500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
X40435S14-B Intersil Corporation 3-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO14, PLASTIC, SOIC-14 visit Intersil
X40435S14IZ-A Intersil Corporation 3-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO14, 0.150 INCH, ROHS COMPLIANT, SOIC-14 visit Intersil
X40435V14-B Intersil Corporation 3-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO14, 4.40 MM, PLASTIC, MO-153AC, TSSOP-14 visit Intersil
X40435V14IZ-A Intersil Corporation 3-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO14, 4.40 MM, ROHS COMPLIANT, PLASTIC, MO-153AC, TSSOP-14 visit Intersil
X40435S14I-AT1 Intersil Corporation 3-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO14, 0.150 INCH, SOIC-14 visit Intersil
X40435S14Z-AT1 Intersil Corporation 3-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO14, 0.150 INCH, ROHS COMPLIANT, SOIC-14 visit Intersil

DIN VDE 0110 0435

Catalog Datasheet MFG & Type PDF Document Tags

V23127-A0006-A101

Abstract: V23127 d0006-a402 nach DIN IEC 255 Teil 1-00/VDE 0435 Teil 201 auf Anfrage. 4.39 Kartenrelais E Lastgrenzkurven , ,Regeln für elektrische Relais in Starkstromanlagen" (VDE 0435/9.72) und der ,sicheren elektrischen , deren Zubehör für den Heimgebrauch" VDE 0860 (DIN IEC 65) werden erfüllt ­ Entspricht den , Kontaktseite Kontaktklasse III nach VDE 0435 Teil 120/10.81 Anh. B Bestellbezeichnung Block 3 A101 A201 , ) Schaltspannung max. nach VDE 0110 Gruppe C Schaltstrom max. Schaltleistung max.2) Gleichspannung
Siemens Electromechanical Components
Original

vde 0435

Abstract: relais vde 0435 . Die Kriech- und Luftstrecken nach VDE 0110 entsprechen den Isolationsgruppen B bzw. C für die , UNenn Arbeitsbereich nach VDE 0435 T201 Klasse 1 Ansprechklasse nach VDE 0435 T201 b , Kontaktklasse nach VDE 0435 T120 Schaltleistung, ohmsche Last U, I, P 1 Schließer, 1 Wechsler AgNi III A , Isolation Isolationsaufbau nach VDE 0110/02.79 staubgeschützte Ausf. Gruppe B waschdichte Ausf. Gruppe C 0,7 AC 250 V, DC 300 V AC 250 V, DC 300 V VDE 0110 T1 und T2/01.89 zunächst nur gültig
-
Original
vde 0435 relais vde 0435 DA relais Relais AZ relais AZ 10 6DSA 8-1CH-24DSEA D-82178 D-46535 D-88048 NL-2803 B-3300

V23077-A1005-A402

Abstract: V23077 elektrische Kennwerte entsprechen den ,Regeln für elektrische Relais in Starkstromanlagen" (VDE 0435/9.72 , Kontaktseite Kontaktklasse III nach VDE 0435 Teil 120/10.81 Anh. B Kontaktwerkstoff Silber-Cadmium-Oxid Kontaktkurzzeichen 1 2 Schaltzeichen (siehe auch Anschlußbelegung) Schaltspannung max. nach VDE 0110 Gruppe C nach VDE 0110 Gruppe B 2) V­ V~ V~ 300 250 380 Schaltstrom max. A 25 3 , -00/VDE 0435 Teil 201) U II = Maximale Dauerspannung bei 20 °C für Tsp max = 140 °C ohne
Siemens Electromechanical Components
Original
V23077 V23077-A1005-A402 v23077a1005a402 monostabil V23077-A100 V23077-A1005 1-00/VDE

relay vde 0435 VDE 0110

Abstract: mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r Accessories see page 52 . 55 + 63 , mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r (857-358: r pending) WAGO , Dielectric strength contact-coil Surge capacity open contact Nominal voltage acc. to VDE 0110 Part 1/4.97 , Description JUMPFLEX® relay socket with miniature switching relay, for DIN 35 rail VN DC 12 V DC 24 V DC , -25 °C . +60 °C -40 °C . +70 °C 6 x 81 x 94 Height from upper-edge of DIN 35 rail CAGE CLAMP®S
WAGO Kontakttechnik
Original
relay vde 0435 VDE 0110 D-32385 D-32423

