500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LM9044VX/NOPB Texas Instruments Lambda Sensor Interface Amplifier 20-PLCC -40 to 125 visit Texas Instruments
LM9044V/NOPB Texas Instruments Lambda Sensor Interface Amplifier 20-PLCC -40 to 125 visit Texas Instruments Buy

Lambda LQD-421

Catalog Datasheet MFG & Type PDF Document Tags

LQ410

Abstract: Lambda LQD-421 PART III â'" LAB, TEST EQUIPMENT AND SYSTEM POWER SUPPLIES Lambda LQ series PURE DC Regulation: 0.005% Ripple: 150 ¡jN Temp. Coeff: 0.005%/° C Made possible through use of Lambda's monolithic, multi-function voltage regulator with built-in, on-chip temperature regulation. Only Lambda has , voltmeter and ammeter). Controls DC Output Controls Coarse/fine (LQD-421, LQ-410, LQ-411, LQ-530, LQ , Parallel) MODEL (Per Output/Outputs in Serta«) 30"C 40PC 50°C 60° C PRICE LQD-421 0-±20/0-40 1.7
-
OCR Scan
LQ-533 LQ-534 LQ410 Lambda LQD-421 LQ-522-LQ-524 lambda lq-532 LQ-521 LQ-415 LQD-425 LQD-420 LQ-520

LAMBDA LQD-425

Abstract: LQ-522-LQ-524 are backed with Lambda's 5 year guarantee. This ensures the product will operate to published , (IQD-421, LQ-410, LQ-411, LQ-530, LQ-531, LQ-520, LQ-521, LPT) or multiturn (LQD-422 through LQD , Lambda LPS Series is designed for use with today's modern switching power supplies which accept either AC , building blocks in a user customized UPS Power System. A standard Lambda UPS system consists of an LPS unit, a Lambda power supply, and a battery to provide loss-of-power protection. The Lambda UPS Power
-
OCR Scan
LPT-7202-FM LAMBDA LQD-425 LQ425 lq 425 IQ-412 500VDC 132VAC 242VAC FRL-24-005

Lambda LQD-421

Abstract: LQD 421 test use. H The LQ and LPT Series are backed with Lambda's 5 year guarantee. This ensures the product , (LQD-421, LQ-410, LQ-411, LQ-530, LQ-531, LQ-520, LQ-521, LPT) or multiturn (LQD-422 through LQD , QTY. 25 MODEL 0- ±20/0-40 1.7/3.4 1.5/3.0 1.3/2.6 0.90/1.8 129 190 $1377 $1312 $1259 LQD-421 0- +40
-
OCR Scan
LQD422 LQD423 LQD424 LQD 421 LQD-423 LH-OV-5 LQD421 LQD425

Lambda diode

Abstract: dual diode to3 common anode \ 10 20 40 60 80 100 120 140 REVERSE VOLTAGE (VOLTS) 421 VEECO/LAMBDA SEMICOND ODOlDlfl a 9447636 VEECO/LAMBDA SEMICOND T 02E 01018 D â'" PMR 35K, 36K SERIES ' '-r-sh-tn" ' DEVICE OUTLINE Bottom View , VEECO/LAMBDA SEMICOND DÌ ÃÃJ^MMTbBb DODlDlt. =J J>447636 VEECO/LAMBDA SEMICOND A LAMBDA RECTIFIERS 02E 01016 p PMR 35K, 36K SERIES 30 AMP HALF BRIDGE DUAL RECTIFIERS FEATURES â'¢ Maximum , . D001D17 â¡ 9447636 VEECO/LAMBDA SEMICOND PMR 35K, 36K SERIES 02E 01017 D "t-äs-oT"" ELECTRICAL
-
OCR Scan
Lambda diode dual diode to3 common anode veeco lambda pmr 36K050 36K100 36K200 35K050 35K100 35K200

