500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
TIPD109 Texas Instruments Simple Thermocouple Measurement Solution Reference Design, <1°C Accurate visit Texas Instruments
HSP50214BVC Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
HSP50214BVI Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
HSP50214BVCZ Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
ISL5571A/B-EVAL1 Intersil Corporation Access High Voltage Switch; Temperature Range: - visit Intersil
HSP50214BVIZ Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy

Omega k type thermocouple range

Catalog Datasheet MFG & Type PDF Document Tags

TAC80B

Abstract: TAC80 °F 0.000 mV 14.862 mV Figure 1-2. Potentiometer Locations K TYPE THERMOCOUPLE LEADS COM , TRP REFERENCE PROBES K TYPE THERMOCOUPLE CONNECTOR Figure 1-3. Calibration Set-up TRC III , ® TAC80B-J, K, T TAC80B-K Thermocouple-to-Analog Converter Thermocouple to Analog , ® TAC80B-J, K, T Thermocouple to Analog Converter can turn any chart recorder, analog or digital voltmeter , amplifier and linearizer which provides a precision 1mV/°C or °F signal for type J, K or T thermocouples
Newport Electronics
Original
TAC80B TAC80 M1710/0394 TAC80B-AC

HHM290

Abstract: Emissivity: 1. Set the Function switch to T/C. 2. Plug in a K type surface thermocouple probe to the meter , multimeter can accept up to two K type thermocouple inputs. 3. Plug in the thermocouple probe(s) to the , Rubber Boot, a pair of test leads, 6 AA size Batteries, One Spare fuse, Type K Beaded wire thermocouple , Input (K type T/C) Battery Replacement Power is supplied by 6 pcs 1.5V (AA size) battery (UM-3 R6). , ") Temperature Scale: Celsius or Fahrenheit user-selectable Measurement Range: Thermocouple Range K-TYPE
Newport Electronics
Original
HHM290 D-75392 1-800-TC-OMEGA EN61010-1
Abstract: chart below Thermocouple Accuracy Chart (°C) Temperature Range Point Thermocouple Type J K T E , to 95% relative humidity OM-SP1700 SERIES THERMOCOUPLE LOGGER Input Type: thermocouple, type J, K , readily-available thermocouple probes in J, K, T, E, R and S types. Each logger is calibrated during manufacture , accessory current probes Resolution: see thermocouple resolution chart below Input Impedance: >500 K , Repeatability: 0.5% over 0 to 75% RH Thermocouple Resolution Chart (°C) Thermocouple Type Resolution Omega Engineering
Original
OM-SP4000 OM-SP1700-200 OM-SP1700-300 OM-SP1700-500 OM-SP2000 OM-SP4000-1CW
Abstract: thermocouple wire (type K), protective rubber holster (HH64-H), and operatorâ'™s manual L FREE! All temperature models include a free 36" type K beaded wire thermocouple with subminiature connector and wire , thermocouple wire (type K), protective rubber holster (HH64-H), and operatorâ'™s manual. Ordering Example , The OMEGA® HH64 microprocessorbased thermometer accepts four different thermocouple type probes (J , Connection: Subminiature OMEGA type SMP Operating Mode: Display hold, max/min function Resolution: 0.1 Omega Engineering
Original
88012K SC-GG-K-30-36