V23061-B1005-A401

Abstract: V23061-B1007-A401 ,Regeln für elektrische Relais in Starkstromanlagen" (VDE 0435/9.72) und der ,sicheren elektrischen , Kontaktklasse III nach VDE 0435 Teil 120/10.81 Anh.B Bestellbezeichnung Block 3 Kontaktwerkstoff , Kontaktkurzzeichen Schaltzeichen (siehe auch Anschlußbelegung) Schaltspannung max. nach VDE 0110 Gruppe C nach VDE 0110 Gruppe B 2) A401 21 1 V­ V~ V~ A 300 250 380 8/15 3) W , Teil 1-00/VDE 0435 Teil 201) U II = Maximale Dauerspannung bei 20 °C für Tsp max = 115 °C ohne
Siemens Electromechanical Components
Original
V23061 V23061-B1005-A401 V23061-B1007-A401 V23061-A1007-A402 V23061-B1003-A401 V23061-A1005-A402 Starkstrom

relay vde 0435 VDE 0110

Abstract: . +60 °C -40 °C . +70 °C 6 x 81 x 94 Height from upper-edge of DIN 35 rail CAGE CLAMP®S 0.34 mm² . 2.5 mm² / AWG 22 . 14 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN , CLAMP®S 0.34 mm² . 2.5 mm² / AWG 22 . 14 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 , contact-coil Surge capacity open contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 , . Pack. Unit JUMPFLEX® relay socket with miniature switching relay, for DIN 35 rail 24 V DC 110
WAGO Kontakttechnik
Original

relay vde 0435 VDE 0110

Abstract: . 12 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r Accessories see pages 68 , ² . 2.5 mm² / AWG 22 . 12 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r , strength contact-coil Surge capacity open contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 , switching relay, for DIN 35 rail VN 24 V DC 110 V DC 220 V DC IN 10 mA 3.5 mA 3.2 mA Item No , switching operations -25 °C . +60 °C -40 °C . +70 °C 6 x 81 x 94 Height from upper-edge of DIN 35 rail
WAGO Kontakttechnik
Original

relay vde 0435 VDE 0110

Abstract: VDE 0110 0435 / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r Accessories see pages 68 . 71 AgSnO2 VN -15 , VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r (857-358: r pending) WAGO Kontakttechnik GmbH & Co , Dielectric strength contact-coil Surge capacity open contact Nominal voltage acc. to VDE 0110 Part 1/4.97 , Description JUMPFLEX® relay socket with miniature switching relay, for DIN 35 rail VN 12 V DC 24 V DC 48 V , °C . +60 °C -40 °C . +70 °C 6 x 81 x 94 Height from upper-edge of DIN 35 rail CAGE CLAMP®S solid
WAGO Kontakttechnik
Original
VDE 0110 0435 vde 0435 vde 0110

relay vde 0435 VDE 0110

Abstract: upper-edge of DIN 35 rail CAGE CLAMP®S 0.34 mm² . 2.5 mm² / AWG 22 . 14 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r (857-304: g) 250 V / 4 kV / 3 5 x 106 switching , upper-edge of DIN 35 rail CAGE CLAMP®S 0.34 mm² . 2.5 mm² / AWG 22 . 14 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r (857-358: g) Max. switching voltage Max. continuous , mode Dielectric strength contact-coil Surge capacity open contact Nominal voltage acc. to VDE 0110
WAGO Kontakttechnik
Original