Lambda VEGA 650

Abstract: klaasing Lambda to validate configuration and issue a part number Vega Datasheet 09 Mar 04 Rev.2 80.50 , Fax: +61 88 2764024 JAPAN DENSEI LAMBDA KK, 1-11-15 Higashigotanda, Shinagawa-Ku, Tokyo 141, Japan Tel: +81 3 3447 4411 Fax: +81 3 3447 7784 AUSTRIA LAMBDA ELECTRONIC GmbH Aredstraße 22, A-2544 Leobersdorf, Austria Tel: +43 2 256 65584 Fax: +43 2 256 64512 KOREA DENSEI LAMBDA KK, 6F Sungok Bldg , : +32 3 6649901 CANADA LAMBDA ELECTRONICS (CANADA) INC 4 Lake Road, Dollard des Ormeaux, Quebec, H9B
Lambda Electronics
Original
Lambda VEGA 650 klaasing Lambda VEGA 900 EN60068-2 Powerware Plus 40 217F 150-264V EN61000-3-2 CH-8166 CA92154

w2f transistor

Abstract: klaasing terminals 3. Contact Lambda to validate configuration and issue a part number Vega Datasheet 23 Jun 03 , , Australia Tel: +61 88 2773288 Fax: +61 88 2764024 JAPAN DENSEI LAMBDA KK, 1-11-15 Higashigotanda, Shinagawa-Ku, Tokyo 141, Japan Tel: +81 3 3447 4411 Fax: +81 3 3447 7784 AUSTRIA LAMBDA ELECTRONIC GmbH , LAMBDA KK, 6F Sungok Bldg, 4-1 Soonae-Dong, Boondang-Gu Sungnam-Shi, Kyonggi-Do, Korea Tel: +82 2 556 , Tel: +32 3 6601320 Fax: +32 3 6649901 CANADA LAMBDA ELECTRONICS (CANADA) INC 4 Lake Road, Dollard
LAMBDA
Original
w2f transistor ibanez w2f 48 Amtek Lambda VEGA VEGA 650 264VAC 330VDC 250VAC

LWT-2H-522

Abstract: lwt-3h-5ff Part i - AC-to-DC Power Supplies LAMBDA'S LW SERIES Universal Inputs Designed For International Applications Lambda's LW Series of dual, triple and quad output power supplies provide a high , outputs). Lambda's LW Series are the ideal power supplies for designs that require a small footprint without a big price tag. 54 LAMBDA ELECTRONICS ING.A 575 Broad Hollow Rd., Melville, NY 11747-3700 â'¢ 1-800-LAMBDA-4 LW SERIES SPECIFICATIONS AC input line . .85-265VAC, 47-440Hz. on LWD and LWT
-
OCR Scan
LWT-2H-522 lwt-3h-5ff LWT-3H-522 lambda lwt-3h-5ff Lambda electronics Power supply LWT-4HA-522 LWT-4HA-5FF 110/220VAC 1-800-LAMBDA-4 47-440H 85-132/170-265VAC LWD-15 LWD-30

lfs-48-24

Abstract: voltage inverter 12v to 220v 50Hz 1500w electronic developed by Lambda providing inherently reliable operation in transient line and load conditions, in , with the controlled manufacturing and quality standards {always expected of Lambda) makes the LFS , (inches) LAMBDA'S CHOICE (A)* QTY. 1 QTY. 10 PRICE QTY. QTY. 25 100 QTY. 250 QTY. 1000 MODEL 1.8V TO , 465 520 652 848 1022 421 470 585 795 962 LFS-46-2 LFS-47-2 LFS-48-2 LFS-49-2 LF5 , 981 1198 465 520 652 848 1022 421 470 585 795 962 LFS-46-5 LFS-47^5 LFS-48-5 LFS-49-5 LFS-50-5 17
-
OCR Scan
LFS-52 lfs-48-24 voltage inverter 12v to 220v 50Hz 1500w electronic LAMBDA lfs-46-24 lambda lfs-48-28 28V DC regulated power supply LAMBDA lfs LFS-41-12 170-265VAC 3750VRMS 1500VRMS 500VRMS LFS-46

HWS300-1800

Abstract: B 30348 42 135±0.5 160±1 19MAX 42±1 *see website for all outline drawings Other Lambda , warranty (See Lambda's terms & conditions) (3) UL60601-1, EN60601-1, see options table 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 41 HWS Series Output Ratings (10.1) VOLTAGE , 1-800-LAMBDA-4 Revision A9: Aug 2008 -
-
Original
HWS15 HWS50 HWS100 HWS150 HWS300-1800 B 30348 HWS15-5 HWS30-24 UL508 265VAC 100/200VAC HWS30

