500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : CS5525-ASZ Supplier : Cirrus Logic Manufacturer : Avnet Stock : - Best Price : €4.8952 Price Each : €7.1340
Part : CS5525-ASZ Supplier : Cirrus Logic Manufacturer : Avnet Stock : - Best Price : $4.0251 Price Each : $4.9540
Part : CS5525-ASZ Supplier : Cirrus Logic Manufacturer : Avnet Stock : - Best Price : $4.2166 Price Each : $7.8085
Part : CS5525-ASZR Supplier : Cirrus Logic Manufacturer : Avnet Stock : - Best Price : $4.0251 Price Each : $4.9540
Part : CS5525-ASZR Supplier : Cirrus Logic Manufacturer : Avnet Stock : - Best Price : $4.0604 Price Each : $4.0760
Part : CS5525-ASZR Supplier : Cirrus Logic Manufacturer : Avnet Stock : - Best Price : €3.9495 Price Each : €4.9368
Part : CS5525-ASZ Supplier : Cirrus Logic Manufacturer : Newark element14 Stock : 3 Best Price : $4.11 Price Each : $7.10
Shipping cost not included. Currency conversions are estimated. 

CS5525/26 Datasheet

Part Manufacturer Description PDF Type
CS5525/26 Cirrus Logic 16-Bit/20-Bit Multi-Range A/D Converters with 4-Bit Latch Original
CS5525-26 Cirrus Logic 16-Bit-20-Bit Multi-Range A-D Converters with 4-Bit Latch Original

CS5525/26

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: INTRODUCTION This application note details the interface of Crystal Semiconductor's CS5525/26 , INTERFACE The CS5525/26 interfaces to the 68HC05 through either a three-wire or a four-wire interface , . CS5525/26 68HC05 SDO, Serial Data Out, is the data signal used to transfer output data from the ADC to the 68HC05. CS5525/26 68HC05 CS No Connect CS PA0 SDI MOSI (PD3) SDI , describes how to initialize the 68HC05 and the CS5525/26, perform a self-offset calibration, modify the Crystal Semiconductor
Original
CS5526 motorola 68hc05 AN89 IS555 M68HC05 AN89REV1
Abstract: . 9) Is calibration required to use the converter? When the CS5525/26 is reset, the registers are , registers actually mean? There are two internal read/write calibration registers in the CS5525/26 (offset , required for each gain getting? The CS5525/26 can be gain calibrated with some input signal other than , . 13) Why does the offset move when the CS5525/26 with a 2.5 V reference, is calibrated several times , noise performance from the CS5525/26? Use the bipolar mode or increase the reference voltage, since Cirrus Logic
Original
CS5504 CS5529 80C51 CS5525/6/9 DS202TB1
Abstract: INTRODUCTION This application note details the interface of Crystal Semiconductor's CS5525/26 , included in the Appendix at the end of this note. ADC DIGITAL INTERFACE The CS5525/26 interfaces to , . CS5525/26 PIC16F84 The ADC's serial port consists of four control lines: CS, SCLK, SDI, and SDO , , is the data signal used to transfer output data from the ADC to the PIC16F84. CS5525/26 , initialize the PIC16F84 and the CS5525/26, perform a self-offset calibration, modify the CS5525/26 gain Crystal Semiconductor
Original
PIC16 AN88REV1 PIC16F844 pic16f84 application pic16F84 series PIC16F84 spi PIC16F84 16 16c84
Abstract: AN152 Application Note USING THE CS5521/23, CS5522/24/28, AND CS5525/26 CHARGE PUMP DRIVE FOR , . CS552X Overview The CS5521/23, CS5522/24/28, and CS5525/26 series of A/D converters include a , , & CS5525/26 - 10 K + 0.1 uF - 10 K NBV CPD 1N4148 External Load 1N4148 , instrumentation amplifier (approximately 450 uA for the CS5525/26; 375 uA for the CS5521/23; and 700 uA for the , . Figure 7 illustrates load current vs. CPD frequency for the CS5525/26 devices. The charge pump clock Cirrus Logic
Original
CS5522 id2c1 BAT85 inverter vfc 1200 CS5525/261 CS5521/22/23/24/28 AN152REV1
Abstract: (Not to Scale) DS202PP4 7 CS5525 CS5526 GENERAL DESCRIPTION The CS5525/26 include a (CPD , . Theory of Operation The CS5525/26 also includes a fourth order deltasigma modulator, a calibration , operating from a 32.768 kHz watch crystal or equivalent clock. The CS5525/26 A/D converters are designed , Characteristics section on page 3 for details. Figure 1 illustrates the CS5525/26 connected to generate its own negative bias supply using the onchip CPD (Charge Pump Drive). This enables the CS5525/26 to measure Crystal Semiconductor
Original