relay vde 0435 VDE 0110

Abstract: / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r (857-368: r pending) 8 WAGO Kontakttechnik , voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Mechanical life Mechanical life at max. load (resistance , 28 . 12 fine-stranded: 0.34 mm² . 2.5 mm² / AWG 22 . 12 9 . 10 mm / 0.37 in VDE 0110 / EN 60664; VDE 0435 / EN 61810-1; r Accessories see page 52 . 55 + 63 AgSnO2 + 5 Au VN -15 % . +20 % , Description JUMPFLEX® relay socket with miniature switching relay, for DIN 35 rail VN DC 24 V DC 110 V DC
WAGO Kontakttechnik
Original

relay vde 0435 VDE 0110

Abstract: vde 0435 timer / IEC 664 / IEC 801 / IEC 255 VDE 0435/ VDE 0110 ­30°C.+70°C ­20°C.+60°C 4 kV / 2 IP 20 IP 50 DIN rail 35 mm Category III green LED yellow LED UL / CSA IEC 529 / IEC 664 / IEC 801 / IEC 255 VDE 0435/ VDE 0110 ­30°C.+70°C ­20°C.+60°C 4 kV / 2 IP 20 IP 50 DIN rail 35 mm Category III , IEC 664/VDE 0110 Protection category IEC 529 - Terminal block - Front Mounting Installation
-
Original
vde 0435 timer TIMER DIN VDE 0110 0435 vde 0435 timer vde 0110 VDE 0435 time relay timer vde 0435 VDE 0110 vde 0110 timer 664/VDE

V23037-A0005-A101

Abstract: V23037-A0002-A101 nach DIN IEC 255 Teil 1-00/VDE 0435 Teil 201 auf Anfrage. 5.33 Kleinschaltrelais E2 , elektrische Relais in Starkstromanlagen" (VDE 0435/9.72) und der ,sicheren elektrischen Trennung von Fernmelde- und Starkstromkreisen" (VDE 0804) ­ Luft- und Kriechstrecken bei Bestückung 2 Schließer 6 mm , III nach VDE 0435 Teil 120/10.81 Anh. B Bestellbezeichnung Block 3 A101 Kontaktwerkstoff A102 , ) 21 ­ 21 2× 21 ­ 21 2× 300 250 101) 1­1 2× Schaltspannung max. nach VDE 0110
-
Original
V23037-A0005-A101 V23037-A0002-A101 V23037-A0005-A401 V23037-A0001-A101 v23037 V23037-A0002-A401 V23037 V23037-A0555 V23037-B0555 ECR0002-J

vde 0435 vde 0110 gr c

Abstract: vde 0435 0110 Gr C rail terminal strips with C AG E CLAMP® terminal strips with C AG E CLAMP® DIN VDE 0106: 1979-02, Gr.2 for A C 250 V DIN VDE 0106: 1979-02, Gr.2 for A C 250 V DIN VDE 0160 and IEC255, DIN VDE 0435 (corresponding parts) DIN VDE 0160 and IEC255, DIN VDE 0435 (corresponding parts) NOTE , VDE 0110/1.89 Mechanical life at max. resistive load Dimensions incl. mounting carrier and relay , 1 C AG E CLAMP® terminal strips (W A G O series 236) Electrical isolation meets D IN/VDE
-
OCR Scan
vde 0435 vde 0110 gr c vde 0435 0110 Gr C

vde 0435 0110 Gr C

Abstract: vde 0435 0110 Gr DIN VDE 0160 and IEC 255, DIN VDE 0435 (correspnding parts) Accessories Push-in type jumper bars , DIN/VDE 0106, part 1 Coil voltage 5/6 V 12V 24 V 48 V 60 V 115V 230 V 2 8 - 14 0 .08 - , operating mode Dielectric strength contact-coil Open circuit Nominal voltage acc. to VDE 0110/1.89 , terminal strips with CAGE CLAMP^ DIN VDE 0106: 1979-02, Gr.2 for A C 250 V DIN VDE 0160 and IEC 255, DIN VDE 0435 (correspnding parts) DC 24 V A C 230 V VN -15 %.+20 % 21 mA A C /D C 250 V 4 s
-
OCR Scan
vde 0435 0110 Gr

