500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
074421-000 TE Connectivity Ltd THERMOCOUPLE CABLE visit Digikey Buy
CTC-0062-20-9/5-9 TE Connectivity Ltd THERMOCOUPLE CABLE visit Digikey Buy
A115 Test Products Inc THERMOCOUPLE ADAPTER visit Digikey Buy
515239-000 TE Connectivity Ltd THERMOCOUPLE CABLE visit Digikey Buy
471270-000 TE Connectivity Ltd THERMOCOUPLE CABLE visit Digikey Buy
CTC-0039-22-9/5-93CS1963 TE Connectivity Ltd THERMOCOUPLE CABLE visit Digikey Buy

PL II thermocouple

Catalog Datasheet MFG & Type PDF Document Tags

900-TC16

Abstract: 900-TC8RGTZ25 touch assignment of Auto/Manual, Run/Stop, etc) Yes No Thermocouple Types: Added W and PL II Yes Yes New Series B Feature/Functionality Thermocouple Accuracy: Improved from +/-0.5% of PV , sensor Thermocouple JPt100 K J T E L U N R S B PL II W 10 , Line Voltage R, S, B, W, PL II Thermocouple Inputs: ±1% of PV or ±10°C, whichever is great, ±1 , current inputs · The combination of thermocouple and platinum RTD controller types into one Global
Rockwell Automation
Original

manual omron E5CN-r2MT-500

Abstract: manual omron E5CN-Q2MT-500 : 4 VA/2 W) Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II , T E L U N R S B W PL II 10 to 70° C 60 to 120 °C 115 to , : JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II , , W, PL II): Terminal block models (E5CN): (±1% of PV or ±10° C, whichever is greater) ±1 digit max , is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV or ±2° C
-
Original

rosemount 1144

Abstract: rosemount pt 100 rtd case of error (NE 43) Approvals for explosion protection ­ Intrinsically safe II 2 (1) G EEx [ia] ib IIC T6, mount in zone 1 II 3 G EEx n A II T6, mount in zone 2 ­ Pressure proof II 2 G EEx d IIC , disconnectible Thermocouple measurement > 5 k Voltage measurement > 5 k Input filter 50/60 Hz Internal , Measuring range Min. measuring span Sensor IEC 584 1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T
ABB Automation
Original

abb ts202

Abstract: SENSORS TEMPERATURE Pt-100-DIN 43760 ­ Intrinsically safe II 2 G EEx [ia] ib IIC T6, mount in zone 1 II 3 G EEx n A II T6, mount in zone 2 ­ Pressure-proof II 2 G EEx d IIC T6, mount in zone 1 Input functionality (absolute , Input element Standard Measuring range Min. measuring span Sensor IEC 584-1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N 250.+1820 °C ­250.+1000 °C ­210.+1200
ABB Automation
Original

th202

Abstract: ABB Hart Temperature Transmitter TH202 explosion protection ­ Intrinsically safe II 2 (1) G EEx [ia] ib IIC T6, mount in zone 1 II 3 G EEx n A II T6, mount in zone 2 ­ Pressure-proof II 2 G EEx d IIC T6, mount in zone 1 Input functionality , disconnectible Thermocouple measurement > 5 k Voltage measurement > 5 k Input filter 50/60 Hz Internal , Measuring range Min. measuring span Sensor IEC 584-1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T
ABB Automation
Original

omron e5ex manual

Abstract: e5ex : K, J, T, E, L, U, N, R, S, B, W, PL II (-199.9 to 2,300°C) · Platinum RTD: Pt100, JPt100 (-199.9 to , Thermocouples types: K, J, T, E, L, U, N, R, S, B, W, PL II (-199.9 to 2,300°C) · Platinum RTD: Pt100, JPt100 , Ranges Type K Thermocouple: 0 to 399°C · · · · Supply Voltage 100/110 or 200/220VAC, 50 , . Type K Thermocouple: 0 to 1,200°C (7 scales) Type J Thermocouple: 0 to 400°C (3 scales) JPt100: -50 , Thermocouple: 0 to 999°C (6 ranges) Type J Thermocouple: 0 to 500°C (5 ranges) JPt100, Pt100: -50 to 400°C (9
OMRON
Original
omron e5ex manual e5ex OMRON E5CX temperature controller omron e5cw manual E5CW omron e5ex IP66/NEMA4 RS232/RS422/RS485 C200HX/HG/HE 222675-U X203-E1-1-SN 0897-1B

pt100 atex

Abstract: AGLF Sensor wire break monitoring in accordance with NAMUR Thermocouple measurement > 5 k Voltage , dependent on the Ex supply unit Resistance 10/11-8.69 EN Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N Thermocouple type C Thermocouple type D Thermocouple type L Thermocouple type U Resistance thermometer Pt100 Resistance thermometer Pt1000 Resistance thermometer Ni100
ABB Automation
Original
NGV220-NO pt100 atex AGLF ABB Pt100 3 wire NGV220-EX agsfd Thermocouple Type K TF202/TF202-E NGV220-E TF202

E5GN-Q1TC manual

Abstract: IEC 584-1 JPt100 K J T Thermocouple PL II Infrared temperature sensor N R S B W 2300 1800 1700 1700 Analog , FS ±1 digit max. Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater , , T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared , E988-1990 JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to , accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ± 1 digit max. *2. Ambient
OMRON
Original
E5GN-Q1TC manual IEC 584-1 E5GNR103T-FLK omron modbus

