500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2151IUJ-12#PBF Linear Technology LTC2151-12 - Single 12-Bit 210Msps ADCs; Package: QFN; Pins: 40; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2153IUJ-12#PBF Linear Technology LTC2153-12 - 12-Bit 310Msps ADC; Package: QFN; Pins: 40; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy

220VAC to 5VDC transformer

Catalog Datasheet MFG & Type PDF Document Tags

220VAC to 24VDC transformer

Abstract: 220VAC to 5VDC transformer ST-COMPATIBLE OPTIC CONNECTORS Á CONNECTORED CABLES AVAILABLE Á 120/220VAC, +5VDC OR 8 TO 20VAC/DC POWER , Humidity Dimensions 36 LDM85 120VAC or 220VAC (3W wall transformer) or 10VAC to 20VAC (3W transformer rating) +8VDC to +24VDC @ 130mA or +5VDC ±0.25VDC @ 130mA -40°C to +85°C -40°C to +85°C 0-95 , transformer, 220VAC Notes: (1) For internal echo suppression, add 1 to the part number. (2) Specify length , transformer, 120VAC Pinned RS-232 connector, European wall transformer, 220VAC Socketed RS-232 connector
Dataforth
Original
LDM85-PT LDM85-ST LDM85-PE 220VAC to 24VDC transformer 220VAC to 5VDC transformer transformer 220Vac to 24Vdc CONNECTOR SMA 905 drawing 220VAC to 12VaC transformer ansi z136.1 -vcsel TTL/RS422/RS-423 RS-232C RS-422/ LDM85-P LDM85-S

220VAC to 12VDC 2A circuit diagram

Abstract: 220VAC to 5VDC 2A circuit diagram directly to the 11 OVAC or 220VAC power line to make a minimum component count 110/220VAC to 5VDC power , -+12vdc OUTPUT _L a: ♦ Direct 110/220VAC to 5VDC Conversion ♦ Minimum External Component Count ♦ , 19-0914; Rev 1; 6/97 VkMXUM AC-to-DC Regulator (110/220VAC to 5.0VDC) _General Description , . This Material Copyrighted By Its Respective Manufacturer AC-to-DC Regulator (110/220VAC to 5.0VDC , Regulator (110/220VAC to 5.0VDC) ELECTRICAL CHARACTERISTICS (continued) (Ta = +25 g, V+ = 10V, Rsense =
-
OCR Scan
MAX610 220VAC to 12VDC 2A circuit diagram 220VAC to 5VDC 2A circuit diagram 220vac to 12vdc circuit diagram 220VAC to 12VDC rectifier 220VAC to 12VDC with out transformer charger 110VAC to 12VDC regulator 110/220VAC MAX610/MAX611 MAX611 MAX612

220VAC to 12VDC 2A circuit diagram

Abstract: 220VAC to 5VDC 2A circuit diagram Controllers _Features o Direct 110/220VAC to 5VDC Conversion o Minimum , , the MAX610 connects directly to the 110VAC or 220VAC power line to make a minimum component count 110/220VAC to 5VDC power supply. The devices in the MAX610 family differ in three respects: full- or , 19-0914; Rev 1; 6/97 AC-to-DC Regulator (110/220VAC to 5.0VDC , VOUT AC2 VSET MAX610 OUV +5V DC OUTPUT VSENSE 110/220VAC INPUT V- TO µP RESET
Maxim Integrated Products
Original
MAX610CPA MAX611CPA 220VAC to 12VDC transformer 12v dc full wave bridge rectifier zener 9v 1w 240vac to 12vdc rectifier circuit 110VAC to 12VDC transformer 117VAC MAX610CSA MAX611CSA MAX612CPA MAX612CSA

220VAC to 12VDC 2A circuit diagram

Abstract: 220VAC to 12VDC transformer current-limiting resistor and a current-limiting capacitor, the MAX610 connects directly to the 110VAC or 220VAC power line to make a minimum component count 110/220VAC to 5VDC power supply. The devices in the , Controllers _Features o Direct 110/220VAC to 5VDC Conversion o Minimum , 19-0914; Rev 1; 12/94 AC-to-DC Regulator (110/220VAC to 5.0VDC) The MAX610/MAX611/MAX612 , VOUT AC2 VSET MAX610 OUV +5V DC OUTPUT VSENSE 110/220VAC INPUT V- TO µP RESET
Maxim Integrated Products
Original
5V power supply using bridge rectifier circuit of 5v from 220 ac without transformer 240 AC to 12V AC transformer circuit diagram 220VAC 5VDC power supply 220VAC to 12VDC transformer ic 220 ac voltage regulator without transformer

