500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LM2907D8 Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDSO8 visit Texas Instruments
LM2907N Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDIP14 visit Texas Instruments
LM2907D8R Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDSO8 visit Texas Instruments
LM2907P Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDIP8 visit Texas Instruments
LM2907D14R Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDSO14 visit Texas Instruments
LM2917P Texas Instruments VOLTAGE-FREQUENCY CONVERTER, PDIP8 visit Texas Instruments

4-20 mA converter modbus rs485

Catalog Datasheet MFG & Type PDF Document Tags

M54020 circutor

Abstract: M54410 Converter of RS-232 / 485 to Ethernet modbus Description }} Converter of the RS-232 or RS-485 network , .5 CVM Power analyzers yy Connections: Ethernet, RS-232, RS-485, Radio Protocols: Modbus TCP , }} TCP2RS: Converter RS232-RS485 / Ethernet (Modbus/TCP): M54032 }} LM50-TCP: Alarm / Impulse Central , /4.20 mA) * Digital inputs COMMUNICATIONS FEATURES RS-232 RS-485 * Ethernet , }} Optional energy consumption and generation billing (up to 9 rates) }} RS-485 Modbus/RTU Communications
-
Original
M54020 M54020 circutor M54410 m50730 M51231 M51B11 M54080 M5-30 M54040 M54050 RS-232/485

4-20 mA converter modbus rs485

Abstract: Z-SG - Strain gauge converter gauge converter / RS485 Modbus INPUT: 6-wire bridge connections, lowest value 87 suitable for 1.4 loadcells (350 ) or 1.8 loadcells (1000 K ) OUTPUT: N.1 channel current 0.20, 4.20 mA or voltage 0.10 , SPECIFICATIONS Z-SG - Strain gauge converter / RS485 Modbus ORDER CODES Code Description Model Z-SG Software Strain gauge converter / RS485 Modbus Z-NET Configuration sw downloading from www.seneca.it , PORT RS485- Modbus RTU RS232 Load cell (strain gauge) Z-SG Seneca
Seneca
Original
PM001600 EN50081-2 4-20 mA converter modbus rs485 Z-SG - Strain gauge converter analogue input MODBUS converter strain gauge strain gauge and load cells rs232 K107A K107B K107USB USB-RS485 S107USB

RJ12 to RS485

Abstract: ) RS-485 (OMEGA® Serial Protocol and MODBUS Serial Protocol) iDRN Output: 0 to 10 V @ 10 mA max; 0 , ß DRX Series Provide RS-485 Output (ASCII Serial Protocol and MODBUS Serial Protocol) ß Free , -wire (half duplex) RS-485 (OMEGA® Serial Protocol and Modbus Serial Protocol) iDRN Output: 0 to 10 V @ 10 , iDRX Series: 2-wire (half duplex) RS-485/iDRN Series: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA , ASCII® Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485
Omega Engineering
Original
RJ12 to RS485 RJ-12 DB9-RJ12 C-12B

kd 2060 transistor

Abstract: saia factory 124 ) Interface 1 x RS-485 with MODBUS slave (option) Galvanic isolation supply/input/output/RS-485 , (option) 4 x relay or 8 x OC (option) 1 x analog (option) Interface Bargraph 1 x RS-485 MODBUS , ) RS-485 Modbus communication, Ethernet measured values logging 15 minute power logging , Separators supply/output/input - input/output RS485 Modbus Slave - - - - 85.253 V , , P12O Interface RS-485 Modbus Ethernet 10/100 Base-T (option) Galvanic isolation RS-485
LUMEL
Original
kd 2060 transistor saia factory 124 2002/95/EC EN61010-1

DIN111

Abstract: output RS-232/485 converter RS-485 repeater Each unit is supplied with a compete operator's manual , Basic Unit ß Complete Sensor to RS-485 Interface ß 500V RMS Analog Input Isolation ß 15 , Filter ß Requires +5VDC Supply ß Transient Suppression on RS-485 Communications Lines ß Screw , transmit via RS-485 to a master unit which may be a computer or other processor-based equipment. The , conditioning, scaling, linearization and conversion to either linearized ASCII data values or Modbus RTU
Omega Engineering
Original
DIN111 DIN-100 DIN-172 DIN-191 DIN-192
Abstract: duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS Serial Protocol) iDRN Output: 0 to 10 V@10 mA max , $ Software Selectable Input Ranges iDRX-ACV: 0 to 400 mV to 0 to 400 Vac iDRX-ACC: 0 to 10 mA , mA through 0 to 5 A ac; AC Voltage ranges from 0 to 400 mV to 0 to 400 Vac. ANALOG or DIGITAL , respectively and transmit via RS-485 Serial Communications. ANALOG OUTPUT MODEL The Analog Output models can be configured for outputs of 0 to 10 Vdc, 4 to 20 mA or 0 to 20 mA with the free configuration Newport Electronics
Original

