRANSFER FUNCTION PT100 3 wire connected diagram LOD voltage regulator 12v 230v 12V power supply ic PT100 WIRING standard 100-TC 9IS22093 100/T

PT100 thermistor

Abstract: pt100 temperature sensor schematic accuracy we recommend a 4 wire class A Pt100 sensor. 19mm (0.75") Digit Height Simple Connection LED , DTM 910 LCD Type Pt100 Temperature Indicator The DTM 910 will give an accurate direct temperature reading in either °C or °F from a 2, 3 or 4 wire Pt100 thermistor*. Simple single step calibration , to correspond with a known accurate temperature. Stock Number Standard Meter Sensor DTM , As the Pt100 is a passive device, no voltages should be applied to the input terminals. DIMENSIONS
-
Original
PT100 thermistor pt100 temperature sensor schematic pt100 schematic PT100 thermistor sensor pt100 temperature schematic PT100 3 wire thermistor

PT100 IEC 751

Abstract: MCR-SL-PT100-I-DC-24 Temperature Measuring Transducer for PT100 MCR-SL-PT100-.-DC-24 1. Description MCR-SL-PT100 temperature measuring transducers convert the measured values of the PT100 sensor (IEC rigid751/EN 60751) into electrically standardized analog signals. The sensor is supplied from the module with a low , increase the process safety, the modules are equipped with 3-way isolation. 2-, 3-, and 4-wire PT100 , Temperature Measuring Transducer for PT100 ­ MCR-SL-PT100-.-DC-24 2. Technical Data OUT 1 2 D
Phoenix Contact
Original
MCR-SL-PT100-I-DC-24 phoenix DIP switch settings MCR-SL-PT100-U-DC-24 MCR-SL-PT100 DC 24 pt 100 sensor PT100 type B iec 60751
Showing first 20 results.