DIN VDE-0660

Abstract: vde 0435 - AC DC DIN VDE 0110 1, DIN VDE 0435, DIN VDE 0660 DIN EN 50005 . : . «-0-». . . . . Tu = 40 °C. . 24- (100 %- ) , , . > 10 . 5 -15. . : , , . -
-
Original
DIN VDE-0660 DIN VDE 0110 0435 DIN VDE 0660 vde 0435 0110 VDE0435 VDE0660

relay vde 0435 VDE 0110

Abstract: VDE 0435 time relay according to DIN IEC 255 Part 1-00 or VDE 0435 Part 201 -40 °C . 70 °C Thermal resistance 75 K/W , characteristics comply with the "Rules for electrical relays in power installations" (VDE 0435/9.72) q , Contact category III according to VDE 0435 Part 120/10.81, Appendix B Ordering code, block 3 A301/A302 , IEC 255 Part 1-00 or VDE 0435 Part 201 Minimum release voltage 2/b 10 % of nominal voltage , ): rated voltage pollution severity overvoltage category 250 V 3 III According to VDE 0110 (2/79
-
Original
hole VDE 0435 time relay siemens v23061 relay vde 0435 time relay vde 0435 VDE 0110 group C Siemens V23061-B1005-A401 vde 0435 VDE 0110 timer ECR0001-B C/250 B/380

vde 0435 timer

Abstract: V23061-B1005-A401 /class of energizing voltage according to DIN IEC 255 Part 1-00 or VDE 0435 Part 201 Minimum release , temperature range according to DIN IEC 255 Part 1-00 or VDE 0435 Part 201 -40 °C . 70 °C Thermal , relays in power installations" (VDE 0435/9.72) q Used for safe electrical insulation in the , Relay MSR Contact data Contact category III according to VDE 0435 Part 120/10.81, Appendix B , III According to VDE 0110 (2/79): insulation group/rated voltage C/250 B/380 Dielectric
-
Original
IEC-664 insulation distances timer vde 0435 siemens relay iec V23061 siemens A402

v23056-a0105

Abstract: V23056 0,64 0,58 Angaben über Arbeitsbereich und Ansprechklasse nach DIN IEC 255 Teil 1-00/VDE 0435 , elektrische Relais in Starkstromanlagen" (VDE 0435/9.72) und der ,sicheren elektrischen Trennung von , netzbetriebene elektronische Geräte und deren Zubehör für den Heimgebrauch" VDE 0860 (DIN IEC 65) sowie die , nach VDE 0435 Teil 120 /10.81 Anh. B Kontaktausführung Doppelanschlüsse A101 A102 A103 A401 A402 , Anschlußbelegung) Schaltspannung max. nach VDE 0110 Gruppe C Schaltstrom max. Schaltleistung max
-
Original
V23056 v23056-a0105 V23056-A0102-A401 V23056-A0105-A401 V23056-A0102-A101 V23056-A0105-A101

time relay vde 0435 VDE 0110 group C

Abstract: timer+vde+0435+VDE+0110+syrelec ) Dielectric test voltage according to IEC 255 5 or VDE 0435 Insulation according to standard VDE 0110 group C Protection Housing Degree of terminal protection Conformity to standards NFC 45250 - VDE 0110 - 0435 0660 , mechanically in the event of a break in supply Progress of a cycle displayed Housing for DIN rail mounting , symmetrical DIN rail 35 mm (EN 50002) Weight (g) 24 V +10 % - 42 V -15 % - 48 V +10 % - 110 V -20 % - 127
Crouzet
Original
timer+vde+0435+VDE+0110+syrelec
Abstract: ) Dielectric test voltage according to IEC 255 5 or VDE 0435 Insulation according to standard VDE 0110 group C Protection Housing Degree of terminal protection Conformity to standards NFC 45250 - VDE 0110 - 0435 0660 , mechanically in the event of a break in supply Progress of a cycle displayed Housing for DIN rail mounting , symmetrical DIN rail 35 mm (EN 50002) Weight (g) 24 V +10 % - 42 V -15 % - 48 V +10 % - 110 V -20 % - 127 Crouzet
Original
Showing first 20 results.