220VAC to 5VDC transformer

Abstract: 12v dc full wave bridge rectifier connects directly to the 100 VAC or 220 VAC power line to make a minimum component count 110/220VAC to 5VDC , Regulator (110/220VAC To 5.0VDCI _Features ♦ Direct 110/220VAC to 5VDC Conversion ♦ Minimum External , . Figure 3. Transformer Isolated 5V Power Supply. /nyjxiyH_ AC To DC Regulator (110/220VAC To 5.0VDC , change, even if the output voltage is changed via the Vset terminal. AC Tb DC Regulator (110/220VAC To 5 , _General Description The MAX600 family of AC to DC Power Converters minimizes the cost
-
OCR Scan
MAX601 MAX602 FULL WAVE RECTIFIER CIRCUITS 220 AC capacitor 220vac 12v dc full wave bridge rectifier circuit diagram Line Input AC to DC Conversion and Input Filter Capacitor Selection ac to dc regulator unregulated power supply using bridge rectifier MAX610/11/12

220VAC to 12VDC 2A circuit diagram

Abstract: panasonic ER 203 charger circuit current-limiting capacitor, the MAX610 connects directly to the 110VAC or 220VAC pow er line to make a minimum com po ne n t count 110/220VAC to 5VDC power supply. The devices in the MAX610 family differ in three , processor-based controllers. A iyJX IV M Features Direct 110/220VAC to 5VDC Conversion Minimum External , use a transformer to isolate the circuit, this circuit is NOT ISOLATED from the power line. M in im u , an input voltage of at least 8V peak to maintain a regulated 5V output, but the peak transformer
-
OCR Scan
panasonic ER 203 charger circuit 12VDC to 220VaC transformer 056 5801 MAX6114

how to convert 220v ac to 12v dc

Abstract: 220VAC to 5VDC transformer ) Features Direct 110/220VAC to 5VDC Conversion Minimum External Component Count Output Voltage Preset to , current-limiting capacitor, the MAX610 connects directly to the 110VAC or 220VAC power line to make a minimum com ponent count 110/220VAC to 5VDC power supply. The devices in the MAX610 family differ in three respects , transformer to isolate the circuit, this circuit is NOT ISOLATED from the power line. M inim um-Com p o n e n , least 8V peak to maintain a regulated 5V output, but the peak transformer output voltage must not exceed
-
OCR Scan
how to convert 220v ac to 12v dc Transformer EI 220v AC to 6v AC dc 220v to ac 3v transformer .5 50hz 77n trans 220v 2a diode bridge 4712 mosfet

max600

Abstract: AX602 count 110/220VAC to 5VDC power supply. The three members o f the MAX600 family differ in three respects , . _ Features 4 4 4 4 4 4 4 4 4 Direct 110/220VAC to 5VDC Conversion Minimum External Component Count , > H M axim In tag ratad P roducta 6-1 AC To DC Regulator ( 110/220VAC To 5.0VDC) M A X 6 0 0 /0 , /220VAC To 5.0VDC) M A X 6 0 0 /0 1 /0 2 Pin Descriptions PIN AC1 AC2 N /C V PIN # 7 1 (MAXÔ00/02 , to 5 Amps. For 110VAC input voltage R1 must be 33fi or greater; for 220VAC input voltage R1 must be
-
OCR Scan
AX602 AX601 AX801 IMAX602 600/01/0S MAX600/01/02

220VAC to 12VDC transformer ic

Abstract: 220VAC to 12VDC transformer . 5Vdc F1 Body 2. L1 Body 3. C1 Body 4. D1 5. Transformer coil 6. Transformer core 7. Inside , low no-load power consumption. A limited EMI filter is included and an additional EMI filter to input side is required to meet CISPR22-B EMI Standard. With Your Electronics POWERPLAZA , Max. @ 220VAC Frequency INPUT 47~440Hz Max. (50~60Hz typ.) Efficiency 75% Typ , . @ 110VAC / 0.75mA Max. @ 220VAC Voltage tolerance (accuracy) OUTPUT ±2% Max (single and
Power Plaza
Original
220VAC to 24VDC converter IEC-60068-2-38 Pulse Transformer 5024 220VAC single phase AC regulator 12v 50w smps SFS5-24 10-55H UL60950-1 E227474 100KH

