500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
POWEREST Texas Instruments Power Estimation Tool (PET)
SOLARMAGIC-SOLARPOWEROPTIMIZER-REF Texas Instruments SolarMagic SM3320-RF-EV Solar Power Optimizer with RF Communications Reference Design
MSP430-3P-PCC-LIFETIMEPOWEREVALDEVKT Texas Instruments Lifetime Power? Evaluation and Development Kit
POE-PD-POWER-REF Texas Instruments LM5072 5V out 25W IEEE 802.3at Compliant POE+ PD Power Reference Design
TPD3S044DBVR Texas Instruments Current-Limit Switch and D+/D- ESD Protection for USB Host Ports 6-SOT-23 -40 to 85
LPV324ID Texas Instruments Quad, Low-Voltage, Low Power, RRO 14-SOIC -40 to 125

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : PT07A10-6P-GALAXY Supplier : Amphenol Manufacturer : Newark element14 Stock : - Best Price : $31.06 Price Each : $42.35
Shipping cost not included. Currency conversions are estimated. 

Galaxy Power converter

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Data Sheet February 2008 GALAXY Power System GPS2424/30 +24V Output, Maximum 1000A, 2000A, 3000A 1000A GPS2424/30 half-height cabinet mounted on Unigy II batteries. GALAXY Power System , with streamlined plant control and monitoring, the high-performance GALAXY Power System (GPS) 2424/30 , GALAXY Power System GPS2424/30 Simplified Engineering, Installation, and Maintenance The GPS2424/30 , power, a maximum of four 3 A, highefficiency converter cards can be installed in a carrier. In cases Lineage Power
Original
596B4 596B5 DS03-025 GPS2424 galaxy vector controller lineage 2000 power plant controller Galaxy rectifier controller galaxy IR125 DS03-024 DS03-041
Abstract: Converter Interface Card (CIC) is required for each converter carrier. Converters 5 - 1 Galaxy Power , Converter Front Panels Issue 8 January 2008 Converters 5 - 3 Galaxy Power System 2424 6 AC , Galaxy Power System 2424 (GPS 2424) H569-437 User's Guide Select Code 167-792-159 Comcode , January 2008 Galaxy Power System 2424 (GPS 2424) H569-437 Notice: The information, specifications , Reserved Printed in U.S.A. Galaxy Power System 2424 Table of Contents 1 Introduction GPS 2424 Lineage Power
Original
596B4 alarm code 167-792-180 GALAXY MILLENNIUM Galaxy Power H569 troubleshooting and repair lcd monitors
Abstract: Installation Guide for Galaxy Power Systems Note: Instructions in this manual reference , 108327362 Issue 10 February 2008 Installation Guide for Galaxy Power Systems Notice: The , Power All International Rights Reserved Printed in U.S.A. Installation Guide for Galaxy Power , Installation Guide for Galaxy Power Systems 6 Centralized or Distributed Architecture Connections , System Shunt for Galaxy Vector Controller Distributed Architecture Intercabinet DC Power Bus Lineage Power
Original
J85582C-1 Bus Bar torque for metric bolts Galaxy Power GPS 4848/100 j85582 595lta KS-20472 SW300 SW100 SW200
Abstract: product manual describes the Lineage Power GCM2 and GCM3 versions of the Galaxy Vector Controller. These controllers are an integral part of various Lineage Power GPS (Galaxy Power System) and OPS (Outdoor Power , Galaxy Vector Controller GCM2, GCM3 In addition to rectifier and converter control, the Vector , internally in Lineage Power rectifiers. 3 - 4 Operation Issue 4 January 2008 Galaxy Vector , Galaxy Vector Controller GCM2, GCM3 Product Manual Select Code 167-792-115 Comcode 108894403 Lineage Power
Original
lineage rectifier tyco NP2500 NP2500 TYCO 596A RECTIFIER rectifier tyco NP2500 NP2500 RECTIFIER circuits TYCO np2500 RECTIFIER
Abstract: GALW9V647 ­ 1 Galaxy Power Inc. 155 Flanders Road Westborough, MA 01581 e-mail , No. 05-GAL-01 Rev. 0.6 ­ 042205 Galaxy Power Inc. Fax: 508-870-9796 e-mail , : 508-870-9796 GALW9V647 ­ 3 Galaxy Power Inc. 155 Flanders Road Westborough, MA 01581 e-mail , the ON/OFF pin or power to the converter. This advanced feature prevents the converter from damaging , converter requires cycling the ON/ OFF pin or power to the converter. If non-latching is required, consult Bel Fuse
Original
Galaxy Power, Inc DC DC converter MICROCONTROLLER based gal01 48VDC GALW9V647E
