500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LM336Z-2.5#TRPBF Linear Technology LM336-2.5 - 2.5 Volt Reference; Package: TO-92; Pins: 3; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LM336Z-2.5#TR Linear Technology LM336-2.5 - 2.5 Volt Reference; Package: TO-92; Pins: 3; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy

2.5 mva transformer

Catalog Datasheet MFG & Type PDF Document Tags

2.5 MVA transformer

Abstract: (up to) 2.5 MVA plant for simple plant network deployment L00410648-02_02 / Rev. date: 2014-10-03 , I/O box 11 Grid management 12 Transformer station Illustration 2.4 System Overview , the transformer station - moving the inverters to another location - modifying the AC
SMA Solar Technology
Original
2.5 MVA transformer RJ-45

10 mva transformer

Abstract: 2.5 mva transformer . TABLE: TRANSFORMER DATA AND LOADS Transformer 1 Transformer 2 Transformer 3 Transformer 4 Transformer 5 Transformer 6 22/0.64 KV, 3 MVA 3 units with 250 KW DC motors 2 units with 350 KW DC motors 22/0.64 KV, 3 MVA 3 units with 250 KW DC motors 2 units with 350 KW DC motors 22/0.64 KV, 2.5 MVA 1 unit with 250 KW DC motors 3 units with 350 KW DC motors 22/0.64 KV, 2.5 MVA 1 unit with 250 , 's power supply consists of six transformers for a total output of 15 MVA. While two of the transformers
EPCOS
Original
10 mva transformer 1 MVA transformer mva transformer transformer 2 mva thai

neutral missing current transformer

Abstract: Distribution transformer side of the distribution transformer. It is appropriate to call this power distribution system a 3-wire, single-phase, mid-point neutral system. Distribution Transformer: a transformer supplying a 3 , standard phase-neutral voltage of 120 V. In this case, the transformer voltage is 120 V on either side of , Figure 1: Distribution Transformer In countries whose standard phase-to-neutral voltage is 120 V , secondary of the transformer are: · Line1 to Neutral: 120VAC rms (230VAC rms / Europe) · Line2 to
Teridian Semiconductor
Original
neutral missing current transformer Distribution transformer tap transformer mva 3 phase transformer 230vac voltage sag detection using rms 100 MVA transformer 78M6612

10 mva transformer

Abstract: transformer 2 mva : TRANSFORMER DATA AND LOADS Transformer 1 Transformer 2 Transformer 3 Transformer 4 Transformer 5 Transformer 6 22/0.64 KV, 3 MVA 3 units with 250 KW DC motors 2 units with 350 KW DC motors 22/0.64 KV, 3 MVA 3 units with 250 KW DC motors 2 units with 350 KW DC motors 22/0.64 KV, 2.5 MVA 1 unit with 250 KW DC motors 3 units with 350 KW DC motors 22/0.64 KV, 2.5 MVA 1 unit with 250 KW DC motors , six transformers for a total output of 15 MVA. While two of the transformers (transformers 5 and 6
EPCOS
Original
inrush reactor 20 kV 3.5 mva transformer 3,5 mva transformer 80 MVA transformer 7 MVA transformer

10 mva transformer

Abstract: transformer 2 mva /0.64 KV, 3 MVA Three units with 250 KW DC motors, two units with 350 KW DC motors Transformer 2 , Transformer 3: Loads: 22/0.64 KV, 2.5 MVA One unit with 250 KW DC motors, three units with 350 KW DC motors Transformer 4: Loads: 22/0.64 KV, 2.5 MVA One unit with 250 KW DC motors, three units with 350 KW DC motors, one unit with 172 KW DC motors Transformer 5: Loads: 22/0.4 KV, 2.0 MVA , values from 35 to more than 200% Transformer 6: Loads: 22/0.4 KV, 2.0 MVA AC motors and plant
EPCOS
Original
IEC60831 IEC61921 20 kv switchgear pfc for ac motors WindCap comba MKK800-D-25-11 Wiring Diagram Great wall 114/V1 EN61921 IEC60439-1/2/3 D-81617