Invensys

Abstract: EN133200 480,000 521,000 421,000 395,000 (Notel): Value for Ta ^ 50°C. For Ta>50°C derate according to the , '" ih MB13-SERIES LAMBDA An Invensys Company MB1310 MB1320 MB1330 150±1 (26 A) MB1340 MB1350 ® (15) ® (Unit: mm) MB13-SERIES LAMBDA An Invensys company â  Typical Insertion Loss (1
-
OCR Scan
EN133200 Invensys Three phase inverter with delta connection Invensys mtbf UL1283 50/60H 2500VAC

lambda oxygen sensor

Abstract: lambda-sensor LM9040 Dual Lambda Sensor Interface Amplifier General Description Features The LM9040 is a , designed for use with conventional Lambda Oxygen Sensors The Lambda Sensor is used for monitoring the , internally set and can directly convert the Lambda sensor output voltage to a level suitable for A D , Corporation TL H 12372 RRD-B30M115 Printed in U S A LM9040 Dual Lambda Sensor Interface Amplifier , (ZDIFF) This bias voltage is similar to the Lambda Sensor output voltage at the stoichiometric air-fuel
National Semiconductor
Original
lambda oxygen sensor lambda-sensor Lambda Sensor oxygen sensor bypass 286E-13 sensor lamb

lambda signal processor

Abstract: DSP56000 activated. 4.2 Generalized Prediction Controllers 4.2.1 Implementation The scheme for generalized , */ typedef struct { int n,na; float theta[4],fi[4]; float p0,v_conv,tr_min,tr_max; float eps,eps1,lambda , serial model at time tk */ pest->eps1 = 0.0; /* output of serial model at time tk-1 */ pest->lambda = , ; pest->diag[0] = pest->diag[0]/alphaj/pest->lambda; if (pest->n > 1) { kf = 0; ku = 0; for (j=1 ; j , ; ajlast = alphaj; alphaj = ajlast + vj * fj; pest->diag[j] = pest->diag[j] * ajlast/alphaj/(pest->lambda
Motorola
Original
DSP56001 lambda signal processor DSP56000 PPAP DSP56000/DSP56001 DSP56000CLASA DSP56000/

LAMBDA LOD-X

Abstract: dual tracking linear power supply PART IBâ'"AC-TO-DC LINEAR POWER SUPPLIES Lambda's LN Series is ideal for low power military , and follows through with component selection â'" and Lambda uses only quality driven components in the , : 1.5mV RMS. Regulation: 0.1% line and load. El Lambda's LN Series is manufactured using only the highest , °C 50X 60°C 71'C COMPLETE ELEC SPEC PG. COMPLETE MECH. 5PEC. PG. DIMENSIONS (inches) LAMBDA'S CHOICE , ) LAMBDA'S CHOICE (A)* QTY. 1 PRICE QTY 10 QTY. 25 MODEL 24V ±5% ADJ. 0.9(,81) 0.75(.68) 0.6(.55) 0.4
-
OCR Scan
LAMBDA LOD-X dual tracking linear power supply Lambda power supply LND-P-152 LND-P-152 LNS-Y-24 MIP 289 MIL-STD-810 48VDC

delta motor

Abstract: delta inverter (typ) 1800g 1800g 1800g 2800g 2800g 15 ; MTBF(hours) (Nöte 2) 573,000 480,000 521,000 ".' 421,000 , motor. 141 MB13-SERIES LAMBDA densei-lambda MB1310 MB1320 MB1330 150±1 170 MAX (15) ? r Â
-
OCR Scan
delta motor delta inverter Densei-Lambda 100MQ