12v dc full wave bridge rectifier

Abstract: ac to dc regulator the 110VAC or 220VAC power line to make a minimum component count 110/220VAC to 5VDC power supply. The , 110/220VAC to 5V DC Conversion Minimum External Component Count Output Voltage Preset to 5V ±4% 70mA , . 110/220VAC to SV, H alt Wave Rectification Figure 4 shows a 50mA 5V power supply using the half wave , that do not use a transformer to isolate the circuit, this circuit is NOT ISOLATED from the power line , with 220VAC input. Transformer Isolated 5V Power Supply If isolation from the power line is required
-
OCR Scan
750mF TRW-40 TRIACS EQUIVALENT LIST AX610/11/12

TOP223P

Abstract: 220VAC to 24VDC transformer designs. The inductors and transformer used with the TOPXXX are critical to the performance of the , % 3 10 µHY 4 9 7 (+5VDC@800mA) SECONDARY #1 BIAS 6 5 HIPOT: PRIMARY & BIAS TO SECONDARY PRIMARY TO BIAS SECONDARY#1 TO SECONDARY#2 3000 500 500 APP CIRCUIT PARAMETERS: SEE , 4 NOTE2: A) BOTTOM HALF OF CORE IS CUFF WRAPPED PRIOR TO ASSEMBLY. THIS GAURANTEES >6.2mm , CORE IS CUFF WRAPPED WITH MYLAR TO GUARANTEE 6.2mm PIN-CORE-PIN CREEPAGE REV. 05/11/99 06/09/99
Premier Magnetics
Original
VTP-01001 PWR-TOP223P TOP223P 2200uf 10v radial capacitor 100uF 35V nec2501-h f 1.0.0k MD 250v capacitor mylar 0.1uf UL1950 IEC950 CSA-950 PM130-R1 ECA1AFG101 ECA1VFG470
Abstract: capacitor, the MAX610 connects directly to the 110VAC or 220VAC power line to make a minimum component count 110/220VAC to 5VDC power supply. The three members of the MAX610 family differ in three respects , ircuit Features ♦ Direct 110/220VAC to 5V DC Conversion ♦ Minimum External Component , is disconnected. 110/220VAC to 5V, H alf Wave Rectification Figure 4 shows a 50mA 5V power supply , with all MAX610 family circuits that do not use a transformer to isolate the circuit, this circuit is -
OCR Scan
AX610CPA AX611CPA AX612CPA AX611

transformer 110v 220V 380V to 9v

Abstract: TRANSFORMER 220v to 9V COMPONENTS Änderungen vorbehalten / subject to change without notice SCP-2K4 2400W , adjustment by potentiometer VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 20% ~ 100% adjustment by 1 ~ 5VDC , , delay shut down o/p voltage, re-power on to recover 110 ~ 135% Follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer WORKING TEMP. Protection type : Shut down o/p voltage, recovers automatically after
RSG Electronic Components
Original
SCP-2K4-12 SCP-2K4-15 SCP-2K4-18 SCP-2K4-24 2K4S-P018 2K4S-P024 transformer 110v 220V 380V to 9v TRANSFORMER 220v to 9V transformer 220V 12V 100A 220V to 48V DC transformer 2400w pfc D-63069 260VAC 230VAC

220V to 48V DC transformer

Abstract: TRANSFORMER 220v to 9V by 1~5VDC external control 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5 , % 88% 89% Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover 110 ~ 135% Follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer WORKING TEMP. Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to output load derating curve) WORKING HUMIDITY 20
-
Original
SCP-2K4-09 transformer 220V to 15V 220V to 12V AC transformer 220v Ac- 12v Dc transformer at 60Hz PAR/230VAC Remote Control System 380v SCP-2K4-48 2K4S-P009 2K4S-P012 2K4S-P015 2K4S-P048

3A 220v transformer

Abstract: 220V to 48V DC transformer 1.0% ± 1.0% VOLTAGE TOLERANCE Note.3 ± 2.0% 20% ~ 100% adjustment by 1 ~ 5VDC external control ± , % 86% Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover 110 ~ 135% Follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer WORKING TEMP. Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +65 (Refer to output load derating
-
Original
3A 220v transformer transformer 220V to 12V 220V AC to 24V DC TRANSFORMER leakage current 220v Ac- 12v Dc transformer 60Hz electronic transformer LED 12v transformer 12V to AC 220V SCP-2K4-36 SCP-2K4-60 2K4S-P036 2K4S-P060 220/380VAC 190/110VAC