DB9-RJ12

Abstract: RS485 to Ethernet Converter Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port , RS-485 (NEWPORT® Serial Protocol The Optional EIS-2B iServer module can and MODBUS Serial Protocol) connect up to thirty-two (32) iDRX iDRN Output: 0 to 10 V @ 10 mA RS-485 Signal Conditioners to an max , Closure and Open Collector Input Types RS-485 Output 1800 V Isolation Free Setup and Configuration , iDRX-FP uses digital RS-485 Serial Communication. ANALOG OUTPUT MODEL The output of iDRN-FP can be user
Newport Electronics
Original
RS485 to Ethernet Converter magnetic pickup Magnetic pickup proximity

PS-1050

Abstract: VISHAY VT 300 WEIGHT INDICATOR in RS-232, RS-422, or RS485 format with Modbus RTU protocol. Up to 32 PS-1050's can be connected point-to-point using the RS-485 serial output. · Storage Tank, Bin, and Hopper Weighing · Silo and , Protocols ASCII, Modbus RTU Maximum Cable Length 50 feet RS-232, 3200 feet for RS-422 and RS-485 , Selectable 0-10 Vdc or 4-20 mA Isolated Analog Output · Peak Hold Functions for Dynamic/Historic , Filtering · Serial Communication and Modbus RTU Protocol DESCRIPTION PS-1050 Digital/Analog
Vishay Transducers
Original
VISHAY VT 300 WEIGHT INDICATOR Digital Weighing Scale Circuit ph meter circuit apr 9600 rs 485 cable modbus Weighing scale indicator circuit PS-121

Vishay nobel AST 3p

Abstract: ast 3p AST 3P Vishay Nobel Transmitter FEATURES · Analog output ± 10 VDC, 0-20 or 4-20 mA · Serial communications: RS-485, MODBUS RTU protocol · Internal resolution > 8000000 counts · Relay outputs · Compact , instruments in the Vishay Nobel programme and can communicate via standard RS-485/MODBUS RTU protocol with a , COMMUNICATION INTERFACE Interface RS-485 (two-wires or four-wires), isolated 500V Protocol MODBUS RTU or , patented A/D converter, of high resolution and stability, serves as the heart of the transmitter. This
Vishay Transducers
Original
Vishay nobel AST 3p ast 3p AST 3P, Transmitter Vishay nobel AST 3 Vishay nobel AST-3P 95/98/2000/NT4/ME/XP
Abstract: Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port , scale iDRX Output: 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS Serial Protocol , , Contact Closure and Open Collector Input Types ß RS-485 Output ß 1800 V Isolation ß Free Setup and , signal. The iDRX-FP uses digital RS-485 Serial Communication. ANALOG OUTPUT MODEL The output of iDRN-FP can be user set for 0 to 10 V, 4 to 20 mA or 0 to 20 mA. Scaling and configuration is done with Newport Electronics
Original
Abstract: open RS-485 with digital input, 0 or 5V RS-485 with modbus protocol RS-485 with modbus protocol with digital input switch closed RS-485 with modbus protocol with digital input switch open RS-485 with , , including RS-232 and RS-485 digital communications, three contact/digital input modes, four transducer , A @120 Vac, 3 A @ 240 Vac, N.O. (Output 2) Current: 0-20 mA; 4-20 mA, 500 ohm max. (Suffix F1, F2); 0-20 mA; 4-20 mA, 1000 ohm max. (Suffix FH1, FH2) Voltage: 20 Vdc pulse Solid State Relay Omega Engineering
Original
CN8240 CN8260 CN8201-R1 CN8200 CN8201 CN8202

Weighing scale circuit

Abstract: PS-1045 -232, RS-422, or RS485 format with Modbus RTU protocol. Up to 32 transmitters can be connected point-to-point using the RS485 serial output. · Storage Tank, Bin, and Hopper Weighing Vishay Transducers , Standard Protocols ASCII, Modbus RTU Maximum Cable Length 50 feet RS-232, 3200 feet for RS-422 and RS-485 , Point Load Cell Linearization · Selectable 0-10 Vdc or 4-20 mA Isolated Analog Output · Peak Hold , Communication and Modbus RTU Protocol · Display (PS-1045) and Blind (PS-1040) Versions DESCRIPTION PS
Vishay Transducers
Original
Weighing scale circuit Digital Weighing Scale weighing scale calibration proview V/PS-1040 tactile push button switch datasheet PS-1040/45
Abstract: RS-485 communication link using either a simple, straightforward ASCII® Serial Protocol or MODBUS , °C (-328 to 1562°F) iDRX Output: 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS , output that is proportional to the input signal. The iDRX-RTD uses digital RS-485 communications. ANALOG OUTPUT MODEL The output of the iDRN-RTD can be user set for 0 to10 V, 4 to 20 mA or 0 to 20 mA , mA, 100°C = 20 mA NEWPORT manufactures many types of RTD probes. Refer to our website Newport Electronics
Original
PT100
Abstract: : 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS SERIAL Protocol) iDRN Output: 0 , output that is proportional to the input signal. The iDRX-TC uses a digital RS-485 communication link. ANALOG OUTPUT MODEL The output of iDRN-TC can be user set for 0 to10 V, 4 to 20 mA or 0 to 20 mA , DIGITAL OUTPUT MODEL The iDRX-TC is a digital signal conditioner which communicates over an RS-485 communication link using either a simple, straightforward ASCII® Serial Protocol or MODBUS Serial Protocol Newport Electronics
Original