E5CN-R2T

Abstract: manual omron E5CN-Q2MT-500 ) Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II , temperature sensor Thermocouple JPt100 K J T E L U N R S B W PL II , 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive , , S, B, W, PL II): Terminal block models (E5CN): (±1% of PV or ±10°C, whichever is greater) ±1 digit , ±3°C, whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV
OMRON
Original
E5CN-R2T manual omron E5CN-Q2MT-500 PV 100 USB H156 manual omron E5CN-Q2MTd-500 E53-CN

manual omron E5CN-Q2MT-500

Abstract: E5CN-R2T input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II , K J T E L U N R S B W PL II 10 to 70°C 60 to 120 °C , 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from , , S, B, W, PL II): Terminal block models (E5CN): (±1% of PV or ±10°C, whichever is greater) ±1 digit , ±3°C, whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV
OMRON
Original
E5CN-R2T manual E5CN-R2Td omron manual omron E5CN-R2MT-500 E5CN-Q2MT-500 Omron omron e5cnh pt100 jis

H156

Abstract: H158 temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer , : ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Thermocouple input (R, S, B, W, PL II): (±1% , T E L U N R S B W PL II 10 to 70°C 60 to 120 °C 115 to 165 , , IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard , accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ± 1 digit max. *2. Ambient
OMRON
Original
H158 electrical cooling

RELAY OMRON E5EN

Abstract: E5AN-C3MT-500-N Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 , of voltage *2 Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater , S B W PL II 10 to 70°C 60 to 120 °C 115 to 165 °C 140 to 260 °C , greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is , Thermocouple input: ±0.3% of PV (previous models: ±0.5%) Pt input: ±0.2% of PV (previous models: ±0.5%
OMRON
Original
RELAY OMRON E5EN E5AN-C3MT-500-N E58-CIFQ1 E5AN-R3HMT-500 EN01 E5EN-R3MT-500-N

RELAY OMRON E5EN

Abstract: E5AN-C3MT-500-N Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 , sensor Thermocouple JPt100 K J T E L U N R S B W PL II 10 , Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other , 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive , accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ±1 digit max. *2. Ambient
OMRON
Original
E5EN-C3MT-500-N E5EN-R3HMT-500-N E5EN-R3HHMT-500-N E5EN E5AN-Q3ML-500-N E5EN-R3MT-500

manual omron E5CN-H

Abstract: E5CN-h , B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Current input: 4 to 20 mA or 0 to , R S B W PL II 4 to 0 to 20 mA 20 mA 1 to 5V 0 to 0 to 5 V 10 V 2300.0 , 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from , ±3°C, whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV , thermocouple/Pt/analog (current/voltage) inputs. Indication Accuracy · Thermocouple/Pt input: ±0.1% of PV ·
-
Original
Y92F-45 manual omron E5CN-H E5CN-h e53 modbus E54-CT1 E53-cn03n2 E5CN-HC2M-500 RS-485 RS-232C E54-CT3

E5EN-HAA3BFM-500

Abstract: RELAY OMRON E5EN following can be selected. Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance , Thermocouple JPt100 K J T E Analog input L U N R S B W PL II 4 to , , S, B, W, PL II): (±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple input , 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from , is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3% of PV or ±2°C
OMRON
Original
E5EN-HAA3BFM-500 omron E53-C3N omron e5en-h E5EN-HAA2HBMD-500 E5EN-HPRR2BFM-500 rtu en01 modbus programming

E5AN-HTAA2HBM-500

Abstract: E53-C3N be selected. Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer , JPt100 K J T Thermocouple E L U N R S B 1800.0 Analog input W 2300.0 PL II 4 to 20 m A 0 , : ±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max. Thermocouple input (R, S, B, W, PL II , E988-1990 JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According , indication accuracy of PL II thermocouples is ±0.3% of PV or ±2°C, whichever is greater, ±1 digit max. *2
-
Original
E5AN-HTAA2HBM-500 E53-C3N E53-V34N E53-RN omron temperature controller e5cn

E58-CIFQ1

Abstract: E5GNQ1 Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 , ) Input Type Name Platinum resistance thermometer Pt100 JPt100 K J T Thermocouple PL II Infrared , max. CT input: ±5% FS ±1 digit max. Thermocouple input (R, S, B, W, PL II): (±1% of PV or ±10°C , Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF , , whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV or ±2°C
OMRON
Original
E5GNQ1 e58c

omron e5cnh

Abstract: manual omron E5CN-H Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 , Thermocouple JPt100 K J T E L U N R S B W PL II 4 to 0 to 20 mA 20 mA , , IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard , accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ±1 digit max. *2. Ambient , Controller (48 x 48 mm). · High-speed sampling cycle of 60 ms. · High Accuracy Thermocouple/Pt input
OMRON
Original
CT1 relay Ct215 H157 H159 omron e5cn E5CN-HV2M-500
Abstract: .) Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II , ±1 digit max. CT input: ±5% FS ±1 digit max. Thermocouple input (R, S, B, W, PL II): (±1% of PV or  , K J T E L U N R S B W PL II 10 to 70°C 60 to 120 °C , -1990 JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel , ±3°C, whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV or  OMRON
Original

E5CN-HTQ2M-500

Abstract: E5CN-HTR2M-500 can be selected (i.e., fully universal input). Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II , JPt100 K J T Thermocouple E L U N R S B 1800.0 1700.01700.0 Analog input W PL II 2300.0 4 to 0 , E988-1990 JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According , ±3°C, whichever is greater, ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3 of PV , Accuracy 48 × 48 mm E5CN-HT Thermocouple/Pt input: ±0.1% of PV Analog input: ±0.1% FS · Universal inputs on
OMRON
Original
E5CN-HTQ2M-500 E5CN-HTR2M-500 omron temperature controller E5CN-HTV2M-500 E5CN-HTQ2MD-500 E5CN-HTC2M-500
Showing first 20 results.