5 MVA generator

Abstract: 1 MVA generator neutral is resistance grounded and the other winding neutral has a voltage transformer. Each neutral is , mVA filter 5-15V 130 V 250 V 5 mVA 10-30V 270 V 470 V 7 mVA 20-60 V 350 V 500 V 16 mVA Third-harmonic RXIG 21 with 0.15-0.45 V 25 V 40 V 1.5 mVA filter 0.4-1.2 V 60 V 120 V 2 mVA Supervision RXEG 21 40-120V 500 V 500 V 15 mVA Supervision RXIG 21 1-3 A 20 A 110 A 15 mVA Fundamental RXKE 1 0.02-99 s , adjustable resistor to an auxiliary voltage transformer with winding for fundamental frequency compensation
-
OCR Scan
B03-4012 5 MVA generator 1 MVA generator 50 mva transformer 20 MVA generator ASEA ragea protection relay ragea 468-ABA RK646 012-CB B03-4012E B03-1003E

3.5 mva transformer

Abstract: Westinghouse Sudden Pressure Relay ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­7 1 Transformer development 1a The worldâ'™s largest transformer in 1942 (220â'‰kV / 120â'‰MVA , means, that a 400 MVA transformer transfers the power needed by 400,000, the equivalent of a medium , single-phase network transformer for 1,785â'‰ rated at kV, 333â'‰ MVA. This test transformer was installed , networks. ABB is a global leader in transformer technologies that enable utility and industry customers , dry-type transformer products The quiet life ABBâ'™s ultralow-noise power transformers 33 Power
ABB
Original
Westinghouse Sudden Pressure Relay current transformer ABB induction furnace circuit diagram

500 MVA power transformers parameters

Abstract: 1MRK000 : End user: Station name: Voltage level: kV Transformer Rated Power: MVA ABB Network Partner Transformer , J^ | II Transformer protection RET 521 terminal 1MRK504 001-BEN Page 1 Issued June 1998 Changed , transformer protection terminal in a compact design â'¢ Numerical microprocessor design with advanced , '¢ Two-winding transformer application â'¢ Three-winding transformer application â'¢ Both with multi-breaker , tracking and filter adaptation â'¢ Functional modular and type tested software â'¢ Transformer differential
-
OCR Scan
500 MVA power transformers parameters 1MRK000 multiple Transformer oil monitoring with automatic circuit breaking operation automatic 3 phase changer transformer calculation ret 521 three-winding power transformer SE960158 010-BEN 015-BEN 1MRK511 057-BEN

RXIG21

Abstract: RK411 with an esclamai reselling-device. The RXIG 21 has an inpul transformer with airgap- which makes 1he , in (he inuut transformer alsp enables the natay to be used Tor monitoring 1he alternating currenL , genpr^lyr pruleclions. elc Thg mtì-ASu'iny cirwil t>1 RWG 28 consumes- a. minimum of power - , 50A Ol operating value in â -". ± S within the range 0.1 A 7 mVA 3A B&A % ol 1he operating value Sû-at)ûHz 0.25 A 7 mVA 7.S A £30 A al rated Ireqvency: flXlG 20 0.5 A 7 mVA ISA a^OA ni + 115 "ü
-
OCR Scan
FTK411 RXIG21 RK411 RXIG 22 rk 11 e asea sv RK 411 rxig22 RK41-14E T-00CM37 RKHS22 S-721