68w Transistor smd

Abstract: bbc 127 324 DIODE to 50mV 10 to 50mV 5VDC, 12VDC 5VDC, 12VDC 5VDC, 12VDC 5V, 12V, 26VDC Breaking , 8.51 x 9.53 x 7.11 9.53 x 9.53 x 7.75 85ºC Hermetic PCB TO-5 Surface Mount Version 2A , 4.25kVDC 1.5kVDC 4.25kVDC / 3.0kV rms 1.5kV rms / 2.0kVDC 1000VDC 85ºC Hermetic PCB TO-5 85ºC Hermetic PCB TO-5 70ºC Plastic Housing PCB 70ºC Plastic Sealed PCB 70ºC 70ºC , 25W 3 - 50W 10W 50W 1.25kVA 1.25kVA / 150W 1.5kVA 5 - 24VDC 5 - 24VDC 5VDC
Willow Technologies
Original
HG4100 68w Transistor smd bbc 127 324 DIODE TRANSISTOR SMD 13W smd transistor yb lamp indicator 115vac 400hz 18w smd transistor HG4516 HG4507 HG4078B SGR46G 125VAC

SBC40

Abstract: Synchro to bcd : +15VDC ±5% @ 40 ma max. +5VDC ±10% @ 600 ma max. 115VAC ±10% 47 to 66 Hz. 220VAC ±10% 47 to 66 Hz , (516) 261-3300 â'¢ TWX 510-226-0448 SIE T> 2310600 00004flS Eflfl HCC0 LOW COST SYNCHRO TO BCD , and Angle Indicators are low cost miniature synchro to digital converters with direct BCD outputs , or 4 wire resolver input and are completely transformer isolated. In addition a zero offset adjustment is offered as an option to shift the synchro zero as required (±5°) for the utmost in user
-
OCR Scan
AI500 SBC60 SBC40 Synchro to bcd AI540 SDC60T AI560

220v dc to 5V dc transformer

Abstract: transformer 220V to 12V WITHSTAND VOLTAGE SAFETY & EMC (Note. 4) 86% ISOLATION RESISTANCE 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65 , % ± 2.0% ± ± 0.5% ± 0.5% ± 2.5% 20~100% adjustment by 1~5VDC external control ± , o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP
-
Original
2K0S-N005 2K0S-N012 2K0S-N015 220v dc to 5V dc transformer 220v to 5v transformer 220V ac circuits power control CLASS D 2000W transformer 220V to 24V power control circuit 220v SCN-2K0-05 SCN-2K0-12 SCN-2K0-15 SCN-2K0-24 SCN-2K0-48

Motorola 683xx

Abstract: 220vac LED driver Microcontrollers provides the hardware and software components required to build LNS applications based on any , server (using the NSS-10 module) or as remote clients to an NSS for Windows network services server , costs; only one simple API to port and learn w Hardware and firmware-based NSI option s Allows , library, and network driver s Simplifies porting to all hosts w ANSI C source code for sample , software development to begin with no hardware development required; supports any LON W ORKS
Echelon
Original
PCC-10 PLM-30 Motorola 683xx 220vac LED driver 77040 FTM-10 PL-20N NSI-10 TPM/XF-78 TPM/XF-1250 FTM-10 TPM/RS485

220VAC to 12VDC transformer

Abstract: schematic inductive magnetic sensor flow meter Select outer locations for changing to 220Vac or 120Vac supply Display Transformer Input mains , 5Vdc, 100mA regulated 12Vdc, 50mA unregulated Input signal level: Universal type 10V max. peak to , installation, down to 0.001 q Output relays SPDT, rated at 2A, 250Vac (res), individually settable as , to 9 seconds q Trips settable for operation in all measurement modes and selectable for operating , greater than 1 q Wide measuring range; 0.001 to 99999 units per second, minute or hour with high
RS Components
Original
schematic inductive magnetic sensor flow meter schematic magnetic proximity sensor Tachometer speed display circuit Microprocessor magnetic pickup speed sensor schematic inductive proximity sensor
Showing first 20 results.