SUPER MCJ

Abstract: DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K , Temperature Range: Type J: -100 to +750°C (-148 to +1382°F) Type K: -100 to +1250°C (-148 to +2282°F) Type T: -100 to +350°C (-148 to +662°F) Accuracy @ 75°F ambient temperature across the range: Type J: ± 1.4°C (± 2.5°F) Type K: ± 3°C (± 5°F) Type T: ± 2°C (± 3°F) Input Connection , Thermocouple Input Super MCJ Analog Output, 1 mV per degree (SMP or OST Connector
Newport Electronics
Original
SUPER MCJ M-2813
Abstract: Type J Thermocouple Input, Range: -105 to 750°C (-157 to 1382°F) Type K Thermocouple Input, Range: -20 to 1200°C (-40 to 2192°F) Type T Thermocouple Input, Range: -86 to 350°C (-123 to 662 , -386-TC, Thermocouple-to-analog converter in °C, type T, $131. K-19 Omega Engineering , OMEGA WHITE BOX® PRODUCT Specifications Ranges: J: -105 to 750°C (-157 to 1382°F) K: -20 to , /°C Input Connection: Miniature thermocouple connector type, SMP Output Connection: standard Omega Engineering
Original
TAC-386 MN1604 TAC-386-J TAC-386-K TAC-386-T TAC-386-TC
Abstract: Pressure: 150% of rated range, no damage ELECTRICAL CHARACTERISTICS Sensor Type: Bonded strain gage, 4 , 125 = $995. 10 FT. (3m) LONG THERMOCOUPLE CABLE OMEGA MATING CONNECTOR WK6-21C-1/4 , CX340-10K 3.05 m (10') TYPE K Armored Cable-Mating Connector/Spade Lugs CX340A-10 3.05 m (10') NONE CX340A-10J 3.05 m (10') TYPE J CX340A-10K 3.05 m (10') TYPE K WK6-21C-1/4 Mating Connector , . (Also available to be Dynisco compatible) Insulation Resistance: 100 Mâ"¦ @ 50 Vdc Thermocouple Omega Engineering
Original
C-276 WK6-325 WK6-21C-1 PX380- PX381- PX390-
Abstract: assembly can be quickly assembled for fast delivery. Popular Type K Thermocouple Elements Shown Above , length required. Temperature limitation is by type of thermocouple material selected. A-18 Omega , °C (2200°F) ß Available In Type K, E and J Calibrations OMEGA® Nextel Ceramic Insulated Thermocouples , . Consult sales for additional information. Type J Thermocouple Element Shown in Thermowell , lengths available) AWG Wire Size Type K Price Price Add'I Type E Price Price Add'l Type J Omega Engineering
Original
1/2-260S XC-14-K-12 XC-14-E-12 XC-14-J-12 XC-20-K-12 XC-20-E-12
Abstract: K type Thermocouple (HHM63C/HHM63F/HHM63K) ß DATA HOLD Function ß Models with 0.1°, 1 , battery Extra set of test leads 102 Comes with beaded type K thermocouple HHM64 Stick Type , , set of safety test leads, type K beaded wire thermocouple (temperature models only) and complete , measurement) HH63KF-MV/ HH63KC-MV Temperature Transducer Comes with type K thermocouple, Green LED , protection 24 Vac/Vdc Accuracy: up to ±0.3% °C/°F Switchable Comes with beaded type K thermocouple Omega Engineering
Original
HHM60 HHM63 HHM60-TL MN2400 HHM63C/ HHM63F