40 MVA transformer

Abstract: transformer 2 mva reconnectible 0,03-0,060,12 A or 0,2-0,4-0,8 A · 2nd harmonic restraint for stability at transformer inrush , typical application is as a sensitive back-up protection in a transformer neutral or at a power line , . The transformer inrush current is heavily distored and has a high percentage of second harmonic , is set to operate at a lower current than the enabled relay. When a transformer is switched in , transformer's rated current, and it is gradually damped to a normal magnetizing current of some percent of
-
Original
003-BEN 052-EB 052-DBA 005-BEN 40 MVA transformer RXKL 1 RTXP 18 1MRK 514 001-BEN RTXP 18 abb DIMENSIONS SE970885 052-EA 839-AA

BROWN BOVERI HT relay

Abstract: BROWN BOVERI relay type S . The main components in the relay are a primary reconnectable current transformer, a rectifier, two , ground-fault relay RAISA, to restrain, as required, the impact of an inrush of current from a power transformer , 0.02 mVA for I, = 20 mA
-
OCR Scan
BROWN BOVERI HT relay BROWN BOVERI relay type S BROWN BOVERI relay type hb asea relay RI BROWN BOVERI relay ASEA RI B03-2212E 101-AA B03-9312E B03-9301E B03-9382E B03-9113E

4 Shaft current transformer ILDD

Abstract: ILDD Shaft current transformer ~ Transformer unit Basic measuring unit Optional MMC unit, RLHC 100, RLHD 100 RLOA 100, RLOB 100 , unit (2004-1) The transformer unit RLHC 100/RLHD 100 is used to adapt the external inputs for , circuits. The input signals from the transformer unit are passed through analogue filters and then , . The impedance zone 2 is normal/y set to "see" through the step-up transformer and to have a time de/BY , transformer and is normal/y not de/ayed. The re/BY can be set to measure phase-to-phase or phase-to-neutra
-
Original
101-BA 004-GB RK682 4 Shaft current transformer ILDD ILDD Shaft current transformer 5 MVA synchronous machine ABB 5 MVA generator synchronous MDBO2004-EN 1MDB14005-EN 006-AA 008-AA 11Q-120V

RXSF1

Abstract: asea transformer phase-current transformers, a zero-sequence-current transformer, and rectifying and smoothing circuits. The primaries of all transformers car be reconnected. For the zero-sequence-current transformer, a primary , transformer. When It Is residually connected, 0,1 or 0,5 A is recommended. The basic current Jt of the , basic current Ig. The product of and the ratio of the main current transformer Is normally equai to the , current selected on the zero-saquence current transformer, The operating time is fixed at 50 ms or 200 ms
-
OCR Scan
RXSF1 asea transformer da rk cubicles catalogue T452 007-DA 1-10E RK92-200 RK000-100 1976-JQ-25

four relay stabilizer circuit diagram

Abstract: B03-9301 restrained relay when a low setting below the transformer inrush current is needed. The type RXIDG 2H has a , mainly of a tapped input current transformer, rectifier, 2 adjustable level detectors, 2 time delay , the input current transformer. Minimum relay pick-up value is set in terms of the base current Ia. The , transformer Is = 20, 40, 80 and 160 mA 2. Base current setting Ia = (1-2) x Is 3. Rectifying with smoothing 4 , supply stabilizer The secondary current from the tapped current transformer (1) is transfered to a
-
OCR Scan
four relay stabilizer circuit diagram B03-9301 RXIDG Characteristic function RXTUG21H over current relay B03-9510 BG03-2212 B03-2311E

RAEPA

Abstract: RXKL 1 during a secondary test. The RXPE 47 relay consists mainly of one input current transformer and one input voltage transformer (both providing isolation), a phase-sensitive rectifier circuit, a low pass filter , for range 10-40 mA 0,1 mVA 30-120 mA 0,1 mVA 0,1-0,4 A 0,15 mVA 0,3-1,2 A 0,5 mVA 1-4 A 4 mVA 3-12 A 25 mVA Voltage circuit 1,4 VA, PF = 0,9 cap Dimension RXPE 47 4U 12C Earth-fault protection
-
OCR Scan
RAEPA RXPE RXPE47 E310A RTXP18 weight el 509 030-BEN 0031-BCA 4U24C 130-BB 0031-CCA 130-CB