LAMBDA ems SERIES

Abstract: prepaid energy meter block diagram INSTRUCTION MANUAL FOR RSTL 488 PROGRAMMER 83-468-004 Revision J SERIAL NUMBER_ LAMBDA EMI , Lambda EMI as a component for use in the composition of an apparatus as defined in Article 1 (1) of the , environment as defined by Lambda EMI, for the products described by this manual is stated as follows: The , Electrostatic Discharge (ESD) Sensitive Device Page: 83-000-007 Rev D TWO YEAR WARRANTY Lambda EMI (405 Essex , a period of TWO YEARS from the date of initial shipment. Lambda EMI will service and, at its option
-
OCR Scan
LAMBDA ems SERIES prepaid energy meter block diagram talking energy meter circuit diagram DIAGRAM TV POWER SUPPLY pc power supply repair by diagram power supply diagram 89/336/EEC RS232

Schaffner NSG

Abstract: Schaffner* CDN 125 . 90 3 LAMBDA Introduction This report presents a concise view of all the rugged , general support information. 4 LAMBDA Electro-Static Discharge Test EN61000 , , these points include the UUT's chassis and input/output 5 LAMBDA terminals. The test voltages , or signs of failure. 6 LAMBDA TEST RESULTS: 1. No connections to UUT. Level 1 : 2 kV Test , 1 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 LAMBDA 3. Input
Lambda Electronics
Original
Schaffner NSG Schaffner* CDN 125 Schaffner NSG 433 nsg650 schaffner cdn 110 Schaffner CDN 125 UE1500 EN55BAV EN55BQP FCC15JA

LAMBDA ems SERIES

Abstract: talking energy meter circuit diagram INSTRUCTION MANUAL FOR 567/ 352*5$00(5 83-468-004 Revision H SERIAL NUMBER LAMBDA EMI , DECLARATION INTENDED PURPOSE (USE) The Power Supplies described by this manual are defined by Lambda EMI as , environment as defined by Lambda EMI, for the products described by this manual is stated as follows: The , Functional earth (ground) 83-000-007 Revision C WARRANTY Lambda EMI (405 Essex Road, Neptune, N.J , years from the date of initial shipment. Lambda EMI will service and, at its option, repair or replace
-
Original
LAMBDA EMS emhp, electronic measurements inc IEEE-488 general purpose interface bus LAMBDA mc series 92/31/EEC

Three phase inverter with delta connection

Abstract: delta VL inverter MB13-SERIES Three Phase Input Noise Filter with Block Terminal LñMBDñ/k densei-lambda â  Features (1) Block Terminal with Cover Simple wire connection by block terminal. High safety by terminal cover. (2) Three Phase Power Line Filter Available for Star connection : 400Vac line-line Available for Delta connection : 200Vac line-line (3) High Attenuation in Compact Package â  Safety standard , MTBF.(hours) (Note 2) 573,000 480,000 521,000 421,000 395,000 ; - (Notel): Value for Ta s 50°C. For
-
OCR Scan
delta VL inverter delta connection 100MC

omega MML400 COUTANT LAMBDA

Abstract: MML200 standard Omega unit which fully meets your requirements, the Coutant Lambda team will create a customised , . This is the part number of your customised unit. It contains the information that Coutant Lambda need , if not required to inhibit. *Consult the Technical Support team at Coutant Lambda for more details , . *Consult the Technical Support team at Coutant Lambda. Case Options U Case: DD Case: Order Codes , 294 3.15 MML800 6 375 329 4.2 MML800 7 398 352 4.4 MML800 8 421 375 4.6 Refer to
-
Original
400PFC MML200 MML400 MML600 MML600DD MML400X omega MML400 COUTANT LAMBDA omega MML400 Lambda MML400 EN55022 MML600T1 MML600T2

omega MML400 COUTANT LAMBDA

Abstract: MML200 standard Omega unit which fully meets your requirements, the Coutant Lambda team will create a customised , . This is the part number of your customised unit. It contains the information that Coutant Lambda need , if not required to inhibit. *Consult the Technical Support team at Coutant Lambda for more details , . *Consult the Technical Support team at Coutant Lambda. Case Options U Case: DD Case: Order Codes , 294 3.15 MML800 6 375 329 4.2 MML800 7 398 352 4.4 MML800 8 421 375 4.6 Refer to
-
Original
omega 400pfc coutant power supply coutant lambda omega omega MML400 e coutant lambda omega series omega MML600 MML600T4 MML600T5 MML600T6 MML600U1 MML600U2 MML600U3
Showing first 20 results.