Abstract: Galaxy Power System 2424 (GPS 2424) H569-437 User's Guide Select Code 167-792-159 Comcode , Comcode 108305251 Issue 5 June 2000 Lucent Technologies Galaxy Power System 2424 (GPS 2424) H569 , All Rights Reserved Printed in U.S.A. Lucent Technologies Galaxy Power System 2424 Table of , 3-5 3-6 3-6 Table of Contents - 1 Lucent Technologies Galaxy Power System 2424 Pushbutton , Technologies Galaxy Power System 2424 7 Battery Connection Panels Overview Function Illustrations 8 Lucent Technologies
Original
lucent gps 2424 ED83143-30 lucent 596B4 Lucent 80A cabinet BSM 225 LUCENT LINEAGE 596b4
Abstract: Galaxy Power System Verification Procedures User's Guide Select Code 167-792-010 Comcode , January 2008 Galaxy Power System Verification Procedures Notice: The information, specifications , Reserved Printed in U.S.A. Galaxy Power System Verification Procedures Table of Contents 1 , Galaxy Power System Verification Procedures 3 Galaxy Millennium Controller Performance , 4-2 4-2 4-3 4-4 4-5 4-5 Issue 3 January 2008 Galaxy Power System Verification Procedures -
Original
fuse 9 BJE 41 lucent 595A 596A ks22010 lucent 595B 596B3 J855- J874-S RS-232
Abstract: Galaxy Power's CoolConverterTM line of high-efficiency DC/DC converters. Very Low Common-mode Noise , ® Certified to ISO 9001:2000 Part No. 05-GAL-01 Rev. 1.0 ­ 033105 Galaxy Power Inc. 155 Flanders Road , GALW9V647 ­ 2 Galaxy Power Inc. TBD 155 Flanders Road Westborough, MA 01581 Telephone , 79 79.5 80 80.5 Input Voltage (V) Part No. 05-GAL-01 Rev. 1.0 ­ 033105 Galaxy Power , / OFF pin or power to the converter. If non-latching is required, consult factory. Control Options Galaxy Power
Original
sensors Galaxy s MTBF 1002 calculation
Abstract: power eighth-brick DC/DC converter in the industry. Industry Standard Pinout and Footprint No Heat , ISO 9001:2000 Part No. 02-GAQ-04 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road , Notes CoolConverterTM Galaxy's proprietary CoolConverterTM provides: · Patented single-stage power , No. 02-GAQ-04 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road WWW.GALAXYPWR.COM , off. To re-enable the converter requires cycling the ON/ OFF pin or power to the converter. If Galaxy Power
Original
GAQW2V040
Abstract: Settings Memory Battery Wiring the Basic Controller Power and Shunt Inputs Rectifier/Converter , . Part 1 describes the basic features of the Lineage Power Galaxy Millennium Controller, Model J85501K , telecommunications power equipment. It can control large battery plants containing up to 64 Galaxy serial , generators, converter plants, and inverters. Design Structurally, the core of the Galaxy Millennium , Galaxy Millennium Controller that has been factory installed in the initial bay of a new Galaxy Power Lineage Power
Original
J85501K-1 of RAS 0510 relay relay RAS 0510 j85501k part 2 RAS 0510 relay 3avr GALAXY MILLENNIUM Controller J85501k-1 1999/5/EC
Abstract: -9: Converter Plant Issue 2 January 2008 B-2 B-4 List of Tables - 1 Galaxy Rack-Mounted Vector , Information This product manual describes the Lineage Power Galaxy Rack-Mounted Vector Controller, J85501M , Galaxy Rack-Mounted Vector Controller J85501M-1 Product Manual Select Code 167-792-117 , , specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear in this document. © 2008 Lineage Power All International Rights Lineage Power
Original
np2500* shelf application note rectifier tyco NP2500 circuit diagram FAJ ESD tyco np1200 Galaxy protocol TYCO np1500 RECTIFIER
Abstract: 9001:2000 Part No. 02-GAM-04 Rev. 1.0 ­ 042805 Galaxy Power Inc. 155 Flanders Road , WWW.GALAXYPWR.COM GAMW2V040 ­ 2 Galaxy Power Inc. UL and c-UL Recognized Component, TUV*, UL60950, CSA , Notes CoolConverterTM Galaxy's proprietary CoolConverterTM provides: · Patented single-stage power , 80.5 Input Voltage (V) Part No. 02-GAM-04 Rev. 1.0 ­ 042805 Galaxy Power Inc. 155 Flanders , power to the converter. If non-latching is required, consult factory. Control Options: As the Galaxy Power
Original