calculation of transformer earthing resistor

Abstract: abb rxdsb 4 transformer, the type of transformer connection, the method of neutral earthing, the fault MVA rating of the , Edition 2 RK 625-3QQ E Rsa- 7454 Page I Transformer differential.relay type RADSB The transformer relay , during transformer over-excitation. o variable percentage restraint circuitry, settable 0.25, 0.35 and , transformer differential relay type RADSB in a version with two through-fault restraint input circuits and , STORAGE 22 REFERENCE PUBLICATIONS 23 ENCLOSURES GENERAL Connection A transformer differential relay is
-
OCR Scan
RXD53 calculation of transformer earthing resistor abb rxdsb 4 RK 626-101 E asea RADSB radsb rxdsb 4 esp 110

wiring diagram of autotransformer for three phase

Abstract: asea RADSE ior the static civ-ou its. Transformer connection1) Transformer stze MVA Inslantanaous setf'ng whan , ASEA Catalogue RK 62-10 E Edition 4 January 107S File R. Part 1 Transformer differential relay type RADSE RADSE is a static, transformer differential relay with outstanding speed, sensitivity a n tJ secu rity. Only o ns relay is req u -¡reef to protect the three phases of a transformer. The relay can be , any one transformer winding. Solid state circuitry is used to create three separate restraints: 1. The
-
OCR Scan
RXDSE43 wiring diagram of autotransformer for three phase asea RADSE RXDSE Transformer differential protection RADSE RADSE asea ri 5A relay 5-30D 315-AF 315-CE

RXvea

Abstract: instantaneous overcurrent relay and a zero-sequence-current transformer. The primaries of the transformers can be reconnected. For the zero-sequence-current transformer, a primary current of 2.5 mA or 10 mA is recommended when the ground- fault relay is connected to a cable current transformer. When it is residually connected, 0.1 or 0.5 A is recommended , Ini = rated primary current of zero-sequence-current transformer_ General Is reconnectible I Mi , mVA 2 A 90 mVA 5 A 250 mVA Ground current circuit at and for IN|
-
OCR Scan
RXvea instantaneous overcurrent relay RAMDA rxief2h rxsf-1 motor asea B03-4510E 012-FAA B03-951OE B03-9112E B03-1215E B03-1111E

RXIDk 2H

Abstract: asea ri 5A relay input transformer. Two current levels are settable for a shorted or open diode. Fig. 2 Very , connected to prevent unwanted operation at transformer energizing.This is necessary when inrush currents , , delayed stage. The relay consists mainly of a input current transformer (for isolation), filter circuits , current transformer (for isolation), filter circuits, microprocessor, HMI, LEDs for start and trip , I = Is = 0,1 A I = Is = 1 A 5 A variant I = Is = 0,5 A I = Is = 5 A 0,03 mVA 1,2 mVA 0,5
ABB Automation
Original
1MDU09024-EN RXIDk 2H 838-HA RXIDG ABB RXIDF MVA generator 002-BEN SE970134 SE970150 838-SA 838-TA 137-GA

BROWN BOVERI Relay manual

Abstract: ABB RXNAC of the two input voltages to the relay can be taken from capacitive layers of a current transformer , ) Voltage check unit RXNAC 2H (113) Transformer unit RXTTB 2 (119) Transformer unit RXTTA 1 (319) Auxiliary , % of the rated voltage. Voltage check unit RXNAC 2H The voltage check unit is via the transformer units , relay RXM£ l is energized. Transformer units Of the two transformer units RXTTA 1 and RXTfB 2, the , transformer. RXTTB 2 has the terminal marking 101:9A and :10A. The standard version of the transform«' units
-
OCR Scan
BROWN BOVERI Relay manual ABB RXNAC RTXH18 rtxH 24 Relay RXM block diagram of transformer with breaker 006-AB
Showing first 20 results.