11.0592mhz crystal oscillator R1R8 precision timer 50-60hz LSB16 CS5526-BS CS5526-BP DS202DB3 CDB5525/26
Abstract: unipolar or bipolar signals in process control and medical applications. The CS5525/26 also include a , . The CS5525/26 include a CPD (Charge Pump Drive) output (shown in Figure 1). CPD provides a negative , and capacitors. This enables the CS5525/26 to measure negative voltages with re- spect to ground, making the converters ideal for thermocouple temperature measurements. Theory of Operation The CS5525/26 , the CS5525/26 connected to generate their own negative bias supply using the on-chip CPD (Charge Pump -
OCR Scan
RRUS 01 B1 DS202DB5 SS33S CDB5525 CDB5526
Abstract: process control and medical applications. Theory of Operation The CS5525/26 A/D converters are , Analog Characteristics section on page 3 for details. Figure 1 illustrates the CS5525/26 connected to , CS5525/26 to measure ground referenced signals with magnitudes down to NBV (Negative Bias Voltage , negative supply voltage or a resistive divider as illustrated in Figure 3. The CS5525/26 also include a , . The CS5525/26 include a CPD (Charge Pump Drive) output (shown in Figure 1). CPD provides a negative Cirrus Logic
Original
2N5087 BAV199 optoisolator interface with 8051
Abstract: low-level unipolar or bipolar signals in process control and medical applications. The CS5525/26 also , rates. The CS5525/26 include a CPD (Charge Pump Drive) output (shown in Figure 1). CPD provides a , diodes and capacitors. This enables the CS5525/26 to measure negative voltages with re- spect to ground , the CS5525/26 connected to generate their own negative bias supply using the on-chip CPD (Charge Pump Drive). This enables the CS5525/26 to measure ground referenced signals with magnitudes down to NBV -
OCR Scan
LM337 TO-3 xtal.32.768
Abstract: required to use the converter? When the CS5525/26 is reset, the registers are set to known values. If the , internal read/write calibration registers in the CS5525/26 (offset, and gain). One LSB in the offset , : The CS5525/26 can be gain calibrated with some input signal other than full scale. For example, when , CS5529 FAQs 13) Why does the offset move when the CS5525/26 with a 2.5 V reference, is calibrated , performance from the CS5525/26? A: Use the bipolar mode or increase the reference voltage, since each of Cirrus Logic
Original
20pin 4bit adc CS5529-AP CS5529-AS 5529PI DS246PP1 PI246PP1 D-82211
Abstract: process control and medical ap­ plications. The CS5525/26 also includes a fourth order deltasigma , CS5525/26 include a (CPD) charge pump drive output (shown in Figure 1) which provides a negative bias , and capacitors. This enables the CS5525/26 to measure negative voltages with re­ spect to ground, making it ideal for thermocouple temperature measurements. Theory o f Operation The CS5525/26 A/D , . See the Analog Character­ istics section on page 3 for details. Figure 1 illustrates the CS5525/26 -
OCR Scan
Abstract: . The CS5525/26 also includes a fourth order deltasigma modulator, a calibration microcontroller, a , 32.768 kHz watch crystal or equivalent clock. CS5525 CS5526 The CS5525/26 include a (CPD) charge pump , amplifier when used with a combination of ex ternal diodes and capacitors. This enables the CS5525/26 to , measurements. Theory of Operation The CS5525/26 A/D converters are designed to op erate from a single +5 V , details. Figure 1 illustrates the CS5525/26 connected to generate its own negative bias supply using the -
OCR Scan
750kU CS5525-AP CS5525-AS CS552B
Abstract: control and medical applications. The CS5525/26 also include a fourth order deltasigma modulator, a , filters provide any one of eight different output update rates. The CS5525/26 include a CPD (Charge Pump , amplifier when used with a combination of external diodes and capacitors. This enables the CS5525/26 to , thermocouple temperature measurements. Theory of Operation The CS5525/26 A/D converters are designed to , Characteristics section on page 3 for details. Figure 1 illustrates the CS5525/26 connected to generate their own Cirrus Logic
Original
DS202F2