Thermocouple Type L

Abstract: °C to 1000°C Scaling charge *Insert J,K,T,E,R or S for thermocouple type. Each unit supplied with , transmitters feature dip switch selection of input type and range. The following models are available: TX901 , -2 251 TX-SCALED 45 J, K, T, E, R, S thermocouple input, non-isolated J, K, T, E, R, S thermocouple input, isolated 100 â"¦ Pt RTD input (a = 0.00385), non-isolated Range: -150°C to 500°C (-238 , input simulation required to scale output for a particular range. To order unit scaled by OMEGA specify
Omega Engineering
Original
Thermocouple Type L TX900 TX903 TX904 TX905 TX902 PR-12
Abstract: Standard Style 1 2 3 Thermocouple Type Length mm (inches) K E T K E T J K E T , of Error" grade thermocouple materials in "K", "E" and "T" calibrations and yield accurate , error thermocouple wire. It should be used where extremely fast response is not essential. OMEGA , application instruction sheet accompanies each packaged Cement-On type thermocouples. STYLE 2 OMEGA , ") Foil and 0.25 mm (0.010") Diameter Thermocouple Wire ß Very Low Thermal Inertia ß Four Omega Engineering
Original
OB-101 OB-200
Abstract: / HH63KC-MV Temperature Transducer Comes with type K thermocouple, Green LED Power-on , Annunciator , Accuracy: up to ±0.3% °C/°F Switchable Comes with beaded type K thermocouple 0.1/1.0° Resolution , , four AAA alkaline batteries, set of safety test leads, type K beaded wire thermocouple (temperature , , $80. Stick Type Temperature Transducer and Thermometer Stick Type Temperature All Thermocouple Probes Sold Separately See OMEGA's Complete Line of Thermocouple Probes in Section A. Transducerâ Omega Engineering
Original
HH63KF-MV HH63K
Abstract: K type Thermocouple (HHM63C/HHM63F/HHM63K) ß DATA HOLD Function ß Models with 0.1°, 1 , $86 HHM63C/ HHM63F $102 Comes with beaded type K thermocouple HHM63C/HHM63F Multimeter , leads, type K beaded wire thermocouple (temperature models only) and complete operator's manual. L , models include a free 36" type K beaded wire thermocouple with subminiature connector and wire spool , 24 Vac/Vdc Accuracy: up to ±0.3% °C/°F Switchable Comes with beaded type K thermocouple 0.1 Omega Engineering
Original
Abstract: Excitation: 1 mA Thermocouple Input Types and Ranges Type Input Range Low, °F (°C) K J T E R , manual. *Specify thermocouple type J,K,T,E,R,S, or B. Ordering Example: DRA-TCI-2-J DIN rail 2-wire J , low ripple current. Model DRA-TCI-2 is available for thermocouple types J, K, T, E, R, S or B and , g Model DRA-TCI-2 Input: Thermocouple types J, K, T, E,R,S,B (see thermocouple input types and , change (±3°C for types R and S) Accuracy (Including Linearity): ±0.08% of span for type K,  Omega Engineering
Original
DRN-PS-1000
Abstract: Intervals from 1000°F to 2440°F (538°C to 1338°C) Limits of Error for Type K & N Thermocouple Wire T/C Temperature Range Limit of Error* Type °C (°F) Standard Special K N 0 to 1250 (32 to , ELIMINATES HIGH TEMPERATURE DRIFT A il bl i T K T N C Typical OMEGACLAD® XL Type K , SIZES IN STOCK FOR FAST DELIVERY! [*] Insert Wire Calibration TYPE K or TYPE Sheath , [*] Insert "K" for Type K Cable or "N" for Type N Cable, [*] Insert Length in Feet for Imperial Models or in Omega Engineering
Original
XL-K-MO-125-250
Abstract: ; thermocouples attach directly to on-board screw-terminals Thermocouple Types: J, K, S, T, E, B, R, N Type Range (°C) J K T E N28 N14 S R B -200 to 760 -200 to 1260 -200 to 400 -270 to 1000 , On-Board ColdJunction and Offset-Drift Compensation ß Supports type J, K, S, T, E, B, R and N , maximize A/D resolution based on the type of thermocouple attached to the channel being measured , OMB-DBK19 MADE IN USA 14-Channel High-Accuracy Thermocouple Expansion Card for Use with Omega Engineering
Original
OMB-CA-37- OMB-CA-131- H-114
Abstract: Section A CL20 Series Temperature Measurement and Calibration Range Input Type K J T E N B R , Input Devices Beaded Wire Probe Belt Clip TA4F RTD Adaptor Type J, K, T, E Thermocouple , adaptor. CL23A does not include type E thermocouple, adaptor or cable. Ordering Examples: CL24 J/K/T/E , limits. There is also a manual ramp function. No matter what thermocouple type is used, one of these , ', retractable, expands to 10', SMP to spade lug * Insert type (J, K, T, E, R/S, N or mV) * Insert type (J, K Omega Engineering
Original
Abstract: -0-800C transmitter calibrated for type K thermocouple with range of 0 to 800°C, TX-SCALED, scaling charge, $109 + , ) TX250 Thermocouple Input Specifications Input: TX251: thermocouple type K, T, J TX252: thermocouple type E TX253: thermocouple type R, S Calibration: Two â'Zeroâ' DIP switches, three â'Spanâ' DIP , Thermocouple Heads Shown in Section B. $109 109 109 109 45 Transmitter for J, K, T type , by OMEGA order as follows: TX251-(1)-(2)-(3) where (1) is input type, (2) is low end of range, (3 Omega Engineering
Original
TX254 TX251-K-0-800C

alpha POTENTIOMETERS

Abstract: ) Accuracy (Including Linearity): ±0.08% of span for type K, ±0.1% to ±0.2% for other thermocouple , resistance Sensor Excitation: 1 mA Thermocouple Input Types and Ranges Type Input Range Low °F (°C) Input Range High °F (°C) Min Span °F (°C) K J T E R S B 32 (0) 32 (0) 32 (0) 32 , thermocouple type J,K,T,E,R,S, or B. Ordering Example: DRA-TCI-2D-J DIN rail 2-wire J thermocouple input , Back-Lit Loop Powered Display Model DRA-TCI-2D is available for thermocouple types J, K, T, E, R, S
Omega Engineering
Original
alpha POTENTIOMETERS
Abstract: (0.065"). The HYP-0, HYP-1 and HYP-2 have type T (CopperConstantan) thermocouple elements, while the , result in an extremely small type T (CopperConstantan) thermocouple being implanted in a 33 gage, 25 mm , ® coated, 36 AWG leads with an SMP type subminiature connector. Thermocouple Probe Model HYP-1 OMEGA , range is cryogenic to 200°C (400°F). This is a type â'Tâ' 38 (1.5) 22 (0.87) 22 (0.87 , Hypodermic and Mini Hypodermic Probes Thermocouple and RTD Elements All probes were designed Omega Engineering
Original
HYP3-16-11 HYP4-16-11 2-100-EU-48-RP HYP1-30-1 2-T-G-60-SMP-M
Showing first 20 results.