Abstract: Galaxy Power System Verification Procedures User's Guide Select Code 167-792-010 Comcode , Comcode 108639659 Issue 1 March 2000 Galaxy Power System Verification Procedures Notice: Every , Printed in U.S.A. Lucent Technologies Galaxy Power System Verification Procedures Table of , of Contents - 1 Lucent Technologies Galaxy Power System Verification Procedures 3 Galaxy , Galaxy Power System Verification Procedures Backup System Configuration Replace Memory Backup Battery -
Original
LUCENT 50A RECTIFIER lineage 2000 ecs KS22012 lucent comcode lucent galaxy controller gps4848
Abstract: power eighth-brick DC/DC converter in the industry. Industry Standard Pinout and Footprint No Heat , ISO 9001:2000 Part No. 02-GAQ-05 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road , Notes CoolConverterTM Galaxy's proprietary CoolConverterTM provides: · Patented single-stage power , (V) Part No. 02-GAQ-05 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road , converter is latched off. To re-enable the converter requires cycling the ON/ OFF pin or power to the Galaxy Power
Original
GAQW1V840 18V-20A
Abstract: 9001:2000 Part No. 02-GAM-07 Rev. 1.0 ­ 042805 Galaxy Power Inc. 155 Flanders Road , WWW.GALAXYPWR.COM GAMW1V240 ­ 2 Galaxy Power Inc. UL and c-UL Recognized Component, TUV*, UL60950, CSA , Notes CoolConverterTM Galaxy's proprietary CoolConverterTM provides: · Patented single-stage power , Input Voltage (V) Part No. 02-GAM-07 Rev. 1.0 ­ 042805 Galaxy Power Inc. 155 Flanders Road , converter on requires either cycling the ON/OFF pin or power to the converter. This advanced feature Galaxy Power
Original
Abstract: 9001:2000 Part No. 02-GAM-01 Rev. 1.0 042805 Galaxy Power Inc. 155 Flanders Road , requirements. 35 grams Telcordia (Bellcore) TBD WWW.GALAXYPWR.COM GAMW5V020 ­ 2 Galaxy Power , Voltage (V) Part No. 02-GAM-01 Rev. 1.0 042805 Galaxy Power Inc. 155 Flanders Road , off. To re-enable the converter requires cycling the ON/ OFF pin or power to the converter. If , Galaxy Power for your special needs. Trim: To trim the output voltage higher, connect the required Galaxy Power
Original
Abstract: power eighth-brick DC/DC converter in the industry. Industry Standard Pinout and Footprint No Heat , ISO 9001:2000 Part No. 02-GAQ-01 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road , Notes CoolConverterTM Galaxy's proprietary CoolConverterTM provides: · Patented single-stage power , No. 02-GAQ-01 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road WWW.GALAXYPWR.COM , off. To re-enable the converter requires cycling the ON/ OFF pin or power to the converter. If Galaxy Power
Original
GAQW5V020 8136-V
Abstract: Rights Reserved Printed in U.S.A. Galaxy Pulsar Plus Power System Controllers Table of Contents , . 5 Galaxy Pulsar Plus Power System Controllers , . 10 Galaxy Pulsar Plus Power System Controller Overview , . 106 Issue 5.0 May 2008 3 Galaxy Pulsar Plus Power System Controllers Overview , . 182 Issue 5.0 May 2008 4 Galaxy Pulsar Plus Power System Controllers 1 GE
Original
CC848815341 NE843 Galaxy Pulsar Plus Lucent Technologies 12IR150 battery NE843E cc109133427 Galaxy Pulsar Plus installation guide NE843G ES772
Abstract: Wiring the Basic Controller Power and Shunt Inputs Rectifier/Converter Interfaces Alarms Outputs , Converter to Galaxy Testing the OS to PAD General Operational Considerations Galaxy TL1 Configuration , Connections from Galaxy Aux Port TB2 to RS-232/485 Converter D-5 Table D-4: PAD Messages 2 - List of , monitors and controls peripheral power equipment, including standby generators, converter plants, and , initial bay of a new Galaxy Power System. Perform these procedures as part of the total plant -
Original
lineage 2000 power plant lineage 2000 BDFB FUSES lineage 2000 power plant ECS ats amf MJFR BSJ1
Abstract: power eighth-brick DC/DC converter in the industry. Industry Standard Pinout and Footprint No Heat , ISO 9001:2000 Part No. 02-GAQ-06 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road , Notes CoolConverterTM Galaxy's proprietary CoolConverterTM provides: · Patented single-stage power , (V) Part No. 02-GAQ-06 Rev. 3.0 ­ 041405 Galaxy Power Inc. 155 Flanders Road , converter is latched off. To re-enable the converter requires cycling the ON/ OFF pin or power to the Galaxy Power
Original
GAQW1V540 Galaxy note Semiconductor
Showing first 20 results.