Abstract: unipolar or bipolar signals in process control and medical applications. The CS5525/26 also include a , . The CS5525/26 include a CPD (Charge Pump Drive) output (shown in Figure 1). CPD provides a negative , and capacitors. This enables the CS5525/26 to measure negative voltages with re- spect to ground , CS5525/26 A/D converters are designed to operate from a single +5 V analog supply and provide several , the CS5525/26 connected to generate their own negative bias supply using the on-chip CPD (Charge Cirrus Logic
Original
CS5525AS DS202F5
Abstract: process control and medical applications. The CS5525/26 also include a fourth order deltasigma modulator , digital filters provide any one of eight different output update rates. The CS5525/26 include a CPD , thermocouple temperature measurements. Theory of Operation The CS5525/26 A/D converters are designed to , Characteristics section on page 3 for details. Figure 1 illustrates the CS5525/26 connected to generate their own negative bias supply using the on-chip CPD (Charge Pump Drive). This enables the CS5525/26 to Cirrus Logic
Original
LT1019-2.5 sps 4362
Abstract: The CS5525/26 A/D converters are designed to operate from a single +5 V analog supply and provide , illustrates the CS5525/26 connected to generate their own negative bias supply using the on-chip CPD (Charge Pump Drive). This enables the CS5525/26 to measure ground referenced signals with magnitudes down to , Figure 3. The CS5525/26 also include a fourth order deltasigma modulator, a calibration , one of eight different output update rates. The CS5525/26 include a CPD (Charge Pump Drive) output Cirrus Logic
Original
DS202F3
Abstract: and medical ap plications. The CS5525/26 also include a fourth order deltasigma modulator, a , filters provide any one of eight different output update rates. The CS5525/26 include a CPD (Charge Pump , amplifier when used with a combination of ex ternal diodes and capacitors. This enables the CS5525/26 to , ideal for thermocouple temperature measurements. Theory of Operation The CS5525/26 A/D converters are , Analog Characteristics section on page 3 for details. Figure 1 illustrates the CS5525/26 connected to -
OCR Scan
CDB552G
Abstract: required to use the converter? When the CS5525/26 is reset, the registers are set to known values. If the , are two internal read/write calibration registers in the CS5525/26 (offset, and gain). One LSB in the , available? A: The CS5525/26 can be gain calibrated with some input signal other than full scale. For , function to be incorrect. 13) Why does the offset move when the CS5525/26 with a 2.5 V reference, is , noise performance from the CS5525/26? A: Use the bipolar mode or increase the reference voltage, since Cirrus Logic
Original
DS202PP5 PI202PP3 16/20-B
Abstract: ) Do you have a multi-channel channel version of the CS5525/26? A: Yes, the CS5522 is a 2-channel version, the CS5524 is a 4-channel version, and the CS5528 is an 8-channel version of the CS5525/26. These , the gain be calibrated if a full-scale signal is not available? A: The CS5525/26 can be gain , CS5525/26? A: Use the bipolar mode or increase the reference voltage, since each of these increase , port on the CS5522/24/28 differ from the CS5525/ 26/29? A: The CS5522/24/28 contain the same 3 Cirrus Logic
Original
CS5524-AP westlake capacitors westlake capacitor DS265PP1 PI265PP1
Abstract: AN158 Application Note MEASURING HIGH VOLTAGES (5 TO 1,000 VOLTS) WITH THE CS5521/23, CS5522/24/28, AND CS5525/26 A/D CONVERTERS By Keith Coffey & Jerome Johnston The CS5521/23, CS5522/24/28, and CS5525/261 A/D converters include a low input current ( Cirrus Logic
Original
CS552 AN158REV1
Abstract: . 134 CS5521/23 . 135 CS5522/24/28 . 136 CS5525/26 , Multi-Range ADC . 136 CS5525/26: 16-Bit/20-Bit Multi-Range A/D Converters with 4-Bit Latch , CS5504 CS5505/06/07/08 CS5509 CS5510/11/12/13 CS5516/20 CS5521/23 CS5522/24/28 CS5525/26 CS5529 CS5531/32 , .56 CS4922 .57 CS4923/24/25/26/27/28/29 58 CS49300 , . 26 CS5372 . 150 CS5376 . 151 CS5394 Cirrus Logic
Original
polaroid is 426 owners manual fault codes for ericsson bts ericsson bts Technical specification CS4816 Meridian 9516 EP7212-CV-D CL-CR3470/CR3475 CL-CR3480 CL-CR3710 CL-PS6700 CL-PS7111 CL-PS7500FE
Showing first 20 results.