Vishay nobel

Abstract: 4-20Ma TO PROFIBUS CONVERTER WST 3 Vishay Nobel Transducers Transmitter FEATURES · Analog output ± 10 VDC, ± 20 mA, 0-20 or 4-20 mA · Serial communication: RS-485, MODBUS RTU protocol · Fieldbus interface: Profibus DP , Vishay Nobel instruments and communicate via standard RS-485/ MODBUS RTU protocol with a common process , COMMUNICATION INTERFACE Interface RS-485 (two-wires or four-wires), isolated 500V Protocol MODBUS RTU or , unique and patented A/D converter, of high resolution and stability, serves as the heart of the
Vishay Transducers
Original
4-20Ma TO PROFIBUS CONVERTER nobel 420 converter modbus to profibus vishay nobel gate 3s nobel

PGC5000

Abstract: PGC5000 MODBUS CONNECTION : Isolated 4-20 mA, 0-300 Ohms or 300-600 Ohms Measured and calculated component concentrations Max 16 , concentrations Max 16 AI modules dual (2) packages: Isolated 4-20 mA Read 3rd party AO values for , Ethernet connections: Redundant IS analyzer network communication Single channel MODBUS TCP/IP and serial RTU: Serial RTU includes a Selectable RS-232 or RS-485 DCS connection Includes single Ethernet connection for analyzer networking Redundant MODBUS TCP/IP and serial RTU: Serial RTU
ABB Automation
Original
PGC5000 PGC5000A PGC5000B PGC5000C PGC5000 MODBUS CONNECTION PGC-5000 abb PGC5000 5 zone alarm system RJ-45 9AKK105123
Abstract: Command RS-485 Modbus Binary (option) BAUD Rates 9600, 4800, 2400, 1200, 300 Parity 8 Bits No parity , operation and ticket printing. An optional ModBus interface provides cost effective connectivity to programmable logic controllers via the RS-485 serial port. Available in panel mount format, the AN3080 comes , just a few keystrokes. Parameters include: Weighing, System, Ticket, Digital Input, Setpoints, Modbus , -232 ports and one RS-485 port are standard on the Series for EDP communications and printer functions. The Analogic
Original
R76-1/EN45501 R761/EN45501
Abstract: RS485 2 wire half duplex Baud rate: (selectable) 9,600 19,200 Protocol: Modbus RTU , , analogue output or Modbus Communications. The modules are easily installed, without the need for , Dual Relay Output Module Analogue Output Module ModBus Communication Module 262-300 262-30T , impedance: Accuracy: Thermal drift: Excitation output: 0-10 mA D.C. 0-20 mA D.C. 4-20 mA D.C. 47Ω 0.05% of full scale 100 ppm/°C 24V D.C. ±5% @ 50 mA max energy.te.com 2 TE Connectivity Crompton Instruments
Original
E75911SP CI-EPP-2187-1/14

numeric ups 600

Abstract: resistance to Current Converter 0-20mA , analogue output or Modbus Communications. The modules are easily installed, without the need for , 262-ALG Temperature Indication A.C. Voltage and Current Control 262-30A ModBus , drift: Excitation output: 0-10 mA D.C. 0-20 mA D.C. 4-20 mA D.C. 47 0.05% of full scale 100 ppm/°C 24V D.C. ±5% @ 50 mA max 262-30A True RMS A.C. Voltage and Current Meter + + 0 - 10 , modules. The modules offer relay setpoints, analogue output or ModBus communications, which are easily
Crompton Instruments
Original
numeric ups 600 resistance to Current Converter 0-20mA crompton* 262 IEC 584-1 RH -005c RELAY dual output transformer with input 24v 262-MOD

RS485 to Ethernet Converter

Abstract: entrelec link (converter) or amplify the signal (Repeater) using an ILPH. Type of connection RS232 RS422 RS485 CL , to Ethernet. TCP RS-232 RS-485 Example : Protocol conversion : Modbus is one of the , Modbus / RTU 1 N07001 060209 1SNC 116 001 C0202 · · RS232 RS422 / RS485 · · · , Range" ILPH RS 232 - 485 / Ethernet Isolated RS232 or/and RS485 to Ethernet converter Triple galvanic , from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber. Ethernet
-
Original
entrelec link ABB rs-232 pin configuration R2300 schematic of RS 485 modbus ET-24 abb 1SNA 684 202 R0100 F-69685
Showing first 20 results.